MPM-30T-0515IS [MPD]
Board Mount, 30W Single, Dual & Triple Out AC/DC Power Supplies; 板机接口, 30W单,双和三输出AC / DC电源型号: | MPM-30T-0515IS |
厂家: | MICROPOWER DIRECT, LLC |
描述: | Board Mount, 30W Single, Dual & Triple Out AC/DC Power Supplies |
文件: | 总2页 (文件大小:245K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MPM-30IS Series
Single, Dual & Triple Out
AC/DC Power Supplies
Electrical Specifications
Key Features:
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 30W Output Power
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
• Universal 85-265 VAC Input
• EN 60950 Approved
• Meets IEC Safety Class II
• Industry Standard Pin-Out
• Single, Dual & Triple Outputs
• Meets EN55022 B
Conditions
Min.
85
47
Typ.
Max.
265
440
Units
VAC
Hz
See Model Selection Guide
115 VAC
230 VAC
20.0
40.0
Inrush Current
A Pk
EMI
Meets CISPR Pub. 22/FCC Class B
• >250 kHour MTBF
115 VAC
230 VAC
0.1
0.3
Safety Ground Leakage Current
mA
Chassis Mount Models
& DIN Rail Mount
Option Available!
Output
Parameter
Output Voltage
Output Current
Conditions
Min.
Typ.
Max.
Units
See Model Selection Guide
See Model Selection Guide
Output Voltage Accuracy, Note 1
Line Regulation
Load Regulation, Single Output
Load Regulation, Dual Output
Load Regulation, Triple Output - Primary
Load Regulation, Triple Output - Aux.
1.0
2.0
1.0
1.0
5.0
5.0
%
%
%
%
%
%
VIN = Min to Max
IO = Min to Max
IO = Min to Max
IO = Min to Max
IO = Min to Max
3.3 & 5.0 VDC Output
All Other Outputs
115 VAC, 60 Hz
0.2
0.5
2.5
2.5
4.0
1.5
1.0
20
1.8
1.3
Ripple & Noise (20 MHz)
%VP-P of VO
Hold-Up Time
mSec
%/°C
% of VO
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, Note 4
Overload Protection, Note 5
General
0.02
120
Zener Diode Clamp
Continuous (Autorecovery)
Typ. 120% to 180% of Output Power
Parameter
Conditions
Input to Output 3,000
Input to Output, Flash Tested For 60S 4,700
Min.
Typ.
Max.
Units
VAC
VAC
MΩ
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
EMI/RFI
500 VDC
Conducted
100
EN 55022 Level B
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
IEC/EN 61000-4-2 Level B
IEC/EN61000-4-3
IEC/EN 61000-4-4 Level 3 2 kV
MicroPower Direct
292 Page Street
Suite D
EMC Compliance
Surge IEC/EN 61000-4-5 Level 3 1kV/2 kV
Stoughton, MA 02072
USA
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
100
kHz
Conditions
Min.
-25
-40
Typ.
+25
Max.
+71
+85
Units
°C
°C
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Ambient
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
Humidity
%
Physical
Case Size
3.50 x 2.50 x 0.85 Inches (88.9 x 63.5 x 21.5 mm)
Non-Conductive Plastic& Fiberglass (UL94-V0)
6.23 Oz (177g)
Case Material
Weight
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
250
kHours
Safety Standards
Safety Approvals
Safety Class
IEN 60950, IEC 60950
IEN 60950, IEC 60950
IEC 61140 Class II
Model Selection Guide
Input
Output 1 (Vout 1)
Current (A)
Output 2 (Vout 2)
Current (A)
Output 3 (Vout 3)
Current (A)
Capacitive
Load
(µF, Max)
Model
Current (A)
Efficiency
(%, Typ)
Voltage
Voltage
Voltage
Number
(VDC)
(VDC)
(VDC)
115 VAC 230 VAC
Max.
Min.
Max.
Min.
Max.
Min.
MPM-30S-05IS
MPM-30S-12IS
MPM-30S-15IS
MPM-30S-24IS
MPM-30S-48IS
MPM-30D-12IS
MPM-30D-15IS
MPM-30T-0512IS
MPM-30T-0512ISA
MPM-30T-0515IS
MPM-30T-5312IS
MPM-30T-3512IS
0.557
0.543
0.543
0.543
0.543
0.565
0.543
0.572
0.572
0.572
0.588
0.483
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
5.0
6.000
2.500
2.000
1.250
0.625
0.600
0.250
0.200
0.125
0.063
8,000
3,900
3,900
1,500
1,000
1,500
1,500
78
80
80
80
80
80
80
76
76
76
71
71
12.0
15.0
24.0
48.0
+12.0 +1.300 +0.130
+15.0 +1.000 +0.100
-12.0 -1.300 -0.130
-15.0 -1.000 -0.100
+12.0 +0.600 +0.120
+12.0 +1.000 +0.200
+15.0 +0.500 +0.050
+3.3 +1.000 +0.220
+5.0 +1.500 +0.300
5.0
5.0
5.0
5.0
3.3
3.000 +0.600
3.000 +0.600
3.000 +0.300
4.500 +0.900
4.000 +0.800
-12.0 -0.600 -0.120 See Note 6
-12.0 -0.250 -0.050 See Note 6
-15.0 -0.500 -0.050 See Note 6
+12.0 +0.250 +0.050 See Note 6
+12.0 +0.250 +0.050 See Note 6
Derating Curve
Other output combinations are available
Contact the factory for details at:
sales@micropowerdirect.com
Notes:
1. For triple output models, the output voltage accuracy of the
auxilliary outputs is typically 4%.
2. Load regulation is measured for an output change of 0% to
100% at nominal input line. For multiple output models, the
loads are balanced.
3. Operation at no-load will not damage these units. However,
they may not meet all specifications.
4. Output short circuit protection is provided by a “hiccup mode”
circuit. The unit recovers automatically when the fault condition
is removed.
5. Output overload protection is provided by a fold back current
limiting circuit.
6. For triple output models, the maximum capacitive load for 5
VDC and 3.3VDC outputs is 2,200 µF. For all other outputs it is
1,500 µF.
7. The MPM-30IS series includes a built-in 3.5A/250 VAC fuse. It
is recommended that an external 1.5A slow blow fuse also be
used on the input for protection.
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
Triple
1
2
3
4
5
6
7
AC-Neutral
AC-Line
+Vo
NP
Common
NP
+Vo
NP
-Vo
NP
+Vo 2
+Vo 1
Common 2/3
-Vo 1
NP
-Vo
+Vo 3
NC = No Connection
Notes:
All dimensions are typical in inches (mm)
MicroPower Direct Tolerance x.xx = 0.01 ( 0.25)
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
©2020 ICPDF网 联系我们和版权申明