73VR3100-E-M2 [MSYSTEM]
Paperless Recording System;型号: | 73VR3100-E-M2 |
厂家: | M-SYSTEM |
描述: | Paperless Recording System |
文件: | 总14页 (文件大小:384K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: 73VR3100
Paperless Recording System
[2] POWER INPUT
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
PAPERLESS RECORDER
(Selectable input modules; TFT LCD display)
Functions & Features
47 – 66 Hz)
DC Power
R: 24 V DC
• 20 msec. storing rate with the combination of 8 analog
and 8 discrete inputs
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
• 0.1 sec. storing rate with 16 channels; 0.5 sec. with 64
channels
[3] OPTIONS
• Data stored in CF Cards and SD Cards
• Indicated interval data stored in USB memory as CSV file
operable (even during storing)
blank: none
/Q: With options (specify the specification)
• Memory card slot accessible at the front
• Dedicated application software to view and analyze the
data
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
• Touch panel operation
/C02: Polyurethane coating
• IP65 front panel
/C03: Rubber coating
• Display and storing of the data sent from PLC in
combination with Gateway module
• Setting and operation from PLC (Remote Mode)
INSTALLATION
/HA: Desktop type (with handle and feet)
(Desktop type cannot be mounted on a panel surface.
The handle and rubber feet cannot be detached.)
144 (5.67)
RELATED PRODUCTS
• PC Configurator cable (model: MCN-CON or COP-US)
• PC configurator software (model: R3CON)
• Clamp-on current sensor (model: CLSA, CLSB, CLSE)
• Special cable for the CLSA-08, -12 (model: CLSA-08C-30)
■ Memory card
144
(5.67)
245.1
(9.65)
A memory card is required to store data in the 73VR3100.
Available for purchase from M-System. Consult M-System
(except SD/CF conversion adapter).
M-System will not guarantee the product’s described
performance if a memory card other than purchased from M
-System, or specified below, is used.
• CF Card
mm (inch)
MODEL: 73VR3100-[1]-[2][3]
ORDERING INFORMATION
• Code number: 73VR3100-[1]-[2][3]
Specify a code from below for each of [1] through [3].
(e.g. 73VR3100-E-M2/Q)
1. Manufacturer: Hagiwara Solutions
Model No.: MCF10P-xxxxS
Capacity: 128 MB through 1 GB
(CFI-xxxxDG ... discontinued)
• I/O and network modules
2. Manufacturer: Apacer Technology
Model name: CFC III
(Use Ordering Information Sheet No. ESU-7397)
• Specify the specification for option code /Q
(e.g. /C01/HA)
Model No.: AP-CFxxxxE3NR-ETNDNRQ
Capacity: 256 MB through 1 GB
Part No.: 81.27L20.TB47C (256 MB)
81.29910.TB37C (512 MB)
[1] LANGUAGE
N: Japanese
81.29920.TB37C (1 GB)
(AP-CFxxxxE3ER-ETNDNR, AP-CFxxxxE3ER-ETNDNRK ...
discontinued)
E: English
• SD Card (Compatible with 73VR3100 Ver.6.02.xx or later)
Manufacturer: Hagiwara Solutions
Model No.: NSD6-004GH (B21SEI
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 1/14
http://www.m-system.co.jp/
MODEL: 73VR3100
(NSDA-004GT, NSDA-004GL ... discontinued)
SD/CF Conversion Adapter is required to use SD card. There
are some restrictions on using SD card. For details, refer to
the instruction manual.
TS8: Thermocouple input, 8 ch.
RS4: RTD input, 4 ch.
RS8: RTD input, 8 ch.
MS4: Potentiometer input, 4 ch.
MS8: Potentiometer input, 8 ch.
US4: Universal input, 4 ch.
• SD/CF Conversion Adapter (operation confirmed):
DeLOCK adaptor CF II to SDHC,SDXC
Model: 61796 (operation has been confirmed with the
adapter purchased in the year of 2016.)
DS4: 4 – 20 mA input with excitation, 4 ch.
DS4A: 4 – 20 mA input w/exc. (switch provided), 4 ch.
DS8N: 4 – 20 mA input with excitation, 8 ch., non-isolated
CT4: CT (AC current) input, 4 ch.
CT4A: AC current input, 4 ch., clamp-on current sensor CLSA
use
62637 (operation has been confirmed with the
adapter purchased in the year of 2018.)
Note: Refer to the data sheets of the respective models.
