MODEL: R3-NF2  
Remote I/O R3 Series  
GENERAL SPECIFICATIONS  
Connection  
T-Link: Euro type connector terminal (applicable wire size:  
T-Link INTERFACE MODULE  
(Fuji Electric T-Link interface module equivalent)  
0.2 to 2.5 mm , stripped length 7 mm)  
2
Internal bus: Via the Installation Base  
27.5 (1.08)  
(model: R3-BSx)  
Internal power: Via the Installation Base (model: R3-BSx)  
Power input, RUN contact output: M3 separable screw  
terminal (torque 0.5 N·m)  
130  
(5.12)  
Screw terminal: Nickel-plated steel  
Isolation: T-Link to internal bus or internal power to power  
input to RUN contact output to FG  
119  
(4.69)  
mm (inch)  
Input error data setting: Input value setting at input module  
error with side DIP SW  
Dual communication setting: Set with the side DIP switch  
RUN indicator: Bi-color (green/red) LED; Green ON in normal  
communication; Red blinks when receiving data (Function  
selected with DIP SW)  
MODEL: R3–NF2–[1][2]  
ERR indicator: Bi-color (green/red) LED; Green ON in  
communication errors or minor failure, blinks at errors in the  
internal circuits; Red blinks when transmitting data  
(Function selected with DIP SW)  
ORDERING INFORMATION  
• Code number: R3-NF2-[1][2]  
Specify a code from below for each of [1] and [2].  
(e.g. R3-NF2-R/Q)  
RUN CONTACT OUTPUT  
• Specify the specification for option code /Q  
(e.g. /C01/SET)  
Rated load: 250 V AC @ 0.5 A (cos ø = 1)  
30 V DC @ 0.5 A (resistive load)  
Maximum switching voltage: 250 V AC or 30 V DC  
Maximum switching power: 250 VA or 150 W  
Minimum load: 1 V DC @ 1 mA  
[1] POWER INPUT  
N: No power supply  
Mechanical life: 2 × 10 cycles (rate 300 cycles/min.) When  
7
AC Power  
driving an inductive load, external contact protection and  
noise quenching recommended.  
K3: 100 – 120 V AC  
(Operational voltage range 85 - 132 V, 47 - 66 Hz) *  
L3: 200 – 240 V AC  
(Operational voltage range 170 - 264 V, 47 - 66 Hz) *  
DC Power  
T-Link SPECIFICATIONS  
Configuration: Multi-drop  
R: 24 V DC  
Communication: Half-duplex  
Baud rate: 500 kbps  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) *  
* Not selectable for use with independent power modules or  
network modules with the internal power input options.  
Max. transmission data capacity: 117 words for input, 125  
words for output  
Node address: Rotary switch; 00 – 99  
Transmission media/distance:  
[2] OPTIONS  
blank: none  
KPEV-SB, 0.75 mm  
2
× 1 pair, 700 m  
× 1 pair, 1000 m  
T-KPEV-SB, 1.25 mm  
2
/Q: With options (specify the specification)  
INSTALLATION  
Power consumption  
AC: Approx. 20 VA  
DC: Approx. 12 W  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
Current consumption (no power supply): 120 mA  
Output current (power supply): 230 mA continuous at 20 V  
DC; 380 mA for 10 minutes  
/C03: Rubber coating  
EX-FACTORY SETTING  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-8438)  
Operating temperature: -10 to +55°C (14 to 131°F)  
R3-NF2 SPECIFICATIONS  
ES-8438 Rev.4 Page 1/5  
http://www.m-system.co.jp/  
MODEL: R3-NF2  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: Installation Base (model: R3-BSx)  
Weight: 200 g (0.44 lb)  
PERFORMANCE  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute (T-Link to  
internal bus or internal power to power input to RUN contact  
output to FG)  
EXTERNAL VIEW  
FRONT VIEW  
SIDE VIEW  
Node Address Setting  
Rotary SW (MSB)  
SA1  
SA2  
RUN LED  
Node Address Setting  
Rotary SW (LSB)  
ERR LED  
Functions  
SW3  
RT+  
RT–  
SD  
T2  
Configuration Jack  
Euro Type  
Connector Terminal  
4
3
2
1
T1  
1
2
3
4
5
6
ON  
TRANSMISSION DATA DESCRIPTIONS  
This module allocates T-link addresses in order from slot 1. Set the begin address to the module’s node address (T-Link address.)  
For example; if the formation of the I/O modules is: slot 1: R3-SV4, slot 2: R3-YV4, slot 3: R3-DA16 and slot 4: R3-DC16, the I/O  
data is assigned as detailed on the table below. Set “10” to the module address. Discrete I/O data can be also represented with  
bit address. Ch.1 through 16 are assigned to 0 thr. F.  
