FLC-0A-K/Q [MSYSTEM]

Space-saving Plug-in Signal Conditioners F-UNIT;
FLC-0A-K/Q
型号: FLC-0A-K/Q
厂家: M-SYSTEM    M-SYSTEM
描述:

Space-saving Plug-in Signal Conditioners F-UNIT

文件: 总3页 (文件大小:103K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: FLC  
0: Specify (strain gauge and excitation)  
Space-saving Plug-in Signal Conditioners F-UNIT  
[2] OUTPUT  
Current  
STRAIN GAUGE TRANSMITTER  
(non-isolated)  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
Functions & Features  
• Providing a DC output signal proportional to a bridge type  
strain gauge utilized in load cells, pressure transducers  
• Supplying required excitation voltage  
• Drives bridges of various ratings  
• Excitation adjustable from 2 V to 10 V  
• Wide-range adjustment: 0 – 80 % for zero, 20 – 100 % for  
span  
• High-density mounting  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
Typical Applications  
• Weighing system for tanks, hoppers, silos  
• Weighing system using cranes  
• Float level meter utilizing strain gauges  
26 (1.02)  
[3] POWER INPUT  
AC Power  
100  
(3.94)  
K: 85 – 132 V AC  
(Operational voltage range 85 – 132 V, 47 – 66 Hz)  
L: 170 – 264 V AC  
137  
(5.39)  
mm (inch)  
(Operational voltage range 170 – 264 V, 47 – 66 Hz)  
DC Power  
R: 24 V DC  
MODEL: FLC–[1][2]–[3][4]  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
P: 110 V DC  
ORDERING INFORMATION  
• Code number: FLC-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. FLC-2A-K/Q)  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
[4] OPTIONS  
blank: none  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
/Q: With options (specify the specification)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
[1] INPUT STRAIN GAUGE  
1: 1 mV/V  
/C02: Polyurethane coating  
12: 1.25 mV/V  
15: 1.5 mV/V  
2: 2 mV/V  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
3: 3 mV/V  
4: 4 mV/V  
5: 5 mV/V  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
6: 10 mV/V  
7: 20 mV/V  
Connection: M3.5 screw terminals (torque 0.8 N·m)  
FLC SPECIFICATIONS  
ES-1435 Rev.6 Page 1/3  
http://www.m-system.co.jp/  
MODEL: FLC  
Screw terminal: Nickel-plated steel (standard) or stainless  
steel  
500 V AC @ 1 minute (I/O to power)  
Power input code K, L, P:  
Housing material: Flame-resistant resin (black)  
Isolation: Input or output to power  
2000 V AC @ 1 minute (input or output or power to ground)  
1500 V AC @ 1 minute (I/O to power)  
Overrange output: Approx. -10 to +120 % at 1 – 5 V  
Excitation adjustment: 2 – 10 V (front)  
Zero adjustments (tare): 0 – 80 % (front)  
(Excitation voltage: factory default)  
Span adjustment: 100 – 20 % (front)  
(Excitation voltage: factory default)  
INPUT SPECIFICATIONS  
Input: Bridge voltage from load cells  
Strain Gauge  
Rated output from strain gauge: 1 – 20 mV/V;  
Input to the transmitter must be over 3 mV.  
Excitation: 2 – 10 V adjustable (5 V standard)  
Maximum current: 35 mA  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
Load resistance: Output drive 15 V max.  
DC Voltage: -10 – +12 V DC  
Minimum span: 5 mV  
Offset: Max. 1.5 times span  
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V  
INSTALLATION  
Power input  
AC: Approx. 5 VA  
DC: 24 V approx. 120 mA  
110 V approx. 40 mA  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail; Standard Rack Mounting  
Frame BX-16H available  
Weight: 200 g (0.44 lb)  
PERFORMANCE in percentage of span  
Accuracy: ±0.1 % (input ≥ 3 mV)  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) (input ≥ 3  
mV)  
Response time: ≤ 0.5 sec. (0 – 90 %)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength  
Power input code R:  
2000 V AC @ 1 minute (input or output or power to ground)  
FLC SPECIFICATIONS  
ES-1435 Rev.6 Page 2/3  
http://www.m-system.co.jp/  
MODEL: FLC  
EXTERNAL VIEW  
Excitation Adj.  
Zero Adj.  
Span Adj.  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
CLAMP  
(top & bottom)  
7.8 (.31)  
1
2
15  
(.59)  
DIN RAIL  
35mm wide  
3
4
2–4.5 (.18)  
HOLE  
15 (.59) deep  
5
6
8–M3.5  
SCREW  
7
8
26 (1.02)  
107 (4.21)  
137 (5.39)  
26 (1.02)  
[3.3 (.13)]  
•When mounting, no extra space is needed between units.  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Z
S
STRAIN  
GAUGE  
Low Drift  
Amplifier  
Output  
Driver  
+
+
1
2
3
4
5
6
7
8
+
OUTPUT  
U(+)  
V(–)  
Low Drift  
DC Volt.  
Stabilizer  
EXC.  
POWER  
*
*
Base Socket  
*Ground the shield cable at either strain gauge or transmitter side.  
Specifications are subject to change without notice.  
FLC SPECIFICATIONS  
ES-1435 Rev.6 Page 3/3  
http://www.m-system.co.jp/  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY