60M-161-R [MSYSTEM]

Field Network Modules 60-UNIT Series;
60M-161-R
型号: 60M-161-R
厂家: M-SYSTEM    M-SYSTEM
描述:

Field Network Modules 60-UNIT Series

文件: 总5页 (文件大小:185K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: 60M  
Field Network Modules 60-UNIT Series  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
ANALOG I/O MODULE  
(Modbus; RS-485)  
/C02: Polyurethane coating  
/C03: Rubber coating  
Functions & Features  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
• Interfacing analog I/O signals from/to 10-RACK or 18-RACK  
modules with Modbus  
• Saving power and I/O wiring inside an instrumentation  
panel  
RELATED PRODUCTS  
•Special cable (model: MCN34)  
72  
(2.83)  
PACKAGE INCLUDES...  
• Terminating resistor (110 Ω, 0.25 W)  
80  
(3.15)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection  
153  
(6.02)  
Modbus: Euro type connector terminal (applicable wire  
mm (inch)  
size: 0.2 to 2.5 mm , stripped length 7 mm)  
2
I/O: 34-pin connector (OMRON XG4A-3434)  
Power input: M3.5 screw terminal  
Screw terminal: Chromated steel (standard) or stainless  
steel  
MODEL: 60M-16[1]-[2][3]  
Housing material: Flame-resistant resin (black)  
Isolation: I/O to Modbus to power to FG1  
Power indicator: Green LED turns on with power supplied.  
ORDERING INFORMATION  
• Code number: 60M-16[1]-[2][3]  
Specify a code from below for each [1] through [3].  
(e.g. 60M-161-K/Q)  
MODBUS COMMUNICATION  
Communication: Conforms to TIA/EIA-485-A  
Transmission setting: DIP switch  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
Data: RTU (Binary) or ASCII  
NO. OF CHANNELS  
Parity: none, even or odd  
16: 16 points  
Baud rate: 4800, 9600, 19.2 k, 38.4 k (bps)  
Node address setting: Rotary switch; 01 – F7  
(factory setting: 00)  
[1] I/O TYPE  
1: Input  
L RUN indicator: Red LED turns on for 10 sec. when the  
module receives data.  
2: Output  
L ERR. indicator: Red LED turns on at errors in parity,  
framing, overrun, CRC or LRC.  
[2] POWER INPUT  
AC Power  
SD indicator: Red LED turns on when transmitting.  
RD indicator: Red LED turns on when receiving.  
Analog input: Programming Unit (model: PU-2x) or via  
Modbus  
K: 85 – 132 V AC  
(Operational voltage range 85 – 132 V, 47 – 66 Hz)  
DC Power  
Moving averaging: None, every 2 or 4 samples  
Sampling rate: 400, 240, or 160 (msec.)  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
[3] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
60M SPECIFICATIONS  
ES-6606 Rev.12 Page 1/5  
http://www.m-system.co.jp/  
MODEL: 60M  
Floating data (4-byte data)  
INPUT SPECIFICATIONS  
Analog Input  
Initial signal range 0 – 100 % is proportional to 0 – 10000,  
that is possible to be scaled into a specific range.  
Input range: 1 – 5 V DC  
Input resistance: ≥ 1 MΩ  
Output Connector Pin Assignment  
10-RACK and 18-RACK I/O modules must be isolated types.  
Non-isolated modules such as 10BW and 18BW are not  
usable.  
PIN NO.  
1
ASSIGNMENT  
PIN NO.  
2
ASSIGNMENT  
COM  
Output  
Output  
Output  
Output  
Output  
Output  
Output  
Output  
Output  
1
2
3
4
5
6
7
8
9
3
4
COM  
5
6
COM  
A/D Conversion Output  
7
8
COM  
Signed binary (2-byte data)  
9
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
32  
34  
COM  
Signal range 0 – 100 % is proportional to hexadecimal 0000  
– 2710 (0 – 10000). -15 to 0 % is a negative range  
represented by 2's complements.  
