MODEL: L4AS  
Plug-in Signal Conditioners M-UNIT  
[4] POWER INPUT  
AC Power  
K: 85 – 132 V AC  
QUAD DC ALARM  
Functions & Features  
(Operational voltage range 85 – 132 V, 47 – 66 Hz)  
L: 170 – 264 V AC  
• Providing relay contact closures at preset DC input levels  
• 4 setpoints: Hi/Hi, Hi, Lo, Lo/Lo  
• Single turn screwdriver or dial setpoint adjustments  
• Enclosed relays  
(Operational voltage range 170 – 264 V, 47 – 66 Hz)  
DC Power  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
P: 110 V DC  
• Relays can be powered 110 V DC  
• Isolation up to 2000 V AC  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
• High-density mounting  
Typical Applications  
• Annunciator  
GENERAL SPECIFICATIONS  
Construction: Stand-alone; terminal access at the front  
Connection: M3.5 screw terminals (torque 0.8 N·m)  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
• Various alarm applications  
75  
(2.95)  
Setpoint adjustments: Single-turn screwdriver adjustments  
or dials (front); -15 – +115 % independently  
Hysteresis (deadband): Approx. 1 %  
75  
(2.95)  
Front LEDs: Red LED turns on when the coil is energized.  
1
2
50  
3
50  
50  
4
50  
0
100  
0
%
100  
0
%
100  
%
0
100  
INPUT SPECIFICATIONS  
DC Current: Input resistor incorporated  
%
112  
(4.41)  
mm (inch)  
OUTPUT SPECIFICATIONS  
Relay Contact: 100 V AC @ 1 A (cos ø = 1)  
120 V AC @ 1 A (cos ø = 1)  
MODEL: L4AS–[1][2][3]–[4]  
240 V AC @ 0.5 A (cos ø = 1)  
30 V DC @ 1 A (resistive load)  
ORDERING INFORMATION  
• Code number: L4AS-[1][2][3]-[4]  
Specify a code from below for each of [1] through [4].  
(e.g. L4AS-1A1-R)  
Maximum switching voltage: 380 V AC or 125 V DC  
Maximum switching power: 120 VA or 30 W  
Minimum load: 5 V DC @ 10 mA  
Mechanical life: 5 x 10 cycles  
7
For maximum relay life with inductive loads, external  
protection is recommended.  
[1] SETPOINT ADJUSTMENTS  
1: Single-turn screws  
2: Dials  
[2] INPUT  
Current  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
Voltage  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
[3] OUTPUT  
1: 4 points; coil energized with input > setpoint  
2: 2 points; coil energized with input < setpoint 2 points;  
coil energized with input > setpoint  
L4AS SPECIFICATIONS  
ES-1991 Rev.5 Page 1/4  
http://www.m-system.co.jp/  
MODEL: L4AS  
Dielectric strength: 2000 V AC @1 minute (input to output  
to power to ground)  
Alarm Trip Operation Terminal No. in parentheses  
• Output Code : 1  
Trip Operation in Power Failure:  
Terminals 3 5, 6 – 8, 11 – 13 and 14 – 16 turn ON.  
(3–4)ON  
Output 1  
(3–5)ON  
(6–7)ON  
Output 2  
(6–8)ON  
(11–12)ON  
Output 3  
(11–13)ON  
(14–15)ON  
Output 4  
(14–16)ON  
Input  
(%)  
0
50  
100  
No.1 No.2  
No.3 No.4  
• Output Code : 2  
Trip Operation in Power Failure:  
Terminals 3 5, 6 – 8, 11 – 13 and 14 – 16 turn ON.  
(3–4)ON  
Output 1  
(3–5)ON  
(6–7)ON  
Output 2  
Output 3  
Output 4  
(6–8)ON  
(11–12)ON  
(11–13)ON  
(14–15)ON  
(14–16)ON  
Input  
(%)  
0
50  
100  
No.1 No.2  
(LL) (L)  
No.3 No.4  
(H) (HH)  
INSTALLATION  
Power consumption  
AC: Approx. 4.5 VA  
DC: Approx. 2 W (80 mA at 24 V)  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 350 g (0.77 lb)  
PERFORMANCE in percentage of span  
Setpoint accuracy: ±0.3 %  
Temp. coefficient: ±0.05 %/°C (±0.03 %/°F)  
Response time: ≤ 0.5 sec. (0 – 100 % at 90 % setpoint)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
L4AS SPECIFICATIONS  
ES-1991 Rev.5 Page 2/4  
http://www.m-system.co.jp/  
MODEL: L4AS  
MOUNTING REQUIREMENTS  
M5 SCREWS  
M4 SCREWS  
60 (2.36)  
60 (2.36)  
60 (2.36)  
60 (2.36)  
2–M5  
2–M4  
75 (2.95) MIN.  
75 (2.95) MIN.  
EXTERNAL VIEW  
SCREWDRIVER ADJUSTMENTS  
DIAL ADJUSTMENTS  
Monitor LED  
Setpoint Adj.  
Monitor LED  
Setpoint Adj.  
1
2
3
4
1
2
3
4
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
2–5.8 (.23) dia. or  
2–4.8 (.18) dia.  
MTG HOLE  
16–M3.5  
SCREW  
8 (.31)  
8 (.31) deep  
DIN RAIL  
35mm wide  
TERMINAL  
COVER  
1
9
2
3
4
5
6
7 8  
10 11 12 13 14 15 16  
14*  
112 (4.41)  
[3.3 (.13)]  
75 (2.95)  
(.55)  
*Dial adj.  
• When mounting, no extra space is needed between units.  
L4AS SPECIFICATIONS  
ES-1991 Rev.5 Page 3/4  
http://www.m-system.co.jp/  
MODEL: L4AS  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
No.1 SET  
4
Low Drift  
Amplifier  
*
+
Ry  
Ry  
Ry  
Ry  
1
2
Comparator  
5
3
ALARM OUTPUT 1  
ALARM OUTPUT 2  
ALARM OUTPUT 3  
ALARM OUTPUT 4  
INPUT  
No.2 SET  
Comparator  
7
8
6
No.3 SET  
Comparator  
12  
13  
11  
15  
16  
14  
9
No.4 SET  
Comparator  
U(+)  
POWER  
V(–)  
10  
*Input shunt resistor incorporated for current input.  
Relay Protection  
•AC Powered  
•DC Powered  
Inductive  
Load (Coil)  
Inductive  
Load (Coil)  
Varistor or Spark  
Quenching Circuit  
Diode, Varistor or  
CR Circuit  
LOAD  
LOAD  
U
Specifications are subject to change without notice.  
L4AS SPECIFICATIONS  
ES-1991 Rev.5 Page 4/4  
http://www.m-system.co.jp/  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY