R3-PA4W [MSYSTEM]

Remote I/O R3 Series HIGH SPEED PULSE INPUT MODULE;
R3-PA4W
型号: R3-PA4W
厂家: M-SYSTEM    M-SYSTEM
描述:

Remote I/O R3 Series HIGH SPEED PULSE INPUT MODULE

输入元件
文件: 总5页 (文件大小:128K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: R3-PA4  
Internal power: Via the Installation Base (model: R3-BSx)  
Screw terminal: Nickel-plated steel  
Remote I/O R3 Series  
Isolation: Input 1 to input 2 to input 3 to input 4 to internal  
bus or internal power  
HIGH SPEED PULSE INPUT MODULE  
(4 points, isolated)  
Input range & gain: Selectable with the side DIP SW  
RUN indicator: Bi-color (red/green) LED;  
Red when the bus A operates normally;  
Green when the bus B operates normally;  
Amber when both buses operate normally.  
ERR indicator: Bi-color (red/green) LED;  
Red with input abnormality;  
27.5 (1.08)  
130  
(5.12)  
Green in normal operating conditions.  
Low-end cutout: 0.1 %  
109  
(4.29)  
mm (inch)  
INPUT SPECIFICATIONS  
Sensor Excitation  
MODEL: R3–PA4[1][2]  
Voltage: 12 V DC ±10 %  
Current: 15 mA  
Current limiting circuit: Approx. 30 mA  
INPUT RANGE: 0 – 100 kHz, 0 – 10 kHz, 0 – 1 kHz, 0 – 100  
Hz, 0 – 10 Hz, 0 – 1 Hz, 0 – 0.1 Hz  
ORDERING INFORMATION  
• Code number: R3-PA4[1][2]  
Specify a code from below for each of [1] and [2].  
(e.g. R3-PA4W/Q)  
Minimum pulse width requirement: 5 μsec. for both ON and  
OFF  
• Specify the specification for option code /Q  
(e.g. /C01/SET)  
DETECTING LEVEL  
Detecting level: 15 – 100 %  
(of operational voltage range across the terminals)  
Factory setting: 50 % (programmable using the R3CON PC  
Configurator software)  
NO. OF CHANNELS  
4: 4  
Note 1. Each channel has three sets of input terminals.  
Input terminal 1: 2 – 5, 7 – 10, 12 – 15, 17 – 20  
Input terminal 2: 3 – 5, 8 – 10, 13 – 15, 18 – 20  
Input terminal 3: 4 – 5, 9 – 10, 14 – 15, 19 – 20  
Note 2. Gain 1 or Gain 2 selectable with the side DIP SW.  
Note 3. Measured as 0 % below 15 % of the range.  
Open Collector (input terminal 3, gain 1)  
Sensor excitation: 12 V DC  
[1] COMMUNICATION MODE  
S: Single  
W: Dual  
[2] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
Pull-up resistance: 20 kΩ (shorted across 1 – 3, 6 – 8, 11 –  
13, 16 – 18 respectively)  
ON voltage: ≤ 1.5 V (≤ 2 kΩ recommended)  
OFF voltage: ≥ 2.5 V (≥ 20 kΩ recommended)  
(Set detecting level 50 % when the saturation voltage is not  
greater than 0.8 V, set 70 % when the saturation voltage is  
between 0.8 to 1.5 V.)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
/C03: Rubber coating  
Voltage Pulse (input terminals 1 and 2)  
Waveform: Square, sine or similar waveforms  
Input impedance: 100 kΩ minimum at input terminal 1  
20 kΩ minimum at input terminal 2  
EX-FACTORY SETTING  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-8399)  
Operational voltage across the terminals:  
0 – 50 V (input terminal 1, gain 1)  
GENERAL SPECIFICATIONS  
Connection  
0 – 25 V (input terminal 1, gain 2)  
Internal bus: Via the Installation Base (model: R3-BSx)  
Input: M3 separable screw terminal (torque 0.5 N·m)  
0 – 12 V (input terminal 2, gain 1)  
0 – 6 V (input terminal 2, gain 2)  
R3-PA4 SPECIFICATIONS  
ES-8399 Rev.8 Page 1/5  
http://www.m-system.co.jp/  
MODEL: R3-PA4  
Threshold: Pulse logic is detected by comparing input pulse  
voltage and the detecting level. Detecting ‘Rise’ or ‘Sink’  
can be switched by using the R3CON PC Configurator  
software; factory setting ‘Rise’)  
INSTALLATION  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: Installation Base (model: R3-BSx)  
Weight: 100 g (0.22 lb)  
PERFORMANCE  
Conversion accuracy: ±0.1 %  
Data range: 0 – 10000 of the input range  
Data allocation: 4  
Current consumption:  
80 mA (with no load at the sensor excitation)  
130 mA (15 mA at each excitation)  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute (input 1 to input  
2 to input 3 to input 4 to internal bus or internal power)  
2000 V AC @ 1 minute (power input to FG; isolated on the  
power supply module)  
EXTERNAL VIEW  
FRONT VIEW  
SIDE VIEW  
RUN LED  
ERR LED  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
SW3  
ON  
SW2  
SW1  
Range  
4
3
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
Input 2 (SW1)  
or  
Input 4 (SW2)  
Gain  
Input 1 (SW1)  
or  
Input 3 (SW2)  
ON  
ON  
R3-PA4 SPECIFICATIONS  
ES-8399 Rev.8 Page 2/5  
http://www.m-system.co.jp/  
MODEL: R3-PA4  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
27.5 (1.08)  
109 (4.29)  
POSITIONING  
GUIDE  
1
11  
2
20–M3  
SCREW  
12  
3
13  
4
14  
5
15  
6
16  
7
17  
8
18  
9
19  
10  
20  
TERMINAL  
COVER  
R3-PA4 SPECIFICATIONS  
ES-8399 Rev.8 Page 3/5  
http://www.m-system.co.jp/  
MODEL: R3-PA4  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
RUN LED ERR LED DIP SW  
Isolation  
INTERNAL BUS A  
Sensor  
Excitation  
Communication  
Circuit  
EXC +  
1
INTERNAL BUS B*  
Input  
Circuit  
INP TERM. 1  
INP TERM. 2  
INP TERM. 3  
COM  
2
3
4
5
6
Input 1  
INTERNAL POWER  
Isolation  
Isolation  
Isolation  
Sensor  
Excitation  
EXC +  
Input  
Circuit  
INP TERM. 1  
INP TERM. 2  
INP TERM. 3  
7
8
9
Input 2  
Control  
Circuit  
COM 10  
Sensor  
Excitation  
EXC + 11  
Input  
Circuit  
INP TERM. 1 12  
INP TERM. 2 13  
INP TERM. 3 14  
COM 15  
Input 3  
Sensor  
Excitation  
EXC + 16  
Input  
Circuit  
INP TERM. 1 17  
INP TERM. 2 18  
INP TERM. 3 19  
COM 20  
Input 4  
*For dual redundant communication.  
Input Connection Example (Input 1)  
Open Collector  
1
2
3
4
5
12V DC  
20kΩ  
1kΩ  
7.5kΩ  
Voltage Pulse input  
• Operational voltage across the terminals: 0 − 50V, 0 − 25V  
• Operational voltage across the terminals: 0 − 12V0 − 6V  
+
+
1
2
3
4
5
+
+
1
2
3
4
5
100kΩ  
20kΩ  
1kΩ  
100kΩ  
20kΩ  
1kΩ  
12V DC  
12V DC  
PWR  
PWR  
7.5kΩ  
7.5kΩ  
R3-PA4 SPECIFICATIONS  
ES-8399 Rev.8 Page 4/5  
http://www.m-system.co.jp/  
MODEL: R3-PA4  
Specifications are subject to change without notice.  
R3-PA4 SPECIFICATIONS  
ES-8399 Rev.8 Page 5/5  
http://www.m-system.co.jp/  

相关型号:

R3-PA4W/Q

Remote I/O R3 Series HIGH SPEED PULSE INPUT MODULE
MSYSTEM

R3-PA8

Remote I/O R3 Series TOTALIZED PULSE INPUT MODULE
MSYSTEM

R3-PA8S

Remote I/O R3 Series TOTALIZED PULSE INPUT MODULE
MSYSTEM

R3-PA8S/A

Remote I/O R3 Series TOTALIZED PULSE INPUT MODULE
MSYSTEM

R3-PA8S/CE

Remote I/O R3 Series TOTALIZED PULSE INPUT MODULE
MSYSTEM

R3-PA8S/Q

Remote I/O R3 Series TOTALIZED PULSE INPUT MODULE
MSYSTEM

R3-PA8W

Remote I/O R3 Series TOTALIZED PULSE INPUT MODULE
MSYSTEM

R3-PA8W/A

Remote I/O R3 Series TOTALIZED PULSE INPUT MODULE
MSYSTEM

R3-PA8W/CE

Remote I/O R3 Series TOTALIZED PULSE INPUT MODULE
MSYSTEM

R3-PA8W/Q

Remote I/O R3 Series TOTALIZED PULSE INPUT MODULE
MSYSTEM

R3-PAAAS

Remote I/O R3 Series HIGH SPEED TOTALIZED PULSE INPUT MODULE
MSYSTEM

R3-PAAAS/Q

Remote I/O R3 Series HIGH SPEED TOTALIZED PULSE INPUT MODULE
MSYSTEM