M8BS-16K1-K/Q [MSYSTEM]

Dual Output Super-mini Signal Conditioners Pico-M Series;
M8BS-16K1-K/Q
型号: M8BS-16K1-K/Q
厂家: M-SYSTEM    M-SYSTEM
描述:

Dual Output Super-mini Signal Conditioners Pico-M Series

文件: 总14页 (文件大小:490K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: M8BS-16  
Dual Output Super-mini Signal Conditioners Pico-M Series  
[3] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
INSTALLATION BASE (16 positions)  
Functions & Features  
• Holding up to 16 modules of Pico-M series signal  
conditioners  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
Only solder side of the main PWB is coated.  
/C01: Silicone coating  
• Power supplied through printed wiring on the base  
• Saving wiring work within an instrumentational panel  
/C02: Polyurethane coating  
/C03: Rubber coating  
GENERAL SPECIFICATIONS  
Capacity: 16 positions  
Connection  
MODEL: M8BS-16[1]-[2][3]  
Power input: M3.5 screw terminals (M4 for power codes KK  
and L) (torque 0.8 N·m)  
ORDERING INFORMATION  
• Code number: M8BS-16[1]-[2][3]  
Specify a code from below for each of [1] through [3].  
(e.g. M8BS-16U1-KK/Q)  
Input and output: M3.5 screw terminals (torque 0.8 N·m)  
Screw terminal: Nickel-plated steel  
Isolation: Input to output 1 to output 2 to power to FG  
Power indicator LED: ON with normal voltage level  
• Specify the specification for option code /Q  
(e.g. /C01)  
INSTALLATION  
Power Consumption  
[1] CONNECTION (output 1/output 2)  
U0: Screw terminal block / Screw terminal block  
U1: Fujitsu FCN type connector / Screw terminal block  
U2: Fujitsu FCN type connector / Fujitsu FCN type connector  
U5: DDK connector / Screw terminal block  
K1: Azbil DCS J-HAM50/J-HMM00 module use  
/ Screw terminal block  
AC: 130 VA min.  
DC: 2.5 A min.  
Operating temperature: 0 to 55°C (32 to 131°F)  
0 to 50°C (32 to 122°F) for AC power  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface  
Weight  
K2: Azbil DCS J-AOM10 module use  
M8BS-16U0:  
/ Screw terminal block  
1.8 kg (4.0 lb) for power code K, L  
2.4 kg (5.3 lb) for power code KK  
1.5 kg (3.3 lb) for power code R  
M8BS-16U1, U5, K1, K2, Y1, Y2:  
1.6 kg (3.5 lb) for power code K, L  
2.2 kg (4.9 lb) for power code KK  
1.3 kg (2.9 lb) for power code R  
M8BS-16U2, K3:  
K3: Azbil DCS J-HAM50/J-HMM00 module use  
/ Azbil DCS J-HAM50/J-HMM00 module use  
Y1: Yokogawa DCS VMx/PM1 card use / Screw terminal block  
Y2: Yokogawa DCS MAC2/PAC card use / Screw terminal block  
[2] POWER SUPPLY UNIT  
AC Power  
1.4 kg (3.1 lb) for power code K, L  
2.0 kg (4.4 lb) for power code KK  
1.1 kg (2.4 lb) for power code R  
K: 85 – 132 V AC; single power source  
(Operational voltage range 85 – 132 V, 47 – 63 Hz)  
KK: 85 – 132 V AC; two independent power sources  
(Operational voltage range 85 – 132 V, 47 – 63 Hz)  
L: 170 – 264 V AC; single power source  
(Operational voltage range 170 – 264 V, 47 – 63 Hz)  
DC Power  
PERFORMANCE  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength:  
R: 24 V DC; no power supply unit  
1500 V AC @1 minute (input to output 1 or output 2 or  
power to FG)  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
Redundant power supplies are recommended for long time  
use without interruption.  
