ICF-1180I-S-ST [MOXA]

Industrial PROFIBUS-to-fiber converters;
ICF-1180I-S-ST
型号: ICF-1180I-S-ST
厂家: Moxa    Moxa
描述:

Industrial PROFIBUS-to-fiber converters

文件: 总4页 (文件大小:1480K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ICF-1180I Series  
Industrial PROFIBUS-to-fiber converters  
Features and Benefits  
Fiber-cable test function validates fiber communication  
Auto baudrate detection and data speed of up to 12 Mbps  
PROFIBUS fail-safe prevents corrupted datagrams in functioning segments  
Fiber inverse feature  
Warnings and alerts by relay output  
2 kV galvanic isolation protection  
Dual power inputs for redundancy (Reverse power protection)  
Extends PROFIBUS transmission distance up to 45 km  
Wide-temperature model available for -40 to 75°C environments  
Supports Fiber Signal Intensity Diagnosis  
Certifications  
Introduction  
The ICF-1180I industrial PROFIBUS-to-fiber converters are used to convert PROFIBUS signals from copper to optical fiber. The converters are  
used to extend serial transmission up to 4 km (multi-mode fiber) or up to 45 km (single-mode fiber). The ICF-1180I provides 2 kV isolation  
protection for the PROFIBUS system and dual power inputs to ensure that your PROFIBUS device will perform uninterrupted.  
Fiber Cable Test Function  
Fiber-optic cables are usually deployed for long-distance communication. To ensure proper communication across the fiber-optic cables,  
engineers use fiber sensors. A fiber cable test function through DIP switch adjustments helps ICF-11801 converters eliminate the need to rely on  
fiber-optic sensors.  
This function not only detects fiber communication abnormalities but also validates the format of the received packet. It can also determine which  
side (Tx or Rx) is causing the problem.  
PROFIBUS Fail-Safe  
When the PROFIBUS device malfunctions or the serial interface fails,  
it will generate electrical noise, resulting in bus failure. Traditional  
media converters will let the noise signal pass through the fiber and  
on to the other converter. This will disrupt data transmissions  
between the two buses and eventually communication ceases across  
the entire system. When this occurs, the engineer will not be able to  
easily locate the failed device because the entire PROFIBUS network  
is down. To avoid this situation, the ICF-1180I was designed to detect  
and recognize noise signals. If the bus fails on one side, the noise  
signal will not propagate through the ICF-1180I and affect additional  
bus segments. In addition, the ICF-1180I will also trigger an alarm  
notification to the field engineer on the location of the failure.  
Auto/Manual Baudrate Settings  
The ICF-1180I Series simply converts the signal back and forth between PROFIBUS and fiber. The ICF-1180I Series works under baudrates  
between 9.6 kbps to 12 Mbps. Engineers do not need to know the baudrate of the connected PROFIBUS device.  
The ICF-1180I Series can automatically detect the baudrate of the PROFIBUS device and apply this baudrate directly. This is an extremely  
convenient feature. If necessary, baudrates can be set to a fixed value via DIP switches.  
Fiber Inverse Function  
The ICF-1180I provides a fiber inverse function to choose fiber-optic light ON or light OFF when sending logic signal ‘1’. For default settings, fiber-  
optic is light OFF when sending logic signal ‘1’; in Fiber Inverse mode, fiber-optic is light ON when sending logic signal ‘1’.  
1
www.moxa.com  
This feature provides greater compatibility when the ICF-1180I converter is integrated with PROFIBUS converters of other manufacturers. Please  
refer to third-party user manuals when using this feature.  
Fiber Link Monitor  
The ICF-1180I converters provide a fiber link monitor function to detect the communication errors on either the fiber side or PROFIBUS side. Once  
there is an error in communication, the corresponding LED will turn red, and the relay alarm will be activated.  
Fiber Signal Intensity Diagnosis  
In some circumstances, you may need to measure the reception level  
of the fiber-optic port with a voltmeter, which can be connected while  
the device is operating (doing so will not affect data transmission).  
The measurement can be taken with a voltmeter and read on a PLC  
that uses floating high impedance analog inputs, which allow you to  
do the following:  
• Record the incoming optical power for later measurement (e.g., to  
indicate aging or damage).  
• Carry out a good/bad test (limit value).  
Specifications  
Serial Interface  
Connector  
ICF-1180I-M-ST: Multi-mode ST connector  
ICF-1180I-M-ST-T: Multi-mode ST connector  
ICF-1180I-S-ST: Single-mode ST connector  
ICF-1180I-S-ST-T: Single-mode ST connector  
Optical Fiber  
Multi-Mode  
Single-Mode  
1310 nm  
-7 dBm  
Wavelength  
Tx Output  
820 nm  
-14 dBm  
-28 dBm  
14 dBm  
4 km  
Rx Sensitivity  
Link Budget  
Typical Distance  
-29 dBm  
21 dBm  
45 km  
PROFIBUS Interface  
Industrial Protocols  
PROFIBUS DP  
1
No. of Ports  
Connector  
Baudrate  
Isolation  
DB9 female  
9600 bps to 12 Mbps  
2 kV (built-in)  
Signals  
PROFIBUS D+, PROFIBUS D-, RTS, Signal Common, 5V  
Power Parameters  
Input Current  
269 mA @ 12 to 48 VDC  
12 to 48 VDC  
Input Voltage  
No. of Power Inputs  
Overload Current Protection  
Power Connector  
2
Supported  
Terminal block (for DC models)  
269 mA @ 12 to 48 VDC  
Power Consumption  
Physical Characteristics  
Housing  
Metal  
IP30  
IP Rating  
2
www.moxa.com  
Dimensions  
Weight  
30.3 x 115 x 70 mm (1.19 x 4.53 x 2.76 in)  
180 g (0.39 lb)  
Installation  
DIN-rail mounting (with optional kit), Wall mounting  
Environmental Limits  
Operating Temperature  
Standard Models: 0 to 60°C (32 to 140°F)  
Wide Temp. Models: -40 to 75°C (-40 to 167°F)  
0 to 60°C (32 to 140°F)  
-40 to 75°C (-40 to 167°F)  
0 to 60°C (32 to 140°F)  
-40 to 75°C (-40 to 167°F)  
Storage Temperature (package included)  
Ambient Relative Humidity  
-40 to 85°C (-40 to 185°F)  
5 to 95% (non-condensing)  
Standards and Certifications  
EMC  
EN 55032/24  
EMI  
CISPR 32, FCC Part 15B Class A  
EMS  
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV  
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m  
IEC 61000-4-4 EFT: Power: 0.5 kV  
IEC 61000-4-5 Surge: Power: 0.5 kV  
IEC 61000-4-6 CS: 3 V  
IEC 61000-4-8 PFMF  
Environmental Testing  
IEC 60068-2-1  
IEC 60068-2-2  
IEC 60068-2-3  
Hazardous Locations  
Safety  
ATEX, Class I Division 2, IECEx  
EN 60950-1, IEC 60950-1  
IEC 60068-2-6  
Vibration  
MTBF  
Time  
1,722,769 hrs  
Standards  
Telcordia (Bellcore), GB  
Warranty  
Warranty Period  
5 years  
Details  
See www.moxa.com/warranty  
Package Contents  
Device  
1 x ICF-1180I Series converter  
Documentation  
1 x quick installation guide  
1 x warranty card  
3
www.moxa.com  
Dimensions  
Ordering Information  
Model Name  
Operating Temp.  
0 to 60°C  
Fiber Module Type  
Multi-mode ST  
Single-mode ST  
Multi-mode ST  
Single-mode ST  
ICF-1180I-M-ST  
ICF-1180I-S-ST  
ICF-1180I-M-ST-T  
ICF-1180I-S-ST-T  
0 to 60°C  
-40 to 75°C  
-40 to 75°C  
© Moxa Inc. All rights reserved. Updated Apr 14, 2020.  
This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of  
Moxa Inc. Product specifications subject to change without notice. Visit our website for the most up-to-date product information.  
4
www.moxa.com  

