MD7AP [MSYSTEM]

Lightning Surge Protectors for Electronics Equipment M-RESTER;
MD7AP
型号: MD7AP
厂家: M-SYSTEM    M-SYSTEM
描述:

Lightning Surge Protectors for Electronics Equipment M-RESTER

文件: 总2页 (文件大小:110K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: MD7AP  
Lightning Surge Protectors for  
Electronics Equipment M-RESTER  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
LIGHTNING SURGE PROTECTOR FOR  
AC POWER SUPPLY  
(max. 3A; ultra-slim)  
GENERAL SPECIFICATIONS  
Construction: Slim-sized front terminal structure  
Degree of protection: IP20  
Functions & Features  
• High discharge current capacity 10 kA (8 / 20 μs)  
• Ultra-thin 7-mm-wide module can be mounted  
in high density  
Connection: Euro terminal block (torque 0.3 N·m)  
Applicable wire size: 0.2 – 2.5 mm2, stripped length 8 mm  
Grounding: DIN Rail  
• Excellent protection employing multi-stage SPD circuits  
• DIN rail mounting and grounding  
• Power line monitor LED  
Housing material: Flame-resistant resin (black)  
Monitor LED: Green LED turns ON when the voltage is  
supplied; OFF when the safety fuse is blown.  
Typical Applications  
• Protecting small capacity AC control drives  
• Protecting small capacity power supply units  
INSTALLATION  
AC power supply: Max. output current 3 A  
Caution: Use an AC power source with the overload current  
protection function.  
7 [.28]  
Operating temperature: -25 to +85°C (-13 to +185°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: DIN Rail (TH35-7.5, 1-mm-thick)  
Oxide film on the surface of an aluminium DIN rail may  
lower the electric conductivity between this module and the  
ground. Use a steel or copper rail.  
95  
[3.74]  
Weight: 85 g (3.0 oz)  
98  
[3.86]  
PERFORMANCE  
mm [inch]  
LINE TO LINE  
LINE TO  
EARTH  
MD7AP-100 MD7AP-200  
Max. continuous  
operating voltage (Uc)  
140V AC  
275V AC  
275V AC  
MODEL: MD7AP-[1][2]  
Voltage protection level  
(Up) @6kV (1.2 / 50 µs)  
±550V  
±±50V  
±±50V  
ORDERING INFORMATION  
• Code number: MD7AP-[1][2]  
Specify a code from below for each of [1] and [2].  
(e.g. MD7AP-100/Q)  
Leakage current @Uc  
Response time  
≤ 1mA  
≤ 1mA  
≤ 1mA  
≤ 20 nsec. ≤ 20 nsec. ≤ 20 nsec.  
10kA (± / 20 µs)  
Max. discharge current  
(Imax)  
Nominal current (IN)  
Surge protection  
3A  
• Specify the specification for option code /Q  
(e.g. /C01)  
IEC 61643-21 Categories C1, C2, D1  
EN 61643-21 Categories C1, C2, D1  
[1] OPERATIONAL VOLTAGE  
100: 100 V / 110 V / 120 V AC  
STANDARDS & APPROVALS  
EU conformity:  
200: 200 V / 220 V / 240 V AC  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
EN 61643-21  
[2] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
RoHS Directive  
MD7AP SPECIFICATIONS  
ES-8069 Rev.6 Page 1/2  
https://www.m-system.co.jp/  
MODEL: MD7AP  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]  
8–M3 EURO  
TERMINAL  
WIRE INSERTION ANGLE: approx. 20°  
8
6
5
4
8
DIN RAIL  
ADAPTOR  
6
5
DIN RAIL  
4
(35 mm wide)  
MONITOR LED  
1
2
3
7
1
2
3
7
(1.5 [.06])  
98 [3.86]  
7
[.28]  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
*4  
AC Power  
Supply  
(protected)  
Electronic  
Protected  
Device  
Protected  
Side  
Surge  
Side  
Surge  
Side  
M-RESTER  
M-RESTER  
Side  
(protected)  
*5  
1
4
4
1
U
U
SAFETY  
FUSE  
SAFETY  
FUSE  
MONITOR LED  
MONITOR LED  
INDICATOR  
CIRCUIT  
INDICATOR  
CIRCUIT  
2
3
7
5
6
8
5
6
8
2
3
7
V
V
SAFETY  
FUSE  
SAFETY  
FUSE  
SAFETY  
FUSE  
SAFETY  
FUSE  
DIN RAIL ADAPTOR  
(for grounding)  
DIN RAIL ADAPTOR  
(for grounding)  
FG  
FG  
*3  
*3  
Crossover Wire  
Crossover Wire  
*1  
*1  
DIN RAIL  
DIN RAIL  
*2  
*2  
Grounding  
Grounding  
*1. Oxide film on the surface of an aluminium rail may lower the electric conductivity between this module and the ground.  
Use a steel or copper rail.  
*2. Be sure to ground the DIN rail. Recommended grounding resistance ≤100Ω  
*3. Cross-wire between the DIN rail and the metal housing of the protected device to equalize the earth potential.  
Ground only the surge protector when the protected device has no ground terminal.  
*4. Use an AC power source with the overload current protection function. (maximum output current 3A)  
*5. Install a current limiting element (capacity 3) when the output current exceeds 3A.  
Specifications are subject to change without notice.  
MD7AP SPECIFICATIONS  
ES-8069 Rev.6 Page 2/2  
https://www.m-system.co.jp/  

相关型号:

MD7AP-100

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7AP-100/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7AP-200

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7AP-200/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7AST

Lightning Surge Protectors for
MSYSTEM

MD7AST-24FF

Lightning Surge Protectors for
MSYSTEM

MD7AST-24FF/Q

Lightning Surge Protectors for
MSYSTEM

MD7AST-24FG

Lightning Surge Protectors for
MSYSTEM

MD7AST-24FG/Q

Lightning Surge Protectors for
MSYSTEM

MD7AST-60FF

Lightning Surge Protectors for
MSYSTEM

MD7AST-60FF/Q

Lightning Surge Protectors for
MSYSTEM

MD7AST-60FG

Lightning Surge Protectors for
MSYSTEM