MD112MS-12EHI [MPD]

Miniature, 1W SIP Medical Approved DC/DC Con vert ers;
MD112MS-12EHI
型号: MD112MS-12EHI
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

Miniature, 1W SIP Medical Approved DC/DC Con vert ers

文件: 总3页 (文件大小:452K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series  
MD100MEHI  
Miniature, 1W SIP  
Medical Approved  
DC/DC Converters  
Electrical Specifications  
Key Features:  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
EN 60601 3RD Ed. Approved  
1W Output Power  
Input  
Parameter  
Conditions  
Min.  
4.5  
Typ.  
5.0  
Max.  
5.5  
Units  
5 VDC Input  
4.2 kVAC Isolation  
Input Voltage Range  
12 VDC Input 10.8  
24 VDC Input 21.6  
Capacitor Filter  
12.0  
24.0  
13.2  
26.4  
VDC  
Reinforced Insulation  
1 x MOPP & 2 x MOOP per  
EN 60601-1 3RD Edition &  
ANSI/AAMI ES 60601-1  
2 µA Leakage Current Max  
Compact SIP Case  
Input Filter  
Reflected Ripple Current  
Output  
Parameter  
0.2  
A
Conditions  
Min.  
Typ.  
5.0  
Max.  
Units  
%
Output Voltage Accuracy  
3.3 VOUT  
All Other Models  
3.3/5.0 VOUT  
1.5  
1.2  
20  
Line Regulation  
VIN Change of 1%  
%
%
Load Regulation, See Note 1  
Efficiency  
All Other Models  
15  
Single & Dual Outputs  
3.5 MH MTBF  
See Model Selection Guide  
3.3 VOUT  
All Other Models  
80  
70  
150  
120  
Ripple & Noise (20 MHz), See Note 2  
mV P - P  
Temperature Coefficient  
Output Short Circuit  
General  
0.02  
%/°C  
S
See Note 3  
3.0  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
VAC  
VDC  
µA  
G  
pF  
60 Seconds 4,200  
6,000  
250 VAC, 50/60 Hz  
500 VDC  
Isolation Voltage  
Leakage Current, See Note 4  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
EMI Characteristics, See Note 5  
Parameter  
Radiated Emissions  
Conducted Emissions  
ESD  
2.0  
1.0  
100 kHz, 0.1V  
5
100  
kHz  
Standard  
EN 55022  
EN 55022  
EN 61000-4-2  
Criteria  
Level  
Level B  
Level B  
B
8 kV Contact  
Environmental , See Note 6  
Parameter  
Conditions  
Min.  
Ambient -40  
-55  
Typ.  
Max.  
+85  
+125  
Units  
°C  
°C  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Free Air Convection  
Humidity  
RH, Non-condensing  
95  
%
Physical  
Case Size  
See Mechanical Diagram (Page 3)  
Case Material  
Weight  
Non-Conductive Black Plastic (UL94-V0)  
0.14 Oz (4.2g)  
Reliability Specifications  
Parameter  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign  
Min.  
3.5  
5.0  
5.0  
5.5  
Typ.  
Max.  
Units  
MHours  
mm  
mm  
mm  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
MTBF  
Transformer Creepage  
Transformer Clearance  
PCB Creepage & Clearance  
IEC/EN 60601-1 3RD Edition, 1XMOPP & 2xMOOP  
Safety Approvals, See Note 7  
ANSI/AAMI ES 60601-1 1xMOPP & 2xMOOP Recognition (UL Certificate)  
ANSI/AAMI ES 60601-1, CAN/CSA-C22.2 No.60601-1  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Absolute Maximum Ratings  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
9.0  
Units  
VDC  
°C  
5 VDC Input  
12 VDC Input  
24 VDC Input  
Input Voltage Surge (1 Sec)  
18.0  
30.0  
300  
Lead Temperature  
1.5 mm From Case For 10 Sec  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Capacitive  
Load  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Number  
Current (mA)  
Full-Load No-Load  
Voltage Current  
Current  
(mA, Min)  
(µF, Max)  
(VDC)  
(mA, Max)  
Nominal  
5
Range  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
4.5 - 5.5  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
10.8 - 13.2  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
21.6 - 26.4  
MD105MS-03EHI  
MD105MS-05EHI  
MD105MS-12EHI  
MD105MS-15EHI  
MD105MD-05EHI  
MD105MD-09EHI  
MD105MD-12EHI  
MD105MD-15EHI  
MD112MS-05EHI  
MD112MS-12EHI  
MD112MS-15EHI  
MD112MD-05EHI  
MD112MD-09EHI  
MD112MD-12EHI  
MD112MD-15EHI  
MD124MS-05EHI  
MD124MS-12EHI  
MD124MS-15EHI  
MD124MD-05EHI  
MD124MD-09EHI  
MD124MD-12EHI  
MD124MD-15EHI  
274  
256  
263  
263  
256  
250  
270  
270  
108  
103  
103  
108  
104  
114  
111  
55  
35  
35  
35  
35  
35  
35  
35  
35  
15  
15  
15  
15  
15  
15  
15  
10  
10  
10  
10  
10  
10  
10  
3.3  
5.0  
12.0  
15.0  
5.0  
303.0  
200.0  
84.0  
67.0  
100.0  
56.0  
42.0  
34.0  
200.0  
84.0  
67.0  
100.0  
56.0  
42.0  
34.0  
200.0  
84.0  
67.0  
100.0  
56.0  
42.0  
34.0  
31.0  
20.0  
9.0  
7.0  
10.0  
6.0  
5.0  
4.0  
20.0  
9.0  
7.0  
10.0  
6.0  
5.0  
4.0  
20.0  
9.0  
7.0  
10.0  
6.0  
5.0  
4.0  
1,000  
1,000  
470  
470  
470  
470  
220  
220  
1,000  
470  
470  
470  
470  
220  
220  
1,000  
470  
470  
470  
470  
220  
220  
73  
78  
76  
76  
78  
80  
74  
76  
77  
81  
81  
77  
80  
73  
75  
76  
78  
78  
75  
79  
76  
76  
500  
500  
500  
500  
500  
500  
500  
500  
200  
200  
200  
200  
200  
200  
200  
100  
100  
100  
100  
100  
100  
100  
5
5
5
5
5
5
5
12  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
24  
9.0  
12.0  
15.0  
5.0  
12.0  
15.0  
5.0  
9.0  
12.0  
15.0  
5.0  
12.0  
15.0  
5.0  
9.0  
12.0  
15.0  
53  
53  
55  
53  
55  
55  
Notes:  
6. All models operate to 85ºC ambient without derating. They are not specified for operation over  
85ºC. Contact the factory for more information.  
7. The safety certification (EN 60601) and 1xMOPP & 2xMOOP rating is for a system input  
voltage within 250 VAC, 50/60 Hz.  
1. Output load regulation is specified for a load change of 10% to 100%.  
2. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor and a  
10 µF electrolytic capacitor be connected in parallel from the +VOUT pin to the -VOUT pin for single output  
models, or from each output to common for dual output models.  
8. Operation at no-load will not damage these units. However, they may not meet all  
specifications.  
9. It is recommended that a fuse be used on the input of a power supply for protection.  
See the table above for the correct rating.  
3. In the event of an output short circuit that lasts less than 3 seconds, the unit must be restarted.  
4. Patient leakage current and reinforced insulation is based on a 250 VAC, 50/60 Hz system  
input voltage.  
5. These converters operate without external components. However, to meet specific EMC standards,  
some external components may be required. Typical connections are shown below.  
Typical Connection, Single Output Models  
Typical Connection, Dual Output Models  
These converters are specified for operation without external components. However, in some applications the addition of  
input/output capacitors will enhance stability and reduce output ripple. For applications that require this, the diagrams above  
illustrates a typical connection of the MD100Mx-xxEHIseries.Suggested component values are given in the table at right.  
VIN  
C1  
VOUT  
3.3 VDC  
5.0 VDC  
12 VDC  
15 VDC  
C2  
C3  
---  
5 VDC  
12 VDC  
24 VDC  
10 µF/50V  
4.7 µF/50V  
2.2 µF/50V  
10 µF  
10 µF  
2.2 µF  
1.0 µF  
---  
Capacitors C2 and C3 are not required to meet specifications, but may be used if a lower level of output ripple is required.  
---  
---  
5.0 VDC 4.7 µF  
9.0 VDC 2.2 µF  
12 VDC 1.0 µF  
15 VDC 1.0 µF  
4.7 µF  
2.2 µF  
1.0 µF  
1.0 µF  
Typical Connection, EMI Input Filter  
For applications that require meeting EMC standards, the diagram at left  
illustrates a typical connection of the MD100Mx-xxEHI series. Suggested  
component values are given in the table at below.  
The value for capacitor C2 is given above.  
VIN  
C4  
L1  
C5  
5 VDC  
12 VDC  
24 VDC  
4.7 µF/50V  
4.7 µF/50V  
4.7 µF/50V  
6.8 µH 4.7 µF/50V  
6.8 µH 4.7 µF/50V  
6.8 µH 4.7 µF/50V  
Page 2  
We Power Your Success - For Less  
www.micropowerdirect.com  
Typical Efficiency vs Output, Nom Input  
Typical Efficiency vs Output, Nom Input  
Typical Efficiency vs Input, Full Load  
Typical Efficiency vs Input, Full Load  
Mechanical Dimensions  
Pin Connections  
Pin  
1
Single  
+VIN  
Dual  
+VIN  
2
-VIN  
-VIN  
5
-VOUT  
No Pin  
+VOUT  
-VOUT  
Common  
+VOUT  
6
7
Mechanical Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.02 ( 0.50)  
MicroPow
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MD112MS-15EHI

Miniature, 1W SIP Medical Approved DC/DC Con vert ers
MPD

MD112MS05HI

MD100MHI SERIES
MPD

MD112MS12HI

MD100MHI SERIES
MPD

MD112MS15HI

MD100MHI SERIES
MPD

MD112S-03VHI

Miniature 1W, SIP, Very High Isolation DC/DC Con vert ers
MPD

MD112S-05T

Isolated, 1W SIP, High Temperature DC/DC Converters
MPD

MD112S-05TI

3 kVDC Isolation, 1W High Temperature, SIP DC/DC Converters
MPD

MD112S-05VHI

Miniature 1W, SIP, Very High Isolation DC/DC Con vert ers
MPD

MD112S-09VHI

Miniature 1W, SIP, Very High Isolation DC/DC Con vert ers
MPD

MD112S-12T

Isolated, 1W SIP, High Temperature DC/DC Converters
MPD

MD112S-12TI

3 kVDC Isolation, 1W High Temperature, SIP DC/DC Converters
MPD

MD112S-12VHI

Miniature 1W, SIP, Very High Isolation DC/DC Con vert ers
MPD