R30PA2 [MSYSTEM]

Remote I/O R30 Series TOTALIZED PULSE INPUT MODULE;
R30PA2
型号: R30PA2
厂家: M-SYSTEM    M-SYSTEM
描述:

Remote I/O R30 Series TOTALIZED PULSE INPUT MODULE

输入元件
文件: 总5页 (文件大小:235K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: R30PA2  
Remote I/O R30 Series  
RELATED PRODUCTS  
• Interface module  
Model: R30NECT1 (firmware version V1.04.10 or higher)  
Model: R30NCIE1 (firmware version V1.01.13 or higher)  
• Paperless recorder  
TOTALIZED PULSE INPUT MODULE  
(Pi 2 points, 32 Bits)  
Functions & Features  
Model: TR30 (firmware version V1.05 or higher)  
• PC configurator software (model: R30CFG)  
Downloadable at M-System’s web site.  
For connecting to PC, use commercially available Mini-B  
type USB cable. (provided by user)  
• Space-saving remote I/O module of 2 points input pulse  
counter  
• 32-bit binary data  
25 [.98]  
GENERAL SPECIFICATIONS  
Connection  
110  
[4.33]  
Internal bus: Via the Installation Base (model: R30BS)  
Input: M3 separable screw terminal (torque 0.5 N·m)  
Internal power: Via the Installation Base (model: R30BS)  
Solderless terminal: Refer to the drawing at the end of the  
section.  
98  
[3.86]  
Recommended manufacturer: Japan Solderless Terminal  
MFG. Co., Ltd., Nichifu Co., Ltd.  
mm [inch]  
(Solderless terminals with insulation sleeve do not fit.)  
Applicable wire size: 0.25 to 0.75 mm  
2
MODEL: R30PA2S[1]  
Screw terminal: Nickel-plated steel  
Isolation: Input or reset input or external power to internal  
bus or internal power  
ORDERING INFORMATION  
• Code number: R30PA2S[1]  
Specify a code from below for [1].  
(e.g. R30PA2S/Q)  
Status indicator LEDs: RUN, ERR  
Input status indicator LEDs: Green LED; turns on with input  
ON  
(Refer to the instruction manual.)  
• Specify the specification for option code /Q  
(e.g. /C01/SET)  
Count reset: by inputting one pulse to the reset input  
terminal, or from host PC/PLC  
Count preset: settable from host PC/PLC, or with PC  
configurator software  
NO. OF CHANNELS  
2: 2  
■Recommended solderless terminal size - M3 (unit: mm)  
3 max.  
COMMUNICATION MODE  
3.2 dia.  
S: Single  
[1] OPTIONS  
Other Options  
12 max.  
blank: none  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
/C03: Rubber coating  
EX-FACTORY SETTING  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-9022)  
R30PA2 SPECIFICATIONS  
ES-9022 Rev.2 Page 1/5  
https://www.m-system.co.jp/  
MODEL: R30PA2  
INPUT SPECIFICATIONS  
Module type: Pulse input, 2 points  
Common: Positive or negative common (NPN/PNP), common  
per 2 points  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
RoHS Directive  
Contact Input / Reset Input  
Open collector input (NPN, PNP)  
Rated input voltage: 24 V DC ±10 %; ripple 5 %p-p max.  
ON voltage/current: ≥ 16 V DC (input to common) /  
≥ 3.7 mA  
OFF voltage/current: ≤ 5 V DC (input to common) / ≤ 1 mA  
Voltage Pulse Input  
ON voltage/current: ≥ 16 V DC (input to common) /  
≥ 3.7 mA  
OFF voltage/current: ≤ 5 V DC (input to common) / ≤ 1 mA  
Input current: ≤ 5.5 mA per point at 24 V DC  
Input resistance: Approx. 4.4 kΩ  
ON delay: ≤ 2.0 msec.  
OFF delay: ≤ 2.0 msec.  
Max input frequency: 100 Hz  
Minimum pulse width time requirement: 5 msec. (for both  
ON and OFF)  
Totalized pulse range: 0 to 4,294,967,295 (0 only when the  
counter is reset)  
Max pulse range: 1 to 4,294,967,295  
(factory setting: 4,294,967,295)  
Count at overflow: 0 or 1 (factory setting: 0)  
INSTALLATION  
Current consumption: 30 mA max.  
Operating temperature: -10 to +55°C (14 to 131°F)  
Storage temperature: -20 to +65°C (-4 to +149°F)  
