M2DYH2-24A-R/B [MSYSTEM]
Super-mini Signal Conditioners Mini-M Series;型号: | M2DYH2-24A-R/B |
厂家: | M-SYSTEM |
描述: | Super-mini Signal Conditioners Mini-M Series |
文件: | 总3页 (文件大小:105K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: M2DYH2
47 – 66 Hz)
DC Power
R: 24 V DC
Super-mini Signal Conditioners Mini-M Series
CURRENT LOOP SUPPLY
(applicable to HART signal, opencircuit detection selectable)
Functions & Features
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
R2: 11 – 27 V DC
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
P: 110 V DC
• Powers a 4 – 20 mA DC current loop
• Isolates and relays HART signals
• Shortcircuit protection
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
• Opencircuit detection selectable
• Applicable to smart transmitters
[2] OPTIONS (multiple selections)
Opencircuit detection
Typical Applications
blank: none
• 2-wire HART transmitters
/B: Opencircuit detector
23 (.91)
Standards & Approvals (must be specified)
/N: Without CE
/CE: CE marking
Model
76
(2.99)
Other Options
blank: none
/Q: Option other than the above (specify the specification)
ZERO
SPAN
124
(4.88)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
mm (inch)
/C02: Polyurethane coating
MODEL: M2DYH2–24A–[1][2]
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel
ORDERING INFORMATION
• Code number: M2DYH2-24A-[1][2]
Specify a code from below for each [1] and [2].
(e.g. M2DYH2-24A-M2/B/CE/Q)
GENERAL SPECIFICATIONS
Construction: Plug-in
• Specify the specification for option code /Q
(e.g. /C01/S01)
Connection: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Chromated steel (standard) or stainless
steel
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Overrange output: Approx. -10 to +110 %
Zero adjustment: -5 to +5 % (front)
Span adjustment: 95 to 105 % (front)
Opencircuit detection: Input current 0 mA when the output
loop is open.
SUPPLY OUTPUT
24: 24 V DC
INPUT
Current
4 – 20 mA DC (Input resistance approx. 250 Ω)
Photo MOS Relay ON Resistance; 3 Ω max.
OUTPUT
Current
SUPPLY OUTPUT
A: 4 – 20 mA DC (Load resistance 600 Ω max.)
225 - 600 Ω for HART communication
(across the terminals 1 – 5)
Output voltage: 24 – 28 V DC with no load
18 V DC min. at 20 mA
Current rating: ≤ 22 mA DC
• Shortcircuit Protection
[1] POWER INPUT
AC Power
Current limited: 30 mA max.
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
M2DYH2 SPECIFICATIONS
ES-5109 Rev.7 Page 1/3
http://www.m-system.co.jp/
MODEL: M2DYH2
Protected time duration: No limit
INPUT SPECIFICATIONS
■ DC Current: Input resistor incorporated
Input current: ≥ 0 mA
HART COMMUNICATION
Transmission gain: Approx. -3 dB (within 1 – 3 kHz)
measured with 250 Ω at output
Loop impedance: 250 Ω ±10 %
Communication directions: Bidirectional
INSTALLATION
Power Consumption
•AC:
Approx. 4 VA at 100 V
Approx. 6 VA at 200 V
Approx. 7 VA at 264 V
•DC: Approx. 3 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 150 g (0.33 lb)
PERFORMANCE in percentage of span
Accuracy: ±0.1 %
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Response time: ≤ 0.5 sec. (0 – 90 %)
Line voltage effect
Supply output: ±3 % over voltage range
Output signal: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II
Pollution Degree 2
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
RoHS Directive
EN 50581
M2DYH2 SPECIFICATIONS
ES-5109 Rev.7 Page 2/3
http://www.m-system.co.jp/
MODEL: M2DYH2
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
6 (.23)
DIN RAIL
35mm wide
4
1
5
8
2–4.2x5
(.17x.20)
MTG HOLE
6 (.24) deep
12
9
8–M3
SCREW
14 13
21.5 (.85) 10 (.39)
84 (3.31)
114 (4.49)
15 (.59)
[4 (.16)]
23 (.91)
• When mounting, no extra space is needed between units.
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
HART Isolation
Z
S
DC Isolation
2
*
4 – 20mA DC
Output
Driver
Opencircuit
Detector
+
–
+
+
–
1
1
4
5
8
9
*
RL
INPUT
250Ω
HHC
OUTPUT
12
2-WIRE XMTR
PWR SUPPLY
24V DC
Supply
13
14
U (+)
V (–)
HART Isolation
Base Socket
POWER
*1. Hand-held communicator
*2. Only for opencircuit detector (code /B)
■ When Used as DC Supply
■ When Used as Isolator
1
–
+
+
–
+
1
4
5
+
–
+
1
4
5
*
1
HHC INPUT
250Ω
250Ω
*
2-WIRE
XMTR
HHC
Specifications are subject to change without notice.
M2DYH2 SPECIFICATIONS
ES-5109 Rev.7 Page 3/3
http://www.m-system.co.jp/
相关型号:
©2020 ICPDF网 联系我们和版权申明