MODEL: R3-PC16A
Remote I/O R3 Series
GENERAL SPECIFICATIONS
Connection
Internal bus: Via the Installation Base (model: R3-BSx)
Output: M3 separable screw terminal (torque 0.5 N·m)
Internal power: Via the Installation Base (model: R3-BSx)
Screw terminal: Nickel-plated steel
PULSE OUTPUT MODULE
(open collector output, 16 points)
27.5 [1.08]
Isolation: Output to internal bus or internal power
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with external power supply abnormality;
Green in normal operating conditions.
Output status indicator: Red LED; turns on with the output
ON.
130
[5.12]
109
[4.29]
mm [inch]
Pulse width adjustment: Side DIP SW
MODEL: R3-PC16A[1][2]
OUTPUT SPECIFICATIONS
Output: Open collector, 16 points
ORDERING INFORMATION
• Code number: R3-PC16A[1][2]
Specify a code from below for each of [1] and [2].
(e.g. R3-PC16AW/CE/Q)
Max. frequency: 100 Hz (selectable with DIP SW)
Max. ouptut pulse number per setting: 2000
(No output when a number greater than 2000 is set.)
Totalized pulse range: 1 – 10000 (‘0’ at reset only)
Max. pulse range selectable from 1 to 65535 using the
R3CON PC Configurator Software. Refer to the R3CON Users
Manual for detailed information.
• Specify the specification for option code /Q
(e.g. /C01)
NO. OF CHANNELS
Count at overflow: Reset and restart at ‘1.’
Rated load voltage: 24 V DC ±10 %
16: 16
Maximum load current: 0.1 A per point
OUTPUT
A: Open collector
Maximum rush current: 0.5 A for max. 10 msec.
Maximum leak current at OFF: 0.1 mA
Maximum voltage drop at ON: 0.1 V DC typical; 1.2 V DC
max.
[1] COMMUNICATION MODE
S: Single
Common: All 16 points (2 terminals)
W: Dual
Common current: Max. 1.6 A per common
External power supply: 24 V DC ±10 % approx. 0.02 A
[2] OPTIONS (multiple selections)
Standards & Approvals
blank: Without CE
INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R3-BSx)
Weight: 200 g (0.44 lb)
/CE: CE marking
Other Options
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
PERFORMANCE
Data allocation: 16
Current consumption: Approx. 100 mA
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute
(output to internal bus or internal power)
/C02: Polyurethane coating
/C03: Rubber coating
R3-PC16A SPECIFICATIONS
ES-8408 Rev.10 Page 1/4
https://www.m-system.co.jp/
MODEL: R3-PC16A
2000 V AC @ 1 minute (power input to FG; isolated on the
power supply module)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
FUNCTIONS
■ MANUAL COUNT RESET
1) Remove Network Module or its cables and interrupt
communication with other devices.
2) Turn ON the Count Reset SW (SW3-1).
3) Return the module to the base and turn the power supply
on.
4) ERR LED turns on and the module starts resetting its
counter. When the resetting is complete, the LED turns to
green. DO NOT remove the power while the red LED is on.
The RUN LED starts blinking at the same time.
5) After the green LED is confirmed, turn the power supply
off.
6) Turn OFF the Count Reset SW (SW3-1).
7) Return the Network module onto the base and turn the
power supply on.
Note: Count Reset SW must be turned OFF after this
procedure because the module does not start counting with
ON state.
EXTERNAL VIEW
■ FRONT VIEW
■ SIDE VIEW
RUN LED
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Status Indicator LED
ERR LED
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
SW3
ON
SW2
SW1
4
3
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
OFF
Width
Count
Reset
ON
Width
ON
ON
Count Reset SW must be turned off during operation.
R3-PC16A SPECIFICATIONS
ES-8408 Rev.10 Page 2/4
https://www.m-system.co.jp/
MODEL: R3-PC16A
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
27.5 [1.08]
109 [4.29]
POSITIONING
GUIDE
1
11
2
20–M3
SCREW
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
TERMINAL
COVER
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
STATUS
RUN LED ERR LED INDICATOR LED
Output Circuit
1
INTERNAL BUS A
Communication
Circuit
Control
Circuit
1
2
Po 1
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
*INTERNAL BUS B
2
Po 2
3
DIP SW
3
Po 3
4
4
INTERNAL POWER
Po 4
5
5
Po 5
6
6
Po 6
7
7
Po 7
8
8
Po 8
9
11
12
13
14
15
16
17
18
9
Po 9
10
11
12
13
14
15
16
+24V
Po 10
Po 11
Po 12
Po 13
Po 14
Po 15
Po 16
24VDC
24VDC
COM
COM
19
10
20
24VDC
Numbers in italic indicate LED No.s assigned to the front panel LEDs.
*For dual redundant communication.
R3-PC16A SPECIFICATIONS
ES-8408 Rev.10 Page 3/4
https://www.m-system.co.jp/
MODEL: R3-PC16A
Specifications are subject to change without notice.
R3-PC16A SPECIFICATIONS
ES-8408 Rev.10 Page 4/4
https://www.m-system.co.jp/