11  
13  
15  
17  
19  
21  
23  
25  
27  
29  
31  
33  
COM  
COM  
COM  
COM  
Overall range is represented by hexadecimal FA24 – 2CEC  
(-1500 – +11500), for -15 – +115 %.  
Floating data (4-byte data)  
Output 10  
Output 11  
Output 12  
Output 13  
Output 14  
Output 15  
Output 16  
No connection  
COM  
COM  
COM  
Initial signal range 0 – 100 % is proportional to 0 – 10000,  
that is possible to be scaled into a specific range.  
COM  
COM  
COM  
Input Connector Pin Assignment  
COM  
PIN NO.  
1
ASSIGNMENT  
PIN NO.  
2
ASSIGNMENT  
COM  
No connection  
Input  
Input  
Input  
Input  
Input  
Input  
Input  
Input  
Input  
1
2
3
4
5
6
7
8
9
3
4
COM  
5
6
COM  
INSTALLATION  
Power consumption  
7
8
COM  
9
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
32  
34  
COM  
AC: Approx. 4 VA  
11  
13  
15  
17  
19  
21  
23  
25  
27  
29  
31  
33  
COM  
DC: Approx. 4 W (160 mA)  
COM  
COM  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: Surface or DIN rail  
COM  
Input 10  
Input 11  
COM  
COM  
Input 12  
COM  
Weight: 450 g (0.99 lb)  
Input 13  
COM  
Input 14  
COM  
Input 15  
COM  
PERFORMANCE in percentage of span  
A/D conversion: ±0.1 %  
Input 16  
COM  
No connection  
No connection  
D/A conversion: ±0.1 %  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Permissible power failure duration: ≤ 10 msec.  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute (input or output  
to Modbus to power)  
OUTPUT SPECIFICATIONS  
Analog Output  
Output must be isolated with signal conditioners.  
When the transmission line is open, the last value sampled  
before failure is held.  
2000 V AC @ 1 minute (input or output or Modbus or power  
to FG1)  
Output range: 1 – 5 V DC  
Load resistance: 20 kΩ minimum  
10-RACK and 18-RACK I/O modules must be isolated types.  
Non-isolated modules such as 10BW and 18BW are not  
usable.  
D/A Conversion Input  
Signed binary (2-byte data)  
Signal range 0 – 100 % is proportional to hexadecimal 0000  
– 2710 (0 – 10000). -15 to 0 % is a negative range  
represented by 2's complements.  
Overall range is represented by hexadecimal FA24 – 2CEC  
(-1500 – +11500), for -15 – +115 %.  
60M SPECIFICATIONS  
ES-6606 Rev.12 Page 2/5  
http://www.m-system.co.jp/  
MODEL: 60M  
EXTERNAL VIEW  
CN1  
Modular Jack  
for Factory Calibration  
Power Indicator LED  
L RUN  
L ERR.  
SD  
Status Indicator LED  
I/O Connector  
PWR  
RD  
4
C
C
Node Address Setting  
Transmission Setting  
4
Euro Type Connector Terminal  
for Modbus  
1
2
3
4
5
6
MODBUS FUNCTION CODES & SUPPORTED CODES  
Data and Control Functions  
CODE  
01  
NAME  
Read Coil Status  
X
X
X
X
X
X
Digital output from the slave  
02  
Read Input Status  
Read Holding Registers  
Read Input Registers  
Force Single Coil  
Status of digital inputs to the slave  
General purpose register within the slave  
Collected data from the eld by the slave  
Digital output from the slave  
03  
04  
05  
06  
Preset Single Registers  
Read Exception Status  
Diagnostics  
General purpose register within the slave  
07  
08  
X
09  
Program 484  
10  
Poll 484  
11  
Fetch Comm. Event Counter  
Fetch Comm. Event Log  
Fetch a status word and an event counter  
A status word, an event counter, a message count and  
a eld of event bytes  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
