R5T-PC22S/Q [MSYSTEM]

Remote I/O R5 Series PULSE OUTPUT MODULE;
R5T-PC22S/Q
型号: R5T-PC22S/Q
厂家: M-SYSTEM    M-SYSTEM
描述:

Remote I/O R5 Series PULSE OUTPUT MODULE

输出元件
文件: 总3页 (文件大小:119K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: R5T-PC2  
steel  
Remote I/O R5 Series  
Isolation: Po 1 to Po 2 to internal bus or internal power  
RUN indicator: Bi-color (red/green) LED;  
Red when the bus A operates normally;  
PULSE OUTPUT MODULE  
(screw terminal block; photo MOSFET relay output, 2 points)  
Green when the bus B operates normally;  
Amber when both buses operate normally.  
Output status indicator: Red LED; turns on with the outputs  
ON.  
18 (.71)  
Pulse width adjustment: 5 msec., 10 msec., 50 msec., 100  
msec., 500 msec., 1 sec., 1.5 sec., 2 sec. (Side DIP SW)  
Count reset: Via DIP switches on the side  
90  
(3.54)  
137  
(5.39)  
OUTPUT SPECIFICATIONS  
mm (inch)  
Output: Photo MOSFET relay contact, 2 points  
Common: Each point independent  
Rated load: 125 V AC/DC @ 50 mA (resistive load)  
Maximum ON resistance: 50 Ω  
MODEL: R5T–PC2[1][2]  
Maximum frequency: 100 Hz (DIP SW selectable)  
Totalized pulse range: 1 – 10000 (‘0’ at reset)  
(Max. pulse range selectable from 100 to 60000 using the  
R5CON PC Configurator Software. Refer to the R5CON Users  
Manual for detailed information.)  
ORDERING INFORMATION  
• Code number: R5T-PC2[1][2]  
Specify a code from below for each of [1] and [2].  
(e.g. R5T-PC2W/Q)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
Count at overflow: Reset and restart at ‘1.’  
INSTALLATION  
NO. OF CHANNELS  
2: 2-point outputs  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: Installation Base (model: R5-BS)  
Weight: 110 g (0.24 lb)  
[1] COMMUNICATION MODE  
S: Single  
W: Dual  
PERFORMANCE  
Data allocation: 2  
[2] OPTIONS  
blank: none  
Response time: ≤ 0.1 sec.  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute  
(Po 1 to Po 2 to internal bus or internal power)  
2000 V AC @ 1 minute (power input to FG;  
isolated on the power supply module)  
/Q: With options (specify the specification)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
GENERAL SPECIFICATIONS  
Connection  
Internal bus: Via the Installation Base (model: R5-BS)  
Output: M3.5 screw terminal block (torque 0.8 N·m)  
Internal power: Via the base (model: R5-BS)  
Screw terminal: Nickel-plated steel (standard) or stainless  
R5T-PC2 SPECIFICATIONS  
ES-7574 Rev.9 Page 1/3  
https://www.m-system.co.jp/  
MODEL: R5T-PC2  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
EN 61010-1, EN 61010-2-201  
Measurement Category II (output)  
Pollution Degree 2  
Output to internal bus or internal power – Basic insulation  
(300 V)  
RoHS Directive  
FUNCTIONS  
Counter reset  
1) Remove Network Module or its cables and interrupt  
communication with other devices.  
2) Turn ON the Counter Reset SW (SW8) on the module.  
3) Return the module to the base and turn the power supply  
on.  
4) Red RUN LED turns on and the module starts resetting its  
counter. When the resetting is complete, the LED light turns  
to green. DO NOT remove the power while the red light is  
on.  
5) After the green LED is confirmed, turn the power supply  
off.  
6) Turn OFF the Counter Reset SW (SW8).  
7) Return the Network module onto the base and turn the  
power supply on.  
Note: Counter Reset SW must be turned OFF after this  
procedure because the module does not start counting with  
ON state.  
EXTERNAL VIEW  
SIDE VIEW  
FRONT VIEW  
RUN LED  
Status Indicator LED  
RUN  
1
2
3
4
1 2 3 4 5 6 7 8  
4
ON  
OFF  
Counter  
Reset  
5
2
6
3
Pulse Width  
Unused  
1
Counter Reset SW is normally OFF during operation.  
R5T-PC2 SPECIFICATIONS  
ES-7574 Rev.9 Page 2/3  
https://www.m-system.co.jp/  
MODEL: R5T-PC2  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]  
LOCKING CLAMP  
18 (.71)  
38.5 (1.52)  
98.5 (3.88)  
TERMINAL COVER  
8.2 (.32)  
6–M3.5  
TERMINAL  
SCREWS  
4
5
2
6
3
7.2 (.28)  
POSITIONING GUIDE  
1
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
RUN OUTPUT STATUS  
LED INDICATOR LED  
• • • •  
Isolation  
Isolation  
INTERNAL BUS A  
1
3
Communication  
Circuit  
1
3
4
6
2
5
Po 1  
*INTERNAL BUS B  
Control  
Circuit  
COM1  
Po 2  
INTERNAL POWER  
COM2  
DIP SW  
*For dual redundant communication.  
Note: Italic typed numbers correspond to the LEDs on the front panel.  
Specifications are subject to change without notice.  
R5T-PC2 SPECIFICATIONS  
ES-7574 Rev.9 Page 3/3  
https://www.m-system.co.jp/  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY