KSP-2G-F [MSYSTEM]

Plug-in Signal Conditioners K-UNIT;
KSP-2G-F
型号: KSP-2G-F
厂家: M-SYSTEM    M-SYSTEM
描述:

Plug-in Signal Conditioners K-UNIT

文件: 总3页 (文件大小:98K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: KSP  
4: 0 – 10 V DC (Load resistance 1000 Ω min.)  
Plug-in Signal Conditioners K-UNIT  
5: 0 – 5 V DC (Load resistance 500 Ω min.)  
6: 1 – 5 V DC (Load resistance 500 Ω min.)  
4W: -10 – +10 V DC (Load resistance 2000 Ω min.)  
5W: -5 – +5 V DC (Load resistance 1000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
LOW FREQUENCY TRANSMITTER  
(50 Hz minimum, for Mitsubishi inverter)  
Functions & Features  
• Converting the pulse output from FM terminal of  
Mitsubishi inverter into standard process signal  
• Isolation up to 2000 V AC  
[2] POWER INPUT  
AC Power  
• High-density mounting  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
Typical Applications  
• Positive displacement flowmeters, turbine flowmeters and  
vortex flowmeters  
• Proximity switches  
50  
(1.97)  
DC Power  
S: 12 V DC  
R: 24 V DC  
80  
(3.15)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
123  
(4.84)  
Connection: M3.5 screw terminals  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
Overrange output: 0 to 120 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
Input pulse sensing: DC coupled standard  
Input filter: CR filter incorporated  
mm (inch)  
MODEL: KSP-2[1]-[2]-ME  
ORDERING INFORMATION  
• Code number: KSP-2[1]-[2]-ME  
Specify a code from below for each of [1] and [2].  
(e.g. KSP-2A-B-ME)  
(C = 3.3 nF, R = 10 kΩ; parallel connection)  
Low-end cutout: 2 to 5 %  
• Frequency range (e.g. 0 – 1440 Hz)  
Applicable inverter:  
Mitsubishi electric FREQROL series: A024, A200,  
A500, A700, A800, D700, E500, E700, F400, F500, F700,  
F700PJ, F800, S500, U100, B, B3  
INPUT  
2: Voltage pulse  
Mitsubishi electric MELTRAC series: A100, A200,  
V200  
[1] OUTPUT  
Current  
Note) Do NOT connect other devices except the transmitter  
to the inverter's FM terminal. Do NOT bundle the FM and  
motor wirings.  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
INPUT SPECIFICATIONS  
Frequency range: 0 – 50 Hz through 0 - 1440 Hz  
Pulse width (time) requirement: ≥ 280 μsec. (Hi and Lo)  
Voltage Pulse  
Waveform: Square  
Input amplitude: V  
H
4 ±0.7 - 50 V, V 1 ± 0.7 V  
L
Input impedance: ≥ 7 kΩ (for 9 V DC pulse)  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 100 Ω min.)  
KSP SPECIFICATIONS  
ES-3572-ME Rev.3 Page 1/3  
http://www.m-system.co.jp/  
MODEL: KSP  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
Load resistance: Output drive 15 V max.  
DC Voltage: -10 – +12 V DC  
Minimum span: 5 mV  
Offset: Max. 1.5 times span  
Load resistance: Output drive 10 mA max.; 5 mA for  
negative voltage output; at ≥ 0.5 V  
INSTALLATION  
Power input  
AC: Operational voltage range: rating ±10 %,  
50/60 ± 2 Hz, approx. 2.5 VA  
DC: Operational voltage range: rating ±10 %,  
ripple 10% p-p max.; approx. 2.5 W (100 mA at 24 V)  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 350 g (0.77 lb)  
PERFORMANCE in percentage of span  
Accuracy: ± 0.3 % (output 10 – 100 %)  
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)  
Response time: (0 – 90 %)  
Approx. 2 sec. for 0 – 50 Hz  
Approx. 1 sec. for 0 – 100 Hz  
Approx. 0.5 sec. for 0 – 500 Hz  
Approx. 0.5 sec. for 0 – 10 kHz  
Ripple: 0.2 %p-p max. with input ≥ 10 %  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (input to output  
to power to ground)  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
CLAMP  
(top & bottom)  
7.8 (.31)  
DIN RAIL  
35mm wide  
6
5
4
3
2–  
4.5 (.18) dia.  
MTG HOLE  
15 (.59) deep  
7
8
1
2
8–  
M3.5  
SCREW  
50 (1.97)  
103 (4.06)  
123 (4.84)  
40 (1.57)  
50 (1.97)  
[3.3 (.13)]  
• When mounting, no extra space is needed between units.  
KSP SPECIFICATIONS  
ES-3572-ME Rev.3 Page 2/3  
http://www.m-system.co.jp/  
MODEL: KSP  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Z
S
Isolation  
10kΩ 3.3nF  
Waveform  
Shaper  
Output  
Driver  
+
3
4
5
6
1
2
7
8
+
One-Shot  
Integration  
INPUT  
OUTPUT  
POWER  
U(+)  
V(–)  
Base Socket  
Note: Do NOT connect other devices except the transmitter to the inverter’s FM terminal.  
Do NOT bundle the FM and motor wirings.  
Specifications are subject to change without notice.  
KSP SPECIFICATIONS  
ES-3572-ME Rev.3 Page 3/3  
http://www.m-system.co.jp/  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY