MODEL: R3Y-PA16
/C03: Rubber coating
Remote I/O R3 Series
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
(No. ESU-8389)
TOTALIZED PULSE INPUT MODULE
(Pi 16 points, connector type)
27.5 [1.08]
RELATED PRODUCTS
• Connector terminal block (model: CNT)
• Special cable with 40-pin connector (model: FCN)
• Interface module (model: R3-NC1, R3-NC3, R3-NE1,
R3-NM1, R3-NDx, R3-NFL1, R3-NP1, R3-NFx, R3-NML3.
R3-NF2: Firmware version V0.05 or later)
Note:
130
[5.12]
109
[4.29]
• Count reset by host PC/PLC:
mm [inch]
Available with this unit and the above mentioned interface
modules of firmware version V2.00 or later, except R3-NFx.
Notice that Count reset by host PC/PLC via R3-NFx or
interface module of previous versions of firmware is unable.
• Count preset by host PC/PLC:
MODEL: R3Y–PA16[1][2]
ORDERING INFORMATION
• Code number: R3Y-PA16[1][2]
Specify a code from below for each of [1] and [2].
(e.g. R3Y-PA16W/A/CE/PRS/Q)
It is only available in combination with this unit displayed
'SW3-4 RESET/PRESET' on the right side panel and the
interface module R3-NM1 or R3-NE1 of firmware version
V2.00 or later. Count preset is not available for other
combination.
• Specify the specification for option code /Q
(e.g. /C01/SET)
Notice that this function is not available in the same time as
count preset by host PC/PLC.
NO. OF CHANNELS
16: 16
GENERAL SPECIFICATIONS
Connection
Internal bus: Via the Installation Base (model: R3-BSx)
Input: 40-pin connector (Fujitsu Model FCN-365P040-AU)
Internal power: Via the Installation Base (model: R3-BSx)
Isolation: Input to internal bus or internal power
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with excitation abnormality;
[1] COMMUNICATION MODE
S: Single
W: Dual
[2] OPTIONS (multiple selections)
Excitation
Blank: Internal (negative common)
/A: External (24 V DC, negative common)
Standards & Approvals
blank: Without CE
Green in normal operating conditions.
/CE: CE marking
Input status indicator: Red LED; turns on with the input ON.
Count reset: Via DIP switch on the side or one pulse to reset
input
EX-FACTORY SETTING
blank: Enable count reset by host PC/PLC
/PRS: Enable count preset by host PC/PLC
Other Options
Count setting from host PC/PLC: Count reset/count preset is
changeable via DIP switch on the side.
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
R3Y-PA16 SPECIFICATIONS
ES-8962 Rev.7 Page 1/6
https://www.m-system.co.jp/
MODEL: R3Y-PA16
INPUT SPECIFICATIONS
FUNCTIONS
Number of input: 16 points
■ MANUAL COUNT RESET
Input resistance: 6 kΩ
1) Remove Network Module or its cables and interrupt
communication with other devices.
Common: Negative commons, all points
Maximum frequency: 100 Hz (ON/OFF time ≥ 5 msec.)
This unit is designed to be able to accept a frequency up to
100 Hz, however, ‘chattering’ contact must be avoided for
accurate measuring of such high frequency. Use mercury
relays or similar ones that do not cause any chattering.
Totalized pulse range: 1 – 10000 (‘0’ at reset)
Max. pulse range selectable from 1 to 65535 using the
R3CON PC Configurator Software. Refer to the R3CON Users
Manual for detailed information.
2) Turn ON the Count Reset SW (SW3-1).
3) Return the module to the base and turn the power supply
on.
4) ERR LED turns on and the module starts resetting its
counter. When the resetting is complete, the LED turns to
green. DO NOT remove the power while the red LED is
on.The RUN LED starts blinking at the same time.
5) After the green LED is confirmed, turn the power supply
off.
Count at overflow: Reset and restart at ‘1.’
■ R3Y-PA16x (internal excitation)
6) Turn OFF the Count Reset SW (SW3-1).
7) Return the Network module onto the base and turn the
power supply on.
Sensing voltage: 13 V DC (max. 24 V with no load)
ON current: ≥ 1.5 mA (≤ 1.5 kΩ)
Note: Count Reset SW must be turned OFF after this
procedure because the module does not start counting with
ON state.
OFF current: ≤ 0.75 mA (≥ 18 kΩ)
■ R3Y-PA16x/A (external excitation)
Sensing voltage: 24 V DC
■ REMOTE COUNT RESET INPUT
ON current: ≥ 1.5 mA (≤ 12 kΩ)
With the Count Reset Input SW (SW3-3) turned ON, the
count reset signal value becomes effective.
SW3-3 = OFF: unused
OFF current: ≤ 0.75 mA (≥ 36 kΩ)
SW3-3 = ON: reset signal.
INSTALLATION
One pulse supplied at the Count reset input terminal will be
recognized as a reset signal.
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R3-BSx)
Weight: 200 g (0.44 lb)
■ REMOTE COUNT RESET OPERATION
1) ERR LED turns on (red color) when the reset signal is
received.
2) In 1 second, the module starts resetting its counter.
When the resetting is complete, the LED turns to green.
3) After 1 second, ERR LED turns back to the state before
the reset signal has been received.
PERFORMANCE
Data allocation: 16
Current consumption:
Note: Reset signals received while the module is processing
(1) through (3) are ignored.
R3Y-PA16x: 100 mA
R3Y-PA16x/A: 80 mA
■ COUNT RESET FROM HOST PC/PLC
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute
(input to internal bus or internal power)
2000 V AC @ 1 minute (power input to FG; isolated on the
power supply module)
Refer to “COUNTER SETTING FROM HOST PC/PLC” section
hereafter.
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
R3Y-PA16 SPECIFICATIONS
ES-8962 Rev.7 Page 2/6
https://www.m-system.co.jp/
MODEL: R3Y-PA16
EXTERNAL VIEW
■FRONT VIEW
■SIDE VIEW
RUN LED
ERR LED
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Input Status Indicator LEDs
• Pin Assignment
Functions
B A
20 20
Input Connector
SW3
Count Setting
from Host PC/PLC
4
Count Reset Input
3
2
1
Count Reset
ON
Set the Count Reset SW to OFF to start counting.
B
A
1
1
R3Y-PA16 SPECIFICATIONS
ES-8962 Rev.7 Page 3/6
https://www.m-system.co.jp/
MODEL: R3Y-PA16
COUNTER SETTING FROM HOST PC/PLC
■ COUNTER RESET
(Available for R3-NC1, R3-NC3, R3-NE1, R3-NM1, R3-NDx, R3-NFL1, R3-NP1, R3-NML3 (Firmware version 2.00 or later))
Setting SW3-4 OFF and turning power on enable the function.
The bits indicating the channels to reset counter are allocated in the rst word from host PC/PLC.
When these bits are changed from 0 to 1, the counter is reset. When it is conrmed that the counter is reset, return to 0.
Notice that if the bit remains at 1, the next reset will not work.
15
0
Count reset CH.1
Count reset CH.2
Count reset CH.3
Count reset CH.4
Count reset CH.16
■ COUNTER PRESET
(Available in combination with R3-NE1, R3-NM1 (Firmware version 2.00 or later), and R3Y-PA16 displayed ‘SW3-4 RESET/PRESET’
on the right side)
Setting SW3-4 ON and turning power on enable the function.
Write the preset value to the Holding Resisters, which has same address as the Input Resisters.
• Input Resisters
• Holding Resisters
Address
n+0
Address
n+0
Preset value of Input 1
Preset value of Input 2
Preset value of Input 3
Preset value of Input 4
Input 1
Input 2
Input 3
n+1
n+1
n+2
n+2
n+3
Input 4
n+3
n+14
n+15
n+14
n+15
Preset value of Input 15
Preset value of Input 16
Input 15
Input 16
R3Y-PA16 SPECIFICATIONS
ES-8962 Rev.7 Page 4/6
https://www.m-system.co.jp/
MODEL: R3Y-PA16
EXTERNAL DIMENSIONS unit: mm [inch]
27.5 [1.08]
109 [4.29]
POSITIONING
GUIDE
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
■ INTERNAL POWER
■ EXTERNAL EXCITATION (OPTION /A)
STATUS
RUN LED ERR LED INDICATOR LED
Input Circuit
Input Circuit
INTERNAL
BUS A
1
2
1
2
Communication
Circuit
Pi 1 20A/20B
Pi 2 18A/18B
Pi 3 16A/16B
Pi 4 14A/14B
Pi 5 12A/12B
Pi 6 10A/10B
Pi 7 8A/8B
Pi 8 6A/6B
Pi 9 19A/19B
Pi 10 17A/17B
Pi 11 15A/15B
Pi 12 13A/13B
Pi 13 11A/13B
Pi 14 9A/9B
Pi 15 7A/7B
Pi 16 5A/5B
4A/4B
Pi 1 20A/20B
Pi 2 18A/18B
Pi 3 16A/16B
Pi 4 14A/14B
Pi 5 12A/12B
Pi 6 10A/10B
Pi 7 8A/8B
INTERNAL
BUS B*
Control
Circuit
3
3
INTERNAL
POWER
4
4
5
5
DIP SW
6
6
7
7
8
8
Pi 8 6A/6B
9
9
Pi 9 19A/19B
Pi 10 17A/17B
Pi 11 15A/15B
Pi 12 13A/13B
Pi 13 11A/13B
Pi 14 9A/9B
Pi 15 7A/7B
Pi 16 5A/5B
10
11
12
13
14
15
16
10
11
12
13
14
15
16
COM(+)
4A/4B
+24V
**
3A/3B
3A/3B
2A/2B
1A/1B
0V
0V
2A/2B
1A/1B
Numbers in italic indicate LED No.s assigned to the front panel LEDs.
For dual redundant communication.
*
**DO NOT use the pin No. 4A/4B and 3A/3B.
R3Y-PA16 SPECIFICATIONS
ES-8962 Rev.7 Page 5/6
https://www.m-system.co.jp/
MODEL: R3Y-PA16
INPUT CONNECTOR (40-pin)
PIN NO.
ASSIGNMENT
PIN NO.
ASSIGNMENT
1A
2A
3A
0V
0V
1B
2B
3B
0V
0V
+24V
+24V
4A
5A
6A
+24V
Pi 16
Pi 8
4B
5B
6B
+24V
Pi 16
Pi 8
7A
8A
9A
Pi 15
Pi 7
7B
8B
9B
Pi 15
Pi 7
Pi 14
Pi 14
10A
11A
12A
Pi 6
Pi 13
Pi 5
10B
11B
12B
Pi 6
Pi 13
Pi 5
13A
14A
15A
Pi 12
Pi 4
13B
14B
15B
Pi 12
Pi 4
Pi 11
Pi 11
16A
17A
18A
Pi 3
Pi 10
Pi 2
16B
17B
18B
Pi 3
Pi 10
Pi 2
19A
20A
Pi 9
Pi 1
19B
20B
Pi 9
Pi 1
Specifications are subject to change without notice.