MI648D05ERU [MPD]

MI600ERU SERIES;
MI648D05ERU
型号: MI648D05ERU
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

MI600ERU SERIES

文件: 总2页 (文件大小:312K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series  
MI600ERU  
4:1 Input, 6W  
Ultra-Miniature  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Key Features:  
6W Output Power  
4:1 Input Range  
Input  
Parameter  
Conditions  
24 VDC Input  
Min.  
9.0  
Typ.  
24.0  
48.0  
Max.  
36.0  
75.0  
Units  
Input Voltage Range  
VDC  
48 VDC Input 18.0  
Input Filter  
Output  
Parameter  
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Load Regulation, See Note 1  
Ripple (20 MHz)  
Noise (20 MHz)  
Pi () Filter  
Miniature 1” x 1” Case  
Single & Dual Outputs  
1,500 VDC Isolation  
>1 MHour MTBF  
16 Standard Models  
LOW COST!!  
Conditions  
Min.  
Typ.  
1.0  
0.5  
0.2  
0.5  
15  
Max.  
2.0  
1.5  
0.5  
1.0  
25  
75  
500  
5.0  
Units  
%
%
%
%
mV P - P  
mV P - P  
µSec  
%
%/ºC  
%VOUT  
%IOUT  
Dual Output, Balanced Loads  
Vin = Min to Max  
Iout = 5% to 100%  
See Note 2  
See Note 2  
50  
Transient Recovery Time , See Note 3  
Transient Response Deviation  
Temperature Coefficient  
Output Over Voltage Protection  
Output Over Load Protection  
Output Short Circuit  
General  
300  
3.0  
0.03  
25% Load Step Change  
110  
120  
140  
180  
Continuous (Autorecovery)  
Parameter  
Conditions  
Min.  
60 Seconds 1,500  
500 VDC 1,000  
100 kHz, 1V  
Typ.  
Max.  
Units  
VDC  
M  
pF  
kHz  
Isolation Voltage  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
EMI Characteristics  
Parameter  
Radiated Emissions  
Conducted Emissions  
ESD  
RS  
EFT  
Surge  
CS  
1,000  
300  
Standard  
See Note 4  
Min.  
EN 55022  
Typ.  
Max.  
Class A  
Class A  
Units  
See Note 4  
EN 55022  
EN 61000-4-2  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
EN 61000-4-29  
Criteria B; 4 kV Contact  
Criteria A; 10V/m  
Criteria B; 2 kV  
Criteria B; 2 kV  
Criteria A; 3 Vrms  
Criteria B; 0% - 70%  
See Note 5  
See Note 6  
Voltage Dips  
Environmental  
Parameter  
Conditions  
Min.  
-40  
Typ.  
Max.  
+85  
+105  
+125  
Units  
ºC  
ºC  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Ambient  
Case  
-55  
ºC  
Free Air Convection  
RH, Non-condensing  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Humidity  
95  
%
Physical  
Case Size  
Case Material  
Weight  
1.00 x 1.00 x 0.461 Inches (25.4 x 25.4 x 11.7 mm)  
Aluminum (UL94-V0)  
0.48 Oz (14g)  
T: (781) 344-8226  
F: (781) 344-8481  
Reliability Specifications  
Parameter  
Conditions  
MIL HDBK 217F, 25ºC, Gnd Benign  
Min.  
1.0  
Typ.  
Typ.  
Max.  
Units  
MHours  
E: sales@micropowerdirect.com MTBF  
W: www.micropowerdirect.com  
Absolute Maximum Ratings  
Parameter  
Conditions  
Min.  
Max.  
50.0  
100.0  
300  
Units  
VDC  
ºC  
24 VDC Input -0.7  
48 VDC Input -0.7  
1.5 mm From Case For 10 Sec  
Input Voltage Surge (1 Sec)  
Lead Temperature  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Capacitive  
Load  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Number  
Current (mA)  
Voltage  
(VDC)  
Current  
(mA, Max)  
Current  
(mA, Min)  
F Max)  
Nominal  
24  
Range  
Full-Load No-Load  
MI624S-03ERU  
MI624S-05ERU  
MI624S-12ERU  
MI624S-15ERU  
MI624S-24ERU  
MI624D-05ERU  
MI624D-12ERU  
MI624D-15ERU  
MI648S-03ERU  
MI648S-05ERU  
MI648S-12ERU  
MI648S-15ERU  
MI648S-24ERU  
MI648D-05ERU  
MI648D-12ERU  
MI648D-15ERU  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
261  
301  
287  
284  
284  
301  
287  
284  
130  
151  
143  
142  
142  
