MA648MD12HI [MPD]
MA600MHI SERIES;型号: | MA648MD12HI |
厂家: | MICROPOWER DIRECT, LLC |
描述: | MA600MHI SERIES |
文件: | 总2页 (文件大小:252K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series
MA600MHI
High Isolation, 6W
Medical Approved
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 6W Output Power
• 4 kVAC rms Isolation
• Reinforced Insulation
• 2 µA Leakage Current Max
• Wide 2:1 Input Range
• Compact DIP Case
• Single & Dual Outputs
• Meets EN55022
Parameter
Conditions
12 VDC Input
Min.
7.0
Typ.
8.0
15.0
33.0
Max.
9.0
18.0
36.0
8.5
Units
Input Start Voltage
24 VDC Input 13.0
48 VDC Input 30.0
12 VDC Input
24 VDC Input
48 VDC Input
VDC
Under Voltage Shutdown
16.0
34.0
VDC
Input Filter
(Pi) Filter (Complies with EN55022 Class A)
Leakage Current
Short Circuit Input Power
Output
240 VAC, 60 Hz
2
µA
mW
3,000
Parameter
Conditions
Min.
Typ.
0.5
0.5
0.3
0.5
75
Max.
1.0
2.0
0.5
1.0
100
150
180
25
Units
%
%
%
%
• 700 kH MTBF
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Dual Output , Balanced Loads
Vin = Min to Max
• EN 60950 Approved
• EN 60601 Approved
Iout = 25% to 100%
5V Output
All Other Outputs
Over Line, Load & Temp.
Ripple & Noise (20 MHz), See Note 1
mV P - P
100
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
mV P - P
mV rms
%
µSec
%
120
300
3.0
0.02
500
6.0
0.05
25% Load Step Change
%/ºC
Continuous (Autorecovery)
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC rms
VPk
VAC
M⍀
Isolation Voltage, Rated
Isolation Test Voltage
Reinforced Insulation Working Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
60 Seconds 4,000
Flash Tested For 1 Sec 6,000
300
500 VDC 1,000
100 kHz, 1V
7
150
13
pF
kHz
Parameter
Conditions
Min.
-40
-40
-50
Typ.
Max.
+75
+95
Units
ºC
ºC
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
+125
ºC
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
1.25 x 0.80 x 0.47 Inches (31.8 x 20.3 x 12.0 mm)
Non-Conductive Black Plastic (UL94-V0)
0.63 Oz (18.0g)
MicroPower Direct
292 Page Street
Suite D
Case Material
Weight
Reliability Specifications
Parameter
Stoughton, MA 02072
USA
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign
700
kHours
Safety Approvals
UL 60601, UL 60950, EN 60601, EN 60950
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Absolute Maximum Ratings
Parameter
Conditions
Min.
Typ.
Max.
25.0
50.0
100.0
260
2,500
Units
12 VDC Input -0.7
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (1 Sec)
VDC
Lead Temperature
Internal Power Dissipation
1.5 mm From Case For 10 Sec
All Models
ºC
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Reflected
Ripple
Current
Fuse Rating
Slow-Blow
(mA)
Capacitive
Load
(µF, Max)
Model
Number
Efficiency
(%, Typ)
Voltage (VDC)
Current (mA)
Voltage Current
(VDC) (mA, Max) (mA, Min)
Current
Nominal
Range
Full-Load No-Load (mA, Typ)
MA612MS-05HI
MA612MS-12HI
MA612MD-12HI
MA612MD-15HI
MA624MS-05HI
MA624MS-12HI
MA624MD-12HI
MA624MD-15HI
MA648MS-05HI
MA648MS-12HI
MA648MD-12HI
MA648MD-15HI
12
12
12
12
24
24
24
24
48
48
48
48
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
570
641
641
641
278
313
313
313
139
156
156
156
30
30
30
30
20
20
20
20
10
10
10
10
60
60
60
60
30
30
30
30
15
15
15
15
5.0
12.0
12.0
15.0
5.0
12.0
12.0
15.0
5.0
1,000
500
250
200
1,000
500
250
200
1,000
500
250
200.0
100.0
50.0
1,000
470
220
220
1,000
470
220
220
1,000
470
220
75
78
78
78
77
80
80
80
77
80
80
80
1,200
1,200
1,200
1,200
600
600
600
600
300
40.0
200.0
100.0
50.0
40.0
200.0
100.0
50.0
12.0
12.0
15.0
300
300
300
200
40.0
220
Notes:
Derating Curve
1. When measuring output ripple, it is recommended that an external ±.47 µF ceramic
capacitor be placed from the +Vout pin to the -Vout pin for single output units and from
each output to common for dual output units. For noise sensitive applications, the use
of 3.3 µF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 0% error band for a load step change of 75%
to 0±±%.
3. Dual output units may be connected to provide a 24 VDC or 3± VDC output. To do this,
connect the load across the positive (+Vout) and negative (-Vout) outputs and float the
output common.
4. The converter should be connected to a low ac-impedance source. An input source with
a highly inductive impedance may affect the stability of the converter. In applications
where the converter output loading is high and input power is supplied over long lines,
it may be necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <0.±⍀ at 0±± kHz) capacitor be
mounted close to the converter. For 02V input units a 0±.± µF is recommended, for 24V
a 4.7 µF and for 48V units a 2.2 µF.
5. It is recommended that a fuse be used on the input of a power supply for protection.
See the table above for the correct rating.
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
1
+VIN
+VIN
11
12
13
15
23
24
No Pin
-VOUT
+VOUT
No Pin
-VIN
Common
No Pin
-VOUT
+VOUT
-VIN
-VIN
-VIN
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±±.±0 (±±.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明