500 V AC @1 minute (output 1 to output 2 to power)  
500 V AC @1 minute (output 1 or output 2 to FG for AC  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 1/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
power input)  
MOUNTING REQUIREMENTS unit: mm (inch)  
465 (18.31)  
4–M5 SCREW  
CONNECTION DIAGRAM  
■ MODEL: M8BS-16U0 (screw terminal block / screw terminal block)  
■ CONNECTION DIAGRAM  
Power Supply Unit Code R, K  
Power Supply Unit Code KK, L  
+
+
+
+
A
B
C
D
A
OUTPUT 1  
OUTPUT 1  
B
Ch.1  
OUTPUT**  
OUTPUT 2  
Ch.1  
INPUT**  
Ch.1  
OUTPUT**  
OUTPUT 2  
Ch.1  
INPUT**  
C
D
A
+
+
+
+
A
B
C
D
OUTPUT 1  
OUTPUT 1  
B
Ch.16  
OUTPUT**  
OUTPUT 2  
Ch.16  
INPUT**  
Ch.16  
OUTPUT**  
OUTPUT 2  
Ch.16  
INPUT**  
C
D
1
2
3
3
4
5
3
4
5
U(+)  
FG  
U
POWER  
V(–)  
FG  
PWR1  
AC POWER  
AC POWER  
V
FG  
U
*
PWR2  
V
*
For power supply unit code KK only.  
** The input and output terminals are reversed for model M8YSx, M8YCx.  
Use either Output 1 or Output 2 terminal for the input.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 2/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
■ MODEL: M8BS-16U1 (Fujitsu FCN type connector, FCN-364P040-AU / screw terminal block)  
Connector Pin Assignment  
CN1: Output 1 or input  
PIN NO.  
A1  
ASSIGNMENT  
ch.1 +  
PIN NO.  
B1  
ASSIGNMENT  
ch.1 –  
A2  
ch.2 +  
B2  
ch.2 –  
A3  
ch.3 +  
B3  
ch.3 –  
A4  
ch.4 +  
B4  
ch.4 –  
A5  
ch.5 +  
B5  
ch.5 –  
A6  
ch.6 +  
B6  
ch.6 –  
A7  
ch.7 +  
B7  
ch.7 –  
A8  
ch.8 +  
B8  
ch.8 –  
A9  
ch.9 +  
B9  
ch.9 –  
A10  
A11  
A12  
A13  
A14  
A15  
A16  
ch.10 +  
ch.11 +  
ch.12 +  
ch.13 +  
ch.14 +  
ch.15 +  
ch.16 +  
B10  
B11  
B12  
B13  
B14  
B15  
B16  
ch.10 –  
ch.11 –  
ch.12 –  
ch.13 –  
ch.14 –  
ch.15 –  
ch.16 –  
A17 – A20, B17 – B20: Unused  
■ CONNECTION DIAGRAM  
Power Supply Unit Code R, K  
Power Supply Unit Code KK, L  
CN1  
A
CN1  
A
B
C
D
B
C
D
Ch.1  
OUTPUT**  
Ch.1  
INPUT**  
Ch.1  
OUTPUT**  
Ch.1  
INPUT**  
+
+
OUTPUT 2  
OUTPUT 2  
A
B
C
D
A
B
C
D
Ch.16  
OUTPUT**  
Ch.16  
INPUT**  
Ch.16  
OUTPUT**  
Ch.16  
INPUT**  
+
+
OUTPUT 2  
OUTPUT 2  
1
2
3
3
4
5
3
4
5
U(+)  
FG  
U
POWER  
V(–)  
FG  
PWR1  
AC POWER  
V
FG  
U
*
PWR2  
AC POWER  
V
*
For power supply unit code KK only.  
** The input and output terminals are reversed for model M8YSx, M8YCx.  
Use either Output 1 (connector) or Output 2 terminal for the input.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 3/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
■ MODEL: M8BS-16U2 (Fujitsu FCN type connector, FCN-364P040-AU / Fujitsu FCN type connector, FCN-364P040-AU)  
Connector Pin Assignment  
CN1: Output 1 or input  
CN2: Output 2 or input  
PIN NO.  
A1  
ASSIGNMENT  
ch.1 +  
PIN NO.  
B1  
ASSIGNMENT  
ch.1 –  
A2  
ch.2 +  
B2  
ch.2 –  
A3  
ch.3 +  
B3  
ch.3 –  
A4  
ch.4 +  
B4  
ch.4 –  
A5  
ch.5 +  
B5  
ch.5 –  
A6  
ch.6 +  
B6  
ch.6 –  
A7  
ch.7 +  
B7  
ch.7 –  
A8  
ch.8 +  
B8  
ch.8 –  
A9  
ch.9 +  
B9  
ch.9 –  
A10  
A11  
A12  
A13  
A14  
A15  
A16  
ch.10 +  
ch.11 +  
ch.12 +  
ch.13 +  
ch.14 +  
ch.15 +  
ch.16 +  
B10  
B11  
B12  
B13  
B14  
B15  
B16  
ch.10 –  
ch.11 –  
ch.12 –  
ch.13 –  
ch.14 –  
ch.15 –  
ch.16 –  
A17 – A20, B17 – B20: Unused  
■ CONNECTION DIAGRAM  
Power Supply Unit Code R, K  
Power Supply Unit Code KK, L  
CN1  
CN2  
A
CN1  
CN2  
A
B
C
D
B
C
D
Ch.1  
INPUT**  
Ch.1  
INPUT**  
A
B
C
D
A
B
C
D
Ch.16  
INPUT**  
Ch.16  
INPUT**  
1
2
3
3
4
5
3
4
5
U(+)  
FG  
U
POWER  
V(–)  
FG  
PWR1  
AC POWER  
V
FG  
U
*
PWR2  
AC POWER  
V
*
For power supply unit code KK only.  
** The input and output terminals are reversed for model M8YSx, M8YCx.  
Use either Output 1 or Output 2 connector for the input.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 4/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
■ MODEL: M8BS-16U5 (DDK connector, 17JE-13370-37 [D16B] / screw terminal block)  
Connector Pin Assignment  
CN1: Output 1 or input  
PIN NO.  
ASSIGNMENT  
ch.1 +  
PIN NO.  
20  
ASSIGNMENT  
ch.1 –  
1
2
ch.2 +  
21  
ch.2 –  
3
ch.3 +  
22  
ch.3 –  
4
ch.4 +  
23  
ch.4 –  
5
ch.5 +  
24  
ch.5 –  
6
ch.6 +  
25  
ch.6 –  
7
ch.7 +  
26  
ch.7 –  
8
ch.8 +  
27  
ch.8 –  
9
ch.9 +  
28  
ch.9 –  
10  
11  
12  
13  
14  
15  
16  
ch.10 +  
ch.11 +  
ch.12 +  
ch.13 +  
ch.14 +  
ch.15 +  
ch.16 +  
29  
ch.10 –  
ch.11 –  
ch.12 –  
ch.13 –  
ch.14 –  
ch.15 –  
ch.16 –  
30  
31  
32  
33  
34  
35  
17 – 19, 36, 37: Unused  
■ CONNECTION DIAGRAM  
Power Supply Unit Code R, K  
Power Supply Unit Code KK, L  
CN1  
A
CN1  
A
B
C
D
B
C
D
Ch.1  
OUTPUT**  
Ch.1  
INPUT**  
Ch.1  
OUTPUT**  
Ch.1  
INPUT**  
+
+
OUTPUT 2  
OUTPUT 2  
A
B
C
D
A
B
C
D
Ch.16  
OUTPUT**  
Ch.16  
INPUT**  
Ch.16  
OUTPUT**  
Ch.16  
INPUT**  
+
+
OUTPUT 2  
OUTPUT 2  
1
2
3
3
4
5
3
4
5
U(+)  
FG  
U
POWER  
V(–)  
FG  
PWR1  
AC POWER  
V
FG  
U
*
PWR2  
AC POWER  
V
*
For power supply unit code KK only.  