Operating humidity: 10 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: Installation Base (model: R30BS)  
Weight: 150 g (0.33 lb)  
PERFORMANCE  
Data allocation: 4  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute  
(input or reset input or external power to internal bus or  
internal power)  
1500 V AC @ 1 minute (power to FG; isolated on the power  
supply module)  
R30PA2 SPECIFICATIONS  
ES-9022 Rev.2 Page 2/5  
https://www.m-system.co.jp/  
MODEL: R30PA2  
CONFIGURATOR SOFTWARE SETTING  
The following parameters can be set with using PC Configurator Software (model: R30CFG)  
Refer to the users manual for the R30CFG for detailed operation of the software program.  
CHANNEL INDIVIDUAL SETTING  
PARAMETER  
SETTING RANGE  
1 – 4,294,967,295  
DEFAULT SETTING  
4,294,967,295  
Max no. of totalized pulse  
Count at overow  
(value to which the count returns)  
0
1
0
Preset value  
0 – Max no. of totalized pulse  
SETTING RANGE  
0
CHANNEL BATCH SETTING  
PARAMETER  
DEFAULT SETTING  
Count pulse edge  
Falling edge (DI-ON)/  
Rising edge (DI-OFF)  
Falling edge (DI-ON)  
External reset pulse edge to detect Falling edge (DI-ON)/  
Rising edge (DI-OFF)  
Falling edge (DI-ON)  
External reset detection  
Reset/preset from host PC/PLC  
Simulate input  
Enable/Disable  
Disable  
Enable/Disable  
Disable  
Normal input/Simulate input  
Normal input  
EXTERNAL VIEW  
FRONT VIEW  
SIDE VIEW  
Positioning Guide  
Specifications  
RUN LED  
1
2
RUN  
ERR  
Input Status Indicator LED  
R
ERR LED  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
Input Terminal  
Block  
Terminal Fixing  
Screw  
Terminal Cover  
BOTTOM VIEW  
Base Fixing Screw  
Lock Tab  
R30PA2 SPECIFICATIONS  
ES-9022 Rev.2 Page 3/5  
https://www.m-system.co.jp/  
MODEL: R30PA2  
TERMINAL ASSIGNMENTS  
1
No. ID  
Function  
PI1 Input 1  
PI2 Input 2  
No. ID  
Function  
PI1  
11  
C1  
12  
C2  
13  
NC  
14  
NC  
15  
NC  
16  
NC  
17  
NC  
18  
NC  
1
2
3
4
5
6
7
8
9
11 C1 Common  
2
12 C2 Common  
PI2  
3
NC No connection  
NC No connection  
NC No connection  
NC No connection  
NC No connection  
NC No connection  
RST+ Reset input (+)  
13 NC No connection  
14 NC No connection  
15 NC No connection  
16 NC No connection  
17 NC No connection  
18 NC No connection  
19 RST– Reset input (–)  
NC  
4
NC  
5
NC  
6
NC  
7
NC  
10 V+ External Excitation (+) 20  
V
External Excitation (–)  
8
NC  
9
RST+  
19  
RST–  
10  
V+  
20  
V–  
DATA ALLOCATION  
ADDRESS  
CONTENTS  
+0  
+1  
+2  
+3  
Input 1 totalized value (lower 16 bits)  
Input 1 totalized value (upper 16 bits)  
Input 2 totalized value (lower 16 bits)  
Input 2 totalized value (upper 16 bits)  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]  
25 [.98]  
98 [3.86]  
20–M3  
SCREW  
R30PA2 SPECIFICATIONS  
ES-9022 Rev.2 Page 4/5  
https://www.m-system.co.jp/  
MODEL: R30PA2  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
EXTERNAL  
EXCITATION  
Specifications are subject to change without notice.  
R30PA2 SPECIFICATIONS  
ES-9022 Rev.2 Page 5/5  
https://www.m-system.co.jp/  

相关型号:

R30PA2S

Remote I/O R30 Series TOTALIZED PULSE INPUT MODULE
MSYSTEM

R30PA2S/Q

Remote I/O R30 Series TOTALIZED PULSE INPUT MODULE
MSYSTEM

R30R090

Radial Leaded PTC
LITTELFUSE

R30R110

Radial Leaded PTC
LITTELFUSE

R30R135

Radial Leaded PTC
LITTELFUSE

R30R160

Radial Leaded PTC
LITTELFUSE

R30R185

Radial Leaded PTC
LITTELFUSE

R30R250

Radial Leaded PTC
LITTELFUSE

R30R300

Radial Leaded PTC
LITTELFUSE

R30R400

Radial Leaded PTC
LITTELFUSE

R30SV4

Remote I/O R30 Series DC VOLTAGE/CURRENT INPUT MODULE
MSYSTEM

R30SV4S

Remote I/O R30 Series DC VOLTAGE/CURRENT INPUT MODULE
MSYSTEM