MODEL: MDP-200  
Lightning Surge Protectors for  
Electronics Equipment M-RESTER  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Surge protection type: Voltage limiting type one-port SPD  
Connection: M4 screw terminals (torque 0.8 N·m)  
Screw terminal: Nickel-plated steel  
LIGHTNING SURGE PROTECTOR FOR  
AC/DC POWER SUPPLY USE (1A)  
Functions & Features  
Housing material: Flame-resistant resin (black)  
• Designed for AC and specifically for DC power supplies up  
to 1 A  
INSTALLATION  
Operating temperature: -5 to +60°C (23 to 140°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
• Beneficial for protecting instruments from  
counter electromotive force by inductors and of course  
normal lightning surges entering from power supply lines  
• 1 A fuse incorporated in element circuit  
Weight:  
90 g (0.20 lb), standard  
115 g (0.25 lb), with DIN rail mounting adapter  
23.5 (.93)  
PERFORMANCE  
Max. line voltage (Uc): 250 V AC (peak voltage 355V)  
Lot.NO  
N1430B  
100  
(3.94)  
Discharge voltage:  
JPAN  
MADEIN  
Line to line: 410 V  
M•STER  
MODEL  
Line to earth: 410 V  
Voltage protection level (Up):  
Line to line: 800 V  
80 (3.15)  
mm (inch)  
Line to earth: 800 V  
Response time: ≤ 0.1 μsec.  
Leakage current:  
MODEL: MDP–200[1]  
Line to line: ≤ 0.1 mA @ 300 V DC  
Line to earth: ≤ 0.1 mA @ 300 V DC  
Max. discharge current (Imax): 1000 A (8/ 20 μsec.)  
ORDERING INFORMATION  
• Code number: MDP-200[1]  
Specify a code from below for [1].  
(e.g. MDP-200/A33/Q)  
Nominal current (I ): 1.0 A  
N
Dielectric strength of the base module:  
1500 V AC @ 1 minute (G terminal to other terminals)  
Internal series resistance: ≤ 0.4 Ω (including return)  
Surge protection: IEC 61643-1 Class III  
• Specify the specification for option code /Q  
(e.g. /C01)  
[1] OPTIONS (multiple selections)  
DIN Rail Mounting Adapter  
blank: Without  
/A33: With adapter (model A-33)  
Other Options  
blank: none  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
/C03: Rubber coating  
MDP-200 SPECIFICATIONS  
ES-8103 Rev.2 Page 1/4  
http://www.m-system.co.jp/  
MODEL: MDP-200  
CONNECTION EXAMPLES  
CONTROL ROOM  
FIELD  
M-RESTER  
1A  
M-RESTER  
1A  
S1  
S2  
P1  
P2  
S1  
S2  
P1  
P2  
Discharge  
Element  
Discharge  
Element  
R
1A  
1A  
Relay,  
Coil, etc.  
G
G
The M-RESTER must be connected with its terminals S1 and S2 faced on power source side  
in order that the fuses would be blown in case of shortcircuit of the discharge element.  
GROUNDING  
PROTECTED  
EQUIPMENT  
M-RESTER  
G
G
GROUNDING  
(100 ohms or less)  
CROSSOVER WIRE  
A crossover wire between M-RESTER ground and the ground or  
metallic housing of the equipment is required for protection.  
If the protected equipment has no ground terminal, ground the  
M-RESTER only.  
When the M-RESTER is mounted with DIN Rail Mounting Adapter,  
connect the grounding wire to the mounting screw of the M-RESTER.  
MDP-200 SPECIFICATIONS  
ES-8103 Rev.2 Page 2/4  
http://www.m-system.co.jp/  
MODEL: MDP-200  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
STANDARD  
80 (3.15)  
53 (2.09)  
2–5 (.20) dia.  
MTG HOLE  
23.5 (.93)  
27 (1.06)  
HEAD ELEMENT  
P1  
P2  
BASE  
4–M4 TERMINAL SCREW  
S1  
S2  
GROUND TERMINAL (G)  
(used as mounting bracket)  
WITH DIN RAIL MOUNTING ADAPTER  
8.5  
(.33)  
[3.3 (.13)]  
80 (3.15)  
53 (2.09)  
27 (1.06)  
23.5 (.93)  
DIN RAIL  
35mm wide  
P1 P2  
4–M4 TERMINAL SCREW  
S1 S2  
2–M4 MOUNTING SCREW  
(used as ground terminal (G))  
MOUNTING REQUIREMENTS unit: mm (inch)  
2–M4 SCREW  
25 (.97) min.  
MDP-200 SPECIFICATIONS  
ES-8103 Rev.2 Page 3/4  
http://www.m-system.co.jp/  
MODEL: MDP-200  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
1A  
S1  
S2  
P1  
P2  
ELEMENT  
Discharge  
Elements  
POWER  
SUPPLY  
TO EQUIPMENT  
1A  
BASE  
G
GROUND TERMINAL  
(used as mounting attachment)  
Note: When the head element is removed, the line will be open.  
Specifications are subject to change without notice.  
MDP-200 SPECIFICATIONS  
ES-8103 Rev.2 Page 4/4  
http://www.m-system.co.jp/  

相关型号:

MDP-200/A33

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-200/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-200T

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-200T/A33

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-200T/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-24-1

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-24-1/A33

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-24-1/CE

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-24-1/N

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-24-1/Q

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-24-1/UL

Lightning Surge Protectors for Electronics Equipment M-RESTER
MSYSTEM

MDP-3

Interconnection Device
POMONA