R3-GC1 [MSYSTEM]

Remote I/O R3 Series CC-Link INTERFACE MODULE;
R3-GC1
型号: R3-GC1
厂家: M-SYSTEM    M-SYSTEM
描述:

Remote I/O R3 Series CC-Link INTERFACE MODULE

文件: 总6页 (文件大小:164K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: R3-GC1  
Remote I/O R3 Series  
CAUTION  
• When selecting network modules, note that this unit is not  
designed to be used with network modules of certain types  
or versions.  
CC-Link INTERFACE MODULE  
(CC-Link Ver.1.10/Ver.2.00)  
• This unit CANNOT be used with R3-NC2, R3-NEIP1, R3-NFx,  
and R3-NLx.  
Functions & Features  
• Enables other protocol interface modules to communicate  
with CC-Link data (gateway).  
• This unit CAN be used with:  
R3-NM3 and R3-NML3 of firmware version V1.00 or higher;  
R3-NC1, R3-NC3, R3-NDx, R3-NE1, R3-NFL1, R3-NM1,  
R3-NM4, and R3-NP1 of firmware version V2.00 or higher;  
and  
• Recognized as an analog I/O mixed module by other  
protocol interface modules.  
Typical Applications  
other models of any firmware versions.  
• A gateway for CC-Link and Modbus.  
PACKAGE INCLUDES...  
27.5 [1.08]  
• Terminating resistor (110 Ω, 0.5 W)  
GENERAL SPECIFICATIONS  
Connection  
130  
[5.12]  
Network: Euro type connector terminal  
(applicable wire size: 0.2 to 2.5 mm2, stripped length 7  
109  
[4.29]  
mm)  
Internal bus: Via the Installation Base  
(model: R3-BSx)  
mm [inch]  
Internal Power: Via the Installation Base  
(model: R3-BSx)  
MODEL: R3-GC1S[1]  
RUN contact output: M3 separable screw terminal  
(torque 0.5 N·m)  
ORDERING INFORMATION  
• Code number: R3-GC1S[1]  
Specify a code from below for [1].  
(e.g. R3-GC1S/CE/Q)  
Screw terminal: Nickel-plated steel  
Isolation: CC-Link to internal bus or internal power to RUN  
contact output  
RUN indicator: Bi-color (green/red) LED  
Green turns ON when CC-Link communication is normal and  
fieldbus communication on the R3 Network module side is  
also normal; or  
• Specify the specification for option code /Q  
(e.g. /C01)  
Red turns ON when receiving data.  
COMMUNICATION MODE  
Indication selectable with DIP SW3-4.  
ERR indicator: Bi-color (green/red) LED  
Green turns ON/blinks in communication errors (OFF with  
wire breakdown; Green blinks with setting errors); or  
Red turns ON when transmitting data.  
Indication selectable with DIP SW3-4.  
RUN CONTACT OUTPUT  
S: Single  
[1] OPTIONS (multiple selections)  
Standards & Approvals  
blank: Without CE  
/CE: CE marking  
Other Options  
RUN contact: Turns on while the green RUN LED is ON  
(only when CC-Link communication and the  
field bus built-in the interface module are in normal).  
Rated load: 250 V AC @ 0.5 A (cos ø = 1)  
30 V DC @ 0.5 A (resistive load)  
blank: none  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
(Less than 50 V AC to conform with EU Directive)  
Maximum switching voltage: 250 V AC or 30 V DC  
Maximum switching power: 250 VA or 150 W  
Minimum load: 1 V DC @ 1 mA  
/C02: Polyurethane coating  
/C03: Rubber coating  
R3-GC1 SPECIFICATIONS  
ES-8462 Rev.7 Page 1/6  
https://www.m-system.co.jp/  
MODEL: R3-GC1  
Mechanical life: 2 × 10 cycles (300 cycles/min.)  
7
When driving an inductive load, external contact protection  
and noise quenching recommended.  
CC-Link COMMUNICATION  
CC-Link: Both Version 1.10 and Version 2.00 are available.  
Select the version with DIP SW3.  
Cyclic expansion: 2, 4, 8 folds (Function selected with DIP  
SW)  
Station No. setting: Rotary switch; 1 – 64  
Baud rate setting: Rotary switch  
156kbps, 625kbps, 2.5Mbps, 5Mbps, 10Mbps  
Station type: Remote device station  
Required nodes: 4  
Ver.1.10: (128 I/O points, 16 words)  
Ver.2.00: (112 I/O points, 16 words) × m (m = expanded  
cyclic setting)  
Transmission cable: Approved for CC-Link  
INSTALLATION  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: Installation Base (model: R3-BSx)  
Weight: 200 g (0.44 lb)  
PERFORMANCE  
Data allocation  
Ver.1.10: 16  
Ver.2.00: 16 × m (m = expanded cyclic setting)  
Current consumption: 120 mA  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute  
(CC-Link to internal bus or internal power to RUN contact  
output)  
2000 V AC @ 1 minute (power input to FG; isolated on the  
power supply module)  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
RoHS Directive  
R3-GC1 SPECIFICATIONS  
ES-8462 Rev.7 Page 2/6  
https://www.m-system.co.jp/  
MODEL: R3-GC1  
EXTERNAL VIEW  
FRONT VIEW  
SIDE VIEW  
SA1  
10  
SA2  
X
Station No. Rotary SW  
Baud Rate Rotary SW  
X1  
RUN LED  
B RATE  
ERR LED  
Functions  
SW3  
FG  
SLD  
DG  
DB  
DA  
Configuration Jack  
LED Function  
4
3
2
1
Euro Type  
Expanded  
Cyclic  
Connector Terminal  
CC-Link  
Version  
1
2
3
4
ON  
5
6
COMMUNICATION CABLE CONNECTIONS  
MASTER UNIT  
R3-GC1  
I/O UNIT  
TERMINATOR  
blue  
DA  
DB  
DA  
DB  
DA  
DB  
white  
yellow  
DG  
SLD  
FG  
DG  
SLD  
FG  
DG  
SLD  
FG  
R3-GC1 SPECIFICATIONS  
ES-8462 Rev.7 Page 3/6  
https://www.m-system.co.jp/  
MODEL: R3-GC1  
TRANSMISSION DATA DESCRIPTIONS  
Use the DIP SW located at the side of the module to specify expanded cyclic setting. 16 words input and 16 words output  
make 1 cyclic. Max. 8 cyclic (128 words input, 128 words output) transmission is available. 1 cyclic is equivalent to 1 I/O  
module (analog input 16 points, analog output 16 points). Max. 8 I/O modules can be assigned to 8 slots.  
Note: Do not mount any modules in the slots which are occupied by virtual modules. If a real I/O module is mounted in the  
slot, an internal bus error occurs and the ERR LED turns on. Max. 16 real I/O modules and virtual modules are available.  
The interface module can not read the data for more than 16 modules.  
WHEN R3-GC1 IS MOUNTED ON SLOT NO. 2 (4 CYCLIC)  
Real I/O modules are mounted on Slots No. 1 and 2, however, the network module (R3-NE1) recognizes that each of Slots No. 1  
to 5 is occupied. That is, R3-NE1 recognizes R3-SV4 mounted on Slot No.1 as it is and recognizes R3-GC1 mounted on Slot No.2  
as divided into four modules and occupying Slots No. 2 to 5.  
SLOT  
REAL MODULE VERTUAL MODULE NO. OF WORDS  
R3-BS08  
Slot No.1  
Slot No.2  
Slot No.3  
Slot No.4  
Slot No.5  
Slot No.6  
Slot No.7  
Slot No.8  
R3-SV4  
R3-GC1  
R3-SV4  
R3-GC1 (1/4)  
R3-GC1 (2/4)  
R3-GC1 (3/4)  
R3-GC1 (4/4)  
No module  
R3-NE1  
4Words  
16Words  
16Words  
16Words  
16Words  
----  
R3-  
R3-  
R3-  
R3-  
SV4 GC1  
NE1 PS1  
No module  
No module  
No module  
No module  
R3-NE1  
----  
1
2
3
4
5
6
7
8
R3-PS1  
R3-PS1  
----  
OUTPUT DATA  
INPUT DATA  
The !gure below shows the allocation of the data sent from  
the network module to the master.  
The !gure below shows the allocation of the data sent from  
the master to the network module.  
15  
0
15  
0
+
RWrn 0  
+
RWwn 0  
Module 1  
Module 2  
Module 1  
Module 2  
+
15  
+
15  
+
31  
+
31  
Module m  
Module m  
+
+
16 m1  
*
16 m1  
*
• The available data area for R3-GC1 is [16*m] (m=expanded cyclic setting)  
CC-Link Ver.1.10  
CC-Link Ver.2.00  
15  
15  
F E D C B A 9  
0
0
0
0
8
7
6
5
4
3
2
1
F E D C B A 9 8 7 6 5 4 3 2 1  
Module Status  
Module Status  
+
RX(n 0)  
+
RX(n 0)  
Unused  
Unused  
+
RX(n 7)  
Reserved Bits  
+
RX(n m 71)  
*
Reserved Bits  
R3-GC1 SPECIFICATIONS  
ES-8462 Rev.7 Page 4/6  
https://www.m-system.co.jp/  
MODEL: R3-GC1  
CC-Link Ver.1.10  
1. Module Status  
RX (n + 0) 0 indicates whether a virtual I/O module is specified or not.  
The virtual I/O module is a fixed one for CC-Link Ver.1.10, the related bit must be “1”.  
RX (n + 0) 0 Virtual I/O module 1  
2. RX (n + 1) to RX (n + 6) are not used.  
3. RX (n + 7) 0 to RX (n + 7) 7 is a reservation area.  
RX (n + 7) B is used as Ready signal, the bit is “1” when this module is in normal.  
RX (n + 7) 8 to A, C to F are not used.  
CC-Link Ver.2.00  
1. Module Status  
RX (n + 0) 0 to RX (n + 0) 7 indicates whether virtual I/O modules are specified or not.  
When a virtual module is specified, the related bit is “1”. When a virtual module is not specified, the related bit is “0”.  
The detailed information is as shown below.  
RX (n + 0) 0  
RX (n + 0) 1  
RX (n + 0) 2  
RX (n + 0) 3  
RX (n + 0) 4  
RX (n + 0) 5  
RX (n + 0) 6  
RX (n + 0) 7  
Virtual I/O module 1  
Virtual I/O module 2  
Virtual I/O module 3  
Virtual I/O module 4  
Virtual I/O module 5  
Virtual I/O module 6  
Virtual I/O module 7  
Virtual I/O module 8  
2. RX (n + 1) to RX (n + m * 7 – 2) are not used.  
3. RX (n + m * 7 – 1) 0 to RX (n + m * 7 – 1) 7 is a reservation area.  
RX (n + m * 7 – 1) B is used as Ready signal, the bit is “1” when this module is in normal.  
RX (n + m * 7 – 1) 8 to A, C to F are not used.  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]  
27.5 [1.08]  
109 [4.29]  
POSITIONING  
GUIDE  
6–M3  
SCREW  
1
4
2
5
3
6
TERMINAL  
COVER  
R3-GC1 SPECIFICATIONS  
ES-8462 Rev.7 Page 5/6  
https://www.m-system.co.jp/  
MODEL: R3-GC1  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
ROTARY SW  
LED  
Isolation  
Control  
Circuit  
Communication  
Circuit  
FG  
SLD  
DG  
DB  
INTERNAL BUS  
To Other  
CC-Link  
Devices  
DIP SW  
DA  
INTERNAL POWER  
1
4
RUN +  
RUN –  
RUN CONTACT OUTPUT  
2
3
5
6
CONFIGURATION JACK  
JACK  
SYSTEM CONFIGURATION EXAMPLES  
In the following system configuration, PC Recorder software captures the CC-Link data via R3-GC1 which is used as a gateway.  
PC Recorder software  
(Model: MSR128-V6)  
RS-232-C  
RS-232-C/RS-485 Converter  
(Model: R2K-1)  
CON  
FI  
G
B
RA  
TE  
RU  
N
ER  
R.1  
ER  
R.2  
RS-485  
R3- R3- R3-  
GC1 NM1 PS1  
CC-Link  
CC-Link  
Master Unit  
Specifications are subject to change without notice.  
R3-GC1 SPECIFICATIONS  
ES-8462 Rev.7 Page 6/6  
https://www.m-system.co.jp/  

相关型号:

R3-GC1S/CE

Remote I/O R3 Series CC-Link INTERFACE MODULE
MSYSTEM

R3-GC1S/Q

Remote I/O R3 Series CC-Link INTERFACE MODULE
MSYSTEM

R3-GD1

Remote I/O R3 Series DeviceNet INTERFACE MODULE
MSYSTEM

R3-GD1S/CE

Remote I/O R3 Series DeviceNet INTERFACE MODULE
MSYSTEM

R3-GD1S/Q

Remote I/O R3 Series DeviceNet INTERFACE MODULE
MSYSTEM

R3-GE1

Remote I/O R3 Series INTERFACE I/O MODULE
MSYSTEM

R3-GE1S

Remote I/O R3 Series INTERFACE I/O MODULE
MSYSTEM

R3-GE1S/CE

Remote I/O R3 Series INTERFACE I/O MODULE
MSYSTEM

R3-GE1S/Q

Remote I/O R3 Series INTERFACE I/O MODULE
MSYSTEM

R3-GFL1

Remote I/O R3 Series FL-net INTERFACE MODULE
MSYSTEM

R3-GFL1S

Remote I/O R3 Series FL-net INTERFACE MODULE
MSYSTEM

R3-GFL1S/CE

Remote I/O R3 Series FL-net INTERFACE MODULE
MSYSTEM