A417RU [MPD]
Single & Dual Output, 4W Ultra-Wide Input Range DC/DC Converters; 单,双输出, 4W超宽输入范围DC / DC转换器型号: | A417RU |
厂家: | MICROPOWER DIRECT, LLC |
描述: | Single & Dual Output, 4W Ultra-Wide Input Range DC/DC Converters |
文件: | 总2页 (文件大小:169K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
A400RUSeries
Single & Dual Output, 4W
Ultra-Wide Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
• 4W Output Power
Conditions
24 VDC Input
48 VDC Input
Min.
4.5
8.5
Typ.
6.0
12.0
Max.
8.5
17.0
Units
Input Start Voltage
VDC
• UL Approved (File E245422)
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• Meets EN55022 Class “A”
• Compact DIP Case
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
π (Pi) Filter (Complies with EN55022 Class “A”)
1.0
2,000
A
mW
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Conditions
Min.
Typ.
0.5
0.5
0.1
0.3
50
Max.
1.0
2.0
0.3
1.0
75
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
μSec
%
• Single & Dual Outputs
• 1.0 MH MTBF
Dual Output , Balanced Loads
Vin = Min to Max
• Industry Standard Pin-Out
Load Regulation
Iout = 10% to 100%
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Over Line, Load & Temp.
25% Load Step Change
100
15
120
150
2.0
0.01
500
0.02
%/ºC
Continuous (Autorecovery)
General
Parameter
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
Units
VDC
MΩ
pF
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
380
350
500
kHz
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
RoHS Compliant
Conditions
Min.
Typ.
+25
Max.
+71
+90
Units
ºC
ºC
Ambient
Case
-40
-40
-40
+125
ºC
Free Air Convection
RH, Non-condensing
Humidity
95
%
RFI
Six-Side Shielded Metal Case
Complies with EN55022 Class “A”
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conducted EMI
Physical
Case Size
Case Material
Weight
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Metal with Non-Conductive Base
0.49 Oz (14g)
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Reliability Specifications
Parameter
MTBF
Conditions
Min.
Typ.
Max.
Units
MHours
MIL HDBK 217F, 25ºC, Gnd Benign
1.0
Safety Standards
Safety Approvals
UL 1950, EN 60950, IEC 60950
UL, cUL; File No. E245422
Absolute Maximum Ratings
Parameter
Conditions
Min.
Typ.
Max.
50.0
100.0
260
Units
24 VDC Input -0.7
48 VDC Input -0.7
1.5 mm From Case For 10 Sec.
All Models
Input Voltage Surge (1 Sec)
VDC
Lead Temperature
Internal Power Dissipation
ºC
mW
2,500
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input
Current (mA)
Output
Fuse Rating
Slow-Blow
(mA)
Voltage (VDC)
Model
Reflected
Ripple
Current
(mA, Typ)
Efficiency
(%, Typ)
Voltage Current
(VDC) (mA, Max) (mA, Min)
Current
Number
Nominal
Range
Full-Load No-Load
A401RU
A402RU
A403RU
A404RU
A405RU
A406RU
A407RU
A411RU
A412RU
A413RU
A414RU
A415RU
A416RU
A417RU
24
24
24
24
24
24
24
48
48
48
48
48
48
48
9.0 -36.0
9.0 -36.0
9.0 -36.0
9.0 -36.0
9.0 -36.0
161
170
201
201
156
201
201
79
84
98
98
76
20
20
20
20
20
20
20
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
5
5
5
5
5
3.3
5.0
12.0
15.0
5.0
12.0
15.0
3.3
900.0
660.0
333.0
267.0
300.0
167.0
133.0
900.0
660.0
333.0
267.0
300.0
167.0
133.0
90.0
66.0
33.0
27.0
30.0
17.0
13.0
90.0
66.0
33.0
27.0
30.0
17.0
13.0
77
81
83
83
80
83
83
78
82
85
85
82
85
85
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
9.0 -36.0
9.0 -36.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
5.0
12.0
15.0
5.0
12.0
15.0
98
98
500
500
Notes:
Derating Curve
1. When measuring output ripple, it is recommended that an external
0.47 μF ceramic capacitor be placed from the +Vout pin to the -Vout
pin for single output units and from each output to common for
dual output units. For noise sensitive applications, the use of 3.3
μF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a
load step change of 75% to 100%.
3. Operation at no-load will not damage these units. However, they
may not meet all specifications.
4. Dual output units may be connected to provide a 10 VDC,
24 VDC or 30 VDC output. To do this, connect the load across the
positive (+Vout) and negative (-Vout) outputs and float the output
common.
5. The converter should be connected to a low ac-impedance source.
An input source with a highly inductive impedance may affect
the stability of the converter. In applications where the converter
output loading is high and input power is supplied over long lines,
it may be necessary to use a capacitor on the input to insure start-
up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100
kHz) capacitor be mounted close to the converter. For 24V input
units a 4.7 μF is recommended and for 48V units a 2.2 μF.
6. It is recommended that a fuse be used on the input of a power
supply for protection. See the table above for the correct rating.
Mechanical Dimensions
Pin Connections
Pin
2, 3
9
Single
Dual
-Vin
-Vin
No Pin Common
11
NC
-Vout
+Vout
14
+Vout
-Vout
+Vin
16
Common
+Vin
22, 23
NC: No Connection
Capacitive Load
Single Output Dual Output
μF Max
μF Max
3,000
680
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.25)
MicroPower Direct
•
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com