MPO-25S-24 [MPD]
Single Output, 25W Compact, Open Frame AC/DC Power Supplies; 单路输出, 25W紧凑型,开放式AC / DC电源型号: | MPO-25S-24 |
厂家: | MICROPOWER DIRECT, LLC |
描述: | Single Output, 25W Compact, Open Frame AC/DC Power Supplies |
文件: | 总2页 (文件大小:222K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MPO-25S Series
Single Output, 25W
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 25W Output Power
• Universal 90-264 AC Input
• EN 60950 Compliant
• Low Leakage Current
• Nine Single Output Models
• Meets EN55022
Parameter
Conditions
Min.
90
127
47
Typ.
Max.
264
370
63
Units
VAC
VDC
Hz
Universal
Input Voltage Range
Input Frequency
Input Current
See Model Selection Guide
Cold Start, 115 VAC
Cold Start, 230 VAC
20.0
36.0
0.35
0.5
Inrush Current
A Pk
mA
115 VAC
240 VAC
Safety Ground Leakage Current
• >500 kHour MTBF
Output
Parameter
• Only 4.2” x 2.4” x 1.1”
Conditions
Min.
Typ.
Max.
Units
Output Voltage
Output Current
Output Voltage Adjustment
Output Voltage Tolerance, See Note 1
Ripple & Noise (20 MHz), See Note 2
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
115 VAC
230 VAC
115/230 VAC
115 VAC
20
100
200
30
20
0.02
Hold-Up Time
Set-Up Time
Rise Time
mSec
mSec
mSec
%/°C
230 VAC
RoHS Compliant Temperature Coefficient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Continuous (Autorecovery)
See Note 3 115
See Note 4 105
See Note 5
135
%
%
Over Temperature
U1 >135 °C
General
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC
MΩ
Input to Output 3,000
Input to Ground 1,500
Output to Ground
500 VDC
Isolation Voltage
500
Isolation resistance
EMI/RFI
100
Conducted
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN61000-4-3
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
MicroPower Direct
292 Page Street
Suite D
EMC Compliance
IEC/EN 61000-4-4
IEC/EN 61000-4-5
Stoughton, MA 02072
USA
Switching Frequency
Fixed
100
kHz
Environmental
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Parameter
Conditions
Min.
-10
-20
Typ.
+25
Max.
+60
+85
Units
°C
°C
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Ambient
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
%
Physical
Size
4.2 x 2.4 x 1.1 Inches (107.0 x 67.0 x 28.0 mm)
4.9 Oz (0.14 kg)
Weight
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
300
Typ.
Max.
Units
kHours
Safety Standards
Vibration
IEN 60950, IEC 60950
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
Model Selection Guide
Input
Output
Output
Tolerance
(%)
Ripple &
Noise
(mV p-p)
Model
Number
Efficiency
(%, Typ)
Current (A)
Voltage (VDC)
Rated Adjust
Current (A)
115 VAC 230 VAC
Rated
Range
MPO-25S-3.3
MPO-25S-05
MPO-25S-7.5
MPO-25S-12
MPO-25S-13.5
MPO-25S-15
MPO-25S-24
MPO-25S-27
MPO-25S-48
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
3.3
5.0
7.5
12.0
13.5
15.0
24.0
27.0
48.0
3.14 - 3.63
4.75 - 5.5
5.0
5.0
3.3
2.1
1.9
1.7
1.0
0.9
0.5
0 to 5.0
0 to 5.0
0 to 3.3
0 to 2.1
0 to 1.9
0 to 1.7
0 to 1.0
0 to 0.9
0 to 0.5
3.0
3.0
3.0
2.0
2.0
2.0
2.0
2.0
2.0
80
80
80
100
100
100
240
240
350
66
74
76
78
78
78
79
79
79
7.13 - 8.25
11.4 - 13.2
12.8 - 14.9
14.25 - 16.5
22.8 - 26.4
25.65 - 29.7
45.6 - 52.8
Notes:
Mechanical Dimensions
1. Output voltage tolerance includes the the effects of set point
accuracy, line regulation and load regulation.
2. Ripple and noise is measured at 20 MHz bandwidth using
a 12 inch twisted pair wire to connect to the power supply
terminals. A 0.1 µF and a 47 µF capacitor are connected in
parallel as close to the power supply terminals as possible.
3. The overvoltage protection circuit shuts down the output.
The unit must be repowered to recover.
4. Overload protection is provided by a “hiccup mode” circuit.
The unit recovers automatically when the fault condition is
removed.
5. The over temperature protection circuit shuts down the out-
put. The unit recovers automatically when the fault condition
is removed.
6. Mounting holes M1 and M2 should be grounded for EMI
purposes.
7. It is recommended that a fuse be used on the input of a power
supply for protection. See the mechanical diagram for the
correct rating.
Pin Connections: CN1 (Molex 41791-03 or equiv.)
Mating
Pin Function
Terminal
Housing
Molex 2139 Molex 2478
or Equiv. or Equiv.
1
3
AC-Line
AC-Neutral
Pin Connections: CN2 (Molex 41791-04 or equiv.)
Mating
Pin
Function
Terminal
Housing
Molex 2139 Molex 2478
or Equiv. or Equiv.
1, 2
3, 4
+Vout
-Vout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.25)
Static Characteristics: 24V
Derating Curve
MicroPower Direct
•
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号: