MPM-20SV-24 [MPD]

20W Output Power;
MPM-20SV-24
型号: MPM-20SV-24
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

20W Output Power

文件: 总4页 (文件大小:899K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series  
MPM-20SV  
85 to 305 VAC Input, 20W  
Miniature PC Mount  
AC/DC Power Supplies  
Electrical Specifications  
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Key Features:  
Input  
20W Output Power  
Universal 85-305 VAC Input  
EN 60950 Approved  
Six Single Output Models  
Meets EN 55022 B  
Parameter  
Conditions  
Min.  
85  
Typ.  
Max.  
305  
430  
63  
Units  
VAC  
VDC  
Hz  
Input Voltage Range  
100  
47  
Input Frequency  
Input Current  
See Model Selection Guide  
115 VAC  
230 VAC  
15.0  
Inrush Current  
A Pk  
>300 kHour MTBF  
30.0  
0.3  
Leakage Current  
Output  
230 VAC/50 Hz  
mA rms  
Compact PC Mount Case  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
Output Voltage  
See Model Selection Guide  
See Model Selection Guide  
Output Current  
Output Trim Range  
Minimum Load  
10  
%
0
%
Output Voltage Accuracy  
Line Regulation  
Load Regulation  
Ripple & Noise (20 MHz)  
2.0  
%
VIN = Min to Max  
See Note 2  
See Note 3  
115 VAC  
0.5  
1.0  
50  
%
%
100  
mV Pk - Pk  
15  
Hold-Up Time  
mSec  
%/°C  
230 VAC  
80  
Temperature Coefficient  
Short Circuit Protection  
Overload Protection  
General  
0.02  
Continuous (Autorecovery)  
Autorecovery 110  
%
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
VAC  
kHz  
Input to Output, 60S 3,000  
Input to FG, 60S 2,000  
Isolation Voltage  
Switching Frequency  
Environmental  
Parameter  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
65  
Conditions  
Min.  
-40  
Typ.  
+25  
Max.  
+70  
Units  
°C  
Ambient  
-40  
+105  
°C  
Free Air Convection (See Derating Curve)  
RH, Non-condensing 95  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Humidity  
%
Physical  
Case Size  
See Mechanical Diagram On Page 4  
Case Material  
Weight  
Non-Conductive Black Plastic (UL94-V0)  
4.22 Oz (120g)  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Reliability Specifications  
Parameter  
MTBF  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign  
Wave Solder  
Min.  
300  
Typ.  
Max.  
Units  
kHours  
260  
360  
Lead Temperature, See Note 4  
°C  
Hand Solder  
Safety Standards  
Safety Class  
UL 60950, EN 60950  
Class I  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Over Volt. Capacitive  
Efficiency  
Model  
Number  
Current (A)  
Protection  
(VDC)  
Load  
F, Max)  
Voltage  
(VDC)  
Current  
(A Max.)  
Power  
(W)  
(%, Typ)  
115 VAC  
0.60  
230 VAC  
MPM-20SV-03  
MPM-20SV-05  
MPM-20SV-09  
MPM-20SV-12  
MPM-20SV-15  
MPM-20SV-24  
0.34  
0.34  
0.34  
0.34  
0.34  
0.34  
3.3  
5.0  
3.50  
3.50  
2.10  
1.60  
1.30  
0.85  
11.5  
17.5  
20.0  
20.0  
20.0  
20.0  
7.5  
7.5  
48,000  
12,240  
5,600  
5,400  
2,400  
1,840  
75  
78  
79  
83  
84  
85  
0.60  
0.60  
9.0  
12.0  
20.0  
20.0  
30.0  
0.60  
12.0  
15.0  
24.0  
0.60  
0.60  
Notes:  
5. All units are rated for EN 55022 (CE/RE) class B without  
external components.  
6. All units are rated for EN 61000-4-4 ( 2 kV) with the addi-  
tion of the MOV shown in the typical connection below. They  
will meet EN 61000-4-4 ( 4 kV) with the additional input  
components shown in the typical connection diagram shown  
on page 3.  
7. All units are rated for EN 61000-4-5 ( 1 kV/ 2 kV) with the addi-  
tion of the MOV shown in the typical connection below. They will  
meet EN 61000-4-5 ( 2 kV / 4 kV) with the input components  
shown in the typical connection diagram on page 3.  
8. It is recommended that a fuse be used on the input of a power  
supply for protection. For the MPM-20SV-xx series, a  
3.15A/300 VAC slow blow should be used.  
1. Operation at no load will not damage the units, however, they  
may not meet all specifications.  
MPD offers a wide variety of input protection and  
filtering modules for use with our AC & DC power  
modules. The MACFM-02A may be used with  
the MPM-20SV, as shown on page. Full data-  
sheets for all our input modules are available on  
our website, or call the factory for a more help.  
2. Load regulation is measured for an output change of 10% to  
100% at nominal input line.  
3. When measuring output ripple, it is recommended that an  
external 0.1 µF high frequency ceramic capacitor be placed  
in parallel with a 47 µF high frequency electrolytic capacitor  
from the +VOUT pin to the -VOUT pin.  
4. The max lead temp for wave soldering is 5% for a time  
period of 5 to 10S. For hand soldering, it is 10% for 3 to 5S.  
Typical Connection  
The diagram above illustrates a typical application connection of the MPM-20SV series. Notes on this circuit (starting with the input circuit) are:  
1. It is recommended that an external fuse and NTC be used. The 5. If output noise levels lower than the specified limits are required,  
Model  
C1  
C2  
TVS  
recommended fuse is a 3.15A/300 VAC slow blow.  
2. All units are rated for EN 55022 (CE/RE) class B without external  
components.  
3. All units are rated for EN 61000-4-4 ( 2 kV) with the addition of  
the MOV shown in the typical connection above. They will meet  
the addition of C1 and C2 should be sufficient for most applications.  
The recommended values are shown in the table at right. The  
output filtering capacitor C2 is a high frequency, low resistance  
electrolytic capacitor. Capacitor C1 is ceramic. Voltage derating  
of capacitors should be 80% or above.  
MPM-20SV-03  
MPM-20SV-05  
MPM-20SV-09  
MPM-20SV-12  
MPM-20SV-15  
MPM-20SV-24  
1.0 µF/50V  
1.0 µF/50V  
1.0 µF/50V  
1.0 µF/50V  
1.0 µF/50V  
1.0 µF/50V  
330 µF/10V  
330 µF/10V  
220 µF/25V  
220 µF/25V  
220 µF/25V  
220 µF/35V  
SMBJ7.0A  
SMBJ7.0A  
SMBJ12A  
SMBJ20A  
SMBJ20A  
SMBJ30A  
EN 61000-4-4 ( 4 kV) with the additional input components 6. TheTVS is added to protect circuits being powered from damage  
shown in the typical connection diagram shown on page 3. if the module fails.  
4. All units are rated for EN 61000-4-5 ( 1 kV/ 2 kV) with the addi- 7. The trim resistors (R1 & R2) are used to adjust the output voltage  
tion of the MOV shown in the typical connection above. They will  
meet EN 61000-4-5 ( 2 kV / 4 kV) with the input components  
shown in the typical connection diagram on page 3.  
level up or down. If this is not required, the trim pin should be  
left open. See page 4 for details on using the trim function.  
Derating Curve  
Input Voltage Vs Load  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com  
EMI Characteristics  
Parameter  
Radiated Emissions  
Conducted Emissions  
www.micropowerdirect.com  
Notes:  
Conditions  
Criteria  
Level  
Class B  
Class B  
8 kV Air  
6 kV Contact  
10V/m  
1. To meet the requirements of EN 61000-  
4-4 ( 4 kV), external components are  
needed. This can be done discretely (as  
shown below), or with the addition of the  
MACFM-02A.Contact the factory for more  
information.  
EN 55022  
EN 55022  
ESD  
RS  
EN 61000-4-2  
EN 61000-4-3  
B
A
B
B
B
B
A
A
B
2. To meet the requirements of EN 61000-4-5  
( 2 kV/ 4 kV ), external components are  
needed. This can be done discretely (as  
shown below), or with the addition of the  
MACFM-02A. Contact the factory for more  
information.  
2 kV  
4 kV  
1 kV/ 2 kV  
2 kV/ 4 kV  
10V rms  
10A/m  
EFT  
EN 61000-4-4  
EN 61000-4-5  
See Note 1  
Surge  
See Note 2  
EN 61000-4-6  
EN 61000-4-8  
EN 61000-4-11  
CS  
PFM  
Voltage Dips, Short, Interruptions  
0% - 70%  
Typical Connection: With Input Protection/Filtering Components  
The diagram above illustrates a typical connection of the MPM-20SV series. 5. Suggested component values are:  
The input components are required to meet the more stringent EFT/Surge levels  
