22LS1-3-S [MSYSTEM]
Telemetering System;型号: | 22LS1-3-S |
厂家: | M-SYSTEM |
描述: | Telemetering System |
文件: | 总7页 (文件大小:187K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: 22LS1
Telemetering System
RELATED PRODUCTS
• Multi-transmission module
Model: 22LA1
MODEM INTERFACE
(SIN-NET use)
• RS cable
Model: DCN5
Functions & Features
• Modem
• Interfacing between SIN-NET devices (models:
22LA1, DLA1) and a modem for leased circuit
• Simple configuration by setting Station No. for pairing
units with the front rotary witches
Model: MOD1, MOD2, MOD3x, MOD4, MOD5, MOD6, MOD7,
MOD8
• Combined with M-System's modems for leased circuit
GENERAL SPECIFICATIONS
Construction: Plug-in
Typical Applications
Connection
• 1-to-1 transmission system
• 1-to-N transmission system
Power input: M3.5 screw terminals
SIN-NET, RUN contact output: Euro type connector
terminal block
RS-232-C: 9-pin D-sub connector (female)
(M2.6 x 0.45 connector screw)
50
(1.97)
Housing material: Flame-resistant resin (black)
Isolation: RS-232-C to SIN-NET to RUN contact output to
power
PWR
80
8
RUN
7
6
5
4
3
2
1
(3.15)
4
5
7
3
3
1
8
0
9
F
B
C
D
SA1
SA2
4
5
7
1
8
DIP switches: selecting modem type (SW1 – 4) and
Master/Slave (SW8)
0
9
F
B
D C
RS-232-C
Terminator: Incorporated (remove jumper pin with those
modules not located at the end of transmission line)
Station No. setting: 2 rotary switches; 00 – FF (256)
Power indicator: Red LED turns ON in normal conditions;
OFF when the voltage level becomes low.
RUN indicator: Red LED turns ON when the selfdiagnosis
proves normal, OFF in an abnormality.
RUN contact output: Contact opens in an abnormality.
125 V AC @ 0.5A (cosø = 1)
144
(5.67)
mm (inch)
MODEL: 22LS1–3–[1]
ORDERING INFORMATION
• Code number: 22LS1-3-[1]
Specify a code from below for [1].
(e.g. 22LS1-3-K)
30 V DC @ 0.5A (resistive load)
Maximum switching voltage: 250 V AC or 125 V DC
Maximum switching power: 62.5 VA or 60 W
Minimum load: 10 mV DC @ 1 mA
TRANSMISSION MEDIA
3: Twisted-pair cable for small-scale system
Mechanical life: 5 × 10
7
cycles (rate 180/min.)
Self-diagnosis
Communication: receiving 'loss of RS-232-C
communication' data; multiplex transmission
error data; network error
[1] POWER INPUT
AC Power
K: 85 – 132 V AC
CPU: watch-dog timer
(Operational voltage range 85 – 132 V, 47 – 66 Hz)
L: 170 – 264 V AC
Power voltage: detects when the voltage supply to the CPU
drops.
(Operational voltage range 170 – 264 V, 47 – 66 Hz)
DC Power
S: 12 V DC
MULTI-TRANSMISSION
Communication: 2-wire, half-duplex
Transmission: conform to RS-422, EIA
Transmission speed: 125 kbps
Data encoding: SDLC
(Operational voltage range 12 V ±10 %, ripple 10 %p-p max.)
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
Control procedure: NRZ
Protocol: SIN-NET (M-System's)
22LS1 SPECIFICATIONS
ES-6557 Rev.6 Page 1/7
http://www.m-system.co.jp/
MODEL: 22LS1
Error check: CRC
Cable: CPEV-0.9 dia.
Transmission distance: 500 meters
MODEM / INTERFACE
Transmission: Conform to EIA RS-232-C
Communication: asynchronous, half-duplex, no procedure
Transmission speed: 50 – 2400 bps
RS-232C connector: 9-pin D-sub connector (female)
RS-232-C cable: Cross (provided by the user)
INSTALLATION
Power consumption
•AC: Approx. 4.5 VA
•DC: Approx. 4 W (160 mA at 24 V)
Operating temperature: -5 to + 50°C (23 to 122°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Surface or DIN rail
Weight: 400 g (0.88 lb)
PERFORMANCE
Permissible power failure duration: ≤ 10 msec.