SLOT  
1
MODULE  
R3-SV4  
ADDRESS  
10  
WORD ADDRESS CONTENTS  
0
1
2
3
0
1
2
3
0
0
CH1 input data  
CH2 input data  
CH3 input data  
CH4 input data  
CH1 output data  
CH2 output data  
CH3 output data  
CH4 output data  
Input data  
2
R3-YV4  
11  
3
4
R3-DA16  
R3-DC16  
12  
13  
Output data  
R3-NF2 SPECIFICATIONS  
ES-8438 Rev.4 Page 2/5  
http://www.m-system.co.jp/  
MODEL: R3-NF2  
I/O DATA DESCRIPTIONS  
The data allocations for typical I/O modules are shown below.  
Refer to the manual for each module for detailed data allocations.  
■ ANALOG DATA (16-bit data, models: R3-SV4, YV4, DS4, YS4, US4, etc.)  
16-bit binary data.  
Basically, 0 to 100% of the selected I/O range is converted into 0 to 10000 (binary).  
-15 to 0 % is a negative range represented in 2’s complement.  
In case of R3-US4, -10 to 0% is a negative range represented in 2's complement.  
15  
0
■ TEMPERATURE DATA (16-bit data, models: R3-RS4, TS4, US4, etc.)  
16-bit binary data.  
With °C temperature unit, raw data is multiplied by 10. For example, 25.5°C is converted into 255.  
With °F temperature unit, the integer section of raw data is directly converted into the data.  
For example, 135.4°F is converted into 135.  
Minus temperature is converted into negative values, represented in 2’s complements.  
15  
0
■ ANALOG DATA (16-bit data, models: R3-CT4A, CT4B, etc.)  
16-bit binary data.  
Integer obtained by multiplying unit value (A) by 100.  
In case of CLSE-R5, integer obtained by multiplying unit value (A) by 1000.  
15  
0
■ ACCUMULATED COUNT DATA (32-bit data, models: R3-PA2, PA4A, WT1, WT4, etc.)  
32-bit binary data is used for accumulated counts and encoder positions.  
Lower 16 bits are allocated from the lowest address to higher ones, higher 16 bits in turn.  
15  
0
0
+0  
+1  
Lower 16 bits  
Higher 16 bits  
15  
■ BCD DATA (32-bit data, models: R3-BA32A, BC32A, etc.)  
32-bit binary data is used for BCD.  
Lower 16 bits are allocated from the lowest address to higher ones, higher 16 bits in turn.  
15  
15  
0
+0  
+1  
Lower 16 bits  
Higher 16 bits  
0
R3-NF2 SPECIFICATIONS  
ES-8438 Rev.4 Page 3/5  
http://www.m-system.co.jp/  
MODEL: R3-NF2  
■ 16-POINT DISCRETE DATA (models: R3-DA16, DC16, etc.)  
15  
0
Input 1 (Output 1)  
Input 2 (Output 2)  
Input 3 (Output 3)  
:
:
Input 16 (Output 16)  
0 : OFF  
1 : ON  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
10 (.39)  
27.5 (1.08)  
109 (4.29)  
POSITIONING  
GUIDE  
6–M3  
SCREW  
1
4
2
5
3
TERMINAL  
COVER  
6
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
LED Rotary SW  
Isolation  
RT+  
RT–  
SD  
T2  
Control  
Circuit  
Communication  
Circuit  
Close to terminate.*  
INTERNAL BUS  
Shielded Twisted-pair  
Cable  
To Other  
T-Link  
Devices  
Term. Resist.  
DIP SW  
+
T1  
INTERNAL POWER  
RUN +  
RUN –  
U (+)  
1
4
2
3
6
RUN CONTACT OUTPUT  
5
**  
**  
POWER INPUT  
V (–)  
**  
FG  
JACK  
CONFIGURATION JACK  
* When the module is at an end of the transmission line via twisted-pair calbe  
(= when there is no cross wiring), close across the RT+ and RT– terminals with the  
jumper included in the product package. Remove the jumper for all other locations.  
**Not provided with ‘No Power Supply’ type module.  
Caution: FG terminal is NOT a protective conductor terminal.  
R3-NF2 SPECIFICATIONS  
ES-8438 Rev.4 Page 4/5  
http://www.m-system.co.jp/  
MODEL: R3-NF2  
Specifications are subject to change without notice.  
R3-NF2 SPECIFICATIONS  
ES-8438 Rev.4 Page 5/5  
http://www.m-system.co.jp/  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY