MD924D-05RU [MPD]
4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers;型号: | MD924D-05RU |
厂家: | MICROPOWER DIRECT, LLC |
描述: | 4:1 Input, 9W SIP, Single & Dual Output DC/DC Con vert ers |
文件: | 总4页 (文件大小:895K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MD900xRUSeries
4:1 Input, 9W SIP,
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
Conditions
24 VDC Input
Min.
Typ.
24.0
48.0
7.0
14.0
50.0
Max.
36.0
75.0
8.9
Units
9.0
• 9W Output Power
Input Voltage Range
VDC
48 VDC Input 18.0
24 VDC Input
48 VDC Input
See Note 2
• Miniature SIP Case
• 4:1 Input Voltage Range
• Short Circuit Protected
• 1,600 VDC Isolation
• Efficiency To 89%
Under Voltage Lockout
VDC
16.0
Start Up Time
Input Reflected Ripple Current
Input Filter
mS
mA P - P
30.0
Capacitor Filter
Output
Parameter
Conditions
Min.
Typ.
Max.
1.0
0.2
1.0
0.5
1.0
5.0
75
Units
%
%
Output Voltage Accuracy
Line Regulation
• Over Voltage Protection
• Over Current Protection
• -40°C to +85°C Operation
• Industry Standard Pin-Out
• Low Cost
VIN = Min to Max
3.3 VOUT Models
Other Single Output Models
Dual Output Models
See Note 4
Load Regulation, See Note 3
%
Cross Regulation
%
mV P - P
µSec
%
%/°C
%
Ripple & Noise (20 MHz)
Transient Recovery Time, See Note 6
Transient Response Deviation
Temperature Coefficient
Over Voltage Protection
Over Current Protection
Output Short Circuit
General
See Note 5
250
25% Load Step Change
3.0
0.02
130
180
%
Continuous (Autorecovery)
Parameter
Conditions Min. Typ.
Max.
Units
Input to Output 1,600
Case To Input or Output 1,000
1,000
Isolation Voltage, See Note 7
VDC
Isolation Resistance
Isolation Capacitance
M
pF
50
24 VIN Models
48 VIN Models
400
500
Switching Frequency
kHz
EMI Characteristics
Parameter
Radiated Emissions, See Note 8
Conducted Emissions, See Note 8
Standard
Criteria
Level
Class A
Class A
EN 55032
EN 55032
ESD
RS
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
B
A
A
A
A
A
6 kV Contact, 8 kV Air
20V/rms
2 kV
2 kV
10 Vrms
100 A/m
EFT, See Note 9
Surge, See Note 10
CS
PFMF
Environmental
Parameter
Conditions
Min.
Typ.
+25
Max.
+85
+100
+125
Units
°C
Ambient
Case
-40
Operating Temperature Range
Storage Temperature Range
Cooling
-55
°C
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Free Air Convection
Humidity
Physical
Case Size
Case Material
Weight
RH, Non-condensing
95
%
See Mechanical Diagram (Page 4)
Black, Anodized Copper (UL94-V0)
0.25 Oz (7.3g)
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Reliability Specifications
Parameter
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
Typ.
Max.
Units
MHours
MTBF
1.0
Absolute Maximum Ratings
Parameter
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
Typ.
Max.
50.0
100.0
260
Units
VDC
°C
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Fuse
Capacitive
Load
Model
Number
Efficiency
(%, Typ)
Rating
Voltage (VDC)
Current (mA)
Full-Load No-Load
Voltage Current
Current
(mA, Min)
Slow-Blow
(mA)
(µF, Max)
(VDC)
(mA, Max)
Nominal
24
Range
MD924S-03RU
MD924S-05RU
MD924S-09RU
MD924S-12RU
MD924S-15RU
MD924S-24RU
MD924D-05RU
MD924D-12RU
MD924D-15RU
MD948S-03RU
MD948S-05RU
MD948S-09RU
MD948S-12RU
MD948S-15RU
MD948S-24RU
MD948D-05RU
MD948D-12RU
MD948D-15RU
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
335
392
426
426
421
421
392
426
431
168
196
216
213
211
211
196
216
216
9
9
9
9
9
9
9
9
9
5
5
5
5
5
5
5
5
5
3.3
5.0
2,000
1,600
1,000
750
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
82
85
88
88
89
89
85
88
87
82
85
87
88
89
89
85
87
87
2,600
1,300
800
2,000
2,000
2,500
2,500
2,500
2,500
2,000
2,500
2,500
1,000
1,000
1,500
1,500
1,500
1,500
1,000
1,500
1,500
24
24
9.0
24
12.0
15.0
24.0
5.0
560
24
600
560
24
375
200
24
800
800
24
12.0
15.0
3.3
375
390
24
300
200
48
2,000
1,600
1,000
750
2,600
1,300
800
48
5.0
48
9.0
48
12.0
15.0
24.0
5.0
560
48
600
560
48
375
200
48
800
800
48
12.0
15.0
375
390
48
300
200
2:1 Input Models Are Also Available
See The MD900xRW
Derating Curve
Notes:
1. The specified maximum capacitive load is for each output.
2. Start up time is specified at the nominal Voltage input and with a constant
resistive load.
