MPO40S05 [MPD]

MPO-40S Series;
MPO40S05
型号: MPO40S05
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

MPO-40S Series

文件: 总2页 (文件大小:346K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series  
MPO-40S  
Single Output, 40W  
Compact, Open Frame  
AC/DC Power Supplies  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Key Features:  
Input  
40W Output Power  
Universal 90-264 AC Input  
EN 60950 Approved (UL)  
Compact 2 x 4 In Package  
Nine Standard Models  
Meets EN 55022 B  
Parameter  
Conditions  
Min.  
90  
127  
47  
Typ.  
Max.  
264  
373  
63  
Units  
VAC  
VDC  
Hz  
Universal  
Input Voltage Range  
Input Frequency  
Input Filter  
Input Current  
Meets EN 55022 Class B; FCC Class B  
See Model Selection Guide  
Cold Start, 115 VAC  
Cold Start, 230 VAC  
264 VAC  
32.0  
50.0  
3.5  
Inrush Current  
A Pk  
mA  
Meets EN 61000-4  
Safety Ground Leakage Current  
Output  
>200 kHour MTBF  
Parameter  
Conditions  
See Model Selection Guide  
See Note 1 1.0  
Min.  
Typ.  
Max.  
Units  
Output Voltage/Current  
Output Voltage Tolerance  
Line Regulation  
Load Regulation  
Ripple & Noise (20 MHz)  
%
%
%
%
Vin = 100 VAC to 240 VAC  
Iout = 10% to 100%  
See Note 2  
0.5  
1.0  
1.0  
8
115 VAC  
Hold-Up Time  
mSec  
%/°C  
230 VAC  
100  
0.05  
Temperature Coefficient  
Short Circuit Protection  
Overload Protection  
General  
Continuous (Autorecovery)  
See Note 3  
150  
%
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
VAC  
M  
pF  
Isolation Voltage  
Isolation Resistance  
Isolation Capacitance  
EMI/RFI  
Input to Output 3,000  
500 VDC  
1,000  
4,700  
Conducted  
EN 55022; EN 61000-3-2, -3  
IEC/EN 61000-4-2, -6, -8, -11  
IEC/EN 61000-4-3  
Electrostatic Discharge (ESD)  
RF Field Susceptibility  
Electrical Fast Transients/Bursts On Mains  
EMC Compliance  
IEC/EN 61000-4-4  
Surge  
Fixed  
IEC/EN 61000-4-5  
Switching Frequency  
Environmental  
Parameter  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
66  
kHz  
Conditions  
Min.  
0
-20  
Typ.  
+25  
Max.  
+50  
Units  
°C  
MicroPower Direct  
292 Page Street  
Suite D  
Ambient  
+85  
°C  
Free Air Convection (See Derating Curve)  
RH, Non-condensing 93  
Stoughton, MA 02072  
USA  
Humidity  
%
Physical  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Size  
Weight  
4.00 x 2.00 x 1.20 Inches (101.60 x 50.08 x 30.48 mm)  
5.99 Oz (0.170 kg)  
Reliability Specifications  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Units  
MTBF  
MIL HDBK 217F, 25°C, Gnd Benign  
200  
kHours  
Safety Standards  
Vibration  
UL 60950, EN 60950  
Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Input  
Output  
Current (A)  
Max  
Output  
Max  
Model  
Number  
Output  
Power Capacitance  
Efficiency  
(%, Typ)  
Current (A)  
Voltage  
(VDC)  
115 VAC 230 VAC  
Rated  
% Min.  
(W)  
(µF)  
MPO-40S-03  
MPO-40S-036  
MPO-40S-05  
MPO-40S-09  
MPO-40S-12  
MPO-40S-138  
MPO-40S-15  
MPO-40S-24  
MPO-40S-48  
0.75  
0.75  
0.75  
0.75  
0.75  
0.75  
0.75  
0.75  
0.75  
0.45  
0.45  
0.45  
0.45  
0.45  
0.45  
0.45  
0.45  
0.45  
3.3  
3.6  
5.0  
6.00  
6.00  
6.00  
4.45  
3.34  
2.90  
2.67  
1.67  
0.83  
0.00  
0.00  
0.00  
0.00  
0.00  
0.00  
0.00  
0.00  
0.00  
20  
6,000  
6,000  
6,000  
4,450  
3,700  
1,980  
1,980  
1,710  
850  
70  
70  
76  
84  
85  
83  
85  
86  
87  
21.6  
30  
40  
40  
40  
40  
40  
40  
9.0  
12.0  
13.8  
15.0  
24.0  
48.8  
Derating Curve  
Other Models Are Available. Contact The Factory For Details  
Notes:  
1. Output voltage tolerance is measured at nominal input and 60% load.  
2. Output ripple is measured at 20 MHz bandwidth using 0.1 µF and 10 µF  
capacitors connected in parallel as close to the power supply terminals  
as possible.  
3. These units will operate at no load without damage. For most appli-  
cations however, MPD recommends that a minimum load always be  
used. Contact the factory for more information.  
4. Each unit includes an input fuse (250V/2A). Since this fuse is not field  
replaceable, it is recommended that an external fuse of the same size  
be used on the input of the power supply for protection.  
Mechanical Dimensions  
Connections  
Input Connector (CN1):  
Molex 5273-03A or equivalent (one pin removed)  
Mating Housing: Molex 5195-03 or equivalent  
Mating Terminal: Molex 5293 or equivalent  
Pin  
1
2
Function  
AC-Neutral  
Removed  
AC-Line  
3
Safety Ground:  
The mounting holes marked “Use metal standoffs” should be  
connected to the system earth ground via metal spacers or  
a cable. The input side mounting hole marked “FG” provides  
the safety earth ground for the unit. This connection should  
be locked to prevent possible loosening. Connecting the  
output side mounting hole improves EMI.  
Output Connector (CN2):  
Molex 5273-04A or equivalent  
Mating Housing: Molex 5195-04 or equivalent  
Mating Terminal: Molex 5293 or equivalent  
Pin  
1
Function  
+VOUT  
2
+VOUT  
3
-VOUT  
4
-VOUT  
Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.02 ( 0.50)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MPO40S09

MPO-40S Series
MPD

MPO40S12

MPO-40S Series
MPD

MPO40S138

MPO-40S Series
MPD

MPO40S15

MPO-40S Series
MPD

MPO40S24

MPO-40S Series
MPD

MPO40S48

MPO-40S Series
MPD

MPO40T01

MPO-40T Series
MPD

MPO40T02

MPO-40T Series
MPD

MPO40T03

MPO-40T Series
MPD

MPO40T04

MPO-40T Series
MPD

MPO40T05

MPO-40T Series
MPD

MPO40T06

MPO-40T Series
MPD