MPU-250S-24YZ [MPD]
Single Output 250W Power Factor Corrected AC/DC Power Supplies;型号: | MPU-250S-24YZ |
厂家: | MICROPOWER DIRECT, LLC |
描述: | Single Output 250W Power Factor Corrected AC/DC Power Supplies |
文件: | 总2页 (文件大小:524K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series
MPU-250
Single Output 250W
Power Factor Corrected
AC/DC Power Supplies
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
Parameter
• Small 250W Supply
• PFC to EN 61000-3-2 “A”
• EN 60950 Approved (UL)
• CE Certified
Conditions
Min.
90
180
47
Typ.
Max.
132
264
63
Units
VAC
Hz
Input Voltage Range
Input Frequency
Autoranging
110 VAC
220 VAC
110 VAC
220 VAC
264 VAC
6
3
Input Current, Full Load
A
• FCC Class B Emissions
• 90 to 264 VAC Input
• Small 5” x 3.2” x 1.5” Size
35
70
1.0
Inrush Current, Cold Start
A
Leakage Current
mA
Power Factor Correction
Input Protection
Meets EN 61000-3-2 Class A
T8A/250V Fuse
Output
Parameter
Conditions
Min.
Typ.
5.0
1.0
Max.
Units
%
%
Output Voltage Adjustment
Output Regulation
By Trim Pot
See Note 1
Hold Time
110 VAC, 80% Load
20
mSec
Ripple & Noise (20 MHz) See Note 2
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time, See Note 4
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
See Model Selection Guide
Autorecovery 110
>130% of Rated Output Voltage. Recycle AC Input.
140
%
Autorecovery
+110
0.04
2.5
ºC
%/ºC
mS
%
%
S
50% Load Change
5
5.0
1
At Turn On/Off
230 VAC
Output Short Circuit
General
Continuous With Autorecovery
Parameter
Conditions
Min.
Typ.
Max.
Units
VAC
kHz
Input - Output 3,000
Input - FG (Frame Ground) 1,500
Primary - Core 1,500
Fixed
Isolation Voltage, See Note 5
Switching Frequency
Interface Signals
Power Supply On
25
Green LED on the PCB
Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS
before the loss of regulation.
Power Good Signal
Remote On/Off
A TTL low signal inhibits the output. Hiccup mode.
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Environmental
Parameter
Conditions
Min.
0
Typ.
+25
Max.
+70
Units
ºC
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Reliability Specifications
Parameter
Ambient
2.5%/ ºC from +50 ºC to + 70 ºC
-20
See Model Selection Guide
RH, Non-condensing
+85
ºC
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
90
%
Conditions
MIL HDBK 217F, 30ºC, Gnd Benign
Min.
100
Typ.
Max.
Units
kHours
MTBF
Safety Standards
EMI Compliance
EMS Immunity Compliance
Vibration
UL 60950, EN 60950
Compliance to EN 55022 (CISPR22) Class B; EN 61000-3-2,3
EN 61000-4-2,3,4,5,6,11; EN 55024; CE Marked (LVD)
Sinusoidal 5~50 Hz, Acceleration 7.35 m/s2 on X, Y & Z Axis
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Notes:
Output Voltage (VDC) Output Current (Max A)
Ripple
& Noise
(% p-p)
1. Output regulation includes line & load.
Model
Number
Efficiency
2. Ripple & noise is measured from 10 kHz to 20 MHz. Connection to the unit is made with
a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel.
3. A 1% minimum load is required to maintain regulation & ripple specifications.
4. Transient recovery is measured to within a 1% error band for a load step of 50% to 100%.
5. Isolation specifications are production HI-Pot tested for 3 seconds.
With
(%)
PreSet
Range
Convection
16 CFM
MPU-250S-12YZ 12 VDC 11.0 - 13.8
MPU-250S-15YZ 15 VDC 14.0 - 15.5
MPU-250S-24YZ 24 VDC 21.0 - 26.0
MPU-250S-36YZ 36 VDC 35.0 - 42.0
11.25
9.00
5.62
3.75
20.83
16.66
10.41
5.21
1%
1%
1%
1%
83%
83%
83%
83%
6. The full output range (see table) is covered in the safety agency certification. Standard
models are factory set to the Preset voltage,but may be set to other levels within the range
without affecting the agency certification. For more information, contact the factory.
7. Output power is given for the factory preset voltage. The maximum continuous output
power level is 135W without providing 16 CFM airflow. All models provide a peak power
level of 600W for a maximum duration of 500 µS.For more information,contact the factory.
8. Each unit includes an input fuse (250V/8A). Since this fuse is not field replaceable, it is
recommended that an external fuse of the same size be used on the input of the power
supply for protection.
Model Number
Models with other output voltage levels
are available (i.e. 5 VDC, 48 VDC, etc)
Contact the factory for details at:
sales@micropowerdirect.com
Mechanical Dimensions
Connections
Input Connector (CN1):
• Terminal Block:
Howder HD-601-3P
3 pins, 6.35 mm Centers
• Molex Mating Part No:
Molex 09-91-0500 or equivalent
(two pins removed)
Pin
Function
1
2
3
AC-Line
AC-Neutral
Field Ground
Output Connector (CN2):
• Terminal Block:
Howder HD-601-4P
4 pins, 6.35 mm Centers
• Molex Mating Part No:
Molex 09-91-0600 or equivalent
Pin
Molex
Pin Howder
1
2
3
4
5
6
+VOUT
+VOUT
+VOUT
-VOUT
-VOUT
-VOUT
1
2
3
4
+VOUT
+VOUT
-VOUT
-VOUT
Logic Signal Connector (CN3):
• Mating Part No:
JST XHP-3 or equivalent
(CHYAO SHIUNN JS-2001-03)
• Mating Pins: JST SXH-002T-PO.6
For AWG 30 to 26
U-Chassis Cover (C Suffix)
Pin
Function
1
2
3
Power Good
Remote On/Off
Common
Fan Driver Connector (CN4):
• Mating Part No:
JST XHP-2 or equivalent
(CHYAO SHIUNN JS-2001-2)
Pin
Function
1
2
Minus
Plus
Notes:
MicroPower Direct
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.02 ( 0.50)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明