3. Load regulation is specified for a load change of 0% to 100%.
4. Cross regulation is specified with one output at full load while the other
output is varied from 25% to 100% load.
5. Output ripple is measured with a 1 μF ceramic capacitor and a 10 μF
electrolytic capacitor connected in parallel.
6. Transient recovery is measured to within a 1% error band for a load
step change of 25%. Single 3.3 & 5 VDC output models have a response
deviation of 5.0% Max.
7. Isolation voltage ratings are for 60 seconds.
8. With the addition of external filter and protection components, all models will
meet the requirements of EN 55032 classA.Suggested input circuits are shown
in the connection diagrams on page 3.Contact the factory for more information.
9. To meet the requirements of EN 61000-4-4 ( 2 kV), external components
are needed.The connection diagrams on page 3 shows external components
that would typically achieve this. Contact the factory for more information.
10. To meet the requirements of EN 61000-4-5 ( 2 kV), external components are
needed. This can be done as shown in the connection diagrams on page 3.
Contact the factory for more information.
11. Operation at no-load will not damage the unit, but they may not meet all
specifications.
12. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Remote ON/OFF Control
The MD900x-RU may be started or shutdown by the control pin
input (pin 3). This input is current controlled. The unit operates
when this input is left open. When the input is “high” (current is
flowing into the pin), the converter shuts down. The input current
to this pin must be kept between 2 mA to 4 mA.
The diagram at right shows a simple input circuit for the control
pin. Closing the switch causes 2 - 4 mA to flow through the 1 k⍀
resister, shutting the unit off.
MicroPower Direct
• 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
For applications that require meeting EMC standards, the diagrams below illustrate typi-
cal connections of the MD900xRU series. Some notes on this diagram (starting with the
input circuit) are:
www.micropowerdirect.com
3. The output filtering components C9 & C11 are high frequency, low ESR electrolytic
capacitors. Capacitors C10 & C12 are ceramic. Care must be taken in choosing
these capacitors not to exceed the capacitive load specification for the unit. Voltage
derating of capacitors should be 80% or above.
1. An external fuse should be used in all power module applications. The recommended
fuse is shown in the model chart on page 2.
2. To protect against voltage spikes, it is recommended that a TVS be used on the input.
A suggested value is given in the tables below.
Typical Connection: 24 VIN, Single Output Models
Recommended component values are:
Component
Value
330 μF/100V
3KW, 70V
1210 106M/35V
20 μH
C1
TVS
C2, C3, C4
L1
L2
C5, C6, C7, C8
C9
20 μH
1808 221K/3kV
10 μF
C10
1 μF
Typical Connection: 24 VIN, Dual Output Models
Component
C1
Value
330 μF/100V
3KW, 70V
1210 106M/35V
20 μH
TVS
C2, C3, C4
L1
L2
20 μH
C5, C6, C7, C8
C9, C11
C10, C12
1808 221K/3kV
10 μF
1 μF
Typical Connection: 48 VIN, Single Output Models
Component
Value
330 μF/100V
3KW, 70V
1210 106M / 35V
132.8 μH
10 μH
C1
TVS
C2, C3, C4
L1
L2
C5, C6, C7, C8
C9
1808 221K/3kV
10 μF
C10
1 μF
Typical Connection: 48 VIN, Dual Output Models
Component
C1
Value
330 μF/100V
3KW, 70V
1210 106M/35V
132.8 μH
10 μH
TVS
C2, C3, C4
L1
L2
C5, C6, C7, C8
C9, C11
C10, C12
1808 221K/3kV
10 μF
1 μF
MicroPower Direct
• 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
www.micropowerdirect.com
Mechanical Dimensions
It is not required that the user connect the case ground
tabs (9 & 10 on the mechanical diagram) to the PCB.
However, connecting one or both tabs to a ground
plane on the PCB will help:
Pin Connections
• Improve the unit’s resistance to vibration
• Improve the unit’s ability to dissipate heat
• Improve the unit’s resistance to ESD
Pin
1
Single Output
-VIN
Pin
1
2
3
6
Dual Output
-VIN
+VIN
Remote On/Off
+VOUT
2
+VIN
Call the factory for more information
3
6
Remote On/Off
+VOUT
7
8
9
10
-VOUT
No Connection
Case
7
8
9
10
Common
-VOUT
Case
Notes:
•
•
•
•
All dimensions are typical in inches (mm)
Pin Section Tolerance x.xxx = 0.004 ( 0.100)
General Tolerance x.xx = 0.01 ( 0.25)
Pin 1 is marked by a “dot” or indentation on the top of the unit
Case
Case
Also Available:
MD900xRW
Key Features:
• 9W Output Power
For those applications that require high power den-
sity, but not a very wide input range, MPD offers the
MD900xRW series. These units also feature high power
density, a very high performance envelope and a wide
range of standard models. However, since thay are 2:1
input designs, they are offered at a lower cost.
• Miniature SIP Case
• 2:1 Input Voltage Range
• 27 Single & Dual Output Models
• 1,600 VDC Isolation
Check them out now, or call the factory for free samples.
• Miniature SIP Case
• -40°C to +85°C Operation
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com