MPM07S03PB [MPD]

MPM-07PB Series;
MPM07S03PB
型号: MPM07S03PB
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

MPM-07PB Series

文件: 总2页 (文件大小:258K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series  
MPM-07PB  
Compact 1 x 2 Inch  
7W, Single Output  
AC/DC Power Supplies  
Electrical Specifications  
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Key Features:  
Input  
7W Output Power  
Parameter  
Conditions  
Min.  
85  
120  
47  
Typ.  
Max.  
264  
370  
440  
Units  
VAC  
VDC  
Hz  
Compact 1 x 2 Inch Case  
Universal 85-264 VAC Input  
EN 60950 Approved (UL)  
ErP Directive Compliant  
Meets EN 55022 B  
Input Voltage Range  
Input Frequency  
Input Current  
See Model Selection Guide  
115 VAC  
10.0  
20.0  
0.3  
Inrush Current  
A Pk  
W
230 VAC  
No Load Power Consumption  
Output  
Parameter  
Meets IEC Safety Class II  
Conditions  
Min.  
Typ.  
Max.  
Units  
>330 kHour MTBF  
Output Voltage  
Output Current  
See Model Selection Guide  
See Model Selection Guide  
Output Voltage Accuracy  
Line Regulation  
Load Regulation  
1.0  
2.0  
1.0  
1.0  
1.8  
1.0  
%
%
%
VIN = Min to Max  
IOUT = 0% to 100%  
3.3V and 5V Models  
12V, 15V, and 24V Models  
115 VAC  
0.5  
0.5  
1.5  
0.8  
20  
Ripple & Noise (20 MHz), See Note 1  
% V P-P of VOUT  
Hold-Up Time  
230 VAC  
60  
mSec  
%/°C  
%VOUT  
°C  
Temperature Coefficient  
Over Voltage Protection  
Over Temperature Protection  
Short Circuit Protection  
Overload Protection  
General  
0.01  
120  
90  
0.02  
Zener Diode Clamp  
Autorecovery (at 67 °C)  
Continuous (Autorecovery)  
Foldback, Autorecovery 105  
%W  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
VAC  
M  
Isolation Voltage  
Isolation Resistance  
Switching Frequency  
EMI Characteristics  
Parameter  
Radiated Emissions  
Conducted Emissions  
ESD  
Input to Output 3,000  
500 VDC  
100  
100  
kHz  
Standard  
Min.  
Typ.  
Max.  
Class B  
Class B  
Units  
EN 55022  
EN 55022  
EN 61000-4-2 Criteria B; 8 kV Air/ 4 kV Contact  
RS  
EFT  
Surge  
CS  
PFM  
Voltage Dips  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
EN 61000-4-8  
EN 61000-4-11  
Criteria A; 10V/m  
Criteria B; 2 kV  
Criteria B; 1 kV  
Criteria B; 10 Vrms  
Criteria A; 30A/m  
Criteria B; 10 mS  
Environmental  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Parameter  
Conditions  
Min.  
-25  
-40  
Typ.  
+25  
Max.  
+70  
+85  
Units  
°C  
°C  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Ambient  
Free Air Convection (See Derating Curve)  
RH, Non-condensing 95  
Humidity  
%
Physical  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Case Size  
2.00 x 1.00 x 0.76 Inches (50.8 x 25.4 x 19.3 mm)  
Non-Conductive Black Plastic (UL94-V0)  
1.55 Oz (44g)  
Case Material  
Weight  
Reliability Specifications  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
MTBF  
MIL HDBK 217F, 25°C, Gnd Benign  
300  
kHours  
Safety Standards  
Safety Class  
ECO Design  
EN 60950  
IEC 60536 Class II  
ErP Directive 2009/125/EC  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output 1 (Vout 1)  
Current (A)  
Fuse  
Capacitive  
Rating  
Model  
Number  
Current (A)  
Efficiency  
(%, Typ)  
Load  
Voltage  
Slow-Blow  
(µF Max)  
(mA)  
(VDC)  
115 VAC 230 VAC  
Max.  
Min.  
MPM-07S-03PB  
MPM-07S-05PB  
MPM-07S-12PB  
MPM-07S-15PB  
MPM-07S-24PB  
0.96  
0.139  
0.130  
0.130  
0.130  
0.051  
0.051  
0.051  
0.051  
0.051  
3.3  
5.0  
1.400  
1.400  
0.583  
0.466  
0.291  
0.140  
0.140  
0.058  
0.047  
0.029  
70  
73  
78  
78  
78  
2,200  
2,200  
1,000  
1,000  
680  
1,500  
1,500  
1,500  
1,500  
1,500  
12.0  
15.0  
24.0  
Derating Curve  
Other outputs may be available  
Contact the factory for details at:  
sales@micropowerdirect.com  
Notes:  
1. Load regulation is measured for an output change of 0% to 100% at  
nominal input line.  
2. Operation at no-load will not damage these units. However, they may  
not meet all specifications.  
3. Output short circuit protection is provided by a “hiccup mode” circuit.  
The unit recovers automatically when the fault condition is removed.  
4. Output overload protection is provided by a fold back current limit-  
ing circuit.  
5. It is recommended that an external slow blow fuse also be used on  
the input for protection. See the table above for the correct rating.  
Mechanical Dimensions  
Pin Connections  
Pin  
Function  
1
2
3
4
AC-Neutral  
AC-Line  
+Vout  
-Vout  
Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.01 ( 0.25)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MPM07S05PB

MPM-07PB Series
MPD

MPM07S12PB

MPM-07PB Series
MPD

MPM07S15PB

MPM-07PB Series
MPD

MPM07S24PB

MPM-07PB Series
MPD

MPM08D0503MB

MPM-08MB Series
MPD

MPM08D1205MB

MPM-08MB Series
MPD

MPM08S03MB

MPM-08MB Series
MPD

MPM08S05MB

MPM-08MB Series
MPD

MPM08S09MB

MPM-08MB Series
MPD

MPM08S12MB

MPM-08MB Series
MPD

MPM08S15MB

MPM-08MB Series
MPD

MPM08S24MB

MPM-08MB Series
MPD