Program Controller  
Poll Controller  
Force Multiple Coils  
Preset Multiple Registers  
Report Slave ID  
X
X
Digital output from the slave  
General purpose register within the slave  
Slave type / ‘RUN’ status  
Program 884 / M84  
Reset Comm. Link  
Read General Reference  
Write General Reference  
Mask Write 4X Register  
Read/Write 4X Registers  
Read FIFO Queue  
Exception Codes  
CODE NAME  
01  
02  
03  
04  
05  
06  
07  
08  
Illegal Function  
X
X
X
Function code is not allowable for the slave  
Address is not available within the slave  
Data is not valid for the function  
Illegal Data Address  
Illegal Data Value  
Slave Device Failure  
Acknowledge  
Slave Device Busy  
Negative Acknowledge  
Memory Parity Error  
60M SPECIFICATIONS  
ES-6606 Rev.12 Page 3/5  
http://www.m-system.co.jp/  
MODEL: 60M  
Diagnostic Subfunctions  
CODE NAME  
00  
01  
02  
03  
04  
Return Query Data  
X
X
X
X
X
Loop back test  
Restart Comm. Option  
Return Diagnostic Register  
Change ASCII Input Delimiter  
Force Listen Only Mode  
Reset the slave and clear all counters  
Contents of the diagnostic data (2 bytes)  
Delimiter character of ASCII message  
Force the slave into Listen Only Mode  
MODBUS I/O ASSIGNMENT  
TYPE  
ADDRESS  
DATA TYPE  
2
DATA  
1
X
X
X
X
X
X
Coil (0X)  
1 – 16  
17 – 32  
1 – 16  
Averaging SW *  
Sampling rate SW **  
Inputs (1X)  
X
X
Analog channel status (active channel)  
Analog status (out of range)  
Analog input  
17 – 32  
1 – 16  
Input Registers (3X)  
Holding Registers (4X)  
I
17 – 48  
1 – 16  
F
I
Analog input  
X
X
X
X
Analog output  
17 – 48  
49 – 80  
81 – 112  
F
F
F
Analog output  
X
X
Full scale  
Zero scale  
Type  
1
2
: Analog input  
: Analog output  
Data Type  
F
I
: Floating  
: Int 0 – 10000 (0 – 100%)  
*Averaging SW  
1
2
3
: 4 samples  
: 2 samples  
: None  
**Sampling rate SW  
17 : 400 millisec.  
18 : 240 millisec.  
19 : 160 millisec.  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
CLAMP  
(top & bottom)  
7.8 (.31)  
DIN RAIL  
35mm wide  
7
14  
6
5
12  
4
3
2–4.5 (.18) dia.  
MTG HOLE  
25 (.98) deep  
8
9
15 10  
1
11  
2
14–M3.5  
SCREW  
14  
72 (2.83)  
(.55)  
109 (4.29)  
139 (5.47)  
60 (2.36)  
72 (2.83)  
38 (1.50)  
[3.3 (.13)]  
•When mounting, no extra space is needed between units.  
60M SPECIFICATIONS  
ES-6606 Rev.12 Page 4/5  
http://www.m-system.co.jp/  
MODEL: 60M  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
COMMUNICATION MODULE  
INDICATOR ROTARY  
Terminator  
DA  
LED  
SW  
*
To 10-RACK,  
18-RACK etc.  
DB  
To Other  
Modbus  
Devices  
RS-485  
INTERFACE  
DG  
SLD  
FG  
TRANSMISSION  
SETTING  
A / D  
or  
D / A  
Conv.  
I / O  
CPU  
Modular Jack  
for Factory  
Calibration  
MODULAR JACK  
SERIAL  
TRANSMISSION  
LINE  
U(+)  
V(–)  
FG1  
7
14  
8
POWER  
*Attach the terminating resistor when the module is  
at the termination of a transmission line.  
■ COMMUNICATION CABLE CONNECTIONS  
HOST PC  
TERMINATOR  
Tx+ / Rx+  
ANALOG I/O MODULE  
ANALOG I/O MODULE  
DA  
DB  
DA  
DB  
Tx– / Rx–  
SG  
DG  
SLD  
FG  
DG  
SLD  
FG  
Rx+  
Rx–  
FG  
FG  
Specifications are subject to change without notice.  
60M SPECIFICATIONS  
ES-6606 Rev.12 Page 5/5  
http://www.m-system.co.jp/  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY