MA624D05RWI [MPD]
MA600RWI SERIES;型号: | MA624D05RWI |
厂家: | MICROPOWER DIRECT, LLC |
描述: | MA600RWI SERIES |
文件: | 总2页 (文件大小:483K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MA600RWISeries
Wide 2:1 Input, 6W,
High 3 kVDC Isolation
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 6W Output Power
Input
Parameter
Conditions
12 VDC Input
Min.
7.0
Typ.
8.0
Max.
9.0
Units
• 2:1 Input Voltage Range
• 3,000 VDC Isolation
• 24 Standard Models
• Single & Dual Outputs
• Compact DIP Case
• -40°C to +85°C Operation
• Industry Standard Pin-Out
Input Start Voltage
24 VDC Input 14.0
48 VDC Input 32.0
12 VDC Input
24 VDC Input
48 VDC Input
16.0
34.0
18.0
36.0
8.5
16.0
35.0
VDC
Under Voltage Shutdown
VDC
Input Filter
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
ꢀ (Pi) Filter
Conditions
Min.
Typ.
1.0
1.0
0.1
0.6
Max.
2.0
2.0
0.5
1.2
70
100
600
Units
%
%
%
%
Dual Output, Balanced Loads
VIN = Min to Max
IOUT = 0% to 100%
See Note 1
Over Line, Load & Temp.
Ripple & Noise (20 MHz)
mV P - P
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Overload Protection
Output Short Circuit
General
300
3.0
0.01
145
µSec
%
%/°C
%
25% Load Step Change
1.5 kV Isolation
Models
0.02
Foldback
110
Available
Continuous (Autorecovery)
Parameter
Conditions
Min.
60 Seconds 3,000
500 VDC 1,000
Typ.
Max.
Units
VDC
M
pF
kHz
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
4:1 Input Range
Models
100 kHz/1.0V
1,000
330
Available
Standard
Level
Radiated Emissions
Conducted Emissions
ESD
EN 55022
EN 55022
Class A
Class A
EN 61000-4-2 Criteria A; 8 kV Air 6 kV Contact
RS
EFT
Surge
CS
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Criteria A; 10V/m
Criteria A; 2 kV
Criteria A; 1 kV
Criteria A; 10V/m
See Note 3
See Note 3
Environmental
Parameter
Conditions
Min.
-40
Typ.
+25
Max.
+85
+100
+125
Units
°C
°C
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-50
°C
Free Air Convection
RH, Non-condensing
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Humidity
95
%
Physical
Case Size
Case Material
Weight
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Non-Conductive Black Plastic (UL94-V0)
0.45 Oz (12.8g)
Reliability Specifications
Parameter
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Typ.
Max.
Units
MHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
MTBF
Absolute Maximum Ratings
Parameter
Conditions
Min.
Max.
25.0
50.0
100.0
260
Units
VDC
°C
12 VDC Input -0.7
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Fuse
Rating
Reflected
Ripple
Capacitive
Model
Number
Efficiency
(%, Typ)
Voltage (VDC)
Current (mA)
Full-Load No-Load
Load
Voltage Current
Current
Current
(mA Typ)
Slow-Blow
(mA)
(µF, Max)
(VDC)
(mA, Max) (mA, Min)
Nominal
12
Range
MA612S-03RWI
MA612S-05RWI
MA612S-12RWI
MA612S-15RWI
MA612S-24RWI
MA612D-05RWI
MA612D-12RWI
MA612D-15RWI
MA624S-05RWI
MA624S-05RWI
MA624S-12RWI
MA624S-15RWI
MA624S-24RWI
MA624D-05RWI
MA624D-12RWI
MA624D-15RWI
MA648S-03RWI
MA648S-05RWI
MA648S-12RWI
MA648S-15RWI
MA648S-24RWI
MA648D-05RWI
MA648D-12RWI
MA648D-15RWI
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
440
641
609
609
595
534
609
609
214
313
298
298
298
260
298
298
107
156
149
149
149
130
149
149
40
40
40
40
40
40
40
40
20
20
20
20
20
20
20
20
10
10
10
10
10
10
10
10
3.3
5.0
1,200.0
1,200.0
500.0
400.0
250.0
500.0
250.0
200.0
1,200.0
1,200.0
500.0
400.0
250.0
500.0
250.0
200.0
1,200.0
1,200.0
500.0
400.0
250.0
500.0
250.0
200.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
75
78
82
82
84
78
82
82
77
80
84
84
84
80
84
84
77
80
84
84
84
80
84
84
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
470
470
100
100
47
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
700
12
12
12.0
15.0
24.0
5.0
12
12
12
100
100
100
470
470
100
100
47
12
12.0
15.0
3.3
12
24
24
5.0
700
24
12.0
15.0
24.0
5.0
700
24
700
24
700
24
100
100
100
470
470
100
100
47
700
24
12.0
15.0
3.3
700
24
700
48
350
48
5.0
350
48
12.0
15.0
24.0
5.0
350
48
350
48
350
48
100
100
100
350
48
12.0
15.0
350
48
350
Notes:
0. When measuring output ripple, it is recommended that an external 3.3 µF ceramic capacitor be placed from the
+VOUT pin to the -VOUT pin for single output units and from each output to common for dual output units.
2. Transient recovery is measured to within a 0% error band for a load step change of 75% to 0±±%.
3. Operation at no-load will not damage these units.
4. An external 22± µF/0±±V capacitor connected across the input pins is required to meet EN60±±±-4-4 and
EN60±±±-4-5.
For 1.5 kV Isolation, See MA600x-xxRW Series Datasheet
For 4:1 Inputs, See MA600x-xxRU Series Datasheet
5. Dual output units may be connected to provide a 0±, 24 or 3± VDC output. To do this, connect the load across the
positive (+VOUT) and negative (-VOUT) outputs and float the output common.
6. The converter should be connected to a low ac-impedance source. An input source with a
highly inductive impedance may affect the stability of the converter. In applications where
Mechanical Dimensions
the converter output loading is high and input power is supplied over long lines, it may be
necessary to use a capacitor on the input to insure start-up. In this case, it is recommended
that a low ESR (ESR <0.±ꢁ at 0±± kHz) capacitor be mounted close to the converter. For
02V input units a 3.3 µF is recommended; and for 24V & 48V units a 2.2 µF.
7. It is recommended that a fuse be used on the input of a power supply for protection. See
the table above for the correct rating.
Derating Curve
Pin
Single
Dual
2, 3
9
-VIN
-VIN
No Pin Common
11
NC
-VOUT
+VOUT
14
+VOUT
-VOUT
+VIN
16
Common
+VIN
22, 23
NC: No Connection
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.x = ±±.±2 (±±.5±)
• Tolerance x.xx = ±±.±0 (±±.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com