相关型号:

ICF-1180I-S-ST-T

Industrial PROFIBUS-to-fiber converters
MOXA

ICF-1280I

Industrial PROFIBUS-to-fiber converters with redundant fiber ring
MOXA

ICF-1280I-M-ST

Industrial PROFIBUS-to-fiber converters with redundant fiber ring
MOXA

ICF-1280I-M-ST-T

Industrial PROFIBUS-to-fiber converters with redundant fiber ring
MOXA

ICF-1280I-S-ST

Industrial PROFIBUS-to-fiber converters with redundant fiber ring
MOXA

ICF-1280I-S-ST-T

Industrial PROFIBUS-to-fiber converters with redundant fiber ring
MOXA

ICF-308-F-I

IC Socket, DIP8, 8 Contact(s), 2.54mm Term Pitch, 0.24inch Row Spacing,
SAMTEC

ICF-308-F-I-TR

IC Socket, DIP8, 8 Contact(s), 2.54mm Term Pitch, 0.24inch Row Spacing,
SAMTEC

ICF-308-F-O

IC Socket, DIP8, 8 Contact(s), 2.54mm Term Pitch, 0.36inch Row Spacing,
SAMTEC

ICF-308-F-O-TR

IC Socket, DIP8, 8 Contact(s), 2.54mm Term Pitch, 0.36inch Row Spacing,
SAMTEC

ICF-308-FM-I-TR

IC Socket, DIP8, 8 Contact(s),
SAMTEC

ICF-308-FM-O

IC Socket, DIP8, 8 Contact(s),
SAMTEC