M3LT-R4/A [MSYSTEM]
Space-saving Signal Conditioners M3-UNIT Series;型号: | M3LT-R4/A |
厂家: | M-SYSTEM |
描述: | Space-saving Signal Conditioners M3-UNIT Series |
文件: | 总4页 (文件大小:139K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: M3LT
Space-saving Signal Conditioners M3-UNIT Series
POWER INPUT
DC Power
R4: 10 – 32 V DC
THERMOCOUPLE TRANSMITTER
(field- and PC-configurable)
(Operational voltage range 9 - 36 V, ripple 10 %p-p max.)
Functions & Features
• Accepts a thermocouple input and provides an isolated,
linearized DC signal
[1] CONFIGURATION OPTIONS
A: PC and field configurable
• Easy ‘One-Step Cal’ calibration using the front three
control buttons without needing a PC; PC software is also
usable.
B: Field configurable
[2] OPTIONS (multiple selections)
Standards & Approvals
• Both input and output type and range are configurable
• Front control button function can be locked
• Cold junction compensation
blank: CE marking
/UL: UL approval, CE marking
Other Options
• Linearization and burnout
blank: none
18 (.71)
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
106
(4.17)
/C02: Polyurethane coating
/C03: Rubber coating (UL not available)
110.5 (4.35)
mm (inch)
RELATED PRODUCTS
• PC configurator software (model: M3CFG)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
MODEL: M3LT–R4/[1][2]
ORDERING INFORMATION
• Code number: M3LT-R4/[1][2]
Specify a code from below for each of [1] and [2].
(e.g. M3LT-R4/A/UL/Q)
• Specify the specification for option code /Q
(e.g. /C01)
GENERAL SPECIFICATIONS
Construction: Small-sized front terminal structure
• Orders will be shipped at default factory settings (K, 0 –
1000°C input/4 – 20 mA output)
Connection: Euro type connector terminal
(applicable wire size: 0.2 to 2.5 mm , stripped length 8 mm)
2
Housing material: Flame-resistant resin (gray)
Isolation: Input to output to power
Overrange output: -15 to +115 %
Zero adjustment: -15 to +15 % (front)
Span adjustment: 85 to 115 % (front)
Burnout: Upscale (default), downscale or no burnout
selectable
INPUT – Field-selectable
Thermocouple
(PR), K (CA), E (CRC), J (IC), T (CC), B (RH), R, S, C (WRe 5-26),
N, U, L, P (Platinel II)
OUTPUT – Field-selectable
Current
Linearization: Standard
Cold junction compensation: CJC sensor attached to the
input terminals
0 – 20 mA DC
Voltage
Status indicator LED: Tri-color (green/amber/red) LED;
Blinking patterns indicate operation status of the
transmitter.
-2.5 – +2.5 V DC
-10 – +10 V DC
Configuration:
PC Configurator: (Model: M3LTCFG) via Windows PC
M3LT SPECIFICATIONS
ES-2661 Rev.13 Page 1/4
http://www.m-system.co.jp/
MODEL: M3LT
connected to th front jack.
INSTALLATION
Power consumption
•DC: Approx. 3 W
Programmable features include:
• I/O type and range
• Zero and span adjustments
Operating temperature: -25 to +65°C (-13 to +149°F)
Max. 55°C (131°F) for UL approval
Operating humidity: 0 to 95 %RH (non-condensing)
Mounting: DIN rail
• Burnout action
• User’s T/C table setting
(max. 300 points, input emf specified within
-100 – +1000 mV)
Weight: 100 g (0.22 lb)
• Others
(Refer to the instruction manual)
‘One-Step Cal’ calibration: With I/O type and the full-scale
range configured via the internal DIP switches, precise 0 %
and 100 % ranges are calibrated via the front control
buttons with a help of LED. Also I/O calibration and fine
adjustment are available with a PC.
Configurator connection: 2.5 dia. miniature jack;
RS-232-C level
PERFORMANCE
Accuracy: See Table 1 and refer to calculation examples of
overall accuracy.
Cold junction compensation error:
±0.5°C at 25 ±10°C
±0.9°F at 77 ±18°F
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) of max. span
at -5 to +55°C [23 to 131°F]
Response time: ≤ 0.9 sec. (0 – 90 %)
Burnout response: ≤ 10 sec.
INPUT SPECIFICATIONS
■ Thermocouple: See table 1
Input resistance: ≥ 1 MΩ
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(input to output or power to ground)
500 V AC @ 1 minute (output to power)
Burnout sensing: 130 nA ± 10 %
Temperature range: See Table 1.
OUTPUT SPECIFICATIONS
■ DC Current
CALCULATION EXAMPLES OF OVERALL ACCURACY
[Example 1]
Maximum range: 0 – 20 mA DC
Minimum span: 1 mA
Input: K thermocouple, 0 – 1000°C, Output: 4 – 20 mA DC
1) Absolute value accuracy (Table 1): 0.25°C
2) CJC error (0.5°C) added: 0.75°C
Conformance range: 0 – 24 mA DC
(Negative overrange current below 0 mA is not available.)
Offset: Lower range can be any specific value within the
output range provided that the minimum span is
maintained.
3) 0.75°C ÷ 1000°C × 100 = 0.075 %
4) 0.075 % < 0.1 % of span. ➠ 0.1 % is selected.
5) Output span 16 mA (= 20 mA – 4 mA)
Max. span 20 mA
Load resistance: Output drive 12 V maximum
■ DC Voltage
Output span ≥ 1/10 of max. span ➠ No need of adding
0.2 %.
Narrow Spans
Maximum range: -2.5 – +2.5 V DC
Minimum span: 250 mV
6) Overall accuracy equals ±0.1 % of span
[Example 2]
Conformance range: -3 – +3 V DC
Wide Spans
Input: K thermocouple, 50 – 150°C, Output: 2.0 – 2.5 V DC
1) Absolute value accuracy (Table 1): 0.25°C
2) CJC error (0.5°C) added: 0.75°C
Maximum range: -10 – +10 V DC
Minimum span: 1 V
3) 0.75°C ÷ (150 – 50)°C × 100 = 0.75 %
4) 0.75 %> 0.1 % of span. ➠ 0.75 % is selected.
5) Output span 0.5 V (= 2.5 V – 2.0 V)
Max. span 5 V
Conformance range: -11.5 – +11.5 V DC
Offset: Lower range can be any specific value within the
output range provided that the minimum span is
maintained.
Output span ≤ 1/10 of max. span ➠ Add 0.2 %.
6) Overall accuracy equals ±0.95 % of span (0.75 + 0.2)
Load resistance: Output drive 1 mA maximum
M3LT SPECIFICATIONS
ES-2661 Rev.13 Page 2/4
http://www.m-system.co.jp/
MODEL: M3LT
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
Approval:
UL/C-UL general safety requirements
(UL 61010-1, CAN/CSA-C22.2 No.1010-1)
EXTERNAL VIEW
■ FRONT VIEW
■ SIDE VIEW
LED1 (LD1)
10 11 12
LED2 (LD2)
Configuration DIP SW
7
8
9
LED3 (LD3)
MODE Button
UP Button
4 3 2 1
OFF
ON
DOWN Button
SW1
Configurator Jack
SW2
SW3
8 7 6 5 4 3 2 1
OFF
ON
4
5
6
4 3 2 1
OFF
ON
The DIP switch setting is required to select output types before setting a precise output range using the PC configurator
software.
For detailed information on the configuration and calibration, refer to the instruction manual.
INPUT TYPE, RANGE & ACCURACY
■ INPUT TYPE, RANGE & ACCURACY
Table 8
Thermocouple
°C
°F
MIN.
SPAN
MAXIMUM
RANGE
CONFORMANCE
RANGE
MIN.
SPAN
MAXIMUM
RANGE
CONFORMANCE
RANGE
ACCURACY*1
ACCURACY*1
(PR)
20
20
20
0 to 1760
0 to 1760
1ꢀ00
0ꢀ25
0ꢀ20
36
36
36
32 to 3200
32 to 3200
1ꢀ80
0ꢀ45
0ꢀ36
K (CA)
E (CRC)
-270 to +1370
-270 to +1000
-150 to +1370
-170 to +1000
-454 to +2498
-454 to +1832
-238 to +2498
-274 to +1832
J (IC)
20
20
20
-210 to +1200
-270 to +400
100 to 1820
-180 to +1200
-170 to +400
400 to 1760
0ꢀ25
0ꢀ25
0ꢀ75
36
36
36
-346 to +2192
-454 to +752
212 to 3308
-292 to +2192
-274 to +752
752 to 3200
0ꢀ45
0ꢀ45
1ꢀ35
T (CC)
B (RH)
R
20
20
20
-50 to +1760
-50 to +1760
0 to 2315
200 to 1760
0 to 1760
0 to 2315
0ꢀ50
0ꢀ50
0ꢀ80
36
36
36
-58 to +3200
-58 to +3200
32 to 4199
392 to 3200
32 to 3200
32 to 4199
0ꢀ90
0ꢀ90
1ꢀ44
S
C (WRe 5-26)
N
20
20
20
20
-270 to +1300
-200 to +600
-200 to +900
0 to 1395
-130 to +1300
-200 to +600
-200 to +900
0 to 1395
0ꢀ30
0ꢀ20
0ꢀ25
0ꢀ25
36
36
36
36
-454 to +2372
-328 to +1112
-328 to +1652
32 to 2543
-202 to +2372
-328 to +1112
-328 to +1652
32 to 2543
0ꢀ54
0ꢀ36
0ꢀ45
0ꢀ45
U
L
P(Platinel II)
*1ꢀ [Accuracy + Cold Junction Compensation Error 0ꢀ5°C (0ꢀ9°F)] or 0ꢀ1ꢁ oꢂ spanꢃ whichever is greaterꢀ
Iꢂ the selected output span equals to or narrower than the one-tenth oꢂ the maximum spanꢃ add 0ꢀ2ꢁꢀ
M3LT SPECIFICATIONS
ES-2661 Rev.13 Page 3/4
http://www.m-system.co.jp/
MODEL: M3LT
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
10 11 12
7
8
9
DIN RAIL
35mm wide
4
5
6
110.5 (4.35)
[5 (.20)]
CJC SENSOR
(model: CJM)
18 (.71)
• When mounting, no extra space is needed between units.
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
STATUS
CONTROL BUTTONS
ext. leadwire
T / C
DIP SW
10
7
Isolation
+
Output
Computation
Output
Driver
+
+
–
+
–
4
Low Drift
Amplifier
& Burnout
OUTPUT
POWER
–
8
–
*
5
6
11
12
9
CJC
SENSOR
CONFIGURATOR
JACK
* The CJC Sensor is secured to the terminal 6.
Loosen only the terminal 4 – 5 and connect the T/C extension wires.
Specifications are subject to change without notice.
M3LT SPECIFICATIONS
ES-2661 Rev.13 Page 4/4
http://www.m-system.co.jp/