MD72WD-320 [MSYSTEM]

Lightning Surge Protectors for Electronics Equipment M-RESTER;
MD72WD-320
型号: MD72WD-320
厂家: M-SYSTEM    M-SYSTEM
描述:

Lightning Surge Protectors for Electronics Equipment M-RESTER

文件: 总3页 (文件大小:127K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: MD72WD  
Lightning Surge Protectors for  
Electronics Equipment M-RESTER  
[2] SAFETY APPROVAL  
0: None  
2: CENELEC intrinsic safety (ATEX)  
LIGHTNING SURGE PROTECTOR FOR  
[3] OPTIONS  
blank: none  
TWO-WIRE SIGNAL LOOP  
(ultra-slim; 2 channels)  
/Q: With options (specify the specification)  
(CENELEC intrinsic safety (ATEX) not available)  
Functions & Features  
• High discharge current capacity 20 kA (8 / 20 μs), 1 kA (10  
/ 350 μs)  
• Ultra-thin 7-mm-wide module can be mounted  
in high density  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
• 2 channels packed in one housing  
• Excellent protection employing multi-stage SPD circuits  
• DIN rail mounting and grounding  
/C02: Polyurethane coating  
GENERAL SPECIFICATIONS  
Construction: Slim-sized front terminal structure  
Degree of protection: IP20  
Typical Applications  
• Protecting a 2-wire transmitter loop  
• Protecting an electronic device I/O  
Connection: Euro terminal block (torque 0.3 N·m)  
Applicable wire size: 0.2 – 2.5 mm2, stripped length 8 mm  
Grounding: DIN Rail  
7 (.28)  
Housing material: Flame-resistant resin (black)  
INSTALLATION  
95  
Operating temperature: -25 to +85°C (-13 to +185°F)  
(See Safety Parameters for use in a hazardous location.)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: DIN Rail (TH35-7.5, 1-mm-thick)  
Oxide film on the surface of an aluminium DIN rail may  
lower the electric conductivity between this module and the  
ground. Use a steel or copper rail.  
(3.74)  
98  
(3.86)  
mm (inch)  
Weight: 70 g (2.5 oz)  
MODEL: MD72WD–[1][2][3]  
ORDERING INFORMATION  
• Code number: MD72WD-[1][2][3]  
Specify a code from below for each [1] through [3].  
(e.g. MD72WD-320/Q)  
For the safety approval code 2, specify the product’s  
destination country using Ordering Information Sheet (No.  
ESU-8057).  
• Specify the specification for option code /Q  
(e.g. /C01)  
[1] NOMINAL VOLTAGE  
07: 7 V DC  
16: 16 V DC  
32: 32 V DC  
MD72WD SPECIFICATIONS  
ES-8068 Rev.6 Page 1/3  
http://www.m-system.co.jp/  
MODEL: MD72WD  
PERFORMANCE  
MODEL NO.  
MD72WD-07  
7ꢀ  
MD72WD-16  
MD72WD-32  
32ꢀ  
Max. continuous operating voltage (Uc)  
Line to Line  
Line to Earth  
Line to Line  
Line to Earth  
Line to Line  
Other sections  
Line to Line  
Other sections  
16ꢀ  
16ꢀ  
45ꢀ  
50ꢀ  
7ꢀ  
32ꢀ  
ꢀoltage protection level (Up)  
@6kꢀ (1.2 / 50 µs)  
30ꢀ  
70ꢀ  
35ꢀ  
75ꢀ  
Leakage current @Uc  
≤ 10µA  
≤ 10µA  
≤ 5µA  
≤ 5µA  
Response time  
≤ 4 nsec.  
≤ 4 nsec.  
Max. discharge current (Imax)  
Nominal current (IN)  
20kA (8 / 20 µs), 1.0kA (10 / 350 µs)  
250mA  
Internal series resistance  
Surge protection  
4.7Ω 20ꢁ per line  
IEC 61643-21 Categories C1, C2, D1  
STANDARDS & APPROVALS  
EU conformity:  
ATEX Directive  
Ex ia EN 60079-11  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
RoHS Directive  
EN 50581  
Safety approval:  
CENELEC: Intrinsic safety (ATEX)  
II 1G, Ex ia IIC; T4 and T5  
EN 60079-0  
EN 60079-11  
SAFETY PARAMETERS  
CENELEC / ATEX IS DATA  
MD72WD-07 MD72WD-16 MD72WD-32  
Ui (Vmax)  
7V  
any  
16V  
any  
32V  
any  
Ii (Imax)  
Ci  
Li  
50 nF  
35 nF  
15 nF  
0 µH  
0 µH  
0 µH  
Temp. Class  
Range  
Parameter  
1.3W  
-25 to +40°C  
-25 to +60°C  
-25 to +80°C  
-25 to +40°C  
Pi  
T4  
T5  
1.2W  
1.0W  
1.0W  
MD72WD SPECIFICATIONS  
ES-8068 Rev.6 Page 2/3  
http://www.m-system.co.jp/  
MODEL: MD72WD  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
8–M3 EURO  
TERMINAL  
WIRE INSERTION ANGLE: approx. 20°  
8
6
5
4
8
DIN RAIL  
ADAPTOR  
6
5
DIN RAIL  
4
(35 mm wide)  
1
2
3
7
1
2
3
7
[1.5 (.06)]  
98 (3.86)  
7
(.28)  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
4 – 20mA Field-mount  
Transmitter Surge Protector  
Current Loop  
Supply  
Surge Side  
Protected Side  
1
+
+
4
DISCHARGE  
ELEMENT  
5
2
FG  
(model: MD6x)  
4 – 20mA Field-mount  
Transmitter Surge Protector  
Current Loop  
Supply  
+
+
6
8
3
7
DISCHARGE  
ELEMENT  
FG  
(model: MD6x)  
DIN RAIL ADAPTOR  
(for grounding)  
*3  
*1  
Crossover Wire  
DIN RAIL  
*2  
Grounding  
*1. Oxide film on the surface of an aluminium rail may lower the electric conductivity between this module and the ground.  
Use a steel or copper rail.  
*2. Be sure to ground the DIN rail. Recommended grounding resistance ≤100  
*3. Cross-wire between the DIN rail or the terminal 7 and the metal housing of the protected device to equalize  
the earth potential. Ground only the surge protector when the protected device has no ground terminal.  
Specifications are subject to change without notice.  
MD72WD SPECIFICATIONS  
ES-8068 Rev.6 Page 3/3  
http://www.m-system.co.jp/  

相关型号:

MD72WD-320/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD72WD-322

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD72WD-322/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD73W

Lightning Surge Protectors for Lightning Surge Protectors for
MSYSTEM

MD73W-320

Lightning Surge Protectors for Lightning Surge Protectors for
MSYSTEM

MD73W-320/Q

Lightning Surge Protectors for Lightning Surge Protectors for
MSYSTEM

MD73W-322

Lightning Surge Protectors for Lightning Surge Protectors for
MSYSTEM

MD73W-322/Q

Lightning Surge Protectors for Lightning Surge Protectors for
MSYSTEM

MD74R

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD74R-FF

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD74R-FF/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD74R-FG

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM