18KYC-AA-R/S [MSYSTEM]

Rack-mounted DCS Signal Conditioners 18K-RACK;
18KYC-AA-R/S
型号: 18KYC-AA-R/S
厂家: M-SYSTEM    M-SYSTEM
描述:

Rack-mounted DCS Signal Conditioners 18K-RACK

DCS 分布式控制系统
文件: 总3页 (文件大小:103K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: 18KYC  
Input: Connector  
Rack-mounted DCS Signal Conditioners 18K-RACK  
Input monitor: M3.5 screw terminals (torque: 0.8 N·m)  
Output: M3.5 screw terminals (torque: 0.8 N·m) and  
connector  
CONTROL OUTPUT ISOLATOR  
Functions & Features  
Power: Supplied from connector  
• Takes 4 - 20 mA DC as input  
Screw terminal: Nickel-plated steel  
Isolation: Input to output to power  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
Opencircuit detection: input current 0 mA when the output  
loop is open.  
• Opencircuit detection  
• Module can be retracted without removing wiring for an  
insulation test  
• Capable of monitoring input signals at front terminals  
• Optional power switch  
OUTPUT SPECIFICATIONS  
The output goes below 0 % when the input is open.  
INSTALLATION  
Current consumption: Approx. 50 mA  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Standard Rack 18KBXx  
Weight: 150 g (0.33 lb)  
MODEL: 18KYC–AA–R[1]  
ORDERING INFORMATION  
Code number: 18KYC-AA-R[1]  
Specify a code from below for [1].  
(e.g. 18KYC-AA-R/S)  
PERFORMANCE in percentage of span  
Accuracy: ±0.1 %  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Response time: ≤ 0.5 sec. (0 – 90 %)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 500 V AC @ 1 minute (input to output to  
power to ground )  
INPUT  
Current  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
OUTPUT  
Current  
A: 4 – 20 mA DC (Load resistance 600 Ω max.)  
POWER INPUT  
DC Power  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
[1] OPTIONS  
Power Switch  
blank: None  
/S: With power switch  
GENERAL SPECIFICATIONS  
Construction: Rack-mounted; terminal access via screw  
terminals on the front and connector on the rear; terminal  
cover provided  
Connection  
18KYC SPECIFICATIONS  
ES-0489 Rev.1 Page 1/3  
http://www.m-system.co.jp/  
MODEL: 18KYC  
EXTERNAL VIEW  
WITH POWER SWITCH  
7
8
5
6
2
Power Switch  
Span Adj.  
Zero Adj.  
1
3
4
EXTERNAL DIMENSIONS unit: mm (inch)  
2–M3  
SCREW  
8–M3.5  
7 (.28)  
SCREW  
7 (.28)  
24 (.94)  
32 (1.26)  
78 (3.07)  
TERMINAL ASSIGNMENTS  
7
8
5
6
1
2
3
4
18KYC SPECIFICATIONS  
ES-0489 Rev.1 Page 2/3  
http://www.m-system.co.jp/  
MODEL: 18KYC  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Z
S
Isolation  
250Ω  
Low Drift  
Amplifier  
Voltage  
Duty Cycle  
Output  
Driver  
Opencircuit  
Detector  
5
6
3
4
7
8
1
2
+
INPUT MONITOR  
Module Field Terminals  
(Section A)  
To External Field Terminals  
(Section A)  
INPUT (DCS Output)  
*
POWER  
* With power switch only  
Use either of module or external field terminals.  
Section A. Field Terminals  
+
1
2
OUTPUT  
Specifications are subject to change without notice.  
18KYC SPECIFICATIONS  
ES-0489 Rev.1 Page 3/3  
http://www.m-system.co.jp/  

相关型号:

18KYCH

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KYCH-AA-R

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KYCH-AA-R/B

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KYCH-AA-R/S

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KYS

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KYS-66-R

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KYS-66-R/S

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KYS-6A-R

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KYS-6A-R/S

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18L-03P-044

Circular DIN Connector, 3 Contact(s), Male, Board Mount, Printed Wiring Pin Terminal, Plug
AMPHENOL

18L-03P-131

Circular DIN Connector, 3 Contact(s), Male, Board And Cable Mount, Plug
AMPHENOL

18L-03P-231

Circular DIN Connector, 3 Contact(s), Male, Board And Cable Mount, Plug
AMPHENOL