MPO40T01 [MPD]
MPO-40T Series;型号: | MPO40T01 |
厂家: | MICROPOWER DIRECT, LLC |
描述: | MPO-40T Series |
文件: | 总2页 (文件大小:387K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series
MPO-40T
Triple Output, 40W
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 40W Output Power
Input
Parameter
Conditions
Min.
90
127
47
Typ.
Max.
264
373
63
Units
VAC
VDC
Hz
Universal
• Triple Outputs
Input Voltage Range
• Universal 90-264 AC Input
• EN 60950 Approved (UL)
• Compact 2 x 4 In Package
• Eight Standard Models
• Meets EN 55022 B
• >200 kHour MTBF
Input Frequency
Input Filter
Input Current
Meets EN 55022 Class B; FCC Class B
See Model Selection Guide
Cold Start, 115 VAC
Cold Start, 230 VAC
264 VAC
29.0
50.0
3.5
Inrush Current
A Pk
mA
Safety Ground Leakage Current
Output
Parameter
Conditions
Min.
Typ.
Max.
Units
Output Voltage/Current
See Model Selection Guide
Output 1, 3
Output 2
Output 1, 3
Output 2
Output 1
Output 2
Output 3
3.0
Output Voltage Tolerance, See Note 1
Line Regulation, See Note 2
%
%
4.0
0.5
2.0
3.0
5.0
1.0
Load Regulation, See Note 3
%
Ripple & Noise (20 MHz), See Note 4
Hold-Up Time
See Model Selection Guide
115 VAC
230 VAC
8
20
mSec
%/°C
Temperature Coefficient
Short Circuit Protection
Over Voltage Protection
Overload Protection
General
0.05
Continuous (Autorecovery)
130
%
%
See Note 3
150
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC
M⍀
pF
Isolation Voltage
Isolation Resistance
Isolation Capacitance
EMI/RFI
Input to Output 3,000
500 VDC
1,000
2,200
Conducted
Electrostatic Discharge (ESD)
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN 61000-4-3
RF Field Susceptibility
EMC Compliance
Electrical Fast Transients/Bursts On Mains
IEC/EN 61000-4-4
Surge
Fixed
IEC/EN 61000-4-5
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
66
kHz
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conditions
Min.
0
-20
Typ.
+25
Max.
+45
Units
°C
Ambient
+85
°C
Free Air Convection (See Derating Curve)
RH, Non-condensing 93
Humidity
%
Physical
Size
Weight
Reliability Specifications
Parameter
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
4.00 x 2.00 x 1.20 Inches (101.60 x 50.08 x 30.48 mm)
5.99 Oz (0.170 kg)
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
200
kHours
Safety Standards
Vibration
UL 60950, EN 60950
Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Notes:
Input
Current (A)
Output
Current (A)
Max
Output
Ripple
Max
1. Output voltage tolerance is measured
at nominal input and 60% load.
2. Line regulation is measured at nom-
inal load over a range of 100 to 240
VAC.
Model
Number
Output
Output Efficiency
Voltage
(VDC)
Power & Noise
Cap.
(%, Typ)
No.
115 VAC 230 VAC
Rated
Min.
Max.
(W)
(mV P-P)
(µF)
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
+5.0
+12.0
-5.0
3.0
2.0
0.3
3.0
2.0
0.3
3.0
1.5
0.3
3.0
1.0
0.3
3.0
1.0
0.3
3.0
1.0
0.3
5.0
2.0
0.3
0.4
0.2
0.0
0.4
0.2
0.0
0.4
0.2
0.0
0.4
0.2
0.0
0.4
0.2
0.0
0.4
0.2
0.0
0.4
0.2
0.0
5.0
2.5
0.5
5.0
2.5
0.5
5.0
2.3
0.5
5.0
1.0
0.5
5.0
1.5
0.5
5.0
1.5
0.5
7.0
3.5
0.5
MPO-40T-01
MPO-40T-02
MPO-40T-03
MPO-40T-04
MPO-40T-05
MPO-40T-06
MPO-40T-07
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.46
0.46
0.46
0.46
0.45
0.47
0.38
40
1%
1,400
1,400
1,400
1,400
1,400
1,400
1,400
78
3. Load regulation is specified for a load
change of 60% 40% (of full load).
4. Output ripple is measured at 20 MHz
bandwidth using 0.1 µF and 10 µF
capacitors connected in parallel as
close to the power supply terminals
as possible.
5. The maximum output current is given
for each individual output. The maxi-
mum output power rating for the unit
should not be exceeded. By adding 30
CFM of airflow (see derating curves)
all models may be used at higher
power levels. Contact the factory for
more information.
6. Each unit includes an input fuse
(250V/2A). Since this fuse is not field
replaceable, it is recommended that
an external fuse of the same size be
used on the input of the power supply
for protection.
+5.0
+12.0
-12.0
+5.0
+15.0
-15.0
+5.0
+24.0
-12.0
+5.0
+24.0
-5.0
40
40
40
40
40
30
1%
1%
1%
1%
1%
78
78
78
78
+5.0
+24.0
+12.0
+3.3
+5.0
-12.0
78
3%
2%
1%
71
Derating Curve (Models 01 thru 06)
Derating Curve (Model 07)
Mechanical Dimensions
Connections
Input Connector (CN1):
• Molex 5273-03A or equivalent (one pin removed)
• Mating Housing: Molex 5195-03 or equivalent
• Mating Terminal: Molex 5293 or equivalent
Pin
1
2
Function
AC-Neutral
Removed
AC-Line
3
Safety Ground:
The mounting holes marked “Use metal standoffs” should be
connected to the system earth ground via metal spacers or
a cable. The input side mounting hole marked “FG” provides
the safety earth ground for the unit. This connection should
be locked to prevent possible loosening. Connecting the
output side mounting hole improves EMI.
Output Connector (CN2):
• Molex 5273-06A or equivalent
• Mating Housing: Molex 5195-06 or equivalent
• Mating Terminal: Molex 5293 or equivalent
Pin
1
Function
VOUT 2
2
VOUT 1
3
VOUT 1
4
5
6
Common
Common
VOUT 3
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.02 ( 0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号: