R7D-TS4-AR/UL [MSYSTEM]

Remote I/O R7 Series CC-Link I/O MODULE;
R7D-TS4-AR/UL
型号: R7D-TS4-AR/UL
厂家: M-SYSTEM    M-SYSTEM
描述:

Remote I/O R7 Series CC-Link I/O MODULE

文件: 总46页 (文件大小:1242K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: R7C  
(CE not available. Option /UL Not selectable)  
Remote I/O R7 Series  
CC-Link I/O MODULE  
MS4: Potentiometer input, 4 points  
(Option /UL Not selectable)  
CT4E: AC current input, 4 points,  
Clamp-on current sensor CLSE use  
(Option /UL Not selectable)  
PA8: Totalized pulse input, 8 points,  
(CE not available, option /UL Not selectable)  
(Terminating resistor incorporated)  
YV2: DC voltage output, 2 points  
YV4:DC voltage output, 4 points  
(Option /UL not selectable)  
(Not usable with ‘extension’ modules)  
(Terminating resistor incorporated)  
YS2: DC current output, 2 points  
YS4: DC current output, 4 points  
(Option /UL not selectable)  
ORDERING INFORMATION  
• Basic module: R7C-[1]-[2][3]  
Specify a code from below for each of [1] through [3].  
(e.g. R7C-DC16A-R/Q)  
(Not usable with ‘extension’ modules)  
(Terminating resistor incorporated)  
• Specify the specification for option code /Q  
(e.g. /C01)  
If you need factory setting, use Ordering Information Sheet  
(No. ESU-7801-x).  
[2] POWER INPUT  
DC Power  
• Extension module: R7C-[1][2]  
Specify a code from below for each of [1] and [2].  
(e.g. R7C-EC16A/Q)  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
Universal  
• Specify the specification for option code /Q  
(e.g. /C01)  
AR: 24 V AC/24 V DC (Only for R7C-RR4, PA8, YV4 and YS4)  
(Operational voltage range 24 V AC±10 %, 50 - 60 Hz /  
24 V DC±10 %, ripple 10 %p-p max.)  
(CE not available)  
BASIC MODULE: R7C–[1]–[2][3]  
[3] OPTIONS  
[1] I/O TYPE  
Standards & Approvals  
DA16: Discrete input, 16 points  
blank: CE marking  
DC16A: NPN transistor output, 16 points  
(Not usable with R7C-EA8 or R7C-EA16)  
DC16B: PNP transistor output, 16 points  
(Not usable with R7C-EA8 or R7C-EA16)  
DC8C: Relay contact output, 8 points  
(Option /UL Not selectable)  
/UL: UL approval, CE marking  
Other Options  
blank: none  
/Q: Option other than the above (specify the specification)  
(UL not available)  
(Not usable with ‘extension’ modules)  
DC8E: Relay contact output, 8 points  
(CE not available. Option /UL Not selectable)  
(Not usable with R7C-EA8 or R7C-EA16)  
(Terminating resistor incorporated)  
RR4: Remote control relay control, 4 points  
(CE not available. Option /UL Not selectable)  
(Not usable with ‘extension’ modules)  
(Terminating resistor incorporated)  
SV4: DC voltage/current input (10 V/20 mA), 4 points  
TS4: Thermocouple input, 4 points  
RS4: RTD input, 4 points  
EXTENSION MODULE: R7C–[1][2]  
[1] I/O TYPE  
EA8: Discrete input, 8 points  
EA16: Discrete input, 16 points  
EC8A: NPN transistor output, 8 points  
EC16A: NPN transistor output, 16 points  
EC8B: PNP transistor output, 8 points  
EC16B: PNP transistor output, 16 points  
EC8C: Relay contact output, 8 points  
(CE not available. Option /UL Not selectable)  
RT4A: Thermistor input , 4 points  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 1/46  
http://www.m-system.co.jp/  
MODEL: R7C  
[2] OPTIONS  
GENERAL SPECIFICATIONS  
STANDARDS & APPROVALS  
Common Specifications  
blank: CE marking  
Power input:  
/UL: UL approval, CE marking  
Other Options  
24 V AC ±10 % (50 / 60 Hz)  
24 V DC ±10 %; ripple 10 %p-p max.  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @1 minute  
(between isolated circuits)  
blank: none  
/Q: Option other than the above (specify the specification)  
(UL not available)  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Storage temperature: -20 to +65°C (-4 to +149°F)  
Mounting: DIN rail (35 mm wide)  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
Connection: M3 separable screw terminals  
(torque 0.5 N·m)  
/C03: Rubber coating  
Screw terminal material: Nickel-plated steel  
Solderless terminal: Refer to the drawing at the end of the  
section.  
FUNCTIONS & FEATURES  
The R7C interfaces analog and discrete I/O signals with a  
PLC via CC-Link.  
Recommended manufacturer: Japan Solderless Terminal  
MFG.Co.Ltd, Nichifu Co.,ltd  
A ‘basic’ module can be attached with an ‘extension’  
module. (Exceptions: refer to the I/O type specifications) By  
combining two modules, single station can handle mixed  
analog and discrete signals, 32-point discrete inputs, 32-  
point discrete outputs, 16-point discrete I/Os and other  
combinations of signals. Only the combination of basic  
discrete output and extension discrete input modules is not  
available.  
Applicable wire size: 0.25 to 1.65 mm (AWG22 to 16)  
2
Housing material: Flame-resistant resin (gray)  
Status indicator LED: PWR (Refer to the instruction manual  
for details)  
DC Power Current Consumption & Weight  
R7C-DA16: Approx. 60 mA, 200 g (0.44 lb)  
R7C-DC16A: Approx. 75 mA, 200 g (0.44 lb)  
R7C-DC16B: Approx. 75 mA, 200 g (0.44 lb)  
R7C-DC8C: Approx. 60 mA (approx. 60 mA), 200 g (0.44 lb)  
R7C-DC8E: Approx. 60 mA (approx. 60 mA), 200 g (0.44 lb)  
R7C-RR4: Approx. 65 mA, 170 g (0.37 lb)  
R7C-SV4: Approx. 90 mA, 200 g (0.44 lb)  
R7C-TS4: Approx. 90 mA, 200 g (0.44 lb)  
R7C-RS4: Approx. 90 mA, 200 g (0.44 lb)  
R7C-RT4A: Approx. 95 mA, 200 g (0.44 lb)  
R7C-MS4: Approx. 110 mA, 200 g (0.44 lb)  
R7C-CT4E: Approx. 140 mA, 200 g (0.44 lb)  
R7C-PA8: Approx. 70 mA, 200 g (0.44 lb)  
R7C-YV2: Approx. 140 mA, 180 g (0.40 lb)  
R7C-YV4: Approx. 90 mA, 180 g (0.40 lb)  
R7C-YS2: Approx. 140 mA, 180 g (0.40 lb)  
R7C-YS4: Approx. 160 mA, 180 g (0.40 lb)  
R7C-EA8: Approx. 10 mA, 90 g (0.20 lb)  
R7C-EA16: Approx. 20 mA, 150 g (0.33 lb)  
R7C-EC8A: Approx. 10 mA, 90 g (0.20 lb)  
R7C-EC16A: Approx. 20 mA, 150 g (0.33 lb)  
R7C-EC8B: Approx. 10 mA, 90 g (0.20 lb)  
R7C-EC16B: Approx. 20 mA, 150 g (0.33 lb)  
R7C-EC8C: Approx. 40 mA, 150 g (0.33 lb)  
The consumed current of supply power for the output is  
shown in ().  
Input sensor type (thermocouple, RTD) and range can be  
selected with the front DIP switches for all channels. In  
order to set different selections for individual channels,  
zero/span adjustments, scaling and temperature unit, use  
the PC Configurator Software (model: R7CON)  
RELATED PRODUCTS  
• PC configurator software (model: R7CON)  
Downloadable at M-System’s web site.  
A dedicated cable is required to connect the module to the  
PC. Please refer to the internet software download site or  
the users manual for the PC configurator for applicable  
cable types.  
• Clamp-on current sensor (model: CLSE)  
For R7C-CT4E, the clamp-on current sensors must be  
ordered separately. Required number depends upon the  
channel number.  
PACKAGE INCLUDES...  
• Terminating resistor (110 Ω, 0.5 W)  
(Not provided for models terminating resistor incorporated)  
AC Power Current Consumption  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 2/46  
http://www.m-system.co.jp/  
MODEL: R7C  
R7C-RR4: Approx. 100 mA  
R7C-PA8: Approx. 130 mA  
R7C-YV4: Approx. 180 mA  
R7C-YS4: Approx. 280 mA  
Station Type  
EN 50581  
Approval:  
UL/C-UL nonincendive Class I, Division 2,  
Groups A, B, C, and D  
(ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)  
UL/C-UL general safety requirements  
(UL 61010-1, CAN/CSA-C22.2 No.61010-1)  
R7C-DA16: Remote I/O  
R7C-DC16A: Remote I/O  
R7C-DC16B: Remote I/O  
R7C-DC8C: Remote I/O  
R7C-DC8E: Remote I/O  
R7C-RR4: Remote I/O  
R7C-SV4: Remote device  
R7C-TS4: Remote device  
R7C-RS4: Remote device  
R7C-RT4A: Remote device  
R7C-MS4: Remote device  
R7C-CT4E: Remote device  
R7C-PA8: Remote device  
R7C-YV2: Remote device  
R7C-YV4: Remote device  
R7C-YS2: Remote device  
R7C-YS4: Remote device  
■ Recommended solderless terminal  
3.3 (.13) max  
mm (inch)  
CC-Link COMMUNICATION  
CC-Link: Ver.1.10  
Network cable: CC-Link cable designated by Mitsubishi  
Electric  
Station address setting: 1 - 64 (rotary switch, default:00)  
Baud rate setting: 156 kbps (default), 625 kbps, 2.5 Mbps,  
5 Mbps, 10 Mbps (rotary switch)  
Status indicator LEDs: RUN, ERR, SD, RD  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
(Only R7C-DC8C conforms to it. Refer to the instruction  
manual for the detailed information.)  
EN 61010-1, EN 61010-2-201  
Measurement Category II (output)  
Pollution Degree 2  
Output to power: Basic insulation (150 V)  
RoHS Directive  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 3/46  
http://www.m-system.co.jp/  
MODEL: R7C  
EXTERNAL VIEW  
BASIC MODULE  
• SIDE VIEW  
• FRONT VIEW  
Baud Rate Setting Rotary SW  
Operating Mode Setting DIP SW (SW1)  
2
*
Station Address Setting  
Rotary SW  
PC Configurator Jack  
3
*
Discrete I/O Status Indicator LED  
1
*
Status Indicator LED  
1
2 3 4 5 6 7 8  
X10  
5
X1  
5
PWR  
ERR  
RD  
0 1 2 3 4 5 6 7 8 9 A B C D E F  
5
0
0
0
RUN  
SD  
CNFG.  
STATION ADD.  
B.RATE  
4
5
6
7
10 11 12 13 14 15 16 17 18  
1
2
3
1
2
3
4
5
6
7
8
9
CC-Link, Power Supply  
Terminals  
4
5
*
*
I/O Terminals  
Terminating Resistor SW  
*1. Refer to Status Indicator LEDsection for detailed information.  
*2. Not available with discrete I/O modules.  
*3. Not available with analog I/O modules.  
*4. 10 screw terminals for analog output modules.  
*5. Only for R7C-DC8E, RR4, PA8, YV4 and YS4.  
■ EXTENSION MODULE  
DISCRETE, 8 POINTS  
Discrete I/O Status Indicator LED  
0
1
2
3
4
5
6
7
6
7
8
9
10  
1
2
3
4
5
I/O Terminals  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 4/46  
http://www.m-system.co.jp/  
MODEL: R7C  
DISCRETE, 16 POINTS  
Discrete I/O Status Indicator LED  
0
1 2 3 4 5 6 7 8 9 A B C D E F  
10 11 12 13 14 15 16 17 18  
1
2
3
4
5
6
7
8
9
I/O Terminals  
CONNECTION DIAGRAMS  
POWER SUPPLY, CC-LINK TERMINAL ASSIGNMENT  
• Except R7C-RR4, PA8,YV4 andYS4  
R7C-RR4, PA8,YV4 andYS4  
4
5
6
7
4
5
6
7
DA  
DG +24 V  
0V  
DA  
DG  
U (+) V (-)  
3
1
2
3
1
2
DB  
SLD  
FG  
DB  
SLD  
FG  
ID  
ID  
NO.  
FUNCTION, NOTES  
NO.  
FUNCTION, NOTES  
White  
White  
Shield  
1
2
3
4
5
6
7
DB  
SLD  
FG  
1
2
3
4
5
6
7
DB  
SLD  
FG  
Shield  
FG  
FG  
Blue  
Blue  
DA  
DA  
Yellow  
Yellow  
DG  
DG  
Power input (24 V DC)  
Power input (0 V DC)  
Power input  
Power input  
+24 V  
0 V  
U (+)  
V (-)  
MASTER CONNECTION  
Master Unit  
Remote Unit  
Remote Unit  
TERMINATOR  
TERMINATOR  
blue  
DA  
DB  
DA  
DB  
DA  
DB  
white  
yellow  
DG  
SLD  
FG  
DG  
SLD  
FG  
DG  
SLD  
FG  
Be sure to connect the terminating resistor included in the product package to the unit at both ends of transmission line.  
Or turn the terminating resistor SW ON for models with the resistor incorporated.  
The terminator must be connected across DA and DB.  
The Master Unit can be located other than at the extreme ends of transmission line.  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 5/46  
http://www.m-system.co.jp/  
MODEL: R7C  
INDICATOR LED  
STATUS INDICATOR LED  
SD*1 RD  
STATUS*2  
PWR  
ON  
RUN ERR  
ON BL  
ON BL  
BL ON Communicates normally with occasional CRC errors due to noise interference.  
ON  
BL ON Communicates normally but the Baud Rate and/or Station Address switches failed.  
ERR LED blinks approximately in 0.5 seconds intervals.  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON BL  
ON BL  
ON BL  
ON OFF  
ON OFF  
ON OFF  
ON OFF  
OFF BL  
BL OFF ----  
OFF ON CRC error found in the received data. Unable to respond.  
OFF OFF ----  
BL ON Normal communication  
BL OFF ----  
OFF ON Unable to receive data addressed to the station.  
OFF OFF ----  
BL ON Performs the interval-timed responses but CRC error found in receiving the refresh  
data.  
ON  
ON  
ON  
ON  
ON  
ON  
OFF BL  
OFF BL  
OFF BL  
OFF OFF  
OFF OFF  
OFF OFF  
BL OFF ----  
OFF ON CRC error found in the data addressed to the station.  
OFF OFF ----  
BL ON Link is not started.  
BL OFF ----  
OFF ON No data addressed to the station. Or unable to receive data addressed to the station  
due to noise interference. (Missing parts of the data sent from the master)  
OFF OFF Unable to receive data due to wire breakdown  
ON  
ON  
OFF OFF  
OFF ON  
OFF OFF  
OFF ON/OFF Faulty Baud Rate and/or Station Address setting  
OFF  
OFF OFF Power input removed. Or power supply failure.  
OFF = OFF, ON = ON, BL = Blinking  
*1. SD LED may look not blinking but ON with high baud rate and fewer connected modules.  
*2. LEDs indicated with “----” in STATUS rarely occurs in normal operation. (LED failure or the like as possible cause).  
DISCRETE I/O STATUS INDICATOR LED  
Discrete I/O modules, including those for extensions, have LED indicators showing I/O signal status.  
Totalized pulse modules have LED indicators showing input signal status.  
Contact ON : LED ON  
Contact OFF : LED OFF  
DATA CONVERSION  
I 0 – 100% DATA CONVERSION  
Analog input data is converted into digital representations of 0 – 100% proportional to each scaled range. The converted %  
values are multiplied by 100 and expressed in 16 bits.  
Overrange input is possible from -15 to +115% of the nominal range. When the signal exceeds the limit, the data is fixed at  
-15% or +115% respectively. Negative value is represented in 2ʼs complements.  
• Input Range 0 – 5 V DC  
Converted Data, Decimal  
Converted Data, Hex  
Input Value  
≤ -0.75 V  
0 V  
Input %  
-15%  
0%  
-1500  
0
FA24  
0
10000  
11500  
5 V  
100%  
115%  
2710  
2CEC  
≥ 5.75 V  
11500 (2CEC)  
10000 (2710)  
-0.75  
0
-1500 (FA24)  
5.0  
5.75  
(V)  
Analog output is converted in the reverse order of the input data. The output range 0 – 5 V DC is expressed as 10000 at  
5.0 V (100%) and 0 at 0 V (0%).  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 6/46  
http://www.m-system.co.jp/  
MODEL: R7C  
I ENGINEERING UNIT CONVERSION  
Engineering unit value °C or K is multiplied by 10 and expressed in 16 bits. °F data is represented in engineering unit  
value, without multiplication. Engineering unit value A is multiplied by 100 or 1000, expressed in 16 bits. Negative value  
is represented in 2ʼs complements.  
• Input TYPE K Thermocouple  
Converted Data, Decimal  
Converted Data, Hex  
Input Value  
≤ -272°C  
-150°C  
-2720  
-1500  
13700  
14720  
F560  
FA24  
3584  
3980  
1370°C  
≥ 1472°C  
14720 (3980)  
13700 (3584)  
-272 -150  
1370  
1472  
(°C)  
-1500 (FA24)  
-2720 (F560)  
COUNT VALUE  
The count value is 32-bit data. It is divided in 2 words of 16 bits represented with 2 addresses.The lower address is  
allocated in the lower word (LSB) and the upper address in the upper word (MSB). The count value is 0 - 4 294 967 295.  
The maximum count value available is 1 000 - 4 294 967 295. In case of overflow, the vaule is reset to 0 or 1  
(configurable) from which the count will restart. The preset of the count value is also available. Use the R7CON or  
commands for the configuration.  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 7/46  
http://www.m-system.co.jp/  
MODEL: R7C  
DATA ALLOCATION  
R7C-DA16  
Interval-timed Response (X)  
Refresh Data (Y)  
Refresh Data (Y)  
Refresh Data (Y)  
0
F
0
F
RX(n+0)F to RX(n+0)0  
Unused  
(R7C-DA16)  
Unused  
1F  
1F  
R7C-DA16 + R7C-EA16  
Interval-timed Response (X)  
0
0
F
RX(n+0)F to RX(n+0)0  
RX(n+1)F to RX(n+1)0  
(R7C-DA16)  
(R7C-EA16)  
F
Unused  
1F  
1F  
R7C-DA16 + R7C-EC16x  
Interval-timed Response (X)  
0
0
F
RX(n+0)F to RX(n+0)0  
Unused  
(R7C-DA16)  
Unused  
RY(n+1)F to RY(n+1)0  
F
(R7C-EC16x)  
1F  
1F  
R7C-DC16x  
Interval-timed Response (X)  
Refresh Data (Y)  
0
0
F
RY(n+0)F to RY(n+0)0  
Unused  
(R7C-DC16x)  
F
Unused  
1F  
1F  
R7C-DC16x + R7C-EC16x  
Interval-timed Response (X)  
Refresh Data (Y)  
0
0
F
RY(n+0)F to RY(n+0)0  
RY(n+1)F to RY(n+1)0  
(R7C-DC16x)  
(R7C-EC16x)  
F
Unused  
1F  
1F  
R7C-DC8x  
Refresh Data (Y)  
Interval-timed Response (X)  
0
0
F
(R7C-DC8C)  
RY(n+0)7 to RY(n+0)0  
Unused  
F
Unused  
1F  
1F  
R7C-DC8E + R7C-EC16x  
Interval-timed Response (X)  
Refresh Data (Y)  
0
0
F
(R7C-DC8E)  
(R7C-EC16x)  
RY(n+0)7 to RY(n+0)0  
RY(n+1)F to RY(n+1)0  
F
Unused  
1F  
1F  
R7C-RR4  
Interval-timed Response (X)  
RX(n+0)3 to RX(n+0)0 (R7C-RR4)  
Refresh Data (Y)  
0
0
RY(n+0)F to RY(n+0)8  
Unused  
(R7C-RR4)  
F
F
Unused  
1F  
1F  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 8/46  
http://www.m-system.co.jp/  
MODEL: R7C  
R7C-PA8  
• Data allocation 1  
Interval timed Response (X)  
Refresh Data (Y)  
RX (n+0)  
RX (n+1)  
RX (n+0) D – RX (n+0) 0: Command  
Unused  
RY (n+0) RY (n+0) A – RY (n+0) 0: Command  
RY (n+1) Unused  
Interval-timed Response (X)  
Input extension  
Refresh Data (Y)  
RWr (n+0)  
RWr (n+1)  
RWw (n+0) Output extension  
Unused  
RWw (n+1) Unused  
RWr (n+2) Count data (LSB)  
RWr (n+3) Count data (MSB)  
RWw (n+2) Preset data (LSB)  
RWw (n+3) Preset data (MSB)  
• Data allocation 4  
Interval-timed Response (X)  
Refresh Data (Y)  
RX (n+0)  
RX (n+1)  
RX (n+0) D – RX (n+0) 0: Command  
Input extension  
RY (n+0) RY (n+0)A – RY (n+0) 0: Command  
RY (n+1) Output extension  
Interval-timed Response (X)  
ch0 Count data (LSB)  
Refresh Data (Y)  
RWr (n+0)  
RWr (n+1)  
RWw (n+0)  
RWw (n+1)  
ch0 Preset data (LSB)  
ch0 Preset data (MSB)  
ch0 Count data (MSB)  
RWr (n+2) ch1 Count data (LSB)  
RWr (n+3) ch1 Count data (MSB)  
RWw (n+2) ch1 Preset data (LSB)  
RWw (n+3) ch1 Preset data (MSB)  
RWr (n+4)  
RWr (n+5)  
ch2 Count data (LSB)  
ch2 Count data (MSB)  
RWw (n+4)  
RWw (n+5)  
ch2 Preset data (LSB)  
ch2 Preset data (MSB)  
RWr (n+6) ch3 Count data (LSB)  
RWr (n+7) ch3 Count data (MSB)  
RWw (n+6) ch3 Preset data (LSB)  
RWw (n+7) ch3 Preset data (MSB)  
RWr (n+8)  
RWr (n+9)  
ch4 Count data (LSB)  
ch4 Count data (MSB)  
RWw (n+8)  
RWw (n+9)  
ch4 Preset data (LSB)  
ch4 Preset data (MSB)  
RWr (n+10) ch5 Count data (LSB)  
RWr (n+11) ch5 Count data (MSB)  
RWw (n+10) ch5 Preset data (LSB)  
RWw (n+11) ch5 Preset data (MSB)  
RWr (n+12)  
RWr (n+13)  
ch6 Count data (LSB)  
ch6 Count data (MSB)  
RWw (n+12)  
RWw (n+13)  
ch6 Preset data (LSB)  
ch6 Preset data (MSB)  
RWr (n+14) ch7 Count data (LSB)  
RWr (n+15) ch7 Count data (MSB)  
RWw (n+14) ch7 Preset data (LSB)  
RWw (n+15) ch7 Preset data (MSB)  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 9/46  
http://www.m-system.co.jp/  
MODEL: R7C  
ANALOG INPUT  
• Models R7C-SV4, R7C-TS4, R7C-RS4, R7C-RT4A, R7C-MS4, R7C-CT4E  
Interval-timed Response (X)  
Refresh Data (Y)  
RWrn+0  
+1  
RWwn+0  
Analog input 0  
Analog input 1  
Analog input 2  
Analog input 3  
Unused  
Unused  
Unused  
Unused  
+1  
+2  
+3  
+2  
+3  
• Without Extension Module  
Interval-timed Response (X)  
Refresh Data (Y)  
Refresh Data (Y)  
Refresh Data (Y)  
0
0
F
RX(n+0)F to RX(n+0)0  
Reserved  
(Status)  
F
Unused  
1F  
1F  
• With Extension Module R7C-EA16  
Interval-timed Response (X)  
0
0
F
RX(n+0)F to RX(n+0)0  
Reserved  
(R7C-EA16)  
F
Unused  
1F  
1F  
• With Extension Module R7C-EC16x  
Interval-timed Response (X)  
0
0
F
RX(n+0)F to RX(n+0)0  
(Status)  
RY(n+0)F to RY(n+0)0  
Unused  
(R7C-EC16x)  
F
Reserved  
1F  
1F  
ANALOG OUTPUT  
• Models R7C-YV2, R7C-YV4, R7C-YS2, R7C-YS4  
Interval-timed Response (X)  
Refresh Data (Y)  
RWrn+0  
+1  
RWwn+0  
Unused  
Unused  
Unused  
Unused  
Analog output 0  
Analog output 1  
+1  
+2  
+3  
+2  
Analog output 2 (R7C-YV2, YS2 are unused)  
Analog output 3 (R7C-YV2, YS2 are unused)  
+3  
• Without Extension Module  
Interval-timed Response (X)  
Refresh Data (Y)  
0
0
F
Unused  
F
Unused  
Reserved  
1F  
1F  
• With Extension Module R7C-EA16  
Interval-timed Response (X)  
0
Refresh Data (Y)  
0
F
RX(n+0)F to RX(n+0)0  
(R7C-EA16)  
F
Unused  
Reserved  
1F  
1F  
• With Extension Module R7C-EC16x  
Interval-timed Response (X)  
0
Refresh Data (Y)  
0
F
Unused  
RY(n+0)F to RY(n+0)0  
Unused  
(R7C-EC16x)  
F
Reserved  
1F  
1F  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 10/46  
http://www.m-system.co.jp/  
MODEL: R7C  
I/O DATA DESCRIPTIONS  
DISCRETE I/O  
15  
0
Input 0 (Output 0)  
Input 1 (Output 1)  
Input 2 (Output 2)  
Input 3 (Output 3)  
8 points  
: :  
Input 7 (Output 7)  
16 points  
Input 8 (Output 8)  
: :  
Input 15 (Output 15)  
0 : OFF  
1 : ON  
I R7C-RR4  
15  
0
Feedback input 0  
Feedback input 1  
Feedback input 2  
Feedback input 3  
Not Used  
Output 0 ON  
Output 0 OFF  
Output 3 OFF  
0: OFF 1: ON  
R7C−PA8  
• RX (n+0)  
• RY (n+0)  
15  
0
15  
0
Channel No.  
Channel No.  
Command acknowledge  
Data acknowledge  
Ready signal  
Command acknowledge  
Data selection  
Unused  
Error display  
Unused  
ANALOG I/O  
15  
0
16-bit binary data  
Negative values represented in 2s complements  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 11/46  
http://www.m-system.co.jp/  
MODEL: R7C  
STATUS  
Analog input modules without extension module (models: R7C-SV4, R7C-TS4, R7C-RS4, R7C-RT4A, R7C-MS4, R7C-CT4E)  
can show input status of each channel. Analog output modules (models: R7C-YV2, R7C-YV4, R7C-YS2, R7C-YS4), discrete I/O  
modules (models: R7C-DA16, R7C-DCx, R7C-RR4) and Totalized pulse input module (R7C-PA8) show '0' at the same address.  
15  
0
Input 0 (Burnout, input range error)  
Input 1 (Burnout, input range error)  
Input 2 (Burnout, input range error)  
Input 3 (Burnout, input range error)  
Input 0 (ADC error)  
Input 1 (ADC error)  
Input 2 (ADC error)  
Input 3 (ADC error)  
Unused  
:
Unused  
Burnout, input range error (≤-15%, ≥+115%)  
0 : Normal 1 : Error  
ADC error (no response from ADC)  
0 : Normal 1 : Error  
EXTENSION MODULE  
A ‘basic’ module can be attached with one ‘extension’ module. The extension module is powered from the basic module.  
By combining two modules, single station can handle mixed analog and discrete signals, 32-point discrete inputs, 32-point  
discrete outputs, 16-point discrete I/Os and other combinations of signals.  
MODULE COMBINATIONS  
(Basic module: Extension modules)  
R7C-DA16: R7C-EA8, R7C-EA16, R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
R7C-DC16A*  
1
: R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
: R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
R7C-DC16B*  
1
R7C-DC8C*  
R7C-DC8E*  
R7C-RR4* : ----  
2
: ----  
1:R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
2
R7C-SV4: R7C-EA8, R7C-EA16, R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
R7C-TS4: R7C-EA8, R7C-EA16, R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
R7C-RS4: R7C-EA8, R7C-EA16, R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
R7C-RT4A: R7C-EA8, R7C-EA16, R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
R7C-MS4: R7C-EA8, R7C-EA16, R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
R7C-CT4E: R7C-EA8, R7C-EA16, R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
R7C-PA8: R7C-EA8, R7C-EA16, R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
R7C-YV2: R7C-EA8, R7C-EA16, R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
R7C-YV4*  
R7C-YS2: R7C-EA8, R7C-EA16, R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C  
R7C-YS4* : ----  
2: ----  
2
*1. Not usable with R7C-EA8 or R7C-EA16.  
*2. Not usable with 'Extension' modules.  
OUTPUT AT THE LOSS OF COMMUNICATION  
For the extension module R7C-DA16, R7C-DC16x or R7C-DC8E  
The extension modules (R7C-EC8A, R7C-EC16A, R7C-EC8B, R7C-EC16B, R7C-EC8C) are set to ‘Reset Output’ or ‘Hold Output’  
according to the setting of SW1-5 of the module.  
For the extension module other than R7C-DA16, R7C-DC16x or R7C-DC8E  
The extension module is set to ‘Hold Output’ by factory default setting. The PC Configurator software is used to change the  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 12/46  
http://www.m-system.co.jp/  
MODEL: R7C  
setting to ‘Reset Output.’  
CONNECTING THE EXTENSION MODULE  
1) Remove the extension connector cover located at the side of the basic module.  
2) Connect the extension module.  
3) Mount the combined module on a DIN rail.  
EXTERNAL DIMENSIONS unit: mm (inch)  
■ BASIC MODULE  
115 (4.53)  
17 (.66)  
54 (2.13)  
DIN RAIL  
35mm wide  
4
5
6
7
10 11 12 13 14 15 16 17 18  
1
2
3
1
2
3
4
5
6
7
8
9
30 (1.18)  
[5 (.20)]  
• R7C-TS4  
6 (.24)  
6 (.24)  
17 (.66)  
54 (2.13)  
7–M3 SCREW  
TERMINALS  
for CC-Link, POWER  
18–M3 SCREW  
TERMINALS for I/O  
DIN RAIL  
35mm wide  
30 (1.18)  
[5 (.20)]  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 13/46  
http://www.m-system.co.jp/  
MODEL: R7C  
■ BASIC MODULE, ANALOG OUTPUT, R7C-RR4  
115 (4.53)  
17 (.66)  
54 (2.13)  
DIN RAIL  
35mm wide  
4
5
6
7
6
7
8
9
10  
1
2
3
1
2
3
4
5
30 (1.18)  
[5 (.20)]  
6 (.24)  
6 (.24)  
7–M3 SCREW  
TERMINALS  
for CC-Link, POWER  
10–M3 SCREW  
TERMINALS  
for OUTPUT  
■ EXTENSION MODULE (R7C-EA8, R7C-EC8A, R7C-EC8B)  
11.5  
(.45)  
65 (2.56)  
17 (.66)  
54 (2.13)  
DIN RAIL  
35mm wide  
6
7
8
9
10  
1
2
3
4
5
30 (1.18)  
[5 (.20)]  
6 (.24)  
10–M3 SCREW  
TERMINALS for I/O  
■ EXTENSION MODULE (R7C-EA16, R7C-EC16A, R7C-EC16B, R7C-EC8C)  
17 (.66)  
54 (2.13)  
11.5  
(.45)  
94 (3.70)  
DIN RAIL  
35mm wide  
10 11 12 13 14 15 16 17 18  
1
2
3
4
5
6
7
8
9
30 (1.18)  
[5 (.20)]  
6 (.24)  
18–M3 SCREW  
TERMINALS for I/O  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 14/46  
http://www.m-system.co.jp/  
MODEL: R7C  
DISCRETE INPUT MODULE, 16 points  
MODEL: R7C-DA16  
TERMINAL ASSIGNMENTS  
10  
11  
X1  
12  
X3  
13  
X5  
14  
X7  
15  
X9  
16  
XB  
17  
XD  
18  
XF  
COM  
1
2
3
4
5
6
7
8
9
COM  
X0  
X2  
X4  
X6  
X8  
XA  
XC  
XE  
SPECIFICATIONS  
Common: Positive or negative common (NPN/PNP) per  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
1
2
3
4
5
6
7
8
9
COM Common  
10 COM Common  
X0  
X2  
X4  
X6  
X8  
Input 0  
Input 2  
Input 4  
Input 6  
Input 8  
11  
12  
13  
14  
15  
16  
17  
18  
X1 Input 1  
X3 Input 3  
X5 Input 5  
X7 Input 7  
X9 Input 9  
XB Input 11  
XD Input 13  
XF Input 15  
16 points  
Number of I/O: Input, 16 points  
Maximum inputs applicable at once: No limit (at 24 V DC)  
Input status indicator: LED turns ON with contact ON  
Isolation: Input to power input to CC-Link or FG  
CC-Link: Conforms to Version 1.10  
XA Input 10  
XC Input 12  
XE Input 14  
Station type: Remote I/O  
Data allocation: 1  
Rated input voltage: 24 V DC ±10 %; ripple 5 %p-p max.  
ON voltage / current: ≥ 15 V DC (input – COM) / ≥ 3.5 mA  
OFF voltage / current: ≤ 5 V DC (input – COM) / ≤ 1 mA  
Input current: ≤ 5.5 mA per point at 24 V DC  
Input resistance: Approx. 4.4 kΩ  
ON delay: ≤ 2.0 msec.  
OFF delay: ≤ 2.0 msec.  
OPERATING MODE SETTING  
(*) Factory setting  
Caution ! - SW1-6, 1-7, 1-8 are unused. Be sure to turn off  
unused ones.  
• Output at the Loss of Communication (SW1-5)  
SW1-5 Output at the loss of communication  
OFF Reset the output (turned off)  
ON  
Hold the output (*)  
(maintains the last data received normally)  
• Extension (SW1-1, 1-2, 1-3, 1-4)  
SW1-1 SW1-2 SW1-3 SW1-4 Extension  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF No extension (*)  
ON Discrete input, 8 or 16 points  
ON Discrete output, 8 or 16 points  
OFF  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 15/46  
http://www.m-system.co.jp/  
MODEL: R7C  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
terminal to ground.  
Caution: FG terminal is NOT a protective conductor  
terminal.  
Input Circuit  
1
10  
2
4
1
5
2
3
6
7
COM  
COM  
X0  
DA  
DB  
Comm.  
Circuit  
DG  
3
X2  
SLD  
FG  
4
X4  
5
X6  
24V DC  
0V  
6
X8  
7
XA  
XC  
XE  
X1  
Control  
Circuit  
8
9
11  
12  
13  
14  
15  
16  
17  
18  
X3  
X5  
X7  
X9  
XB  
XD  
XF  
Input Circuit  
1
10  
2
COM  
COM  
X0  
Control  
Circuit  
18  
XF  
Input Connection Examples  
PNP Connection  
NPN Connection  
+
– +  
1
10  
2
1
COM  
COM  
X0  
COM  
COM  
X0  
10  
2
18  
18  
XF  
XF  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 16/46  
http://www.m-system.co.jp/  
MODEL: R7C  
NPN TRANSISTOR OUTPUT MODULE, 16 points  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
terminal to ground.  
MODEL: R7C-DC16A  
Caution: FG terminal is NOT a protective conductor  
terminal.  
SPECIFICATIONS  
Common: Negative common (NPN) per 16 points  
Number of I/O: Output, 16 points  
Maximum outputs applicable at once: No limit (at 24 V DC)  
Output status indicator: LED turns ON with contact ON  
Isolation: Output to power input to CC-Link or FG  
CC-Link: Conforms to Version 1.10  
Station type: Remote I/O  
Output Circuit  
4
1
5
2
3
6
7
10  
2
DA  
DB  
+24V  
Y0  
Y2  
Y4  
Y6  
Y8  
YA  
YC  
YE  
Y1  
Y3  
Y5  
Y7  
Y9  
YB  
YD  
YF  
0V  
Comm.  
Circuit  
3
DG  
4
SLD  
FG  
5
6
24V DC  
0V  
Data allocation: 1  
7
Rated load voltage: 24 V DC ±10 %  
Rated output current: 0.25 A per point, 2.0 A per common  
Residual voltage: ≤ 1.2 V  
8
Control  
Circuit  
9
Leakage current: ≤ 0.1 mA  
11  
12  
13  
14  
15  
16  
17  
18  
1
ON delay: ≤ 0.5 msec.  
OFF delay: ≤ 1.5 msec.  
(When driving an inductive load, connect a diode in parallel  
with the load.)  
OPERATING MODE SETTING  
(*) Factory setting  
Caution ! - SW1-6, 1-7, 1-8 are unused. Be sure to turn off  
unused ones.  
• Output at the Loss of Communication (SW1-5)  
SW1-5 Output at the loss of communication  
OFF Reset the output (turned off)  
Output Circuit  
ON  
Hold the output (*)  
10  
2
+24V  
Y0  
(maintains the last data received normally)  
• Extension (SW1-1, 1-2, 1-3, 1-4)  
SW1-1 SW1-2 SW1-3 SW1-4 Extension  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF No extension (*)  
Control  
Circuit  
ON Discrete output, 8 or 16 points  
18  
YF  
TERMINAL ASSIGNMENTS  
10  
11  
Y1  
12  
Y3  
13  
Y5  
14  
Y7  
15  
Y9  
16  
YB  
17  
YD  
18  
YF  
+24V  
1
0V  
1
2
3
4
5
6
7
8
9
0V  
Y0  
Y2  
Y4  
Y6  
Y8  
YA  
YC  
YE  
Output Connection Example  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
1
2
3
4
5
6
7
8
9
0 V 0 V (common)  
Y0 Output 0  
Y2 Output 2  
Y4 Output 4  
Y6 Output 6  
Y8 Output 8  
YA Output 10  
YC Output 12  
YE Output 14  
10 +24 V 24 V DC  
10  
1
+24V  
0V  
11  
12  
13  
14  
15  
16  
17  
18  
Y1 Output 1  
Y3 Output 3  
Y5 Output 5  
Y7 Output 7  
Y9 Output 9  
YB Output 11  
YD Output 13  
YF Output 15  
+
2
Y0  
18  
YF  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 17/46  
http://www.m-system.co.jp/  
MODEL: R7C  
PNP TRANSISTOR OUTPUT MODULE, 16 points  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
terminal to ground.  
MODEL: R7C-DC16B  
Caution: FG terminal is NOT a protective conductor  
terminal.  
SPECIFICATIONS  
Common: Positive common (PNP) per 16 points  
Number of I/O: Output, 16 points  
Maximum outputs applicable at once: No limit (at 24 V DC)  
Output status indicator: LED turns ON with contact ON  
Isolation: Output to power input to CC-Link or FG  
CC-Link: Conforms to Version 1.10  
Station type: Remote I/O  
Output Circuit  
4
1
5
2
3
6
7
10  
2
DA  
DB  
+24V  
Y0  
Y2  
Y4  
Y6  
Y8  
YA  
YC  
YE  
Y1  
Y3  
Y5  
Y7  
Y9  
YB  
YD  
YF  
0V  
Comm.  
Circuit  
3
DG  
4
SLD  
FG  
5
6
24V DC  
0V  
Data allocation: 1  
Rated load voltage: 24 V DC ±10 %  
Rated output current: 0.25 A per point, 2.0 A per common  
Residual voltage: ≤ 1.2 V  
7
8
Control  
Circuit  
9
Leakage current: ≤ 0.1 mA  
11  
12  
13  
14  
15  
16  
17  
18  
1
ON delay: ≤ 0.5 msec.  
OFF delay: ≤ 1.5 msec.  
(When driving an inductive load, connect a diode in parallel  
with the load.)  
OPERATING MODE SETTING  
(*) Factory setting  
Caution ! - SW1-6, 1-7, 1-8 are unused. Be sure to turn off  
unused ones.  
• Output at the Loss of Communication (SW1-5)  
SW1-5 Output at the loss of communication  
OFF Reset the output (turned off)  
Output Circuit  
ON  
Hold the output (*)  
10  
2
+24V  
Y0  
(maintains the last data received normally)  
• Extension (SW1-1, 1-2, 1-3, 1-4)  
SW1-1 SW1-2 SW1-3 SW1-4 Extension  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF No extension (*)  
Control  
Circuit  
ON Discrete output, 8 or 16 points  
18  
YF  
0V  
TERMINAL ASSIGNMENTS  
10  
11  
Y1  
12  
Y3  
13  
Y5  
14  
Y7  
15  
Y9  
16  
YB  
17  
YD  
18  
YF  
+24V  
1
1
2
3
4
5
6
7
8
9
0V  
Y0  
Y2  
Y4  
Y6  
Y8  
YA  
YC  
YE  
Output Connection Example  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
1
2
3
4
5
6
7
8
9
0 V 0 V  
10 +24 V 24 V DC (common)  
+
10  
1
+24V  
0V  
Y0 Output 0  
Y2 Output 2  
Y4 Output 4  
Y6 Output 6  
Y8 Output 8  
YA Output 10  
YC Output 12  
YE Output 14  
11  
12  
13  
14  
15  
16  
17  
18  
Y1 Output 1  
Y3 Output 3  
Y5 Output 5  
Y7 Output 7  
Y9 Output 9  
YB Output 11  
YD Output 13  
YF Output 15  
2
Y0  
18  
YF  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 18/46  
http://www.m-system.co.jp/  
MODEL: R7C  
RELAY CONTACT OUTPUT MODULE, 8 points  
MODEL: R7C-DC8C  
TERMINAL ASSIGNMENTS  
10  
+24 V  
11  
Y0  
12  
Y1  
13  
Y2  
14  
Y3  
15  
Y4  
16  
Y5  
17  
Y6  
9
18  
Y7  
1
2
3
4
5
6
7
8
0 V COM0 COM0 COM0 COM0 COM1 COM1 COM1 COM1  
SPECIFICATIONS  
NO. ID  
FUNCTION  
0 V 0 V  
COM0 Common 0  
NO. ID  
FUNCTION  
Common: 1 common per 4 points (4 terminals)  
Common current: Max. 8 A (4 terminals)  
Number of I/O: Relay contact output, 8 points  
Maximum outputs applicable at once: No limit (at 24 V DC)  
Output status indicator: LED turns ON with contact ON  
Isolation: Output to power input to CC-Link or FG  
CC-Link: Conforms to Version 1.10  
1
2
3
4
5
6
7
8
9
10 +24 V 24 V DC  
11  
12  
13  
14  
15  
16  
17  
18  
Y0 Output 0  
Y1 Output 1  
Y2 Output 2  
Y3 Output 3  
Y4 Output 4  
Y5 Output 5  
Y6 Output 6  
Y7 Output 7  
COM0 Common 0  
COM0 Common 0  
COM0 Common 0  
COM1 Common 1  
COM1 Common 1  
COM1 Common 1  
COM1 Common 1  
Station type: Remote I/O  
Data allocation: 1  
Relay driving power: 24 V DC ±10 %, ≥ 60 mA  
Rated load: 250 V AC* @2 A (cos ø = 1)  
30 V DC @2 A (resistive load)  
Electrical life 10 cycles (rate 30/min.)  
5
*When it is used as a product relevant to EU directive, it  
should be used under the Installation Category I, 125 V AC  
or less.  
Maximum switching voltage: 250 V AC or 30 V DC  
Maximum switching power: 500 VA or 60 W  
Minimum load: 24 V DC @5 mA  
Mechanical life: 2 × 10 cycles (rate 300/min.)  
7
When driving an inductive load, external contact protection  
and noise quenching are recommended.  
ON delay: ≤ 10 msec.  
OFF delay: ≤ 10 msec.  
OPERATING MODE SETTING  
(*) Factory setting  
Caution ! - SW1-1 through 1-3, 1-5 through 1-8 are unused.  
Be sure to turn off the unused ones.  
• Output at the Loss of Communication (SW1-4)  
SW1-4 Output at the loss of communication  
OFF Reset the output (turned off)  
ON  
Hold the output (*)  
(maintains the last data received normally)  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 19/46  
http://www.m-system.co.jp/  
MODEL: R7C  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
terminal to ground.  
Caution: FG terminal is NOT a protective conductor  
terminal.  
4
Ry  
DA  
11  
12  
13  
14  
2
Y0  
Ry  
Ry  
Ry  
1
5
2
3
6
7
DB  
DG  
Y1  
Comm.  
Circuit  
Y2  
SLD  
Y3  
FG  
COM0  
COM0  
COM0  
COM0  
Y4  
24V DC  
0V  
3
4
5
Control  
Circuit  
Ry  
Ry  
Ry  
Ry  
15  
16  
17  
18  
6
Y5  
Y6  
Y7  
COM1  
COM1  
COM1  
COM1  
0V  
7
8
9
1
10 +24V  
Output Connection Example  
4 points / common  
8 points / common  
24 V DC  
24 V DC  
+
+
+
10  
1
10  
1
24V  
24V  
0V  
0V  
11  
11  
Y0  
Y0  
Y3 14  
Y3 14  
Y4 15  
Y7 18  
2
5
COM0  
COM0  
+
+
2
5
6
9
COM0  
COM0  
COM1  
COM1  
15  
Y4  
+
+
Y7 18  
6
9
COM1  
COM1  
+
+
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 20/46  
http://www.m-system.co.jp/  
MODEL: R7C  
RELAY CONTACT OUTPUT MODULE, 8 points  
MODEL: R7C-DC8E  
TERMINAL ASSIGNMENTS  
10  
+24 V  
11  
Y0  
12  
Y1  
13  
Y2  
14  
Y3  
15  
Y4  
16  
Y5  
17  
Y6  
9
18  
Y7  
1
2
3
4
5
6
7
8
0 V COM0 COM0 COM0 COM0 COM1 COM1 COM1 COM1  
SPECIFICATIONS  
NO. ID  
FUNCTION  
0 V 0 V  
COM0 Common 0  
NO. ID  
FUNCTION  
Common: 1 common per 4 points (4 terminals)  
Common current: Max. 8 A (4 terminals)  
Number of I/O: Relay contact output, 8 points  
Maximum outputs applicable at once: No limit (at 24 V DC)  
Output status indicator: LED turns ON with contact ON  
Isolation: Output to power input to CC-Link or FG  
CC-Link: Conforms to Version 1.10  
1
2
3
4
5
6
7
8
9
10 +24 V 24 V DC  
11  
12  
13  
14  
15  
16  
17  
18  
Y0 Output 0  
Y1 Output 1  
Y2 Output 2  
Y3 Output 3  
Y4 Output 4  
Y5 Output 5  
Y6 Output 6  
Y7 Output 7  
COM0 Common 0  
COM0 Common 0  
COM0 Common 0  
COM1 Common 1  
COM1 Common 1  
COM1 Common 1  
COM1 Common 1  
Station type: Remote I/O  
Data allocation: 1  
Relay driving power: 24 V DC ±10 %, ≥ 60 mA  
Rated load: 250 V AC @2 A (cos ø = 1)  
30 V DC @2 A (resistive load)  
Electrical life 10 cycles (rate 30/min.)  
5
Maximum switching voltage: 250 V AC or 30 V DC  
Maximum switching power: 500 VA or 60 W  
Minimum load: 24 V DC @5 mA  
Mechanical life: 2 × 10 cycles (rate 300/min.)  
7
When driving an inductive load, external contact protection  
and noise quenching are recommended.  
ON delay: ≤ 10 msec.  
OFF delay: ≤ 10 msec.  
OPERATING MODE SETTING  
(*) Factory setting  
Caution ! - SW1-6, 1-7, 1-8 are unused. Be sure to turn off  
unused ones.  
• Output at the Loss of Communication (SW1-5)  
SW1-5 Output at the loss of communication  
OFF Reset the output (turned off)  
ON  
Hold the output (*)  
(maintains the last data received normally)  
• Extension (SW1-1, 1-2, 1-3, 1-4)  
SW1-1 SW1-2 SW1-3 SW1-4 Extension  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF No extension (*)  
ON Discrete output, 8 or 16 points  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 21/46  
http://www.m-system.co.jp/  
MODEL: R7C  
CIRCUIT DIAGRAM  
Caution: FG terminal is NOT a protective conductor  
terminal.  
4
Ry  
DA  
11  
12  
13  
14  
2
Y0  
Ry  
1
5
2
3
6
7
DB  
DG  
Y1  
Comm.  
Circuit  
Ry  
Ry  
Y2  
SLD  
Y3  
FG  
COM0  
COM0  
COM0  
COM0  
Y4  
24V DC  
0V  
3
4
5
Control  
Circuit  
Ry  
Ry  
Ry  
Ry  
15  
16  
17  
18  
6
Y5  
Y6  
Y7  
COM1  
COM1  
COM1  
COM1  
0V  
7
8
9
1
10 +24V  
Output Connection Example  
4 points / common  
8 points / common  
24 V DC  
24 V DC  
+
+
+
10  
1
10  
1
24V  
24V  
0V  
0V  
11  
11  
Y0  
Y0  
Y3 14  
Y3 14  
Y4 15  
Y7 18  
2
5
COM0  
COM0  
+
+
2
5
6
9
COM0  
COM0  
COM1  
COM1  
15  
Y4  
+
+
Y7 18  
6
9
COM1  
COM1  
+
+
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 22/46  
http://www.m-system.co.jp/  
MODEL: R7C  
REMOTE CONTROL RELAY CONTROL MODULE  
MODEL: R7C-RR4  
TERMINAL ASSIGNMENTS  
6
7
8
9
10  
NC  
Y0  
Y1  
Y2 Y3  
1
2
3
4
5
NC C0  
C1  
C2  
C3  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
RECOMMENDED PRODUCTS (OPERATION CHECKED)  
Remote control relay:  
1
2
3
4
5
NC No connection  
C0 Common 0  
C1 Common 1  
C2 Common 2  
C3 Common 3  
6
7
NC No connection  
Y0 Output 0  
Y1 Output 1  
Y2 Output 2  
Y3 Output 3  
BR-12D, BR-22D (Mitsubishi Electric)  
WR6165 (Panasonic)  
8
9
10  
Remote control transformer:  
BRT-10B, BRT-20B (Mitsubishi Electric)  
WR2301 (Panasonic)  
CIRCUIT DIAGRAM  
Caution: FG terminal is NOT a protective conductor  
SPECIFICATIONS  
terminal.  
Common: 1 common per 4 points (4 terminals)  
Number of I/O: Output, 4 points  
Output Circuit  
Maximum outputs applicable at once: No limit  
I/O status indicator: Feedback input status turns on with the  
input supplied.  
4
1
5
2
3
6
7
7
2
DA  
DB  
Y0  
C0  
Y1  
C1  
Y2  
C2  
Y3  
C3  
Control  
Circuit  
Com.  
Circuit  
Output status LED turns on with the output ON.  
Isolation: Output to power input to CC-Link or FG  
CC-Link: Conforms to Version 1.10  
Station type: Remote I/O  
8
DG  
3
SLD  
FG  
9
Data allocation: 1  
4
U(+)  
V(–)  
Rated load voltage: 24 V AC ±10 % (supplied by the remote  
control transformer)  
10  
5
Load voltage frequency: 50 / 60 Hz  
1
6
OPERATING MODE SETTING  
Each output is set with 2 bits. Output setting is explained on  
the table below.  
Output Connection Example  
NO.  
BIT  
SETTING  
0, 0  
1, 0  
0, 1  
1, 1  
0, 0  
1, 0  
0, 1  
1, 1  
0, 0  
1, 0  
0, 1  
1, 1  
0, 0  
1, 0  
0, 1  
1, 1  
FUNCTION  
No operation  
Output 0 ON  
Output 0 OFF  
Invalid  
No operation  
Output 1 ON  
Output 1 OFF  
Invalid  
No operation  
Output 2 ON  
Output 2 OFF  
Invalid  
7
Y0  
C0  
blue  
Output 0  
8, 9  
Remote Control  
Transformer  
2
white  
red  
Remote Control  
Relay  
Output 1  
Output 2  
Output 3  
10, 11  
12, 13  
14, 15  
blue  
red  
10  
5
Y3  
C3  
Remote Control  
Relay  
blue  
No operation  
Output 3 ON  
Output 3 OFF  
Invalid  
Do not set both bits 1. If the 2 bits are simultaneously 1, the  
module will not operate normally.  
For repeating the output of ON pulse, after setting (0, 0), set  
(1, 0) once again.  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 23/46  
http://www.m-system.co.jp/  
MODEL: R7C  
• Extension (SW1-1, 1-2)  
DC VOLTAGE/CURRENT INPUT MODULE, 4 points  
SW1-1 SW1-2 Extension  
OFF  
ON  
OFF No extension (*)  
OFF Discrete input, 8 or 16 points  
ON Discrete output, 8 or 16 points  
MODEL: R7C-SV4  
OFF  
SPECIFICATIONS  
Isolation: Input 0 to input 1 to input 2 to input 3 to power  
TERMINAL ASSIGNMENTS  
input to CC-Link or FG  
10  
VL0  
11  
I0  
12  
VL1  
13  
I1  
14  
NC  
15  
VL2  
16  
I2  
17  
VL3  
18  
I3  
CC-Link: Conforms to Version 1.10  
Station type: Remote device  
1
2
3
4
5
6
7
8
9
VH0 COM0 VH1 COM1  
NC  
VH2 COM2 VH3 COM3  
Data allocation: 1  
Converted data range: 0 – 10000 of the input range  
Input range  
NO. ID  
FUNCTION  
VH0 Wide span volt. 0 10 VL0 Narrow span volt. 0  
COM0 Common 0 11 I0 Current range 0  
VH1 Wide span volt. 1 12 VL1 Narrow span volt. 1  
NO. ID  
FUNCTION  
1
2
3
4
5
6
7
8
9
Wide span voltage: -10 – +10 V DC, -5 – +5 V DC,  
0 – 10 V DC, 0 – 5 V DC, 1 – 5 V DC  
Narrow span voltage: -1 – +1 V DC, 0 – 1 V DC,  
-0.5 – +0.5 V DC  
COM1 Common 1  
NC No connection  
13  
14  
I1 Current range 1  
NC No connection  
Current range: -20 – +20 mA DC, 0 – 20 mA DC,  
4 – 20 mA DC  
VH2 Wide span volt. 2 15 VL2 Narrow span volt. 2  
COM2 Common 2 16 I2 Current range 2  
VH3 Wide span volt. 3 17 VL3 Narrow span volt. 3  
COM3 Common 3 18 I3 Current range 3  
Input resistance  
Wide span voltage: ≥ 1 MΩ  
Narrow span voltage: ≥ 100 kΩ  
Current range: 70 Ω  
Conversion rate / conversion accuracy:  
10 msec./±0.8 %, 20 msec./±0.4 %, 40 msec./±0.2 %,  
80 msec./±0.1 %  
Response time: Conversion rate × 2 + 50 msec. (0 – 90 %)  
Temperature coefficient: ±0.015 %/°C (±0.008 %/°F)  
OPERATING MODE SETTING  
(*) Factory setting  
• Input Range (SW1-5, 1-6, 1-7, 1-8)  
SW1-5 SW1-6 SW1-7 SW1-8 Input range  
OFF  
ON  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
-10 – +10 V DC (*)  
-5 – +5 V DC  
OFF  
ON  
-1 – +1 V DC  
ON  
0 – 10 V DC  
OFF  
ON  
OFF  
OFF  
ON  
0 – 5 V DC  
ON  
1 – 5 V DC  
OFF  
ON  
ON  
0 – 1V DC  
ON  
ON  
-0.5 – +0.5 V DC  
-20 – +20 mA DC  
4 – 20 mA DC  
0 – 20 mA DC  
PC Configurator setting  
ON  
OFF  
ON  
OFF  
OFF  
OFF  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
• Conversion Rate / Accuracy (SW1-3, 1-4)  
SW1-3 SW1-4 Conversion rate / Accuracy  
OFF  
ON  
OFF 80 msec. / 0.1ꢀ ꢁ*)  
OFF 40 msec. / 0.ꢂꢀ  
OFF  
ON  
ON  
ON  
ꢂ0 msec. / 0.4ꢀ  
10 msec. / 0.8ꢀ  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 24/46  
http://www.m-system.co.jp/  
MODEL: R7C  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
terminal to ground.  
Caution: FG terminal is NOT a protective conductor  
terminal.  
Input Circuit  
Input Circuit  
Input Circuit  
Input Circuit  
INPUT 0  
VH0  
1
10  
11  
2
4
1
5
2
3
6
7
DA  
VL0  
I0  
DB  
Comm.  
Circuit  
DG  
COM0  
SLD  
FG  
INPUT 1  
VH1  
3
12  
13  
4
24V DC  
0V  
VL1  
I1  
Control  
Circuit  
COM1  
INPUT 2  
VH2  
6
15  
16  
7
VL2  
I2  
COM2  
INPUT 3  
VH3  
8
17  
18  
9
VL3  
I3  
COM3  
5
14  
Input Connection Examples  
+
VHn  
VLn  
In  
VHn  
VLn  
In  
VHn  
+
+
VLn  
In  
WIDE SPAN  
VOLTAGE  
NARROW SPAN  
VOLTAGE  
CURRENT  
RANGE  
COMn  
COMn  
COMn  
Be sure to close across VLn and In terminals for a current input.  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 25/46  
http://www.m-system.co.jp/  
MODEL: R7C  
THERMOCOUPLE INPUT MODULE, 4 points  
MODEL: R7C-TS4  
OPERATING MODE SETTING  
(*) Factory setting  
• Thermocouple Type (SW1-5, 1-6, 1-7, 1-8)  
SW1-5 SW1-6 SW1-7 SW1-8 Thermocouple type  
OFF  
ON  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
K (CA) (*)  
E (CRC)  
SPECIFICATIONS  
Isolation: Input 0 to input 1 to input 2 to input 3 to power  
OFF  
ON  
J (IC)  
ON  
T (CC)  
input to CC-Link or FG  
OFF  
ON  
OFF  
OFF  
ON  
B (RH)  
CC-Link: Conforms to Version 1.10  
Station type: Remote device  
ON  
R
OFF  
ON  
ON  
S
Data allocation: 1  
ON  
ON  
C (WRe 5-26)  
Converted data range: Engineering unit value (°C, K) × 10  
(integer); No multiplication for °F  
Linearization: Standard  
OFF  
ON  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
N
ON  
U
OFF  
ON  
ON  
L
ON  
ON  
P (Platinel II)  
(PR)  
Thermocouple: K, E, J, T, B, R, S, C, N, U, L, P, PR  
Cold junction compensation: CJC sensor attached to the  
input terminals  
OFF  
ON  
OFF  
ON  
ON  
ON  
ON  
PC Configurator setting  
Input resistance: ≥ 30 kΩ  
• Conversion Rate (SW1-3)  
SW1-3 Conversion rate  
OFF 250 msec. (*)  
Burnout sensing: ≤ 0.1 μA  
Conversion accuracy: ±1°C (±1.8°F);  
±2.0°C (±3.6°F) for B, R, S, C, PR  
Conversion rate: 250 msec. or 500 msec.  
Response time: Conversion rate × 2 + 50 msec. (0 – 90 %)  
Temperature coefficient: ±0.015 %/°C (±0.008 %/°F) of  
max. span  
ON  
500 msec.  
• Burnout (SW1-4)  
SW1-4 Burnout  
OFF Upscale (*)  
ON  
Downscale  
• Extension (SW1-1, 1-2)  
CJC error: ±1.0°C at 25°C ±10°C  
(±1.8°F at 77°F ±18°F)  
SW1-1 SW1-2 Extension  
OFF  
ON  
OFF No extension (*)  
OFF Discrete input, 8 or 16 points  
ON Discrete output, 8 or 16 points  
±1.5°C (±2.7°F) for R, S, PR  
BURNOUT  
OFF  
T/C  
CONFORMANCE  
RANGE (°C)  
INDICATION (°C)  
Upscale  
+1472  
+1120  
+1300  
+ 500  
1920  
Downscale  
-272  
-272  
-260  
-272  
24  
K (CA)  
-150 to +1370  
-170 to +1000  
-180 to +1200  
-170 to + 400  
1000 to 1760  
380 to 1760  
400 to 1760  
100 to 2315  
-130 to +1300  
-200 to +600  
-200 to +900  
0 to 1395  
E (CRC)  
TERMINAL ASSIGNMENTS  
J (IC)  
T (CC)  
10  
11  
12  
13  
14  
NC  
15  
16  
17  
18  
B (RH)  
+IN0 –IN0 +IN1 –IN1  
+IN2 –IN2 +IN3 –IN3  
R
-100  
-100  
-52  
+1860  
+1860  
+2416  
+1400  
+ 700  
+1000  
+1496  
+1860  
1
2
3
4
5
6
7
8
9
S
+CJ0 –CJ0 +CJ1 –CJ1  
NC  
+CJ2 –CJ2 +CJ3 –CJ3  
C (WRe 5-26)  
N
-272  
-252  
-252  
-52  
NO. ID  
FUNCTION  
+CJ0 CJC + 0  
–CJ0 CJC – 0  
NO. ID  
FUNCTION  
U
1
2
3
4
5
6
7
8
9
10 +IN0 T/C + 0  
11 IN0 T/C – 0  
12 +IN1 T/C + 1  
13 –IN1 T/C – 1  
L
P (Platinel II)  
(PR)  
-52  
300 to 1760  
+CJ1 CJC + 1  
–CJ1 CJC – 1  
NC No connection  
+CJ2 CJC + 2  
–CJ2 CJC – 2  
+CJ3 CJC + 3  
–CJ3 CJC – 3  
BURNOUT  
INDICATION (°F)  
CONFORMANCE  
RANGE (°F)  
T/C  
14  
NC No connection  
Upscale  
+2682  
+2048  
+2372  
+932  
Downscale  
-458  
-458  
-436  
-458  
75  
15 +IN2 T/C + 2  
16 –IN2 T/C – 2  
17 +IN3 T/C + 3  
18 –IN3 T/C – 3  
K (CA)  
-238 to +2498  
-274 to +1832  
-292 to +2192  
-274 to +752  
1832 to 3200  
716 to 3200  
752 to 3200  
212 to 4199  
-202 to +2372  
-328 to +1112  
-328 to +1652  
32 to 2543  
E (CRC)  
J (IC)  
T (CC)  
B (RH)  
3488  
R
-148  
-148  
-62  
+3380  
+3380  
+4381  
+2552  
+1292  
+1832  
+2725  
+3380  
S
C (WRe 5-26)  
N
-458  
-422  
-422  
-62  
U
L
P (Platinel II)  
(PR)  
-62  
572 to 3200  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 26/46  
http://www.m-system.co.jp/  
MODEL: R7C  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
terminal to ground.  
Caution: FG terminal is NOT a protective conductor  
terminal.  
Input Circuit  
Input Circuit  
Input Circuit  
Input Circuit  
INPUT 0  
+IN0  
10  
11  
1
4
1
5
2
3
6
7
DA  
–IN0  
+CJ0  
–CJ0  
DB  
Comm.  
Circuit  
DG  
2
SLD  
FG  
INPUT 1  
+IN1  
12  
13  
3
24V DC  
0V  
–IN1  
+CJ1  
–CJ1  
Control  
Circuit  
4
INPUT 2  
+IN2  
15  
16  
6
–IN2  
+CJ2  
–CJ2  
7
INPUT 3  
+IN3  
17  
18  
8
–IN3  
+CJ3  
–CJ3  
9
5
14  
Input Connection Example  
T/C  
+
+INn  
–INn  
+CJn  
–CJn  
CJC  
SENSOR  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 27/46  
http://www.m-system.co.jp/  
MODEL: R7C  
RTD INPUT MODULE, 4 points  
MODEL: R7C-RS4  
OPERATING MODE SETTING  
(*) Factory setting  
• RTD Type (SW1-5, 1-6, 1-7, 1-8)  
SW1-5 SW1-6 SW1-7 SW1-8  
RTD Type  
OFF  
ON  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
OFF Pt 100 (JIS ’97, IEC) (*)  
OFF Pt 100 (JIS ’89)  
OFF JPt 100 (JIS ’89)  
OFF Pt 50 Ω (JIS ’81)  
OFF Ni 100  
SPECIFICATIONS  
Isolation: Input 0 to input 1 to input 2 to input 3 to power  
OFF  
ON  
ON  
input to CC-Link or FG  
OFF  
ON  
OFF  
OFF  
OFF  
ON  
CC-Link: Conforms to Version 1.10  
Station type: Remote device  
ON  
OFF Cu 10 @ 25°C  
OFF  
ON  
OFF  
ON  
ON  
ON  
Cu 50  
Data allocation: 1  
PC Configurator setting  
Converted data range: Engineering unit value (°C, K) × 10  
(integer); No multiplication for °F  
Linearization: Standard  
• Conversion Rate (SW1-3)  
SW1-3 Conversion rate  
OFF 250 msec. (*)  
RTD: Pt 100 (JIS ’97, IEC), Pt 100 (JIS ’89), JPt 100 (JIS ’89),  
Pt 50 Ω (JIS ’81), Ni 100, Cu 10, Cu 50  
Sensing current: ≤ 1 mA  
ON  
500 msec.  
• Burnout (SW1-4)  
SW1-4 Burnout  
OFF Upscale (*)  
Input resistance: ≥ 1 MΩ  
Maximum leadwire resistance: 100 Ω per wire  
Conversion accuracy: ±1°C (±1.8°F);  
±3°C (±5.4°F) for Cu 10  
ON  
Downscale  
• Extension (SW1-1, 1-2)  
SW1-1 SW1-2 Extension  
Conversion rate: 250 msec. or 500 msec.  
Response time: Conversion rate × 2 + 50 msec. (0 – 90 %)  
Temperature coefficient: ±0.015 %/°C (±0.008 %/°F) of  
max. span  
OFF  
ON  
OFF No extension (*)  
OFF Discrete input, 8 or 16 points  
ON Discrete output, 8 or 16 points  
OFF  
BURNOUT INDICATION (°C) CONFORMANCE  
RTD  
Downscale  
-240  
-240  
-236  
-236  
-100  
Upscale  
+900  
+900  
+560  
+700  
+252  
+312  
+200  
RANGE (°C)  
-200 to +850  
-200 to +660  
-200 to +510  
-200 to +649  
-80 to +250  
-50 to +250  
-50 to +150  
TERMINAL ASSIGNMENTS  
Pt 100 (JIS ’97, IEC)  
Pt 100 (JIS ’89)  
JPt 100 (JIS ’89)  
Pt 50 Ω (JIS ’81)  
Ni 100  
10  
11  
12  
13  
14  
NC  
15  
16  
17  
18  
INA0 INb0 INA1 INb1  
INA2 INb2 INA3 INb3  
1
2
3
4
5
6
7
8
9
NC  
INB0  
NC  
INB1  
NC  
NC  
INB2  
NC  
INB3  
Cu 10 @ 25°C  
Cu 50  
-212  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
-100  
1
2
3
4
5
6
7
8
9
NC No connection  
INB0 RTD 0-B  
10 INA0 RTD 0-A  
11 INb0 RTD 0-b  
12 INA1 RTD 1-A  
13 INb1 RTD 1-b  
BURNOUT INDICATION (°F) CONFORMANCE  
RTD  
NC No connection  
INB1 RTD 1-B  
Downscale  
-400  
-400  
-393  
-393  
-148  
Upscale  
+1652  
+1652  
+1040  
+1292  
+486  
RANGE (°F)  
-328 to +1562  
-328 to +1220  
-328 to +950  
-328 to +1200  
-112 to +482  
-58 to +482  
Pt 100 (JIS ’97, IEC)  
Pt 100 (JIS ’89)  
JPt 100 (JIS ’89)  
Pt 50 Ω (JIS ’81)  
Ni 100  
NC No connection  
NC No connection  
INB2 RTD 2-B  
14  
NC No connection  
15 INA2 RTD 2-A  
16 INb2 RTD 2-b  
17 INA3 RTD 3-A  
18 INb3 RTD 3-b  
NC No connection  
INB3 RTD 3-B  
Cu 10 @ 25°C  
Cu 50  
-350  
-148  
+594  
+392  
-58 to +302  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 28/46  
http://www.m-system.co.jp/  
MODEL: R7C  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
terminal to ground.  
Caution: FG terminal is NOT a protective conductor  
terminal.  
Input Circuit  
Input Circuit  
Input Circuit  
Input Circuit  
INPUT 0  
INA0  
10  
2
4
1
5
2
3
6
7
DA  
INB0  
INb0  
DB  
Comm.  
Circuit  
11  
DG  
INPUT 1  
INA1  
SLD  
FG  
12  
4
INB1  
INb1  
24V DC  
0V  
13  
Control  
Circuit  
INPUT 2  
INA2  
15  
7
INB2  
INb2  
16  
INPUT 3  
INA3  
17  
9
INB3  
INb3  
18  
1
3
5
6
8
14  
Input Connection Example  
RTD  
INAn  
A
INBn  
B
INbn  
B
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 29/46  
http://www.m-system.co.jp/  
MODEL: R7C  
THERMISTOR INPUT MODULE, 4 points  
MODEL: R7C-RT4A  
TERMINAL ASSIGNMENTS  
10  
INA0  
11  
NC  
12  
INA1  
13  
NC  
14  
NC  
15  
INA2  
16  
NC  
17  
INA3  
18  
NC  
1
2
3
4
5
6
7
8
9
NC  
INB0  
NC  
INB1  
NC  
NC  
INB2  
NC  
INB3  
SPECIFICATIONS  
Isolation: Input 0 to input 1 to input 2 to input 3 to power  
NO. ID  
FUNCTION  
NO. ID  
10 INA0 Thermistor 0-A  
11  
12 INA1 Thermistor 1-A  
FUNCTION  
1
2
3
4
5
6
7
8
9
NC No connection  
INB0 Thermistor 0-B  
NC No connection  
INB1 Thermistor 1-B  
NC No connection  
NC No connection  
INB2 Thermistor 2-B  
NC No connection  
INB3 Thermistor 3-B  
input to CC-Link or FG  
No connection  
NC  
CC-Link: Conforms to Version 1.10  
Station type: Remote device  
13  
14  
No connection  
NC No connection  
NC  
Data allocation: 1  
15 INA2 Thermistor 2-A  
16  
17 INA3 Thermistor 3-A  
18  
Converted data range: Engineering unit value (°C, K) × 10  
(integer); No multiplication for °F  
No connection  
NC  
Thermistor: 502AT-11/502AT-2 (SEMITEC Corporation)  
Excitation: Approx. 4.5 V DC (sensing resistance 15.8 kΩ)  
Input resistance: ≥ 1 MΩ  
No connection  
NC  
Burnout response time: ≤ 2 sec.  
CIRCUIT DIAGRAM  
Conversion accuracy: ±0.5°C (±0.9°F)  
Conversion rate: 250 msec. or 500 msec.  
Response time: Conversion rate × 2 + 50 msec. (0 – 90 %)  
Temperature coefficient: ±0.15 %/°C (±0.08 %/°F)  
Caution: FG terminal is NOT a protective conductor  
terminal.  
Input Circuit  
Input Circuit  
Input Circuit  
Input Circuit  
INPUT 0  
INA0  
10  
4
1
5
2
3
6
7
DA  
THERMISTOR  
BURNOUT INDICATION CONFORMANCE RANGE  
Downscale Upscale  
DB  
Comm.  
Circuit  
2
INB0  
DG  
(
°C)  
-50  
-58  
+110  
+230  
-40 to +90  
502AT-11  
502AT-2  
INPUT 1  
INA1  
SLD  
FG  
(°F)  
-40 to +194  
12  
24V DC  
0V  
4
INB1  
Control  
Circuit  
INPUT 2  
INA2  
15  
OPERATING MODE SETTING  
(*) Factory setting  
Caution ! - SW1-5, 1-6, 1-7, 1-8 are unused. Be sure to turn  
off unused ones.  
7
INB2  
INPUT 3  
INA3  
17  
• Conversion Rate (SW1-3)  
SW1-3 Conversion rate  
OFF 250 msec. (*)  
9
1
INB3  
ON  
500 msec.  
• Burnout (SW1-4)  
SW1-4 Burnout  
OFF Upscale (*)  
3
5
6
ON  
Downscale  
8
• Extension (SW1-1, 1-2)  
11  
13  
14  
16  
18  
SW1-1 SW1-2 Extension  
OFF  
ON  
OFF No extension (*)  
OFF Discrete input, 8 or 16 points  
ON Discrete output, 8 or 16 points  
OFF  
Input Connection Example  
Thermistor  
A
INAn  
B
INBn  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 30/46  
http://www.m-system.co.jp/  
MODEL: R7C  
POTENTIOMETER INPUT MODULE, 4 points  
MODEL: R7C-MS4  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
terminal to ground.  
Caution: FG terminal is NOT a protective conductor  
terminal.  
SPECIFICATIONS  
Isolation: Input 0 to input 1 to input 2 to input 3 to power  
Input Circuit  
Input Circuit  
Input Circuit  
Input Circuit  
INPUT 0  
H0  
10  
11  
2
4
1
5
2
3
6
7
Exc.  
Exc.  
Exc.  
Exc.  
DA  
input to CC-Link or FG  
S0  
L0  
DB  
CC-Link: Conforms to Version 1.10  
Comm.  
Circuit  
Station type: Remote device  
DG  
Data allocation: 1  
INPUT 1  
H1  
SLD  
FG  
12  
13  
4
Converted data range: 0 – 10000 of the input range  
Potentiometer: Total resistance 100 Ω – 20 kΩ  
Minimum span: 50 % of total resistance  
Excitation: Approx. 0.2 V DC  
S1  
L1  
24V DC  
0V  
Control  
Circuit  
INPUT 2  
H2  
15  
16  
7
Conversion rate / conversion accuracy:  
10 msec./±0.8 %, 20 msec./±0.4 %, 40 msec./±0.2 %,  
80 msec./±0.1 %  
S2  
L2  
INPUT 3  
H3  
17  
18  
9
Response time: Conversion rate × 2 + 50 msec. (0 – 90 %)  
Temperature coefficient: ±0.015 %/°C (±0.008 %/°F)  
S3  
L3  
1
OPERATING MODE SETTING  
(*) Factory setting  
3
Caution ! - SW1-5, 1-6, 1-7, 1-8 are unused. Be sure to turn  
off unused ones.  
5
6
• Conversion Rate / Accuracy (SW1-3, 1-4)  
8
SW1-3 SW1-4 Conversion rate / Accuracy  
14  
OFF  
ON  
OFF 80 msec. / 0.1ꢀ ꢁ*)  
OFF 40 msec. / 0.ꢂꢀ  
OFF  
ON  
ON  
ON  
ꢂ0 msec. / 0.4ꢀ  
10 msec. / 0.8ꢀ  
Input Connection Example  
POTENTIOMETER  
max.  
+
Hn  
Sn  
Ln  
3
2
1
• Extension (SW1-1, 1-2)  
SW1-1 SW1-2 Extension  
OFF  
ON  
OFF No extension (*)  
OFF Discrete input, 8 or 16 points  
ON Discrete output, 8 or 16 points  
min.  
OFF  
TERMINAL ASSIGNMENTS  
10  
H0  
11  
S0  
12  
H1  
13  
S1  
14  
NC  
15  
H2  
16  
S2  
17  
H3  
18  
S3  
1
2
3
4
5
6
7
8
9
NC  
L0  
NC  
L1  
NC  
NC  
L2  
NC  
L3  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
1
2
3
4
5
6
7
8
9
NC No connection  
L0 Pot L0  
10  
11  
12  
13  
14  
15  
16  
17  
18  
H0 Pot H0  
S0 Pot S0  
H1 Pot H1  
S1 Pot S1  
NC No connection  
H2 Pot H2  
S2 Pot S2  
H3 Pot H3  
S3 Pot S3  
NC No connection  
L1 Pot L1  
NC No connection  
NC No connection  
L2 Pot L2  
NC No connection  
L3 Pot L3  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 31/46  
http://www.m-system.co.jp/  
MODEL: R7C  
• Extension (SW1-1, 1-2)  
AC CURRENT INPUT MODULE, 4 points  
(clamp-on current sensor CLSE use)  
SW1-1 SW1-2 Extension  
OFF  
ON  
OFF No extension (*)  
OFF Discrete input, 8 or 16 points  
ON Discrete output, 8 or 16 points  
OFF  
MODEL: R7C-CT4E  
SPECIFICATIONS  
Isolation: Input 0 to input 1 to input 2 to input 3 to power  
TERMINAL ASSIGNMENTS  
10  
K0  
11  
L0  
12  
K1  
13  
L1  
14  
NC  
15  
K2  
16  
L2  
17  
K3  
18  
L3  
input to CC-Link or FG  
CC-Link: Conforms to Version 1.10  
Station type: Remote device  
1
2
3
4
5
6
7
8
9
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
Data allocation: 1  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
Converted data range:  
1
2
3
4
5
6
7
8
9
NC No connection  
NC No connection  
NC No connection  
NC No connection  
NC No connection  
NC No connection  
NC No connection  
NC No connection  
NC No connection  
10  
11  
12  
13  
14  
15  
16  
17  
18  
K0 AC current K0  
L0 AC current L0  
K1 AC current K1  
L1 AC current L1  
NC No connection  
K2 AC current K2  
L2 AC current L2  
K3 AC current K3  
L3 AC current L3  
Engineering unit value (A) × 100 (Integer)  
(Engineering unit value (A) × 1000 (Integer) for CLSE-R5)  
Input range (Optional)  
CLSE-R5: 0 – 5 A AC  
CLSE-05: 0 – 50 A AC  
CLSE-10: 0 – 100 A AC  
CLSE-20: 0 – 200 A AC  
CLSE-40: 0 – 400 A AC  
CLSE-60: 0 – 600 A AC  
Frequency: 50/60 Hz  
Overload capacity: 120 % continuous  
Operational range: 5 – 115 % of rating (Operational range  
for the CLSE-60 is limited up to approx. 109 % (65535).)  
(Note: Use for the circuit not exceed 480 V)  
Conversion rate / conversion accuracy:  
10 msec./±2.0 %, 20 msec./±1.0 %, 40 msec./±0.5 %,  
80 msec./±0.5 %  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
terminal to ground.  
Caution: FG terminal is NOT a protective conductor  
terminal.  
Input Circuit  
INPUT 0  
10  
4
1
5
2
3
6
7
K0  
DA  
(The conversion accuracy does not include the accuracy of  
the sensor.)  
11  
L0  
DB  
Comm.  
Circuit  
Input Circuit  
Input Circuit  
Input Circuit  
INPUT 1  
K1  
DG  
12  
13  
Response time: ≤ 1.0 sec. (0 – 90 %)  
Temperature coefficient: ±0.015 %/°C (±0.008 %/°F)  
SLD  
FG  
L1  
Control  
Circuit  
INPUT 2  
K2  
15  
16  
24V DC  
0V  
L2  
OPERATING MODE SETTING  
(*) Factory setting  
INPUT 3  
K3  
17  
18  
1
L3  
• Input Range (SW1-5, 1-6, 1-7, 1-8)  
SW1-5 SW1-6 SW1-7 SW1-8 Input range  
2
OFF  
ON  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
OFF CLSE-60 (*)  
OFF CLSE-40  
OFF CLSE-20  
OFF CLSE-10  
OFF CLSE-05  
OFF CLSE-R5  
3
4
OFF  
ON  
5
ON  
6
OFF  
ON  
OFF  
OFF  
ON  
7
ON  
8
ON  
ON  
ON  
PC Configurator setting  
9
• Conversion Rate / Accuracy (SW1-3, 1-4)  
14  
SW1-3 SW1-4 Conversion rate / Accuracy  
OFF  
ON  
OFF 80 msec. / 0.ꢀ5 ꢁ*)  
Input Connection Example  
SOURCE  
OFF 40 msec. / 0.ꢀ5  
k
Kn  
OFF  
ON  
ON  
ON  
20 msec. / 1.05  
10 msec. / 2.05  
CLAMP-ON SENSOR  
Ln  
l
LOAD  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 32/46  
http://www.m-system.co.jp/  
MODEL: R7C  
• Extension (SW1-1, 1-2)  
TOTALIZED PULSE INPUT MODULE, 8 points  
MODEL: R7C-PA8  
SW1-1 SW1-2 Extension  
OFF  
ON  
OFF No extension (*)  
OFF Discrete input, 8 or 16 points  
ON Discrete output, 8 or 16 points  
OFF  
SPECIFICATIONS  
Common: Positive or negative common (NPN/PNP) per  
TERMINAL ASSIGNMENTS  
8 points  
10  
11  
12  
13  
14  
15  
16  
17  
18  
Number of I/O: Input, 8 points  
VPI0 PI1 PI2 PI3 PI4 PI5 PI6 PI7  
1
2
3
4
5
6
7
8
9
Pulse Input status indicator: LED turns ON with contact ON  
Isolation: Input to power input to CC-Link or FG  
CC-Link: Conforms to Version 1.10  
Station type: Remote device  
VC0  
C1  
C2  
C3  
C4  
C5  
C6  
C7  
NO.  
ID  
FUNCTION  
NO. ID  
FUNCTION  
Data allocation: 1 or 4  
1
2
3
4
5
6
7
8
9
V –  
C0  
C1  
C2  
C3  
C4  
C5  
C6  
C7  
Power (–)  
Common  
Common  
Common  
Common  
Common  
Common  
Common  
Common  
10  
11  
12  
13  
14  
15  
16  
17  
18  
V +  
PI0  
PI1  
PI2  
PI3  
PI4  
PI5  
PI6  
PI7  
Power (+)  
Input 0  
Input 1  
Input 2  
Input 3  
Input 4  
Input 5  
Input 6  
Input 7  
■ External excitation (PNP, NPN input)  
Sensing voltage: 24 V DC ±10 %; ripple 5 %p-p max  
ON voltage / ON current: ≥ 16 V DC (input terminal - Cx) /  
≤ 3.7 mA  
OFF voltage / OFF current: ≤ 5 V DC (input terminal - Cx) /  
≤ 1 mA  
Voltage pulse input  
ON voltage / ON current: ≥ 16 V DC (input terminal - Cx) /  
≤ 3.7 mA  
OFF voltage / OFF current: ≤ 5 V DC (input terminal - Cx) /  
≤ 1 mA  
Input current: ≤ 5.5 mA per point at 24 V DC  
Input resistance: Approx. 4.4 kΩ  
ON delay: ≤ 2.0 msec.  
OFF delay: ≤ 2.0 msec.  
Max. Frequency: 100 Hz (This unit is designed to be able to  
accept a frequency up to 100 Hz, however,‘chattering’  
contact must be avoided for accurate measuring of such  
high frequency. Use relays that do not cause any  
chattering.)  
Minimum ON/OFF pulse requirements: 5 ms  
Accumulated pulse count: 0 - 4 294 967 295  
Max. accumulated pulse count: 1 000 - 4 294 967 295  
(Factory default: 4 294 967 295)  
Overflow: 0 or 1 (Factory default: 0)  
OPERATING MODE SETTING  
(*) Factory setting  
Note: SW1-4 through SW1-8 are unused. Be sure to turn off  
unused ones.  
• Data Allocation (SW1-3)  
SW1-3D  
OFF  
Data allocation  
1 (*)  
ON  
4
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 33/46  
http://www.m-system.co.jp/  
MODEL: R7C  
CIRCUIT DIAGRAM  
Caution: FG terminal is NOT a protective conductor  
terminal.  
Input Circuit  
10  
1
4
1
5
2
3
6
7
V+  
V–  
DA  
DB  
Comm.  
Circuit  
11  
12  
13  
14  
15  
16  
17  
18  
2
PI0  
PI1  
PI2  
PI3  
PI4  
PI5  
PI6  
PI7  
C0  
C1  
C2  
C3  
C4  
C5  
C6  
C7  
DG  
SLD  
FG  
U (+)  
V (–)  
Control  
Circuit  
3
4
5
6
7
8
9
Input Circuit  
10  
1
V+  
V–  
11  
2
PI0  
C0  
Control  
Circuit  
18  
9
PI7  
C7  
Input Connection Examples  
PNP connection  
NPN connection  
Voltage Pulse Input  
+
+
10  
1
10  
1
10  
1
V+  
V–  
V+  
V–  
V+  
Connected  
V–  
11  
2
11  
2
11  
2
PI0  
C0  
PI0  
C0  
+
PI0  
C0  
18  
9
18  
9
18  
9
PI7  
C7  
PI7  
C7  
+
PI7  
C7  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 34/46  
http://www.m-system.co.jp/  
MODEL: R7C  
DC VOLTAGE OUTPUT MODULE, 2 points  
MODEL: R7C-YV2  
TERMINAL ASSIGNMENTS  
6
7
8
9
10  
VL1  
NC  
VH0  
VL0  
VH1  
1
2
3
4
5
NC  
COM0 COM0 COM1 COM1  
SPECIFICATIONS  
Isolation: Output 0 to output 1 to power input to CC-Link or  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
1
2
3
4
5
NC No connection  
COM0 Common 0  
COM0 Common 0  
COM1 Common 1  
COM1 Common 1  
6
7
8
9
NC No connection  
FG  
VH0 Wide span volt. 0  
VL0 Narrow span volt. 0  
VH1 Wide span volt. 1  
CC-Link: Conforms to Version 1.10  
Station type: Remote device  
10 VL1 Narrow span volt. 1  
Data allocation: 1  
Converted data range: 0 – 10000 of the output range  
Output range  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
Wide span voltage: -10 – +10 V DC, -5 – +5 V DC,  
0 – 10 V DC, 0 – 5 V DC, 1 – 5 V DC  
Narrow span voltage: -1 – +1 V DC, 0 – 1 V DC,  
-0.5 – +0.5 V DC  
terminal to ground.  
Caution: FG terminal is NOT a protective conductor  
terminal.  
Operational range: -11.5 – +11.5 V DC or -15 – +115 %  
Load resistance: ≥ 100 kΩ  
Output Circuit  
OUTPUT 0  
VH0  
Conversion accuracy: ±0.1 %  
4
1
5
2
3
6
7
7
8
2
3
DA  
DB  
Response time: 250 msec. (0 – 90 %)  
Temperature coefficient: ±0.015 %/°C (±0.008 %/°F)  
VL0  
Comm.  
Circuit  
DG  
COM0  
COM0  
SLD  
FG  
Control  
Circuit  
OPERATING MODE SETTING  
(*) Factory setting  
Output Circuit  
OUTPUT 1  
VH1  
9
10  
4
24V DC  
0V  
VL1  
Caution ! - SW1-3 is unused. Be sure to turn off unused  
ones.  
COM1  
COM1  
• Output Range (SW1-5, 1-6, 1-7, 1-8)  
5
SW1-5 SW1-6 SW1-7 SW1-8 Output range  
1
OFF  
ON  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
-10 – +10 V DC (*)  
-5 – +5 V DC  
6
OFF  
ON  
-1 – +1 V DC  
ON  
0 – 10 V DC  
OFF  
ON  
OFF  
OFF  
ON  
0 – 5 V DC  
ON  
1 – 5 V DC  
OFF  
ON  
ON  
0 – 1 V DC  
Output Connection Examples  
ON  
ON  
-0.5 – +0.5 V DC  
PC Configurator setting  
ON  
ON  
ON  
+
VHn  
VLn  
VHn  
WIDE SPAN  
VOLTAGE  
+
VLn  
• Output at the Loss of Communication (SW1-4)  
SW1-4 Output at the loss of communication  
NARROW SPAN  
VOLTAGE  
COMn  
COMn  
OFF Reset the output (to -15% or approx. -11.5V DC)  
ON  
Hold the output (*)  
(maintains the last data received normally)  
• Extension (SW1-1, 1-2)  
SW1-1 SW1-2 Extension  
OFF  
ON  
OFF No extension (*)  
OFF Discrete input, 8 or 16 points  
ON Discrete output, 8 or 16 points  
OFF  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 35/46  
http://www.m-system.co.jp/  
MODEL: R7C  
DC VOLTAGE OUTPUT MODULE, 4 points  
MODEL: R7C-YV4  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
terminal to ground.  
Caution: FG terminal is NOT a protective conductor  
terminal.  
SPECIFICATIONS  
Isolation: Output 0 to output 1 to output 2 to output 3 to  
Output Circuit  
OUTPUT 0  
V0  
power input to CC-Link or FG  
4
1
5
2
3
6
7
7
2
DA  
DB  
CC-Link: Conforms to Version 1.10  
Station type: Remote device  
COM0  
Control  
Circuit  
Output Circuit  
Output Circuit  
Output Circuit  
Comm.  
Circuit  
OUTPUT 1  
V1  
DG  
8
3
Data allocation: 1  
SLD  
FG  
Converted data range: 0 – 10000 of the output range  
Output rang: -10 - +10V DC, -5 - +5V DC, 0 - 10V DC,  
0 - 5V DC, 1 - 5V DC  
COM1  
OUTPUT 2  
V2  
9
4
U(+)  
V(–)  
Operational range: -11.5 – +11.5 V DC or -15 – +115 %  
Load resistance: ≥ 20 kΩ  
COM2  
OUTPUT 3  
V3  
Conversion accuracy: ±0.1 %  
10  
5
Response time: 250 msec. (0 – 90 %)  
Temperature coefficient: ±0.015 %/°C (±0.008 %/°F)  
COM3  
1
6
OPERATING MODE SETTING  
(*) Factory setting  
Caution ! - SW1-1, SW1-2 and SW1-3 are unused. Be sure to  
turn off unused ones.  
Output Range (SW1-5, 1-6, 1-7, 1-8)  
SW1-5 SW1-6 SW1-7 SW1-8 Output range  
OFF  
ON  
ON  
OFF  
ON  
ON  
OFF  
OFF  
ON  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
ON  
ON  
ON  
OFF -10 – +10V DC (*)  
OFF -5 – +5V DC  
OFF 0 – 10V DC  
OFF 0 – 5V DC  
OFF 1 – 5V DC  
ON  
PC Con!gurator setting  
• Output at the Loss of Communication (SW1-4)  
SW1-4 Output at the loss of communication  
OFF Reset the output (to -15% or approx. -11.5V DC)  
ON  
Hold the output (*)  
(maintains the last data received normally)  
TERMINAL ASSIGNMENTS  
6
7
8
9
10  
V3  
NC  
V0  
V1  
V2  
1
2
3
4
5
NC COM0 COM1 COM2 COM3  
NO.  
1
ID  
FUNCTION  
No connection  
Common 0  
Common 1  
Common 2  
Common 3  
NO.  
6
ID  
NC  
V0  
V1  
V2  
V3  
FUNCTION  
NC  
No connection  
2
COM0  
COM1  
COM2  
COM3  
7
Voltage Output 0  
Voltage Output 1  
Voltage Output 2  
Voltage Output 3  
3
8
4
9
5
10  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 36/46  
http://www.m-system.co.jp/  
MODEL: R7C  
DC CURRENT OUTPUT MODULE, 2 points  
MODEL: R7C-YS2  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
terminal to ground.  
Caution: FG terminal is NOT a protective conductor  
terminal.  
SPECIFICATIONS  
Isolation: Output 0 to output 1 to power input to CC-Link or  
Output Circuit  
OUTPUT 0  
I0  
FG  
4
1
5
2
3
6
7
7
2
DA  
DB  
CC-Link: Conforms to Version 1.10  
Station type: Remote device  
COM0  
Control  
Circuit  
Output Circuit  
Comm.  
Circuit  
OUTPUT 1  
I1  
DG  
9
4
Data allocation: 1  
SLD  
FG  
Converted data range: 0 – 10000 of the output range  
Output range: 4 – 20 mA DC  
COM1  
1
Load resistance: ≤ 600Ω  
24V DC  
0V  
3
Conversion accuracy: ±0.1 %  
5
Response time: 250 msec. (0 – 90 %)  
Temperature coefficient: ±0.015 %/°C (±0.008 %/°F)  
6
8
10  
OPERATING MODE SETTING  
(*) Factory setting  
Caution ! - SW1-3, 1-5 through 1-8 are unused. Be sure to  
turn off unused ones.  