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 500V AC @1 minute
(RS-232-C to SIN-NET to RUN contact output)
1500V AC @1 minute
(power to RS-232-C or SIN-NET or RUN contact output)
1500V AC @1 minute (FG to each section)
22LS1 SPECIFICATIONS
ES-6557 Rev.6 Page 2/7
http://www.m-system.co.jp/
MODEL: 22LS1
DESCRIPTIONS
■HOW TO SET STATION ADDRESSES
All units are connected in a series via a couple of modems. Assign to the pair of 22LS1 a number remote from those for 22LA1
units (such like FF, FE).
■DIP SWITCH SETTING
A) Modem type selecting:
Set SW1 through SW4 according to the type of modem combined with the 22LS1.
Transmission speed and format appropriate for each modem type are determined. If you change these settings, turn power
supply to the unit off and on.
B) Master/Slave selecting:
Set SW8 of a 22LS1 unit to Master and one of the paired unit to Slave.
If you change these settings, turn power supply to the unit off and on.
■HOW TO CALCULATE TRANSMISSION SPEED
A) When the total number of inputs at one side of the pair of modems (one station) is at the maximum of 256 in contact and 32
in analog:
N1: number of 22LA1-3A4 units
N2: number of 22LA1-3E5/-3E6 units
N3: number of 22LA1-3G3 units
N4: number of 22LA1-3G4 units
The number of input units (N1 to N4) determines Data Volume:
•Contact Inputs
B1 = (N1 + N2) × 6
•Analog Inputs
B2 = (N3 + N4) × 3 + (N3×8 + N4×4) × 2
•Total Data Volume
C0 = 5 + B1 + B2
Relation between the Total Data Volume and a time (Ta) required to transmit from one station (Master Station) is shown in the
following equation:
Ta = C0 × A
where A is a parameter determined by the transmission speed of modems:
A = 0.2933 (50 bps)
A = 0.0333 (300 bps)
A = 0.0083 (1200 bps)
A = 0.0042 (2400 bps)
The transmission speed (Tb) for the other station (Slave Station) can be calculated in the same way.
Actual time (TA) required for a contact (or analog) input to be transmitted from Master Station to Slave Station varies according
to timings of signal status change and transmission status, if there is no transmission error.
Ta ≤ TA ≤ Ta + Ta + Tb
B) When the total number of inputs at one side of the pair of modems (one station) is at the maximum of 256 in contact and 64
in analog:
When the total number of analog inputs exceeds 32, the 22LS1 divides them for transmission. Therefore time required for
transmitting analog and contact signals are different.
N1: number of 22LA1-3A4 units
N2: number of 22LA1-3E5/-3E6 units
N3: number of 22LA1-3G3 units
N4: number of 22LA1-3G4 units
The number of input units (N1 to N4) determines Data Volume:
•Contact Inputs
B1 = (N1 + N2) × 6
•Analog Inputs, first group
B2 = 88
•Analog Inputs, second group
22LS1 SPECIFICATIONS
ES-6557 Rev.6 Page 3/7
http://www.m-system.co.jp/
MODEL: 22LS1
B3 = [(N3 + N4) × 3 – 24] + (N3×8 + N4×4 – 32) × 2
•Total Data Volume, first group
C1 = 5 + B1 + B2
•Total Data Volume, second group
C2 = 5 + B1 + B3
•Contact Inputs
Relation between the Total Data Volume and a time (Ta) required to transmit contact inputs from one station (Master Station) is
shown in the following equation:
Ta = C1 × A
where A is a parameter determined by the transmission speed of modems (see A).
The transmission speed (Tb) for the other station (Slave Station) can be calculated in the same way.
Actual time (TA) required for a contact input to be transmitted from Master Station to Slave Station varies according to timings
of signal status change and transmission status, if there is no transmission error.
Ta ≤ TA ≤ Ta + Ta + Tb
•Analog Inputs
Relation between the Total Data Volume and a time (Ta) required to transmit analog inputs from one station (Master Station) is
shown in the following equation:
Ta = (C1 + C2) × A
where A is a parameter determined by the transmission speed of modems (see A).
The transmission speed (Tb) for the other station (Slave Station) can be calculated in the same way.
Acutal time (TA) required for a contact input to be transmitted from Master Station to Slave Station varies according to timings
of signal status change and transmission status, if there is no transmission error.
Ta ≤ TA ≤ Ta + Ta + Tb
■RUN CONTACT OUTPUT
RUN contact is turned off when one or more of the following three conditions occur:
•Failure of the 22LS1
Errors in power supply, memory, etc.
•SIN-NET communication errors
When there is an error occurs to 22LA1 or DLA1 units connected to the 22LS1.
•RS-232-C communication errors
When there is an error occurs in communication with the modem connected to the 22LS1 (communicating with the paired
22LS1 via leased circuit), such like wire breakdown.
[CAUTION]
When the network is reconfigured e.g. by noise interference,
the RUN LED and output for all units on the
network turn briefly OFF until they are turned ON after the reconfiguration is complete.
22LS1 SPECIFICATIONS
ES-6557 Rev.6 Page 4/7
http://www.m-system.co.jp/
MODEL: 22LS1
EXTERNAL VIEW
DIP Switches
Power Indicator LED
RUN Indicator LED
Master/Slave Selecting
8
7
6
5
4
3
2
1
PWR
RUN
Modem Type Selecting
Station No. Setting
Rotary Switches
SA1
SA2
ON
Euro Type Connector Terminal
Jumper Pin
A
B
C
D
E
F
LINE
RT
RUN
RS-232-C Connector
■ RS-232-C INTERFACE
ABBR. PIN NO. EXPLANATION OF FUNCTION
CF (CD)
BB (RD)
BA (SD)
1
2
3
Received Line Signal Detector
Received Data
Transmitted Data
1
5
6
9
CD (ER)
AB (SG)
CC (DR)
4
5
6
DTE Ready
Signal Common
DCE Ready
CA (RS)
CB (CS)
(RI)
7
8
9
Request to Send
Clear to Send
(Not Used)
• RS-232-C Connection Example
Modem
(model: MODx)
Modem Interface
(model: 22LS1)
1
1
2
3
4
5
6
7
8
9
CF (CD)
BB (RD)
BA (SD)
CD (ER)
AB (SG)
CC (DR)
CA (RS)
CB (CS)
(RI)
2
3
4
5
6
7
8
20
(SD) BA
(RD)BB
(RS)CA
(CS)CB
(DR)CC
(SG)AB
(CD)CF
(ER)CD
Use a cross-type cable as shown above.
CONNECTION DIAGRAM
TWISTED PAIR
+
–
A
B
C
D
E
F
RS-232-C
JUMPER PIN*
TERMINATOR
RUN CONTACT
OUTPUT
U(+)
V(–)
7
8
9
POWER
GROUNDING FG
*When the unit is located at the end of transmission line via
twisted-pair cable (= no cross-wiring), short across the terminals
C – D with the jumper pin (or wire) provided with the unit.
Remove the jumper pin for the one not located at the end.
22LS1 SPECIFICATIONS
ES-6557 Rev.6 Page 5/7
http://www.m-system.co.jp/
MODEL: 22LS1
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
CLAMP
(top & bottom)
7.8 (.31)
DIN RAIL
35mm wide
8
7
6
5
4
2–4.5 (.18) dia.
MTG HOLE
25 (.98) deep
9
3
2
10 11
1
11–M3.5
SCREW
50 (1.97)
12 (.47)
103 (4.06)
132 (5.20)
40 (1.57)
50 (1.97)
80 (3.15) min.
[3.3 (.13)]
•When mounting, no extra space is needed between units.
SYSTEM CONFIGURATION EXAMPLES
■ 1 to 1 TRANSMISSION
Master Station Control Room
Local (Slave) Station
300 bps
Modem
Model: MOD2
300 bps
Modem
Model: MOD2
SIN-NET
SIN-NET
Leased Circuit
Multi-Transmission
Module
Model: 22LA1
Modem
Interface
Model: 22LS1
Modem
Interface
Model: 22LS1
Multi-Transmission
Module
Model: 22LA1
■ 1 to N TRANSMISSION
Master Station Control Room
Slave Sta. 1
SIN-NET
Model: MOD2
Model: MOD2
Leased Circuit
SIN-NET
Model: 22LS1
Model: 22LA1
Slave 1 Outputs
Slave Sta. 2
Model: 22LS1
Slave 2 Outputs
Slave Sta. n
Model: 22LA1
Slave "n" Outputs
22LS1 SPECIFICATIONS
ES-6557 Rev.6 Page 6/7
http://www.m-system.co.jp/
MODEL: 22LS1
Specifications are subject to change without notice.
22LS1 SPECIFICATIONS
ES-6557 Rev.6 Page 7/7
http://www.m-system.co.jp/
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明