** The input and output terminals are reversed for model M8YSx, M8YCx.  
Use either Output 1 (connector) or Output 2 terminal for the input.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 5/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
■ MODEL: M8BS-16K1 (Azbil DCS J-HAM50/J-HMM00 module use / screw terminal block)  
I/O cable: J-RSL / J-RSK  
J-RRL / J-RRK  
• Location  
Input connector: 57GE-40500-751  
CN1: J-HAM50 / J-HMM00 module use  
The output 1 is connected to the connector.  
Pico-M LOCATION NO.  
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10 11 12 13 14 15 16  
10 11 12 13 14 15 16  
AZBIL DCS AI CONNECTOR  
■ CONNECTION DIAGRAM  
Power Supply Unit Code R, K  
Power Supply Unit Code KK, L  
CN1  
A
CN1  
A
B
C
D
B
C
D
Ch.1  
OUTPUT**  
Ch.1  
INPUT**  
Ch.1  
OUTPUT**  
Ch.1  
INPUT**  
+
+
OUTPUT 2  
OUTPUT 2  
A
B
C
D
A
B
C
D
Ch.16  
OUTPUT**  
Ch.16  
INPUT**  
Ch.16  
OUTPUT**  
Ch.16  
INPUT**  
+
+
OUTPUT 2  
OUTPUT 2  
1
2
3
3
4
5
3
4
5
U(+)  
FG  
U
POWER  
V(–)  
FG  
PWR1  
AC POWER  
V
FG  
U
*
PWR2  
AC POWER  
V
*
For power supply unit code KK only.  
** The input and output terminals are reversed for model M8YSx, M8YCx.  
Use either Output 1 (connector) or Output 2 terminal for the input.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 6/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
■ MODEL: M8BS-16K2 (Azbil DCS J-AOM10 module use / screw terminal block)  
I/I/O cable: J-RSL / J-RSK  
J-RRL / J-RRK  
• Location  
Output connector: 57GE-40500-751  
CN1: J-AOM10 module use  
The input is connected to the connector. Install the  
Extender Module (model: M8BWx) to unused channels  
in order to close the circuit.  
Pico-M LOCATION NO.  
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10 11 12 13 14 15 16  
10 11 12 13 14 15 16  
AZBIL DCS AO CONNECTOR  
■ CONNECTION DIAGRAM  
Power Supply Unit Code R, K  
Power Supply Unit Code KK, L  
CN1  
A
CN1  
A
B
C
D
B
C
D
Ch.1  
OUTPUT**  
Ch.1  
OUTPUT**  
+
+
Ch.1  
INPUT**  
Ch.1  
INPUT**  
A
B
C
D
A
B
C
D
Ch.16  
OUTPUT**  
Ch.16  
OUTPUT**  
+
+
Ch.16  
INPUT**  
Ch.16  
INPUT**  
1
2
3
3
4
5
3
4
5
U(+)  
FG  
U
POWER  
V(–)  
FG  
PWR1  
AC POWER  
V
FG  
U
*
PWR2  
AC POWER  
V
*
For power supply unit code KK only.  
** The input terminals are not usable for J-AOM10 module.  
The input and output terminals are reversed for models other than the M8YSx, M8YCx.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 7/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
■ MODEL: M8BS-16K3 (Azbil DCS J-HAM50/J-HMM00 module use / Azbil DCS J-HAM50/JHMM00 module use)  
I/O cable: J-RSL / J-RSK  
J-RRL / J-RRK  
• Location  
• Connector Pin Assignment (CN1, CN2)  
Input connector: 57GE-40500-751  
PIN NO.  
3
ASSIGNMENT  
ch.1 +  
PIN NO.  
4
ASSIGNMENT  
ch.1 –  
CN1: J-HAM50 / J-HMM00 module use  
(output 1)  
5
ch.2 +  
6
ch.2 –  
7
ch.3 +  
8
ch.3 –  
CN2: J-HAM50 / J-HMM00 module use  
(output 2)  
9
ch.4 +  
10  
26  
28  
30  
32  
12  
14  
16  
18  
20  
22  
24  
50  
ch.4 –  
27  
29  
31  
33  
11  
13  
15  
17  
19  
21  
23  
25  
ch.5 +  
ch.5 –  
ch.6 +  
ch.6 –  
Pico-M LOCATION NO.  
ch.7 +  
ch.7 –  
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10 11 12 13 14 15 16  
10 11 12 13 14 15 16  
ch.8 +  
ch.8 –  
ch.9 +  
ch.9 –  
ch.10 +  
ch.11 +  
ch.12 +  
ch.13 +  
ch.14 +  
ch.15 +  
ch.16 +  
ch.10 –  
ch.11 –  
ch.12 –  
ch.13 –  
ch.14 –  
ch.15 –  
ch.16 –  
AZBIL DCS AI CONNECTOR  
34 – 47: Unused  
1 – 2, 48 – 49 are connected.  
■ CONNECTION DIAGRAM  
Power Supply Unit Code R, K  
Power Supply Unit Code KK, L  
CN1  
CN2  
A
CN1  
CN2  
A
B
C
D
B
C
D
Ch.1  
INPUT**  
Ch.1  
INPUT**  
A
B
C
D
A
B
C
D
Ch.16  
INPUT**  
Ch.16  
INPUT**  
1
2
3
3
4
5
3
4
5
U(+)  
FG  
U
POWER  
V(–)  
FG  
PWR1  
AC POWER  
AC POWER  
V
FG  
U
*
PWR2  
V
*
For power supply unit code KK only.  
** The input and output terminals are reversed for model M8YSx, M8YCx.  
Use either Output 1 or Output 2 connector for the input.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 8/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
■ MODEL: M8BS-16Y1 (Yokogawa DCS VMx/PM1 card use (PS-40PE-D4T1-PN1) / screw terminal block)  
• Location  
CN1: VMx / PM1 card use*  
The input or output 1 is connected to the connector.  
Pico-M LOCATION NO.  
12345678910111213141516  
12345678910111213141516  
VM1/PM1/VM4 CARD INPUT or OUTPUT  
12345678  
1
2
345  
67  
8
VM2 CARD INPUT NO.  
VM2 CARD OUTPUT NO.  
*VMx / PM1 card (uses KS2 cable)  
VM1: analog input 16 points  
VM2: analog input 8 points / analog output 8 points  
VM4: analog output 16 points  
PM1: pulse input 16 points  
■ CONNECTION DIAGRAM  
Power Supply Unit Code R, K  
Power Supply Unit Code KK, L  
CN1  
A
B
C
D
CN1  
A
B
C
D
Ch.1  
OUTPUT**  
Ch.1  
INPUT**  
Ch.1  
OUTPUT**  
Ch.1  
INPUT**  
+
+
OUTPUT 2  
OUTPUT 2  
A
B
C
D
A
B
C
D
Ch.16  
OUTPUT**  
Ch.16  
INPUT**  
Ch.16  
OUTPUT**  
Ch.16  
INPUT**  
+
+
OUTPUT 2  
OUTPUT 2  
1
2
3
3
4
5
3
4
5
U(+)  
FG  
U
POWER  
V(–)  
FG  
PWR1  
AC POWER  
V
FG  
U
*
PWR2  
AC POWER  
V
*
For power supply unit code KK only.  
** The input and output terminals are reversed for model M8YSx, M8YCx.  
Use either Output 1 (connector) or Output 2 terminal for the input.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 9/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
■ MODEL: M8BS-16Y2 (Yokogawa DCS MAC2/PAC card use (PS-40PE-D4T1-PN1) / screw terminal block)  
• Location  
CN1: MAC2 / PAC card use*  
CN2: MAC2 / PAC card use* (dual redundancy)  
The input or output 1 is connected to the connector.  
Pico-M LOCATION NO.  
123456789 10 11 12 13 14 15 16  
112233445566 7 788  
ioioioioio  
i
o
i
o
i
o
MAC2/PAC CARD INPUT (i) or OUTPUT (o)  
*The MAC2 card (uses KS1 cable) is used to control I/O in  
Yokogawa DCS. Input and output, each 8 points, are  
paired and located as shown above. The PAC card I/O  
allocation is the same as that for the MAC2 card, except  
that pulse input modules are used.  
■ CONNECTION DIAGRAM  
Power Supply Unit Code R, K  
Power Supply Unit Code KK, L  
CN1  
CN2  
A
B
C
D
CN1  
CN2  
A
B
C
D
Ch.1  
INPUT**  
Ch.1  
INPUT**  
Ch.1  
OUTPUT**  
Ch.1  
OUTPUT**  
+
+
OUTPUT 2  
OUTPUT 2  
A
B
C
D
A
B
C
D
Ch.16  
INPUT**  
Ch.16  
INPUT**  
Ch.16  
OUTPUT**  
Ch.16  
OUTPUT**  
+
+
OUTPUT 2  
OUTPUT 2  
1
2
3
3
4
5
3
4
5
U(+)  
FG  
U
POWER  
V(–)  
FG  
PWR1  
AC POWER  
V
FG  
U
*
PWR2  
AC POWER  
V
*
For power supply unit code KK only.  
** The input and output terminals are reversed for model M8YSx, M8YCx.  
Use either Output 1 (connector) or Output 2 terminal for the input.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 10/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
EXTERNAL DIMENSIONS unit: mm (inch)  
■ M8BS-16U0-K, R  
480 (18.90)  
465 (18.31)  
440 (17.32)  
OUTPUT 2 TERM.  
POWER LED  
3–M3.5  
POWER TERMINALS  
7.3(.29)  
64–M3.5  
8.6 (.34)  
OUTPUT TERMINALS  
OUTPUT 1 TERM.  
CH1  
CH8  
CH9  
CH16  
+
– –  
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
6
+
+
+
+
4
+
+
+
+
+
+
+
+
+
+
+
+
– –  
8
1
2
3
1
2
3
5
7
9
10  
11  
12  
13  
14  
15  
16  
A B A B A B A B A B A B A B A B  
C D C D C D C D C D C D C D C D  
A B A B A B A B A B A B A B A B  
C D C D C D C D C D C D C D C D  
CH1  
CH8  
CH9  
CH16  
1
*
CT PROTECTOR (CTR)  
7.3 (.29)  
64–M3.5 INPUT TERMINALS  
*1. Included with M8CTx.  
■ M8BS-16U0-KK, L  
480 (18.90)  
465 (18.31)  
440 (17.32)  
OUTPUT 2 TERM.  
7.3(.29)  
3
*
5–M4  
POWER LED  
64–M3.5  
POWER TERMINALS  
OUTPUT TERMINALS  
OUTPUT 1 TERM.  
CH1  
CH8  
CH9  
CH16  
+
– –  
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
6
PWR2  
PWR1  
+
+
+
+
4
+
+
+
+
+
+
+
+
+
+
+
+
– –  
8
1
2
1
2
3
5
7
9
10  
11  
12  
13  
14  
15  
16  
5
4
3
2
1
5
4
3
2
1
A B A B A B A B A B A B A B A B  
C D C D C D C D C D C D C D C D  
A B A B A B A B A B A B A B A B  
C D C D C D C D C D C D C D C D  
CH1  
CH8  
CH9  
CH16  
1
*
4
POWER UNITS  
*
CT PROTECTOR (CTR)  
2
*
POWER LED  
7.3 (.29)  
64–M3.5 INPUT TERMINALS  
*1. PWR2 provided only for power supply unit code KK.  
*2. For power supply unit code KK.  
*3. For power supply unit code L.  
*4. Included with M8CTx.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 11/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
■ M8BS-16U1, U2, U5, K1, K2, K3, Y2-K, R  
480 (18.90)  
465 (18.31)  
440 (17.32)  
3–M3.5  
POWER TERMINALS  
7.2(.28)  
32–M3.5  
POWER LED  
1
*
OUTPUT TERMINALS  
8.6 (.34)  
CONNECTORS  
CN1  
CH1  
CH8  
CH9  
CH16  
+ – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + –  
1
2
3
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
2
*
CN2  
A B A B A B A B A B A B A B A B  
C D C D C D C D C D C D C D C D  
A B A B A B A B A B A B A B A B  
C D C D C D C D C D C D C D C D  
CH1  
CH8  
CH9  
CH16  
3
*
CT PROTECTOR (CTR)  
7.3 (.29)  
64–M3.5 INPUT TERMINALS  
*1. Not provided for M8BS-16U2 or K3.  
*2. For M8BS-16U2, K3 or Y2 only.  
*3. Included with M8CTx.  
■ M8BS-16U1, U2, U5, K1, K2, K3, Y2-KK, L  
480 (18.90)  
465 (18.31)  
440 (17.32)  
7.2(.28)  
3
*
5–M4  
POWER TERMINALS  
POWER LED  
32–M3.5  
OUTPUT TERMINALS  
4
*
CONNECTORS  
CN1  
CH1  
CH8  
CH9  
CH16  
+ – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + –  
PWR2  
PWR1  
1
2
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
5
*
5
4
3
2
1
5
4
3
2
1
CN2  
A B A B A B A B A B A B A B A B  
C D C D C D C D C D C D C D C D  
A B A B A B A B A B A B A B A B  
C D C D C D C D C D C D C D C D  
CH1  
CH8  
CH9  
CH16  
1
6
*
*
POWER UNITS  
CT PROTECTOR (CTR)  
2
*
POWER LED  
7.3 (.29)  
64–M3.5 INPUT TERMINALS  
*1. PWR2 provided only for power supply unit code KK.  
*2. For power supply unit code KK.  
*3. For power supply unit code L.  
*4. Not provided for M8BS-16U2 or K3.  
*5. For M8BS-16U2, K3 or Y2 only.  
*6. Included with M8CTx.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 12/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
■ M8BS-16Y1-K, R  
480 (18.90)  
465 (18.31)  
440 (17.32)  
3–M3.5  
POWER TERMINALS  
7.2(.28)  
POWER LED  
32–M3.5  
8.6 (.34)  
OUTPUT TERMINALS  
CONNECTOR  
CN1  
CH1  
CH8  
CH9  
CH16  
+ – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + –  
1
2
3
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
A B A B A B A B A B A B A B A B  
C D C D C D C D C D C D C D C D  
A B A B A B A B A B A B A B A B  
C D C D C D C D C D C D C D C D  
CH1  
CH8  
CH9  
CH16  
1
*
CT PROTECTOR (CTR)  
7.3 (.29)  
64–M3.5 INPUT TERMINALS  
*1. Included with M8CTx.  
■ M8BS-16Y1-KK, L  
480 (18.90)  
465 (18.31)  
440 (17.32)  
7.2(.28)  
3
*
5–M4  
POWER TERMINALS  
POWER LED  
32–M3.5  
OUTPUT TERMINALS  
CONNECTOR  
CN1  
CH1  
CH8  
CH9  
CH16  
+ – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + –  
PWR2  
PWR1  
1
2
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
5
4
3
2
1
5
4
3
2
1
A B A B A B A B A B A B A B A B  
C D C D C D C D C D C D C D C D  
A B A B A B A B A B A B A B A B  
C D C D C D C D C D C D C D C D  
CH1  
CH8  
CH9  
CH16  
1
4
*
*
POWER UNITS  
CT PROTECTOR (CTR)  
2
*
POWER LED  
7.3 (.29)  
64–M3.5 INPUT TERMINALS  
*1. PWR2 provided only for power supply unit code KK.  
*2. For power supply unit code KK.  
*3. For power supply unit code L.  
*4. Included with M8CTx.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 13/14  
http://www.m-system.co.jp/  
MODEL: M8BS-16  
Specifications are subject to change without notice.  
M8BS-16 SPECIFICATIONS  
ES-5490 Rev.14 Page 14/14  
http://www.m-system.co.jp/  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY