MD7LWA-FF [MSYSTEM]

Lightning Surge Protectors for Electronics Equipment M-RESTER;
MD7LWA-FF
型号: MD7LWA-FF
厂家: M-SYSTEM    M-SYSTEM
描述:

Lightning Surge Protectors for Electronics Equipment M-RESTER

文件: 总3页 (文件大小:120K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: MD7LWA  
Lightning Surge Protectors for  
Electronics Equipment M-RESTER  
APPLICABLE NETWORK  
LonWorks FTT-10A network  
This unit is not applicable to LonWorks Link Power network.  
LIGHTNING SURGE PROTECTOR FOR  
GENERAL SPECIFICATIONS  
Construction: Slim-sized front terminal structure  
Degree of protection: IP20  
LonWorks  
(ultra-slim, FTT-10A)  
Functions & Features  
Connection: Euro terminal block (torque 0.3 N·m)  
• High discharge current capacity 20 kA (8 / 20 μs), 1 kA (10  
/ 350 μs)  
Applicable wire size: 0.2 – 2.5 mm2, stripped length 8 mm  
Grounding: DIN Rail  
• Ultra-thin 7-mm-wide module can be mounted in high  
density  
Housing material: Flame-resistant resin (black)  
• Excellent protection employing multi-stage SPD circuits  
• DIN rail mounting and grounding  
• Shield terminal provided  
INSTALLATION  
Operating temperature: -25 to +85°C (-13 to +185°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: DIN Rail (TH35-7.5, 1-mm-thick)  
Oxide film on the surface of an aluminium DIN rail may  
lower the electric conductivity between this module and the  
ground. Use a steel or copper rail.  
7 [.28]  
Weight: 70 g (2.5 oz)  
95  
[3.74]  
PERFORMANCE  
LINE TO  
LINE  
LINE TO  
EARTH  
SHLD TO  
EARTH  
98  
[3.86]  
Max. continuous  
operating voltage (Uc)  
±±.5V  
±ꢀ0V  
≤ 5µA  
±±00V  
±ꢀ30V  
≤ 20µA  
±±60V*±  
±ꢁ00V*±  
≤ 5µA*±  
mm [inch]  
Voltage protection level  
(Up) @4kV (±.2 / 50 µs)  
Leakage current @Uc  
Response time  
MODEL: MD7LWA–[1][2]  
≤ 4 nsec. ≤ 20 nsec. ≤ 20 nsec.*±  
Approx. capacitance  
@±0 kHz  
±00 pF  
±00 pF  
5 pF*±  
ORDERING INFORMATION  
• Code number: MD7LWA-[1][2]  
Specify a code from below for each of [1] and [2].  
(e.g. MD7LWA-FF/Q)  
Max. discharge current  
(Imax)  
20kA (ꢁ / 20 µs)  
±.0kA (±0 / ꢀ50 µs)  
Nominal current (IN)  
Internal series resistance  
Insertion loss  
±00mA  
≤ ꢀ.ꢀΩ including return  
• Specify the specification for option code /Q  
(e.g. /C01)  
-0.5 dB max. @DC...5 MHz, Z0 = ±00Ω  
IEC 6±64ꢀ-2± Categories C±, C2, D±  
Surge protection  
*±. Values for the $oating type (FF). Shortcircuited for the ground-  
ing type (FG).  
[1] SHIELD TERMINAL (to earth)  
FF: Floating  
FG: Grounding  
STANDARDS & APPROVALS  
EU conformity:  
[2] OPTIONS  
EMC Directive  
blank: none  
EMI EN 61000-6-4  
/Q: Options other than the above (specify the specification)  
EMS EN 61000-6-2  
RoHS Directive  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
MD7LWA SPECIFICATIONS  
ES-8060 Rev.9 Page 1/3  
https://www.m-system.co.jp/  
MODEL: MD7LWA  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]  
8–M3 EURO  
TERMINAL  
WIRE INSERTION ANGLE: approx. 20°  
8
6
5
4
8
DIN RAIL  
ADAPTOR  
6
5
DIN RAIL  
4
(35 mm wide)  
1
2
3
7
1
2
3
7
(1.5 [.06])  
98 [3.86]  
7
[.28]  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Surge Side  
Protected Side  
M-RESTER  
Protected Device  
*1  
Series Resistance  
4
1
+
NET  
A, B  
DISCHARGE  
ELEMENT  
5
6
8
2
3
7
*3  
SHLD  
(SHLD)  
DISCHARGE  
ELEMENT  
*2  
DIN RAIL ADAPTOR  
(for grounding)  
FG  
*4  
*6  
Crossover Wire  
DIN RAIL  
*5  
Grounding  
*1. Be sure to use twisted-pair cables.  
*2. Choose the M-RESTER FG when the shield wire is to be grounded.  
*3. When the twisted-pair cable is with a shield, connect it to the surge protector’s terminal 8, and follow instructions given by the protected  
device for the terminal 7. When SHLD is not isolated from NET A / B, DO NOT connect the terminal 7 to SHLD.  
*4. Oxide film on the surface of an aluminium rail may lower the electric conductivity between this module and the ground. Use a steel or copper rail.  
*5. Be sure to ground the DIN rail. Recommended grounding resistance max. 100 ohms.  
*6. Cross-wire from the DIN rail to the metal housing of the protected device to equalize the ground potential.  
Ground only the surge protector when the protected device has no grounding terminal.  
MD7LWA SPECIFICATIONS  
ES-8060 Rev.9 Page 2/3  
https://www.m-system.co.jp/  
MODEL: MD7LWA  
P ꢃepꢁ/ꢁC ꢂiꢃet  
M-RESTER  
SurgeꢁSide  
ProtectedꢁSide  
NetꢄorꢅꢁC ꢂpe  
NetꢄorꢅꢁC ꢂpe  
CrossoverꢁWire  
G
FG  
FG  
Protected  
Devices  
(Nodes)  
Grouꢃdiꢃg  
P ꢃepꢁ/ꢁC ꢂiꢃet  
M-RESTER  
SurgeꢁSide  
ProtectedꢁSide  
NetꢄorꢅꢁC ꢂpe  
CrossoverꢁWire  
G
FG  
FG  
Protected  
Devices  
(Nodes)  
•TꢀeꢁM-RESTERꢁisꢁ aapic ꢂpeꢁtoꢁꢃetꢄorꢅsꢁꢄꢀicꢀꢁcoꢃsistꢁoꢃplꢁoꢆꢁFTT-ꢇ10A  
ꢁꢁNotꢁ aapic ꢂpeꢁtoꢁtꢀeꢁoꢃesꢁcoꢃꢃectedꢁtoꢁLiꢃꢅꢁPoꢄerꢁꢃetꢄorꢅA  
•ꢁTꢀeꢁm ximumꢁꢃumꢂerꢁoꢆꢁꢃodesꢁcoꢃꢃect ꢂpeꢁtoꢁtꢀeꢁꢃetꢄorꢅꢁsegmeꢃtꢁisꢁreducedꢁꢂlꢁoꢃe  
ꢁꢁꢄꢀeꢃꢁoꢃeꢁuꢃitꢁoꢆꢁM-RESTERꢁisꢁ ddedA  
•ꢁWꢀeꢃꢁtꢀeꢁdist ꢃceꢁꢂetꢄeeꢃꢁꢃodesꢁ reꢁrep tiveplꢁpoꢃgꢁ(eAgAꢁgrouaedꢁ ꢃdꢁsea r tedꢁꢂlꢁc ꢂiꢃets),  
ꢁꢁiꢃst ppꢁtꢀeꢁM-RESTERꢁꢂlꢁe cꢀꢁgrouaꢁoꢆꢁdevicesAꢁꢁIꢃsertꢁtꢀeꢁM-RESTERꢁ tꢁtꢀeꢁsurgeꢁsideꢁoꢆꢁtꢀeꢁꢃetꢄorꢅA  
•ꢁForꢁdet ipedꢁiꢃꢆorm tioꢃꢁoꢃꢁtꢀeꢁꢃetꢄorꢅ,ꢁreꢆerꢁtoꢁLONWORKSꢁFTT-ꢇ10ꢁFreeꢁToaopoglꢁTr ꢃsceiverꢁ  
ꢁꢁUser’sꢁGuideꢁarovidedꢁꢂlꢁEcꢀepoꢃA  
Specifications are subject to change without notice.  
MD7LWA SPECIFICATIONS  
ES-8060 Rev.9 Page 3/3  
https://www.m-system.co.jp/  

相关型号:

MD7LWA-FF/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7LWA-FG

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7LWA-FG/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7P19130H

RF Power Field Effect Transistors
FREESCALE

MD7P19130HR3

RF Power Field Effect Transistors
FREESCALE

MD7P19130HSR3

RF Power Field Effect Transistors
FREESCALE

MD7P19130H_10

RF Power Field Effect Transistors
FREESCALE

MD7PA

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PA-FF0

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PA-FF0/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PA-FG0

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MD7PA-FG0/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM