MPM-10D-05 [MPD]
Compact, 10W PC Mount Single, Dual & Triple Out AC/DC Power Supplies; 结构紧凑, 10W的PC安装单,双和三输出AC / DC电源型号: | MPM-10D-05 |
厂家: | MICROPOWER DIRECT, LLC |
描述: | Compact, 10W PC Mount Single, Dual & Triple Out AC/DC Power Supplies |
文件: | 总2页 (文件大小:186K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MPM-10 Series
Compact, 10W PC Mount
Single, Dual & Triple Out
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 10W Output Power
• Universal 85-264 VAC Input
• EN 60950 Approved
• Single, Dual & Triple Outputs
• Meets EN55022 B
Parameter
Conditions
Min.
85
120
47
Typ.
Max.
264
370
63
Units
VAC
VDC
Hz
Input Voltage Range
Input Frequency
Input Current
See Model Selection Guide
115 VAC
230 VAC
10.0
20.0
Inrush Current
A Pk
• >200 kHour MTBF
EMI
Meets CISPR Pub. 22/FCC Class B
• Compact PC Mount Case
115 VAC
230 VAC
0.1
0.3
Safety Ground Leakage Current
mA
Output
Parameter
Conditions
Min.
Typ.
Max.
Units
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
See Model Selection Guide
See Model Selection Guide
2.0
0.5
See Model Selection Guide
%
50
20
80
mV Pk - Pk
mSec
115 VAC
230 VAC
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Overload Protection
General
0.02
%/°C
Continuous (Autorecovery)
Typ. 110% of Output Power
Parameter
Conditions
Min.
Typ.
Max.
Units
Input to Output 3,000
Input to Ground 1,500
Isolation Voltage
EMI/RFI
VAC
Output to Ground
Conducted
500
EN 55022 Level B
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
IEC/EN 61000-4-2 Level 3 6kV/8kV
IEC/EN61000-4-3
EMC Compliance
IEC/EN 61000-4-4 Level 3 2 kV
Surge IEC/EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency
Environmental
Parameter
150
kHz
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conditions
Min.
-25
Typ.
+25
Max.
+70
+90
Units
°C
°C
Ambient
Case
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
-25
+105
°C
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Free Air Convection (See Derating Curve)
RH, Non-condensing 85
%
2.16 x 1.77 x 0.81 Inches (55.0 x 45.0 x 20.5 mm)
Non-Conductive Black Plastic (UL94-V0)
4.23 Oz (120g)
Case Material
Weight
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
200
kHours
Safety Standards
Safety Approvals, See Note 3
IEN 60950, IEC 60950
IEN 60950, IEC 60950
Model Selection Guide
Input
Output 1 (Vout 1)
Current (A)
Output 2 (Vout 2)
Output 3 (Vout 3)
Current (A)
Model
Number
Efficiency
(%, Typ)
Current (A)
Current (A)
Over Volt.
Protection
(VDC)
Over Volt.
Voltage
(VDC)
Voltage
(VDC)
Voltage
Load
Load
Reg.
Load
Reg.
Protection
(VDC)
115 VAC 230 VAC
Typ.
Typ.
Typ.
(VDC)
Reg.
MPM-10S-03
MPM-10S-05
MPM-10S-09
MPM-10S-12
MPM-10S-15
MPM-10S-24
MPM-10D-05
MPM-10D-12
MPM-10D-15
MPM-10ID-0505 0.23
MPM-10ID-0512 0.23
MPM-10ID-0515 0.23
MPM-10ID-0524 0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
3.3
5.0
9.0
2.00
2.00
1.10
0.90
0.70
0.45
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
2.0%
2.0%
2.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
6.5
6.5
68
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
12.0
20.0
20.0
30.0
6.5
20.0
20.0
6.5
6.5
6.5
6.5
6.5
12.0
15.0
24.0
+5.0 +1.00
+12.0 +0.45
+15.0 +0.35
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
-5.0 -1.00
-12.0 -0.45
-15.0 -0.35
2.0%
2.0%
2.0%
5.0%
5.0%
5.0%
5.0%
5.0%
5.0%
5.0%
5.0%
6.5
20.0
20.0
6.5
20.0
20.0
30.0
1.80
1.50
1.40
1.00
1.80
1.60
1.40
1.00
5.0
12.0
15.0
24.0
0.20
0.20
0.20
0.20
MPM-10T-0505
MPM-10T-0512
MPM-10T-0515
MPM-10T-0524
Notes:
0.23
0.23
0.23
0.23
+5.0 +0.10
+12.0 +0.10
+15.0 +0.10
+24.0 +0.10
-5.0 -0.10
-12.0 -0.10
-15.0 -0.10
-24.0 -0.10
5.0%
5.0%
5.0%
5.0%
6.5
6.5
6.5
Typical Connection
1. Load regulation is measured for an output change of 10% to 90% at
nominal input line. For multiple output models, the loads are balanced.
2. The MPM-10 series is specified for operation over the wide operating
temperature range of -25°C to +55°C without derating. For operation
over +55°C, derate the power linearly by 3.75%/°C from +55°C to +70°C.
3. Model numbers MPM-10ID-05xx are dual isolated units (Dual ISO). The
outputs on these models are isolated from each other.
4. Single, dual&dualisolatedoutputmodelsareapprovedtoEN60950. Approval
for other models is pending.
5. It is recommended that a fuse be used on the input of a power supply
for protection. For the MPM-10 series, a 2A/250 VAC slow blow should
be used.
Mechanical Dimensions
Typical Component Values
Vout
3.3
C1, C3, C5
330 ~ 1,000 µF/16V
330 ~ 1,000 µF/16V
220 µF/25V
C2, C4, C6
Fuse
TVS
P6KE6.8A
P6KE6.8A
P6KE16A
P6KE20A
P6KE33A
5.0
2A/
250 VAC
Slow Blow
0.1 µF/50V
12.0
15.0
24.0
Notes:
Ceramic
220 µF/25V
120 µF/35V
1. C1, C3 and C5 are high frequency, low resistance electrolytic capacitors. Refer to the suppli-
ers specifications for capacitance/current ratings.
2. Voltage derating on all capacitors should be 80% or higher.
3. C2, C4 and C6 eliminate high frequency noise.
4. The TVS is recommended to protect load circuitry in the event of a module failure.
Pin Connections
Pin
Single
Dual
Dual ISO
Triple
1
2
3
4
5
6
7
8
AC-Ground AC-Ground AC-Ground AC-Ground
AC-Neutral AC-Neutral AC-Neutral AC-Neutral
AC-Line
-Vo 1
AC-Line
-Vo 2
AC-Line
-Vo 1
AC-Line
-Vo 1
No Pin
No Pin
No Pin
+Vo 1
No Pin
Common
No Pin
+Vo 1
+Vo 1
No Pin
-Vo 2
+Vo 1
-Vo 2
Common
+Vo 2
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.25)
+Vo 2
MicroPower Direct
•
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
©2020 ICPDF网 联系我们和版权申明