of EN 61000-4 (see notes for EMC Characteristics table above). Some notes on  
these components are:  
Component  
Fuse  
MPM20SV-03 MPM20SV-05 MPM20SV-09 MPM20SV-12 MPM20SV-15 MPM20SV-24  
3.15A/300 VAC 3.15A/300 VAC 3.15A/300 VAC 3.15A/300 VAC 3.15A/300 VAC 3.15A/300 VAC  
MOV  
CX  
LDM  
LCM  
S14K350  
0.1 µF/310V  
4.7 µH/2A  
10 mH  
S14K350  
0.1 µF/310V  
4.7 µH/2A  
10 mH  
S14K350  
0.1 µF/310V  
4.7 µH/2A  
10 mH  
S14K350  
0.1 µF/310V  
4.7 µH/2A  
10 mH  
S14K350  
0.1 µF/310V  
4.7 µH/2A  
10 mH  
S14K350  
0.1 µF/310V  
4.7 µH/2A  
10 mH  
1. It is recommended that an external fuse be used. The recommended fuse  
size is a 3.15A/300 VAC slow blow.  
2. An external MOV is recommended on the input to protect the unit in the event  
of a surge. A recommended value is given in the table at right.  
3. The output filtering capacitors (C1 & C2) will reduce the output noise below  
specified levels. Recommended values are given in the table on page 2.  
4. TheTVS is added to protect circuits being powered from damage if the module  
fails. A recommended value for each model is given in the table on page 2.  
1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC  
CY1/CY2  
6. Input protection and filtering modules are available for a number of MPDAC/DC power supplies. For use with the MPM-20SV product series,  
the MACFM-02A filter module is recommended. A typical connection diagram and board layout with this module is shown in the figures  
below. For pricing or full technical information on the MACFM-02A (or any of our other modules) please contact the factory.  
Typical Board Layout: With External Filter Module  
Typical Board Layout: With External Filter Module  
1. The width of circuit traces should be a minimum of 3 mm.  
2. The distance between traces should be a minimum of 6 mm.  
3. The distance between a trace and ground should be a minimum of 6 mm.  
MicroPower Direct  
292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com  
External Trim  
If not used, the Trim pin should be left open. Please contact the factory for more information.  
www.micropowerdirect.com  
External Trim Notes:  
An external resistor can be used to adjust the converter  
output up or down by about 10%. The connection is shown  
in the diagram at left. The required resistor value is  
calculated by the formulas:  
A $ R2  
V
REF  
=
=
=
-
Trim UP RTRIM  
R3 Where A  
$R1  
REF  
-
-
V
R2  
A
VTRIM  
-
VTRIM V  
REF  
A $ R1  
REF  
=
=
=
-
Trim Down RTRIM  
R3 Where A  
$R2  
-
R1  
A
V
Where:  
RTRIM = The value of the external trim  
resistor  
VTRIM = The amount of voltage  
adjustment required  
The values for R1, R2, R3 and VREF are given in  
the table below.  
Output Voltage (VDC)  
3.3  
5.0  
9.0  
12  
15  
24  
R1  
R2  
3.30 k  
1.98 k⍀  
1.00 k⍀  
1.24 V  
3.30 k⍀  
3.30 k⍀  
1.00 k⍀  
2.50 V  
7.50 k⍀  
2.87 k⍀  
1.00 k⍀  
2.50 V  
3.83 k⍀  
1.00 k⍀  
1.00 k⍀  
2.50 V  
7.50 k⍀  
1.50 k⍀  
1.00 k⍀  
2.50 V  
8.66 k⍀  
1.00 k⍀  
1.00 k⍀  
2.50 V  
R3  
VREF  
Mechanical Dimensions  
Pin Connections  
Pin  
Function  
AC-Ground  
AC-Neutral  
AC-Line  
1
2
3
4
-VOUT  
8
+VOUT  
Trim  
VOUT Trim  
Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.02 ( 0.50)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MPM-24M

24W Output Power
MPD

MPM-24MD-12xx

24W Output Power
MPD

MPM-24MD-15xx

24W Output Power
MPD

MPM-24MS-05xx

24W Output Power
MPD

MPM-24MS-09xx

24W Output Power
MPD

MPM-24MS-12xx

24W Output Power
MPD

MPM-24MS-15xx

24W Output Power
MPD

MPM-24MS-24xx

24W Output Power
MPD

MPM-25S

Universal Input, 25W Miniature, PC Mount AC/DC Power Supplies
MPD

MPM-25S-05

Universal Input, 25W Miniature, PC Mount AC/DC Power Supplies
MPD

MPM-25S-12

Universal Input, 25W Miniature, PC Mount AC/DC Power Supplies
MPD

MPM-25S-15

Universal Input, 25W Miniature, PC Mount AC/DC Power Supplies
MPD