151  
143  
142  
7
7
7
7
7
7
7
7
3
3
3
3
3
3
3
3
3.3  
5.0  
12.0  
15.0  
24.0  
5.0  
12.0  
15.0  
3.3  
1,500  
1,200  
500  
400  
250  
600  
250  
200  
1,500  
1,200  
500  
400  
250  
600  
250  
200  
75  
60  
25  
20  
12  
30  
12  
10  
75  
60  
25  
20  
12  
30  
12  
10  
1,800  
1,000  
100  
100  
47  
470  
100  
100  
1,800  
1,000  
100  
100  
47  
79  
83  
87  
88  
88  
83  
87  
88  
79  
83  
87  
88  
88  
83  
87  
88  
1500  
1500  
1500  
1500  
1500  
1500  
1500  
1500  
750  
750  
750  
750  
750  
24  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
48  
48  
5.0  
12.0  
15.0  
24.0  
5.0  
12.0  
15.0  
470  
100  
100  
750  
750  
750  
Notes:  
4. All units are rated for EN 55022 (CE/RE) classA without external components.They will meet class B with the addition  
1. The load regulation of dual output units with unbalanced loads is 5%.  
of the DCFM-01 (or a similar discrete filter circuit). Contact the factory for more information.  
2. When measuring output ripple, it is recommended that an external ceramic capacitor (approx 1 µF to 10 5. The external EMS components shown in the typical connection diagram are required meet EN 61000-4-4, 2 kV.  
µF) be placed from the +Vout pin to the -Vout pin for single output units and from each output to common  
for dual output units.  
The addition of the DCFM-01filter module will bring it to 4 kV. Contact the factory for more information.  
6. The external EMS components shown in the typical connection diagram are required meet EN 61000-4-5, 2 kV.  
This level can also be achieved with the DCFM-01filter module. Contact the factory for more information.  
7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table  
above for the correct rating.  
3. Operation at no-load will not damage these units. However, they may not meet all specifications. The  
recommended minimum load is given in the model selection table above.  
Typical Connection  
The diagram at left illustrates a typical application connection of the  
MI600x-ERW series. Shown are components for external EMI and/  
or EMS circuits. recommended values for the components shown are:  
Output  
Fuse  
MI624x-ERU  
MI648x-ERU  
See Table Above  
MOV  
LDM1  
TVS  
C1  
10D560k  
56 µH  
10D101k  
56 µH  
SMCJ48A  
120 µF/50V  
2.2 µF/50V  
4.7 µH  
SMCJ90A  
120 µF/100V  
2.2 µF/100V  
4.7 µH  
C2  
LDM2  
CY1  
Typical Board Layout: With DCFM-01 Input Module (See note at right)  
1000 pF/2000V  
1000 pF/2000V  
1000 pF/2000V  
1000 pF/2000V  
CY2  
Input noise and surge suppression modules are available for a number of  
MPD DC/DC converters.An MI600xERU connection with the DCFM-01/02 is  
illustrated in the diagram at left.For pricing or full technical information on these  
modules (DCFM-01 and DCFM-02) please contact the factory.  
Pin Connections  
Pin Single  
Dual  
Pin  
Single  
Dual  
1
2
+VIN  
-VIN  
+VIN  
-VIN  
3
4
5
+VOUT  
No Pin  
-VOUT  
+VOUT  
Common  
-VOUT  
Derating Curve  
Mechanical Dimensions  
Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.01 ( 0.25)  
Pin 1 is marked by a “dot” on the top of the unit  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MI648D05ERW

MI600ERW SERIES
MPD

MI648D12ERU

MI600ERU SERIES
MPD

MI648D12ERW

MI600ERW SERIES
MPD

MI648D15ERU

MI600ERU SERIES
MPD

MI648D15ERW

MI600ERW SERIES
MPD

MI648S03ERU

MI600ERU SERIES
MPD

MI648S03ERW

MI600ERW SERIES
MPD

MI648S05ERW

MI600ERW SERIES
MPD

MI648S12ERU

MI600ERU SERIES
MPD

MI648S12ERW

MI600ERW SERIES
MPD

MI648S15ERU

MI600ERU SERIES
MPD

MI648S15ERW

MI600ERW SERIES
MPD