MPO-45S-24 [MPD]
Single Output, 45W Compact, Open Frame AC/DC Power Supplies; 单路输出, 45W紧凑型,开放式AC / DC电源型号: | MPO-45S-24 |
厂家: | MICROPOWER DIRECT, LLC |
描述: | Single Output, 45W Compact, Open Frame AC/DC Power Supplies |
文件: | 总2页 (文件大小:311K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MPO-45S Series
Single Output, 45W
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 45W Output Power
• Universal 90-264 AC Input
• EN 60950 Compliant
• Low Leakage Current
• Nine Single Output Models
• Meets EN55022
Parameter
Conditions
Min.
90
127
47
Typ.
Max.
264
370
63
Units
VAC
VDC
Hz
Universal
Input Voltage Range
Input Frequency
Input Current
See Model Selection Guide
Cold Start, 115 VAC
Cold Start, 230 VAC
15.0
30.0
0.5
Inrush Current
A Pk
mA
115 VAC
240 VAC
Safety Ground Leakage Current
• >300 kHour MTBF
• Only 5” x 3” x 1.1”
0.75
Output
Parameter
Conditions
Min.
Typ.
Max.
Units
Output Voltage
Output Current
Output Voltage Adjustment
Output Voltage Tolerance, See Note 1
Ripple & Noise (20 MHz), See Note 2
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
115 VAC
230 VAC
230 VAC
230 VAC
15
60
800
30
Hold-Up Time
mSec
Set-Up Time
Rise Time
mSec
mSec
%/°C
Temperature Coefficient
Short Circuit Protection
Over Voltage Protection
Overload Protection
General
0.02
RoHS Compliant
Continuous (Autorecovery)
See Note 3 115
135
166
%
%
See Note 4 118
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC
MΩ
Input to Output 3,000
Input to Ground 1,500
Output to Ground
500 VDC
Isolation Voltage
500
Isolation resistance
EMI/RFI
100
Conducted
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN61000-4-3
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
MicroPower Direct
292 Page Street
Suite D
EMC Compliance
IEC/EN 61000-4-4
IEC/EN 61000-4-5
Stoughton, MA 02072
USA
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Fixed
65
kHz
Conditions
Min.
-10
-20
Typ.
+25
Max.
+60
+85
Units
°C
°C
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Ambient
Free Air Convection (See Derating Curve)
RH, Non-condensing 95
Humidity
%
Physical
Size
Weight
5.00 x 3.00 x 1.10 Inches (127.0 x 76.2 x 28.0 mm)
6.7 Oz (0.19 kg)
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
300
kHours
Safety Standards
Vibration
IEN 60950, IEC 60950
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
Model Selection Guide
Input
Output
Output
Tolerance
(%)
Ripple &
Noise
(mV p-p)
Model
Number
Efficiency
(%, Typ)
Current (A)
Voltage (VDC)
Rated Adjust
Current (A)
115 VAC 230 VAC
Rated
Range
MPO-45S-3.3
MPO-45S-05
MPO-45S-7.5
MPO-45S-12
MPO-45S-13.5
MPO-45S-15
MPO-45S-24
MPO-45S-27
MPO-45S-48
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.56
0.56
0.56
0.56
0.56
0.56
0.56
0.56
0.56
3.3
5.0
7.5
12.0
13.5
15.0
24.0
27.0
48.0
3.14 - 3.63
4.75 - 5.5
8.0
8.0
5.4
3.7
3.3
3.0
1.9
1.7
1.0
0 to 10.7
0 to 10.5
0 to 7.0
0 to 4.4
0 to 3.9
0 to 3.5
0 to 2.2
0 to 1.95
0 to 1.1
3.0
3.0
3.0
2.0
2.0
2.0
2.0
2.0
2.0
80
100
100
100
100
100
100
100
100
69
74
75
76
77
77
78
78
78
7.13 - 8.25
11.4 - 13.2
12.8 - 14.85
14.25 - 16.5
22.8 - 26.4
25.65 - 29.7
45.6 - 52.8
Notes:
Mechanical Dimensions
1. Output voltage tolerance includes the the effects of set point
accuracy, line regulation and load regulation.
2. Ripple and noise is measured at 20 MHz bandwidth using
a 12 inch twisted pair wire to connect to the power supply
terminals. A 0.1 µF and a 47 µF capacitor are connected in
parallel as close to the power supply terminals as possible.
3. Overvoltage protection is provided by a “hiccup mode” circuit.
The unit recovers automatically when the fault condition is
removed.
4. Overload protection is provided by a foldback current limit-
ing circuit. The unit recovers automatically when the fault
condition is removed. For the 3.3V output model, overload
protection is set to operate between 36 to 55W.
5. Mounting holes M1 and M2 should be grounded for EMI
purposes.
6. It is recommended that a fuse be used on the input of a power
supply for protection. See the mechanical diagram for the
correct rating.
Pin Connections: CN1 (Molex 5277-02 or equiv.)
Mating
Pin Function
Terminal
Housing
Molex 5195 Molex 5194
or Equiv. or Equiv.
1
2
AC-Neutral
AC-Line
Pin Connections: CN2 (Molex 5273-06 or equiv.)
Mating
Pin
Function
Terminal
Housing
Molex 5195 Molex 5194
or Equiv. or Equiv.
1, 2, 3
4, 5, 6
+Vout
-Vout
Notes:
Derating Curve
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.25)
Static Characteristics
MicroPower Direct
•
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com