MD612D-15RW [MPD]

2:1 Input, 6W SIP, Single & Dual Output DC/DC Converters;
MD612D-15RW
型号: MD612D-15RW
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

2:1 Input, 6W SIP, Single & Dual Output DC/DC Converters

文件: 总4页 (文件大小:808K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MD600xRWSeries  
2:1 Input, 6W SIP,  
Single & Dual Output  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Key Features:  
6W Output Power  
Conditions  
Min.  
4.5  
9.0  
Typ.  
5.0  
12.0  
24.0  
48.0  
30  
Max.  
9.0  
18.0  
36.0  
75.0  
Units  
5 VDC Input  
12 VDC Input  
24 VDC Input 18.0  
48 VDC Input 36.0  
Miniature SIP Case  
2:1 Input Voltage Range  
1,500 VDC Isolation  
36 Standard Models  
Short Circuit Protected  
-40°C to +65°C Operation  
Single & Dual Outputs  
Industry Standard Pin-Out  
Input Voltage Range  
VDC  
Input Reflected Ripple Current  
Start Up Time  
Input Filter  
Output  
Parameter  
Output Voltage Accuracy  
Line Regulation  
Load Regulation  
mA P - P  
mS  
See Note 1  
30  
Capacitor Filter  
Conditions  
Min.  
Typ.  
1.0  
Max.  
Units  
%
%
%
%
mV P - P  
mSec  
%
VIN = Min to Max  
IOUT = 0% to 100%  
See Note 2  
0.2  
1.0  
5.0  
75  
Cross Regulation  
Ripple & Noise (20 MHz)  
Transient Recovery Time  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
General  
See Note 3  
0.5  
See Note 4  
3.0  
0.02  
%/°C  
Continuous (Autorecovery)  
Parameter  
Isolation Voltage  
Conditions  
Min.  
60 Seconds 1,500  
1.0  
Typ.  
Max.  
Units  
VDC  
G  
pF  
kHz  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
EMI Characteristics  
Parameter  
50  
100  
Standard  
Level  
Radiated Emissions  
Conducted Emissions  
EN 55022  
EN 55022  
Class A  
Class A  
See Note 4 Pg 3  
Criteria A; 8 kV Air  
Criteria A; 6 kV Contact  
Criteria A; 10V/m  
ESD  
EN 61000-4-2  
RS  
EFT  
Surge  
CS  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
EN 61000-4-8  
See Note 6 Pg 3  
See Note 6 Pg 3  
Criteria A; 2 kV  
Criteria A; 1 kV  
Criteria A; 10 Vrms  
Criteria A; 1A/m  
PFMF  
Environmental  
Parameter  
Conditions  
Min.  
-40  
Typ.  
+25  
Max.  
+65  
+105  
+125  
Units  
°C  
°C  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Ambient  
Case  
-55  
°C  
Free Air Convection  
RH, Non-condensing  
Humidity  
95  
%
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Physical  
Case Size  
Case Material  
Weight  
Reliability Specifications  
Parameter  
MTBF  
See Mechanical Drawing (Page 4)  
Non-Conductive Black Plastic (UL94-V0)  
0.166 Oz (4.8g)  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign  
Min.  
770  
Typ.  
Typ.  
Max.  
Units  
kHours  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Absolute Maximum Ratings  
Parameter  
Conditions  
5 VDC Input  
Min.  
Max.  
15.0  
25.0  
50.0  
100.0  
260  
Units  
VDC  
°C  
12 VDC Input  
24 VDC Input  
48 VDC Input  
Input Voltage Surge (1 Sec)  
Lead Temperature  
1.5 mm From Case for 10 Sec  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Fuse  
Rating  
Capacitive  
Load  
Model  
Number  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Current (mA)  
Full-Load No-Load  
Voltage Current  
Current  
(mA, Min)  
Slow-Blow  
(mA)  
F, Max)  
(VDC)  
(mA, Max)  
Nominal  
5
Range  
MD605S-03RW  
MD605S-05RW  
MD605S-09RW  
MD605S-12RW  
MD605S-15RW  
MD605S-24RW  
MD605D-05RW  
MD605D-12RW  
MD605D-15RW  
MD612S-03RW  
MD612S-05RW  
MD612S-09RW  
MD612S-12RW  
MD612S-15RW  
MD612S-24RW  
MD612D-05RW  
MD612D-12RW  
MD612D-15RW  
MD624S-03RW  
MD624S-05RW  
MD624S-09RW  
MD624S-12RW  
MD624S-15RW  
MD624S-24RW  
MD624D-05RW  
MD624D-12RW  
MD624D-15RW  
MD648S-03RW  
MD648S-05RW  
MD648S-09RW  
MD648S-12RW  
MD648S-15RW  
MD648S-24RW  
MD648D-05RW  
MD648D-12RW  
MD648D-15RW  
4.5 - 9.0  
4.5 - 9.0  
1,144  
1,519  
1,445  
1,428  
1,428  
1,428  
1,481  
1,428  
1,428  
470  
105  
105  
105  
105  
105  
105  
105  
105  
105  
55  
3.3  
5.0  
1,300  
1,200  
666  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
75  
79  
83  
84  
84  
84  
81  
84  
84  
76  
83  
84  
85  
85  
86  
82  
84  
86  
78  
83  
85  
85  
87  
87  
82  
84  
84  
76  
80  
85  
84  
86  
84  
82  
85  
85  
6,600  
3,300  
2,000  
1,600  
1,400  
680  
3,000  
3,000  
3,000  
3,000  
3,000  
3,000  
3,000  
3,000  
3,000  
1,250  
1,250  
1,250  
1,250  
1,250  
1,250  
1,250  
1,250  
1,250  
750  
5
5
4.5 - 9.0  
9.0  
5
4.5 - 9.0  
12.0  
15.0  
24.0  
5.0  
500  
5
4.5 - 9.0  
400  
5
4.5 - 9.0  
250  
5
4.5 - 9.0  
600  
2,000  
900  
5
4.5 - 9.0  
12.0  
15.0  
3.3  
250  
5
4.5 - 9.0  
200  
660  
12  
12  
12  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
48  
48  
48  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
1,300  
1,200  
666  
6,600  
3,300  
2,000  
1,600  
1,400  
680  
602  
55  
5.0  
595  
55  
9.0  
588  
55  
12.0  
15.0  
24.0  
5.0  
500  
588  
55  
400  
581  
55  
250  
609  
55  
600  
2,000  
900  
595  
55  
12.0  
15.0  
3.3  
250  
581  
55  
200  
660  
229  
30  
1,300  
1,200  
666  
6,600  
3,300  
2,000  
1,600  
1,400  
680  
301  
30  
5.0  
750  
294  
30  
9.0  
750  
294  
30  
12.0  
15.0  
24.0  
5.0  
500  
750  
287  
30  
400  
750  
287  
30  
250  
750  
304  
30  
600  
2,000  
900  
750  
297  
30  
12.0  
15.0  
3.3  
250  
750  
297  
30  
200  
660  
750  
117  
15  
1,300  
1,200  
666  
6,600  
3,300  
2,000  
1,600  
1,400  
680  
300  
156  
15  
5.0  
300  
147  
15  
9.0  
300  
149  
15  
12.0  
15.0  
24.0  
5.0  
500  
300  
145  
15  
400  
300  
148  
15  
250  
300  
152  
15  
600  
2,000  
900  
300  
147  
15  
12.0  
15.0  
250  
300  
147  
15  
200  
660  
300  
Derating Curve  
For Remote Control option, add suffix “R” to  
model number (i.e. MD624S-05RW-R)  
Notes:  
1. Start up time is specified at nominal input and with a constant resistive  
load.  
2. Cross regulation is measured by monitoring one output set at 100% load  
while varying the second output from 25% to 100% load.  
3. When measuring output ripple & noise, it is recommended that an external  
ceramic capacitor (0.1 µF typ.) be placed from the +VOUT to the -VOUT pins for  
single output units and from each output to common for dual output models.  
4. Transient recovery is measured to within a 1% error band for a load step  
change of 25%.  
5. Free air convection is typically 30 - 65 LFM.THe units should not be operated  
in still air (0 LFM).  
6. Exceeding the absollute ratings could damage the unit.  
7. It is recommended that a fuse be used on the input of a power supply for protection.  
See the Model Selection table above for the correct rating.  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com  
Typical Connection  
www.micropowerdirect.com  
For applications that require meeting EMC standards,the diagram above 5. Recommended values for components are:  
7. The output filtering capacitor (C6) is a high frequency, low  
resistance electrolytic capacitor. Care must be taken in  
choosing this capacitor not to exceed the capacitive load  
specification for the unit. Voltage derating of capacitors  
should be 80% or above  
8. The drawings below show typical board layouts for the EMI  
circuit shown above (one for single output models and one  
for dual output units).  
9. In many applications simply adding input/output  
capacitors will enhance the input surge protection  
and reduce output ripple sufficiently. The value of  
the input capacitor can range from 220 µF to 330 µF,  
depending on the needs of the application. The output  
capacitor would typically be 10 µF.  
illustrates a typical connection of the MD600xRW series. The units  
do not require external components to operate as specified.Some notes  
on this diagram (starting with the input circuit) are:  
Component  
5 VIN  
12 VIN  
24 VIN  
48 VIN  
C1  
C2  
LDM1  
C3  
C4  
C5  
220 µF/25V  
22 µF/25V  
10 µH  
10 µF/50V  
10 µH  
10 µF/50V  
10 µF/50V 2.2 µF/100V  
10 µH 15 µH  
10 µF/50V 2.2 µF/100V  
1. An external fuse should be used in all power module applications.  
The recommended fuse is shown in the model chart on page 2.  
2. To protect against a surge,an external MOV is recommended on the  
input. For a suggested value, contact the factory.  
3. To protect against voltage spikes, it is recommended that a TVS be  
used on the input. For a suggested value, contact the factory.  
4. The filtering components shown are needed to meet the conducted  
emissionsrequirementsforEN55022ClassA.Allcomponentsshould  
be mounted as close to the converter as possible.  
22 µF/25V  
220 pF/3 kV 220 pF/3 kV 220 pF/3 kV 220 pF/3 kV  
220 pF/3 kV 220 pF/3 kV 220 pF/3 kV 220 pF/3 kV  
10 µF - 22 µF  
C6  
6. To meet the requirements of EN 61000-4-4 and EN 61000-4-5,an external input capacitor  
is required for all models.The suggested value is 330 µF/100V. Contact the factory  
for more information  
Typical Board Layout: With External Filter Components for Single Output Unit  
Typical Board Layout: With External Filter Components for Dual Output Unit  
MicroPower Direct  
292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com  
Remote ON/OFF Control  
www.micropowerdirect.com  
The MD600x-xxRW is available with an optional remote control input. This input (pin 3) is  
current controlled. The unit operates when this input is open. When the input is “high” (cur-  
rent is flowing into the pin), the converter shuts down. The input current to this pin should be  
kept between 2 mA to 4 mA.  
The diagram at right shows a simple connection for the control pin.  
To order units with the control input, add a “-R” to the model number (i.e. MD605D-12RW-R).  
Remote On/Off  
Parameter  
Supply On  
Supply Off  
Standby Input Current  
Min.  
Typ.  
Open or High Impedance  
mA  
mA  
Max.  
Units  
2
4
2.5  
Mechanical Dimensions  
Pin Connections  
Standard Model  
Remote Control Model  
Pin  
1
Single Output  
-VIN  
Pin  
1
Single Output  
-VIN  
2
+VIN  
2
+VIN  
3
5
6
No Pin  
No Pin  
+VOUT  
3
5
6
Remote On/Off  
No Connection  
+VOUT  
7
-VOUT  
7
-VOUT  
8
No Connection  
8
No Connection  
Pin  
1
Dual Output  
-VIN  
Pin  
1
Dual Output  
-VIN  
2
3
5
6
+VIN  
2
3
5
6
+VIN  
Notes:  
No Connection  
No Connection  
+VOUT  
Remote On/Off  
No Connection  
+VOUT  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.02 ( 0.5)  
Pin 1 is marked by a “dot” or indentation on the top of the unit  
7
8
Common  
-VOUT  
7
8
Common  
-VOUT  
For Remote Control option, add suffix “R” to  
model number (i.e. MD624S-05RW-R)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MD612D-15RWI

2:1 Input, SIP, High Isolation, 6W DC/DC Converters
MPD

MD612S-03RW

2:1 Input, 6W SIP, Single & Dual Output DC/DC Converters
MPD

MD612S-03RWI

2:1 Input, SIP, High Isolation, 6W DC/DC Converters
MPD

MD612S-05RW

2:1 Input, 6W SIP, Single & Dual Output DC/DC Converters
MPD

MD612S-05RWI

2:1 Input, SIP, High Isolation, 6W DC/DC Converters
MPD

MD612S-09RW

2:1 Input, 6W SIP, Single & Dual Output DC/DC Converters
MPD

MD612S-09RWI

2:1 Input, SIP, High Isolation, 6W DC/DC Converters
MPD

MD612S-12RW

2:1 Input, 6W SIP, Single & Dual Output DC/DC Converters
MPD

MD612S-12RWI

2:1 Input, SIP, High Isolation, 6W DC/DC Converters
MPD

MD612S-15RW

2:1 Input, 6W SIP, Single & Dual Output DC/DC Converters
MPD

MD612S-15RWI

2:1 Input, SIP, High Isolation, 6W DC/DC Converters
MPD

MD612S-24RW

2:1 Input, 6W SIP, Single & Dual Output DC/DC Converters
MPD