18AS2-43-R [MSYSTEM]

Rack-mounted DCS Signal Conditioners 18-RACK;
18AS2-43-R
型号: 18AS2-43-R
厂家: M-SYSTEM    M-SYSTEM
描述:

Rack-mounted DCS Signal Conditioners 18-RACK

DCS 分布式控制系统
文件: 总4页 (文件大小:125K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: 18AS2  
(connector output not available)  
Rack-mounted DCS Signal Conditioners 18-RACK  
6: Hi/Lo; N.C., OFF in power failure  
(connector output not available)  
0: Specify  
DC ALARM  
Functions & Features  
• Providing relay contact closures at preset DC input levels  
• Single or dual (Hi/Lo) trip  
POWER INPUT  
DC Power  
• Frontaccessed screwdriver setpoint adjustments  
• Enclosed relays  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
Typical Applications  
• Annunciator  
GENERAL SPECIFICATIONS  
Construction: Rack-mounted; terminal access via screw  
terminals on the front and connector on the rear; terminal  
cover provided  
• Various alarm applications  
Connection  
Input: M3.5 screw terminals (torque 0.8 N·m)  
Alarm output: M3.5 screw terminals (torque 0.8 N·m) and  
connector  
Power input: Supplied from connector  
Screw terminal: Nickel-plated steel  
Isolation: Input to output to power  
Relay: Enclosed  
MODEL: 18AS2–[1][2]–R  
Setpoint adjustments: Multi-turn screwdriver adjustments  
(front); -5 – +105 % independently  
Hysteresis (deadband): Approx. 1 %  
Front LEDs: Red LED turns on when the coil is energized.  
ORDERING INFORMATION  
• Code number: 18AS2-[1][2]-R  
Specify a code from below for each of [1] and [2].  
(e.g. 18AS2-62-R)  
• Special input range (For code 0)  
INPUT SPECIFICATIONS  
DC Current: Input resistor incorporated  
DC Voltage: 0 – 300 V DC  
Minimum span: 1 V  
Use Ordering Information Sheet (No. ESU-1033) to specify  
alarm output code 0 specifications.  
Offset: Max. 1.5 times span  
Input resistance: ≥ 1 MΩ  
[1] INPUT  
Current  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
D: 0 – 20 mA DC (Input resistance 50 Ω)  
G: 0 – 1 mA DC (Input resistance 1000 Ω)  
H: 10 – 50 mA DC (Input resistance 100 Ω)  
Voltage  
3: 0 – 1 V DC (Input resistance 1 MΩ min.)  
4: 0 – 10 V DC (Input resistance 1 MΩ min.)  
5: 0 – 5 V DC (Input resistance 1 MΩ min.)  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
0: Specify voltage (See INPUT SPECIFICATIONS)  
[2] ALARM OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
5: Hi/Lo; N.O., OFF in power failure  
18AS2 SPECIFICATIONS  
ES-1769 Rev.3 Page 1/4  
http://www.m-system.co.jp/  
MODEL: 18AS2  
OUTPUT SPECIFICATIONS  
Output: Enclosed SPST and SPDT relays  
Rating:  
30 V DC @ 1 A (resistive load)  
0.2 A for the connector output  
Maximum switching voltage: 30 V DC  
Max. switching power: 30 W (6 W for the connector output)  
Minimum load: 5 V DC @ 10m A  
Mechanical life: 5 × 10 cycles  
7
Single Alarm  
Front terminals  
5 – 6  
ON  
5 – 7  
OFF  
ON  
Energized  
De-energized (or power OFF)  
OFF  
Rear connector  
ALARM  
OUTPUT  
CODE  
POWER ON  
POWER OFF  
IN < SET  
OFF  
IN > SET  
ON  
1
2
3
4
OFF  
ON  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
Dual Alarm (front terminals)  
POWER ON  
ALARM  
POWER OFF  
5 – 6 7 – 8  
IN < SET  
IN > SET  
OUTPUT  
CODE  
5 – 6 7 – 8 5 – 6 7 – 8  
5
6
ON  
OFF  
ON  
OFF  
ON  
ON  
OFF OFF  
OFF OFF  
OFF  
OFF  
Shades indicates that the relay is energized.  
INSTALLATION  
Current consumption: Approx. 80 mA  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Standard Rack 18BXx or 18KBXx  
Weight: 150 g (0.33 lb)  
PERFORMANCE in percentage of span  
Trip point repeatability: ±0.1 %  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Response time: ≤ 0.5 sec. (0 – 100 % at 90 % setpoint)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute  
(input to output or power)  
500 V AC @ 1 minute (output to power)  
1500 V AC @ 1 minute (input or output or power to ground)  
18AS2 SPECIFICATIONS  
ES-1769 Rev.3 Page 2/4  
http://www.m-system.co.jp/  
MODEL: 18AS2  
EXTERNAL VIEW  
SINGLE ALARM  
DUAL ALARM  
7
8
7
8
Indicator  
Hi Alarm Indicator  
5
1
6
5
1
6
2
High Setpoint Adj.  
Low Setpoint Adj.  
Lo Alarm Indicator  
Setpoint Adj.  
2
3
4
3
4
EXTERNAL DIMENSIONS unit: mm (inch)  
2–M3  
SCREW  
8–M3.5  
7 (.28)  
SCREW  
7 (.28)  
24 (.94)  
32 (1.26)  
78 (3.07)  
TERMINAL ASSIGNMENTS  
7
8
5
6
1
2
3
4
18AS2 SPECIFICATIONS  
ES-1769 Rev.3 Page 3/4  
http://www.m-system.co.jp/  
MODEL: 18AS2  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
SINGLE ALARM  
Relay Protection  
• AC Powered  
SETPOINT ADJ.  
Inductive  
Load (Coil)  
5
6
7
8
COM  
Low Drift  
Amplifier  
+
1
2
3
4
Ry  
Comparator  
Varistor or Spark  
Quenching Circuit  
**  
*
H
L
OUTPUT  
INPUT  
LOAD  
U
• DC Powered  
Inductive  
Load (Coil)  
**  
HI / LO  
Output  
Diode, Varistor or  
CR Circuit  
LOAD  
POWER  
DUAL ALARM  
SETPOINT ADJ.  
Comparator  
**  
**  
5
6
7
8
Low Drift  
Amplifier  
LO OUTPUT  
HI OUTPUT  
+
1
2
3
4
Ry  
Ry  
*
INPUT  
Comparator  
SETPOINT ADJ.  
POWER  
* Input shunt resistor incorporated for current input.  
**Relay status is determined by output codes.  
Specifications are subject to change without notice.  
18AS2 SPECIFICATIONS  
ES-1769 Rev.3 Page 4/4  
http://www.m-system.co.jp/  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY