MPM-07S Series  
Compact 1 x 2 Inch  
7W, Single Output  
AC/DC Power Supplies  
Electrical Specifications  
Key Features:  
7W Output Power  
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Conditions  
Min.  
85  
47  
Typ.  
Max.  
265  
440  
Units  
VAC  
Hz  
Compact 1 x 2 Inch Case  
Universal 85-265 VAC Input  
EN60950 Approved  
Input Voltage Range  
Input Frequency  
Input Current  
See Model Selection Guide  
Meets EN55022 B  
115 VAC  
230 VAC  
10.0  
20.0  
Inrush Current  
A Pk  
Meets IEC Safety Class II  
>280 kHour MTBF  
EMI  
Meets CISPR Pub. 22/FCC Class B  
115 VAC  
230 VAC  
0.1  
0.3  
Safety Ground Leakage Current  
mA  
Output  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
Output Voltage  
Output Current  
Output Voltage Accuracy  
Line Regulation  
Load Regulation  
See Model Selection Guide  
See Model Selection Guide  
1.0  
2.0  
1.0  
1.0  
1.8  
1.0  
%
%
%
VIN = Min to Max  
IO = Min to Max  
0.5  
0.5  
3.3 & 5.0 VDC Output  
All Other Outputs  
115 VAC, 60 Hz  
1.5  
0.8  
15  
Ripple & Noise (20 MHz)  
%VP-P of VO  
Hold-Up Time  
mSec  
%/°C  
% of VO  
Temperature Coefficient  
Over Voltage Protection  
Short Circuit Protection, Note 3  
Overload Protection, Note 4  
General  
0.02  
120  
Zener Diode Clamp  
Continuous (Autorecovery)  
Typ. 120% to 180% of Output Power  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
VAC  
VAC  
MΩ  
Isolation Voltage  
Isolation Test Voltage  
Isolation Resistance  
EMI/RFI  
Input to Output 3,000  
Input to Output, Flash Tested For 60S 4,700  
500 VDC  
Conducted  
100  
EN 55022 Level B  
Electrostatic Discharge (ESD)  
RF Field Susceptibility  
Electrical Fast Transients/Bursts On Mains  
IEC/EN 61000-4-2 Level B  
IEC/EN61000-4-3  
IEC/EN 61000-4-4 Level 3 2 kV  
EMC Compliance  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Surge IEC/EN 61000-4-5 Level 3 1kV/2 kV  
Switching Frequency  
Environmental  
Parameter  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Humidity  
Physical  
Case Size  
100  
kHz  
Conditions  
Min.  
-25  
Typ.  
+25  
Max.  
+71  
Units  
°C  
Ambient  
-40  
+85  
°C  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Free Air Convection (See Derating Curve)  
RH, Non-condensing 95  
%
2.00 x 1.00 x 0.76 Inches (50.8 x 25.4 x 19.3 mm)  
Non-Conductive Plastic& Fiberglass (UL94-V0)  
1.55 Oz (44g)  
Case Material  
Weight  
Reliability Specifications  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
MTBF  
MIL HDBK 217F, 25°C, Gnd Benign  
280  
kHours  
Safety Standards  
Safety Approvals  
Safety Class  
IEN 60950, IEC 60950  
IEN 60950, IEC 60950  
IEC 61140 Class II  
Model Selection Guide  
Input  
Output 1 (Vout 1)  
Current (A)  
Fuse  
Rating  
Slow-Blow  
(mA)  
Capacitive  
Load  
(µF Max)  
Model  
Current (A)  
Efficiency  
(%, Typ)  
Voltage  
Number  
(VDC)  
115 VAC 230 VAC  
Max.  
Min.  
MPM-07S-03  
MPM-07S-05  
MPM-07S-12  
MPM-07S-15  
MPM-07S-24  
0.96  
0.139  
0.130  
0.130  
0.130  
0.051  
0.051  
0.051  
0.051  
0.051  
3.3  
1.400  
1.400  
0.583  
0.466  
0.291  
0.140  
0.140  
0.058  
0.047  
0.029  
70  
73  
78  
78  
78  
2,200  
2,200  
1,000  
1,000  
680  
1,500  
1,500  
1,500  
1,500  
1,500  
5.0  
12.0  
15.0  
24.0  
Other outputs may be available  
Contact the factory for details at:  
sales@micropowerdirect.com  
Derating Curve  
Notes:  
1. Load regulation is measured for an output change of 0%  
to 100% at nominal input line.  
2. Operation at no-load will not damage these units. How-  
ever, they may not meet all specifications.  
3. Output short circuit protection is provided by a “hiccup  
mode” circuit. The unit recovers automatically when the  
fault condition is removed.  
4. Output overload protection is provided by a fold back  
current limiting circuit.  
5. It is recommended that an external slow blow fuse also  
be used on the input for protection. See the table above  
for the correct rating.  
Mechanical Dimensions  
Pin Connections  
Pin  
Function  
1
2
3
4
AC-Neutral  
AC-Line  
+Vout  
-Vout  
Notes:  
All dimensions are typical in inches (mm)  
MicroPower Direct
Tolerance x.xx = 0.01 ( 0.25)  
www.micropowerdirect.com  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MPM-07S-05

Compact 1 x 2 Inch 7W, Single Output AC/DC Power Supplies
MPD

MPM-07S-12

Compact 1 x 2 Inch 7W, Single Output AC/DC Power Supplies
MPD

MPM-07S-15

Compact 1 x 2 Inch 7W, Single Output AC/DC Power Supplies
MPD

MPM-07S-24

Compact 1 x 2 Inch 7W, Single Output AC/DC Power Supplies
MPD

MPM-10

Compact, 10W PC Mount Single, Dual & Triple Out AC/DC Power Supplies
MPD

MPM-10

10W High Reliable Green Medical Encapsulated Type
MEANWELL

MPM-10-12

10W High Reliable Green Medical Encapsulated Type
MEANWELL

MPM-10-15

10W High Reliable Green Medical Encapsulated Type
MEANWELL

MPM-10-24

10W High Reliable Green Medical Encapsulated Type
MEANWELL

MPM-10-3.3

10W High Reliable Green Medical Encapsulated Type
MEANWELL

MPM-10-5

10W High Reliable Green Medical Encapsulated Type
MEANWELL

MPM-10D-05

Compact, 10W PC Mount Single, Dual & Triple Out AC/DC Power Supplies
MPD