CT4B: AC current input, 4 ch., clamp-on current sensor CLSB
use
PACKAGE INCLUDES...
• 73VR Application Software CD (model: 73VRPAC2)
CT4C: AC current input, 4 ch., clamp-on current sensor CLSB
-R5 use
• Mounting brackets (two)
(/HA: Not included for desktop type)
CT8A: AC current input, 8 ch., clamp-on current sensor CLSA
use
I/O, INTERFACE I/O, AND NETWORK MODULE
■ COMMON INSTRUCTION
CT8B: AC current input, 8 ch., clamp-on current sensor CLSB
use
Use Ordering Information Sheet (No. ESU-7397) to specify
the types of I/O module, network module and interface I/O
module (gateway module). The total current consumption of
all mounted modules must be within 560 mA (continuous).
Please refer to the respective data sheet for detailed
specifications of each module.
CT8C: AC current input, 8 ch., clamp-on current sensor CLSB
-R5 use
PT4: PT (AC voltage) input, 4 ch.
CZ4: Zero-phase current input, 4 ch.
WT4: AC power input, 4 points
WT4A: AC power input, 4 ch., clamp-on current sensor CLSA
use
■ SELECTABLE I/O MODULES
R3 Series I/O modules as listed below are used for the
73VR3100.
WT4B: AC power input, 4 ch., clamp-on current sensor CLSB
use
WTU: AC power input, 2 ch., clamp-on current sensor CLSE
use (Communication Mode ‘S’only)
LC2: Strain gauge input, 2 ch.
● I/O MODULE
R3–[1][2]
Pulse Input
PA2: Encoder input, 2 ch. (speed and position)
PA4: High speed pulse input, 4 ch.
PA4A: High speed totalized pulse input, 4 ch.
PA4B: Low speed totalized pulse input, 4 ch.
PA8: Totalized pulse input, 8 ch.
PA16: Totalized pulse input, 16 ch.
Discrete Input
[1] MODEL
Analog Input
SS4: DC current input, 4 ch.
SS8: DC current input, 8 ch.
SS8N: DC current input, 8 ch., non-isolated
SS16N: DC current input, 16 ch., non-isolated
SV4: DC voltage input, 4 ch.
DA16: Optical isolation discrete input, 16 ch. (13 V DC)
Discrete Output
SV4A: DC voltage input, 4 ch., narrow span
SV4B: DC voltage input, 4 ch., wide span
SV4C: DC voltage input, 4 ch., wide span ±50 V
SV8: DC voltage input, 8 ch.
DC16: Relay output, 16 ch.
DC32A: Open collector output, 32 ch.
(Limited to two discrete output modules at the maximum.)
Discrete I/O
SV8A: DC voltage input, 8 ch., narrow span
SV8B: DC voltage input, 8 ch., wide span
SV8C: DC voltage input, 8 ch., wide span ±50 V
SV8N: DC voltage input, 8 ch., non-isolated
SV16N: DC voltage input, 16 ch., non isolated
TS4: Thermocouple input, 4 ch.
DAC16A: Discrete input output module (Di 8 ch., Do 8 ch.)
(Limited to one discrete I/O module at the maximum.)
Alarm
AS4: DC current input alarm, 4 ch.
AS8: DC current input alarm, 8 ch.
AV4: DC voltage input alarm, 4 ch.
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 2/14
http://www.m-system.co.jp/
MODEL: 73VR3100
AV8: DC voltage input alarm, 8 ch.
AT4: Thermocouple input alarm, 4 ch.
AR4: RTD input alarm, 4 ch.
or CLSB or CLSE).
The CLSA is used for the R3-CT4A and R3-CT8A and R3-
WT4A.
AD4: 4 – 20 mA input alarm w/exc., 4 ch.
Blank Filler Module
The CLSB is used for the R3-CT4B and R3-CT8B and R3-
WT4B.
DM: Blank filler module (Communication mode suffix code is
not applicable to the blank filler module.)
The CLSB-R5 is used for the R3-CT4C and R3-CT8C.
The CLSE is used for the R3-WTU.
[2] COMMUNICATION MODE
S: Single
● R3-PA2
W: Dual (Select the /W code when a Network Module is
used.)
The R3-PA2 can handle a data range of -1 000 000 000 to 1
000 000 000 to represent encoder’s positions, while the
73VR3100 can handle only from 0 to 1 000 000 000.
Be sure that the input to the R3-PA2 remains within this
range.
● I/O MODULE WITH CONNECTOR TERMINAL
R3Y–[1][2]
The R3-PA2’s alarm output cannot be triggered from the
73VR3100.
[1] MODEL
Analog Input(FCN connector)
● R3-DAC16A
SS8: DC current input, 8 ch.
Mode setting is aveilable only for continuous output mode.
SS8N: DC current input, 8 ch., non-isolated
SV8: DC voltage input, 8 ch.
SV8N: DC voltage input, 8 ch., non-isolated
SV16N: DC voltage input, 16 ch., non-isolated
RS8: RTD input, 8 ch.
MS8: Potentiometer input, 8 ch.
Pulse Input(FCN connector)
PA16: Totalized pulse input, 16 ch.
Discrete Input(FCN connector)
DA16: Optical isolation discrete input, 16 ch. (13 V DC)
Discrete Output(FCN connector)
DC16: Realy output 16 ch. (Limited to two discrete output
modules at the maximum.)
[2] COMMUNICATION MODE
S: Single
W: Dual (Select the /W code when a Network Module is
used.)
● R3-CTxA, R3-CTxB, R3-WT4x, R3-WTU
In order to use models R3-CTxA, R3-CTxB, R3-WT4x and R3-
WTU, the data range must be set up with the R3
Configurator Software (model: R3CON). This change of
setting may lower the resolution of recorded data for certain
input ranges.
The R3CON Configurator Software is available for
downloading at M-System’s web site. A special cable is
required to connect the R3 modules to a PC.
The Clamp-on Current Sensors, NOT included in the product
package of the R3 modules, must be purchased separately.
Please refer to data sheet for the respective models (CLSA
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 3/14
http://www.m-system.co.jp/
MODEL: 73VR3100
[1] MODEL
■ STORING RATE
NC1: CC-Link (Ver. 1; 16-point analog)
NC2: CC-Link (Ver. 1; 32-point analog)
NC3: CC-Link (Ver. 2)
Possible storing rates depend upon the I/O module types.
STORING RATE
TYPE
20ms
Y
0.1s
Y
≥ 0.5s
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
R3-SS4
ND1: DeviceNet (16-point analog)
ND2: DeviceNet (32-point analog)
ND3: DeviceNet (64-point analog)
NE1: Ethernet (Modbus/TCP)
NF1: T-Link (Fuji Electric)
R3(Y)-SS8
R3(Y)-SS8N
R3-SS16N
R3-SV4
---
---
---
Y
Y
Y
Y
Y
R3-SV4A
R3-SV4B
R3-SV4C
R3(Y)-SV8
R3-SV8A
R3-SV8B
R3-SV8C
R3(Y)-SV8N
R3-SV16N
R3Y-SV16
R3-TS4
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
NM1: Modbus
---
---
---
---
Y
---
---
---
---
---
---
---
Y
NP1: PROFIBUS-DP
NL1: LonWorks (16-point analog)
POWER INPUT
Y
Y
N: No power supply
---
---
---
---
---
Y
R3-TS8
R3-RS4
● CAUTIONS OF USING THE R3 SERIES NETWORK MODULE
One R3 Series network module is mountable at the position
of I/O Module 4. In the dual communication mode, the
73VR3100 is automatically defined as ‘main’ bus, while the
R3 network is as ‘sub.’ The R3 network module cannot
output through output modules. Choose I/O modules with
dual communication mode (code ‘W’).
R3(Y)-RS8
R3-US4
R3-DS4
R3-DS4A
R3-DS8N
R3-CT4
R3-CT4A
R3-CT4B
R3-CT4C
R3-CT8A
R3-CT8B
R3-CT8C
R3-PT4
Y
Y
Y
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
Y
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
Y
■ SELECTABLE INTERFACE I/O MODULE (GATEWAY
MODULE)
R3 Series interface I/O modules as listed below are usable
for the 73VR3100.
R3-PA2
R3-PA4
R3-PA4A
R3-PA4B
R3-PA8
R3(Y)-PA16
R3-WTU
R3-WT4
R3-WT4A
R3-WT4B
R3-MS4
R3-[1]S
[1] MODEL
GC1: CC-Link (Ver.1.10/Ver.2.00)
GD1: DeviceNet (for 64-point analog signals)
GE1: Modbus/TCP (Ethernet)
GM1: Modbus (RS-485)
R3(Y)-MS8
R3-LC2
R3-CZ4
---
---
---
Y
Y
Y
Y
Y
GFL1: FL-net (Ver. 2.0; OPCN-2)
R3-AS4
R3-AS8
R3-AV4
R3-AV8
R3-AD4
R3-AT4
R3-AR4
---
Y
Y
Y
COMMUNICATION MODE
S: Single
---
---
---
---
Y
---
---
---
Y
---
---
---
Y
---
---
---
■ CAUTIONS OF USING THE R3 SERIES INTERFACE I/O
MODULE
R3(Y)-DA16
R3(Y)-DC16
R3-DC32A
R3-DAC16A
•Interface I/O Modules support analog data only, not for
digital data.
[Legend] Y = Selectable, --- = Not Selectable
•73VR3100 cannot output analog data. Only analog data
input via Interface I/O Module is available.
•73VR3100 can receive maximum 64 words for input data.
•Storing Interval 20 msec. is not supported. When
73VR3100 is in Remote Mode, storing Interval 20 msec. and
100 msec. are not supported.
■ SELECTABLE NETWORK MODULES
R3 Series network modules as listed to below are usable for
the 73VR3100.
R3–[1]–N
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 4/14
http://www.m-system.co.jp/
MODEL: 73VR3100
Weight: 2.3 kg (5.1 lb) except I/O modules
GENERAL SPECIFICATIONS
Construction: Panel mount type or desktop type
Degree of protection: IP65; applicable to the front panel of
the recorder with single mounting according to the specified
panel cutout (/HA: Desktop type cannot be mounted on a
panel surface)
Caution: Use of UPS (switching time: without delay, output:
sine waveforms) is recommended to prevent data loss or CF
card damage by a loss of power during recording.
PERFORMANCE
Calendar clock accuracy: Monthly deviation 3 minutes at
■ CONNECTION
Power input: Euro type connector terminal
25°C
Applicable wire size: 0.2 – 2.5 mm or AWG 24 – 12 for both
2
Insulation resistance: ≥ 100 MΩ with 500 V DC (power to
Ethernet to FG)
stranded and solid wires. stripped length 7 mm. Use pin
terminals with stranded wires.
Refer to respective data sheet of R3 Series for I/O
insulation.
Ethernet: RJ-45 Modular Jack
■ MATERIALS
Dielectric strength
Enclosure: Steel
AC power: 2000 V AC @1 minute (power to Ethernet or FG)
500 V AC @1 minute (Ethernet to FG)
DC power: 1250 V AC @1 minute (power to Ethernet or FG)
500 V AC @1 minute (Ethernet to FG)
Refer to respective data sheet of R3 Series for I/O and I/O-to
-FG strength.
Bezel: Flame-resistant resin (black)
Front filter: Transparent resin
■ INTERFACE
Ethernet: 10BASE-T / 100BASE-TX automatically switched;
Conforms to IEEE 802 (10BASE-T) or IEEE 802.3 (100BASE-
TX)
IP address: 192.168.0.1 (factory default setting)
Subnet mask: 255.255.255.0 (factory default setting)
Default gateway: None (factory default setting)
CF Card slot: Type I; for use with the cards’ operating
voltage 3.3 V
USB: Conforms to Version 1.1
■ DISPLAY
Display device: 5.5-inch TFT LCD
Display colors: 256
Resolution: 320 × 240 pixels
Pixel pitch: 0.12 × 0.35 mm
Note: The backlight can be replaced in M-System factory.
The LCD must be replaced at the same time.
INSTALLATION
Power consumption
•AC:
Approx. 36 VA at 100 V
Approx. 46 VA at 240 V
•DC: Approx. 24 W, approx 1.0 A
Operating temperature: 0 to 50°C (32 to 122°F)
Display quality (e.g. decreased contrast) may deteriorate
when the recorder is used for a long time in an environment
exceeding 50°C. However, it is only a temporary
phenomenon. When the recorder is back in normal
temperature, full legibility is recovered. No damage in
performance.
Operating humidity: 30 to 85 %RH (non-condensing)
Allowable dust particles: 0.1 mg/m
2
(no conductive particles)
Corrosive gas: Not allowed
Mounting: Panel flush mounting (except desktop type)
Panel cutout dimensions: 137 × 137 mm (5.39”× 5.39”)
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 5/14
http://www.m-system.co.jp/
MODEL: 73VR3100
APPLICATION SOFTWARE CD
■ 73VRPAC2 (included in the product package)
• 73VR3100 Builder Software: Model 73VR31BLD
Used to configure parameters on the PC.
- Parameter configurations can be downloaded to the recorder via Ethernet.
- Present setting on the 73VR3100 can be uploaded and displayed on the PC.
- Configuration files can be converted into CSV.
• 73VR Data Viewer: Model 73VRWV
Used to show and analyze recorded data on the PC.
- Data stored in the CF Card can be called up on the PC screen via the CF Card Reader.
- Data stored in the CF Card can be sent by FTP and called up on the PC screen.
- Various analyzing functions
- Data and alarm history files can be converted into CSV.
• PC Recorder Software: Model MSR128-V6
- The 73VR3100 data can be sampled and stored in real time via Ethernet by the MSR128-V6.
- Data stored in the CF Card can be sent via Ethernet and called up on the PC screen.
- Data stored in the CF Card can be called up on the PC screen via the CF Card Reader.
• Instruction Manuals
- 73VR3100 users manual
- 73VR31BLD users manual
- 73VRWV users manual
- MSR128-V6 users manual
- 73VR3100 REMOTE MODE Reference Manual
PC REQUIREMENTS (provided by the user)
■ 73VR3100 Builder Software: Model 73VR31BLD
Operating system
Windows 7 Professional (32-bit) or Windows 10 (32-bit, 64-bit)
Note: Proper software functions may not be ensured under certain conditions.
1024 by 768 pixels or better resolution
Screen area
CD drive
Windows supported CD drive is used to install the software program.
Used to read/write the CF Card
Card reader
Mouse
Windows supported
LAN card
LAN card required to connect to Ethernet; 10BASE-T or 100BASE-T cable
■ 73VR Data Viewer: Model 73VRWV
Operating system
Windows 7 Professional (32-bit) or Windows 10 (32-bit, 64-bit)
Note: Proper software functions may not be ensured under certain conditions.
1024 by 768 pixels or higher
Screen area
Display color
65000 colors (16-bit)
Main memory (RAM) 2 GB recommended
CD drive
Card reader
Mouse
Windows supported CD drive is used to install the software program.
Used to read/write the CF Card
Windows supported (Certain functions of the 73VR may be compromised if the mouse’s software driver is
not Windows standard.)
LAN card
LAN card required to connect to Ethernet; 10BASE-T or 100BASE-T cable
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 6/14
http://www.m-system.co.jp/
MODEL: 73VR3100
■ PC Recorder Software: Model MSR128-V6
NORMAL MODE (storing rates ≥ 500 ms)
IBM PC/AT or compatible
HIGH SPEED MODE (storing rates 100 / 200 ms)*1
PC
Operating system
Windows XP SP1, SP2, SP3, Windows Vista Business (32-bit), Windows 7 Professional (32-bit) or
Windows 10 (32-bit, 64-bit)
Note: Proper software functions may not be ensured under certain conditions.
CPU
Pentium III 800 MHz or higher
1 GHz higher for Windows Vista, Windows 7,
Windows 10
Pentium IV 2.0 GHz or higher
Screen area
Display color
Video memory
Main memory
1024 by 768 pixels or better resolution
65000 colors (16-bit)
2 MB minimum; 4 MB recommended
4 MB minimum
256 MB recommended for Windows XP
512 MB recommended for Windows XP
1 GB recommended for Windows Vista, Windows 7, 1 GB recommended for Windows Vista, Windows 7,
Windows 10
Use an internal hard disk.*2
Windows 10
Use an internal hard disk.*2
Hard disk area
Printer
Max. approx. 100 MB required per day.
Max. approx. 500 MB required per day.
Use a printer for Windows. The programs use Standard System Fonts used in Windows.
Use a printer driver for Standard System Fonts.
Windows supported CD drive is used to install the software program.
CD drive
Card reader drive
Used with devices which save data in a CF Card
RS-232-C port (COM1 through COM5) supported LAN card by Windows
LAN card
Communication port
*1. The 73VR1100 or the 73VR21x cannot be used in High Speed Mode.
*2. External (e.g. SCSI) devices may impair appropriate performance.
EXTERNAL VIEW
■ FRONT VIEW
(1) Touch Panel Screen
(2) Front Cover
(3) CF Card Slot
(7) USB Connector
(4) Eject Button
(6) CF Card Access Indicator LED
(5) Reset Button
■ REAR VIEW
• With I/O Modules
(8) PC Configurator Port
(9) LAN Port
•†Without I/O Modules
• I/O Module Assignment
(7) USB Connector
(
10) I/O Data Allocation
DIP SW
8
7
6
5
4
3
2
1
ON
(11) Power LED
(12) Power Input Terminal Block
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 7/14
http://www.m-system.co.jp/
MODEL: 73VR3100
CONNECTION DIAGRAM
Ethernet
10BASE-T / 100BASE-TX
RJ-45 MODULAR JACK
U (+)
V (–)
POWER
FG
USB
CONFIGURATOR PORT
USB
EXTERNAL DIMENSIONS unit: mm (inch)
· Panel mount type
135.5 (5.33)
151.5 (5.96)
144 (5.67)
245.1 (9.65)
2 – 26 (.08 –1.02)
(panel thickness)
29.5
(1.16)
Attach the mounting bracket either on the top/bottom or on the sides.
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 8/14
http://www.m-system.co.jp/
MODEL: 73VR3100
· Desktop type
135.5 (5.33)
144 (5.67)
245.1 (9.65)
29.5
(1.16)
The handle and rubber feet cannot be detached from desktop type unit.
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 9/14
http://www.m-system.co.jp/
MODEL: 73VR3100
PANEL CUTOUT (unit: mm)
Usable panel thickness: 2 – 26 mm (0.08” – 1.02”)
■ SINGLE MOUNTING
■ VERTICAL CLUSTERED MOUNTING (max. 3 units)
137+2
137+2
0
0
L+2 (mm)
Number
0
2
3
282
426
4
570
175 min
5
714
6
858
■ HORIZONTAL CLUSTERED MOUNTING
7
1002
8
1146
9
1290
10
n
1434
(114 × n) – 6
Notes
1. The R3 I/O modules mounted on the second and the third 73VR3100
from the top cannot be removed in the vertical clustered mounting.
2. Dimensional tolerance 3ꢀ unless otherꢁise specified.
( 0.3 mm for ꢂ 10 mm)
3. Desktop type cannot be mounted on a panel surface.
L +2
0
trigger signal, and stores preset number of samples (max.
1200 respectively) before and after the moment of event.
Remote trigger: Data is automatically recorded while the
external trigger condition (input) is true.
■ STORING RATE
SOFTWARE FUNCTIONS
■ STORING RATE v.s. NUMBER OF INPUT CHANNELS
20 millisec.: 8 analog inputs and 8 discrete inputs
0.1 seconds: Total of 16 analog and/or discrete inputs
0.5 seconds or longer: Total of 64 analog and/or discrete
inputs
20 millisec., 0.1, 0.5, 1, 2, 5, 10 seconds, 1, 10 minutes
■ DATA STORAGE
■ INPUT SIGNALS
• CF card
Analog: DC voltage/current, thermocouple, RTD, AC
voltage/current or pulse
Data file: Stores momentary values in the storing rate and
their calculation result.
Discrete: Contact signals
Alarm history file: Records time index information when
alarms are triggered and reset.
■ DATA STORING METHOD
Normal: Recording is manually initiated and stopped. Data
is continuously stored while the recording is on.
Auto: Recording is automatically initiated and stopped at a
predefined time.
Comment history file: Records comments written in trend
views with time index. Oldest data is overwritten with new
data when the number of records reaches 1000 files.
Configuration file: Stores the 73VR3100 setting.
Event recording: The recorder detects an external event by
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 10/14
http://www.m-system.co.jp/
MODEL: 73VR3100
File format: Binary
Chart speed: pixel(s)/samples
Oldest measured data and alarm history data are
overwritten with new data when the card memory is full.
• USB memory
4 (Not selectable with the storing rate 20 millisec.), 1, 1/5,
1/32, 1/160 (Not selectable with the storing rates 20 msec.
and 0.1 sec.), 1/480 (Not selectable with the storing rates
20 msec. and 0.1 sec.) or 1/960 (Not selectable with the
storing rates 20 msec. and 0.1 sec.)
(Chart speed is described as number of pixels to plot single
data sample.)
Indicated interval data (except alarm history and comment
history) stored in USB memory as CSV file is operable (even
during storing)
■ ALARM (Available with 0.5 sec. or longer storing rates)
• Analog Alarm
Display rate: 1 sec.
Pen thickness: Normal and wide
Alarm setpoints: Max. 4 points per channel
Alarm type: High / Low
Digital indicator: Shows momentary value.
Alarm indicator: Shows alarm status of the channels
displayed on the screen.
Deadband: Set in engineering unit values
Output: At the R3-DC16, R3-DC32A and R3-DAC16A
• Discrete Alarm
Comment: Shows comments entered manually.
Scale: Linear and square root;
Alarm type: Either ON or OFF status can be set as alarm.
Delay time: Alarm trips after a specified time delay.
Output: At the R3-DC16, R3-DC32A and R3-DAC16A
• Alarm Data Storage
Switchable to the engineering unit scale.
Scroll and stop trend view is available (only in Chart speed:
4 or 1)
• Bargraph View
Stored information: Date/time of alarm events (trip and
reset), Pen No., Tag Name and Alarm Message
Number of stored alarm events: Depends upon the CF Card
capacity.
Bargraph direction: Perpendicular or horizontal
Number of pens displayed: 2, 4, 6, 8 per view
Number of display views: 4
Display rate: 1 sec.
128 MB 250 events
Digital indicator: Shows momentary value.
Alarm indicator: Shows alarm status of the channels
displayed on the screen.
256 MB 500 events
512 MB or 1 GB 1000 events
Scale: Linear and square root; Switchable to the engineering
unit scale.
■ CALCULATION FUNCTIONS
Number of channels
20 msec. or 0.1 sec. storing rates: 16 channels
0.5 sec. or longer storing rates: 64 channels
Operations
• Overview
Number of pens displayed: 2, 4, 6, 8, 16 per view
Number of display views: 64
Arithmetic: Addition/subtraction, Multiplication, Division
Logical: AND, OR, NOT, XOR
Display rate: 1 sec.
Alarm indicator: Shows alarm status and date/time of the
last alarm trip and reset for the channels displayed on the
screen.
Mathematical: Square root extractor, Power
Accumulation: Analog accumulation, Pulse accumulation
(per time unit)
Filter: Moving average, First order lag
Hold: Peak (maximum) hold (tracking increasing signal),
Peak (minimum) hold (tracking decreasing signal)
F value: F value
• Retrieve View: Shows data stored in the CF Card.
Number of pens displayed: 2, 4, 6, 8 per view
Number of display views: 4
Data search: Scrolling the chart, specifying a specific time
index, or searching by max./min. values.
Anemoscope: 16 directions
Alarm
Data readout: Reading data pointed by the cursor on the
screen and showing the readout value.
Alarm trip can be programmed for calculated results.
■ DATA DISPLAY FUNCTIONS
• Alarm History View: Shows data stored in the alarm
history file.
From Ver.6.03.09,Overview, Trend and Bargraph views are
updated even while "stop" operation status.
• Trend View
Number of displayed alarm events: 16
Number of display views: 1
Chart direction: Perpendicular or horizontal
Number of pens displayed: 2, 4, 6, 8 per view
Number of display views: 4
Display items: Date/time of alarm events (trip and reset),
Pen No., Tag Name and Alarm Message
Display update: Automatically updated by a new event
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 11/14
http://www.m-system.co.jp/
MODEL: 73VR3100
Supported Function Codes
CODE NAME
Data search: Scrolling the view or specifying a specific time
index.
FUNCTION
Reads DO
01
02
04
05
11
Read Coil Status
Jump: Scroll the view to an alarm event to show the relevant
data on Retrieve View.
Read Input Status
Read Input Register
Force Single Coil
Reads DI
Reads Input Register
Sets DO
• Comment History View: Shows data stored in the
comment history file.
Fetch Communication
Event Counter
Reads Status Word and
Event Counter from
Comm. Event Counter
Number of displayed alarm events: 16
Number of display views: 1
15
Force Multiple Coils
Sets DO (multiple)
Data search: Scrolling the view or specifying a specific time
index.
Exception Response
CODE NAME
FUNCTION
Jump: Scroll the view to a comment to show the relevant
data on Retrieve View.
01
02
Illegal Function
Function Not supported
Illegal Data Address
Speci!ed address does
not exist
■ ETHERNET COMMUNICATION
Monitoring data and setup of the 73VR3100 is possible on
the PC connected via Ethernet.
Supported Function Codes
ADDR. NAME
• Dedicated Protocol
Real time communication: Transmits specific data to a host
PC installed with the PC Recorder Software (model:
MSR128).
Coil (0X)
1...256 Alarm output, discrete output
1...256 Trigger input, discrete input
257...319 Function data (discrete)
Input Status
(1X)
FTP communication: Transmits data stored in the CF Card
using the FTP protocol to a host PC by the 73VR Data Viewer
(model: 73VRWV) installed in it. Data can be transmitted
even during recording.
Input Register
(3X)
1...64
257...
385...
Measured data (analog, 2 bytes)
Measured data (analog, 4 bytes)
Function data (analog, 4 bytes)
Download, Upload: Software configurations created on the
73VR3100 Configuration Builder (model: 73VR31BLD) can
be downloaded to the 73VR3100. The configuration set up
on the 73VR3100 can be uploaded and displayed on the
73VR31BLD.
■ REMOTE MODE
Setting and operation from PLC is available in combination
with interface I/O modules.
Please refer to the 73VR3100 REMOTE MODE Reference
Manual for detailed information.
• Modbus Protocol
Protocol: Modbus/TCP
■ OTHER FUNCTIONS
Port No.: 502 (fixed)
• Operation Lockout
IP address: Set on the recorder
With a password setting, unauthorized operations on the
Trend View, Bargraph View and Overview can be locked out.
• Data File Used Volume Information
A bargraph with % indication is provided on the screen to
show how much percent of the data file memory has been
used up.
Subnet mask: Set on the recorder
Default gateway: Set on the recorder
Max. number of 73VR3100 connected simultaneously: 2
0 – 49 % used: Green bargraph
50 – 79 % used: Amber bargraph
80 – 100 % used: Red bargraph
• Hot Swapping of the CF Card
The CF Card is hot swappable: removable during data
recording. However, there may be a slight disturbance in
storing rate when the card is inserted.
• Screen Saver
The backlight is automatically turned off if the screen is
untouched for a certain time period.
• Bus Error Alert
An alarm contact is output at a specified channel of the R3-
DC16, R3-DC32A and R3-DAC16A in case of internal bus
error. (Only 1 channel can be specified.)
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 12/14
http://www.m-system.co.jp/
MODEL: 73VR3100
• Writing/Reading Setting
The recorder’s present setting can be stored in a USB flash-
memory. Setting stored in the memory can be read in to the
73VR3100.
• Trend View Storing Data
Display trend view data storable in CF card even while
"stop" operating status (only in Chart speed: 4 or 1)
■ STORABLE TIME DURATION IN 1GB CF CARD
STORING
RATE
APPROXIMATE TIME DURATION
16 ch input
approx. 3 days
4 ch input
approx. 9 days
approx. 46 days
8 ch input
approx. 5 days, 8 hours
32 ch input
64 ch input
---
---
20 millisec.
0.1 seconds
0.5 seconds
1 second
10 seconds
1 minute
---
---
approx. 27 days, 16 hours approx. 15 days 8 hours
approx. 231 days
approx. 1 year, 97 days
10 years minimum
10 years minimum
approx. 138 days
approx. 277 days
approx. 77 days
approx. 154 days
40 days
81 days, 16 hours
20 days, 16 hours
approx. 42 days
approx. 7 years, 222 days approx. 4 years, 83 days approx. 2 years, 86 days approx. 1 year 55 days
10 years minimum 10 years minimum 10 years minimum approx. 6 years 335 days
--- : Not Applicable
Note 1: Data are calculated ones, and thus not guaranteed.
Note 2: Assuming 4 bytes per data per channel.
Note 3: A year is calculated as 365 days.
SYSTEM CONFIGURATION EXAMPLES
■ INDEPENDENTLY USED
Paperless Recorder
(models: 73VR3100)
■ INTERFACING WITH A PC
• Reading Data from CF Card
• Ethernet Connection
Data Viewer
(model: 73VRWV)
PC Recorder Software
(model: MSR128)
CF Card
Ethernet
Card Reader
Switch / Hub
Ethernet
Paperless Recorder
(models: 73VR3100)
Paperless Recorder
(models: 73VR3100)
Note: It is recommended to connect the 73VR3100 to the PC using
straight cables via a switch/hub on the Ethernet.
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 13/14
http://www.m-system.co.jp/
MODEL: 73VR3100
■ INTERFACING WITH A PLC/DCS USING A NETWORK MODULE
PC
PC Recorder Software
(model: MSR128)
PLC, DCS
Ethernet
Open Field Network
Switch / Hub
Ethernet
Paperless Recorder
(models: 73VR3100)
Specifications are subject to change without notice.
73VR3100 SPECIFICATIONS
ES-7397 Rev.30 Page 14/14
http://www.m-system.co.jp/
相关型号:
©2020 ICPDF网 联系我们和版权申明