• Output at the Loss of Communication (SW1-4)  
SW1-4 Output at the loss of communication  
OFF Reset the output (to -15%)  
ON  
Hold the output (*)  
(maintains the last data received normally)  
• Extension (SW1-1, 1-2)  
SW1-1 SW1-2 Extension  
OFF  
ON  
OFF No extension (*)  
OFF Discrete input, 8 or 16 points  
ON Discrete output, 8 or 16 points  
OFF  
TERMINAL ASSIGNMENTS  
6
7
8
9
10  
NC  
NC  
I0  
NC  
I1  
1
2
3
4
5
NC  
COM0  
NC  
COM1  
NC  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
1
2
3
4
5
NC No connection  
COM0 Common 0  
NC No connection  
COM1 Common 1  
NC No connection  
6
7
NC No connection  
I0 Current 0  
8
NC No connection  
I1 Current 1  
9
10  
NC No connection  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 37/46  
http://www.m-system.co.jp/  
MODEL: R7C  
DC CURRENT OUTPUT MODULE, 4 points  
MODEL: R7C-YS4  
CIRCUIT DIAGRAM  
Note: In order to improve EMC performance, bond the FG  
terminal to ground.  
Caution: FG terminal is NOT a protective conductor  
terminal.  
SPECIFICATIONS  
Isolation: Output 0 to output 1 to output 2 to output 3 to  
Output Circuit  
OUTPUT 0  
I0  
power input to CC-Link or FG  
4
1
5
2
3
6
7
7
2
DA  
DB  
CC-Link: Conforms to Version 1.10  
Station type: Remote device  
COM0  
Control  
Circuit  
Output Circuit  
Output Circuit  
Output Circuit  
Comm.  
Circuit  
OUTPUT 1  
I1  
DG  
8
3
Data allocation: 1  
SLD  
FG  
Converted data range: 0 – 10000 of the output range  
Output range: 4 – 20 mA DC  
COM1  
OUTPUT 2  
I2  
Load resistance: ≤ 550Ω  
9
4
U(+)  
V(–)  
Conversion accuracy: ±0.1 %  
COM2  
Response time: 250 msec. (0 – 90 %)  
Temperature coefficient: ±0.015 %/°C (±0.008 %/°F)  
OUTPUT 3  
I3  
10  
5
COM3  
OPERATING MODE SETTING  
(*) Factory setting  
1
6
Caution ! - SW1-1 through 1-3, 1-5 through 1-8 are unused.  
Be sure to turn off the unused ones.  
• Output at the Loss of Communication (SW1-4)  
SW1-4 Output at the loss of communication  
OFF Reset the output (to -15%)  
ON  
Hold the output (*)  
(maintains the last data received normally)  
TERMINAL ASSIGNMENTS  
6
7
8
9
10  
I3  
NC  
I0  
I1  
I2  
1
2
3
4
5
NC  
COM0 COM1 COM2 COM3  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
1
2
3
4
5
NC No connection  
COM0 Common 0  
COM1 Common 1  
COM2 Common 2  
COM3 Common 3  
6
7
NC No connection  
I0 Current 0  
I1 Current 1  
I2 Current 2  
I3 Current 3  
8
9
10  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 38/46  
http://www.m-system.co.jp/  
MODEL: R7C  
DISCRETE INPUT EXTENSION MODULE, 8 points  
CIRCUIT DIAGRAM  
MODEL: R7C-EA8  
Input Circuit  
1
2
3
4
5
7
8
9
10  
6
COM  
X0  
SPECIFICATIONS  
Common: Positive or negative common (NPN/PNP) per  
X2  
8 points  
X4  
Number of I/O: Input, 8 points  
X6  
Control  
Circuit  
Maximum inputs applicable at once: No limit (at 24 V DC)  
Input status indicator: LED turns ON with contact ON  
Isolation: Input to internal circuits  
X1  
X3  
Rated input voltage: 24 V DC ±10 %; ripple 5 %p-p max.  
ON voltage / current: ≥ 15 V DC (input – COM) / ≥ 3.5 mA  
OFF voltage / current: ≤ 5 V DC (input – COM) / ≤ 1 mA  
Input current: ≤ 5.5 mA per point at 24 V DC  
Input resistance: Approx. 4.4 kΩ  
X5  
X7  
ON delay: ≤ 2.0 msec.  
OFF delay: ≤ 2.0 msec.  
Input Circuit  
1
2
COM  
X0  
TERMINAL ASSIGNMENTS  
6
7
8
9
10  
X7  
NC  
X1  
X3  
X5  
1
2
3
4
5
Control  
Circuit  
COM  
X0  
X2  
X4  
X6  
NO. ID  
FUNCTION  
COM Common  
X0 Input 0  
NO. ID  
FUNCTION  
1
2
3
4
5
6
7
NC No Connection  
X1 Input 1  
10  
X7  
X2 Input 2  
X4 Input 4  
X6 Input 6  
8
X3 Input 3  
9
X5 Input 5  
10  
X7 Input 7  
Input Connection Examples  
PNP Connection  
NPN Connection  
+
– +  
1
2
1
2
COM  
X0  
COM  
X0  
10  
10  
X7  
X7  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 39/46  
http://www.m-system.co.jp/  
MODEL: R7C  
DISCRETE INPUT EXTENSION MODULE, 16 points  
CIRCUIT DIAGRAM  
Input Circuit  
MODEL: R7C-EA16  
1
2
COM  
X0  
X2  
X4  
X6  
X8  
XA  
XC  
XE  
X1  
X3  
X5  
X7  
X9  
XB  
XD  
XF  
SPECIFICATIONS  
Common: Positive or negative common (NPN/PNP) per  
3
4
16 points  
5
Number of I/O: Input, 16 points  
Maximum inputs applicable at once: No limit (at 24 V DC)  
Input status indicator: LED turns ON with contact ON  
Isolation: Input to internal circuits  
6
7
8
Control  
Circuit  
Rated input voltage: 24 V DC ±10 %; ripple 5 %p-p max.  
ON voltage / current: ≥ 15 V DC (input – COM) / ≥ 3.5 mA  
OFF voltage / current: ≤ 5 V DC (input – COM) / ≤ 1 mA  
Input current: ≤ 5.5 mA per point at 24 V DC  
Input resistance: Approx. 4.4 kΩ  
9
11  
12  
13  
14  
15  
16  
17  
18  
10  
ON delay: ≤ 2.0 msec.  
OFF delay: ≤ 2.0 msec.  
TERMINAL ASSIGNMENTS  
10  
NC  
11  
X1  
12  
X3  
13  
X5  
14  
X7  
15  
X9  
16  
XB  
17  
XD  
18  
XF  
1
2
3
4
5
6
7
8
9
COM  
X0  
X2  
X4  
X6  
X8  
XA  
XC  
XE  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
Input Circuit  
1
2
3
4
5
6
7
8
9
COM Common  
X0 Input 0  
X2 Input 2  
X4 Input 4  
X6 Input 6  
X8 Input 8  
XA Input 10  
XC Input 12  
XE Input 14  
10  
11  
12  
13  
14  
15  
16  
17  
18  
NC No Connection  
X1 Input 1  
X3 Input 3  
1
2
COM  
X0  
X5 Input 5  
X7 Input 7  
X9 Input 9  
Control  
Circuit  
XB Input 11  
XD Input 13  
XF Input 15  
18  
XF  
Input Connection Examples  
PNP Connection  
NPN Connection  
+
– +  
1
2
1
2
COM  
X0  
COM  
X0  
18  
18  
XF  
XF  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 40/46  
http://www.m-system.co.jp/  
MODEL: R7C  
NPN TRANSISTOR OUTPUT EXTENSION MODULE, 8 points  
CIRCUIT DIAGRAM  
Output Circuit  
MODEL: R7C-EC8A  
6
2
3
4
5
7
8
9
10  
1
+24V  
Y0  
Y2  
Y4  
Y6  
Y1  
Y3  
Y5  
Y7  
0V  
SPECIFICATIONS  
Common: Negative common (NPN) per 8 points  
Number of I/O: Output, 8 points  
Maximum outputs applicable at once: No limit (at 24 V DC)  
Output status indicator: LED turns ON with contact ON  
Isolation: Output to internal circuits  
Rated load voltage: 24 V DC ±10 %  
Rated output current: 0.25 A per point, 2.0 A per common  
Residual voltage: ≤ 1.2 V  
Control  
Circuit  
Leakage current: ≤ 0.1 mA  
ON delay: ≤ 0.5 msec.  
OFF delay: ≤ 1.5 msec.  
(When driving an inductive load, connect a diode in parallel  
with the load.)  
Output Circuit  
6
2
+24V  
Y0  
TERMINAL ASSIGNMENTS  
6
7
8
9
10  
Y7  
+24 V  
Y1  
Y3  
Y5  
1
2
3
4
5
0 V  
Y0  
Y2  
Y4  
Y6  
Control  
Circuit  
10  
Y7  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
+24 V 24 V DC  
Y1 Output 1  
1
2
3
4
5
0 V 0 V (common)  
Y0 Output 0  
Y2 Output 2  
Y4 Output 4  
Y6 Output 6  
6
7
8
Y3 Output 3  
Y5 Output 5  
Y7 Output 7  
9
10  
1
0V  
Output Connection Example  
6
1
2
+24V  
0V  
+
Y0  
10  
Y7  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 41/46  
http://www.m-system.co.jp/  
MODEL: R7C  
NPN TRANSISTOR OUTPUT EXTENSION MODULE, 16 points  
CIRCUIT DIAGRAM  
Output Circuit  
MODEL: R7C-EC16A  
10  
2
+24V  
Y0  
Y2  
Y4  
Y6  
Y8  
YA  
YC  
YE  
Y1  
Y3  
Y5  
Y7  
Y9  
YB  
YD  
YF  
0V  
SPECIFICATIONS  
Common: Negative common (NPN) per 16 points  
3
4
Number of I/O: Output, 16 points  
5
Maximum outputs applicable at once: No limit (at 24 V DC)  
Output status indicator: LED turns ON with contact ON  
Isolation: Output to internal circuits  
Rated load voltage: 24 V DC ±10 %  
Rated output current: 0.25 A per point, 2.0 A per common  
Residual voltage: ≤ 1.2 V  
6
7
8
Control  
Circuit  
9
Leakage current: ≤ 0.1 mA  
11  
12  
13  
14  
15  
16  
17  
18  
1
ON delay: ≤ 0.5 msec.  
OFF delay: ≤ 1.5 msec.  
(When driving an inductive load, connect a diode in parallel  
with the load.)  
TERMINAL ASSIGNMENTS  
10  
11  
Y1  
12  
Y3  
13  
Y5  
14  
Y7  
15  
Y9  
16  
YB  
17  
YD  
18  
YF  
+24V  
1
2
3
4
5
6
7
8
9
0V  
Y0  
Y2  
Y4  
Y6  
Y8  
YA  
YC  
YE  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
Output Circuit  
1
2
3
4
5
6
7
8
9
0 V 0 V (common)  
Y0 Output 0  
Y2 Output 2  
Y4 Output 4  
Y6 Output 6  
Y8 Output 8  
YA Output 10  
YC Output 12  
YE Output 14  
10 +24 V 24 V DC  
11  
12  
13  
14  
15  
16  
17  
18  
Y1 Output 1  
Y3 Output 3  
Y5 Output 5  
Y7 Output 7  
Y9 Output 9  
YB Output 11  
YD Output 13  
YF Output 15  
10  
+24V  
Y0  
2
Control  
Circuit  
18  
YF  
1
0V  
Output Connection Example  
10  
1
+24V  
0V  
+
2
Y0  
18  
YF  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 42/46  
http://www.m-system.co.jp/  
MODEL: R7C  
PNP TRANSISTOR OUTPUT EXTENSION MODULE, 8 points  
CIRCUIT DIAGRAM  
Output Circuit  
MODEL: R7C-EC8B  
6
2
3
4
5
7
8
9
10  
1
+24V  
Y0  
Y2  
Y4  
Y6  
Y1  
Y3  
Y5  
Y7  
0V  
SPECIFICATIONS  
Common: Positive common (PNP) per 8 points  
Number of I/O: Output, 8 points  
Maximum outputs applicable at once: No limit (at 24 V DC)  
Output status indicator: LED turns ON with contact ON  
Isolation: Output to internal circuits  
Rated load voltage: 24 V DC ±10 %  
Rated output current: 0.25 A per point, 2.0 A per common  
Residual voltage: ≤ 1.2 V  
Control  
Circuit  
Leakage current: ≤ 0.1 mA  
ON delay: ≤ 0.5 msec.  
OFF delay: ≤ 1.5 msec.  
(When driving an inductive load, connect a diode in parallel  
with the load.)  
Output Circuit  
6
2
+24V  
Y0  
TERMINAL ASSIGNMENTS  
6
7
8
9
10  
Y7  
+24 V  
Y1  
Y3  
Y5  
1
2
3
4
5
0 V  
Y0  
Y2  
Y4  
Y6  
Control  
Circuit  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
10  
Y7  
0V  
1
2
3
4
5
0 V 0 V  
6
7
+24 V 24 V DC (common)  
Y1 Output 1  
Y0 Output 0  
Y2 Output 2  
Y4 Output 4  
Y6 Output 6  
8
Y3 Output 3  
9
Y5 Output 5  
10  
Y7 Output 7  
1
Output Connection Example  
+
6
1
2
+24V  
0V  
Y0  
10  
Y7  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 43/46  
http://www.m-system.co.jp/  
MODEL: R7C  
PNP TRANSISTOR OUTPUT EXTENSION MODULE, 16 points  
CIRCUIT DIAGRAM  
Output Circuit  
MODEL: R7C-EC16B  
10  
2
+24V  
Y0  
Y2  
Y4  
Y6  
Y8  
YA  
YC  
YE  
Y1  
Y3  
Y5  
Y7  
Y9  
YB  
YD  
YF  
0V  
SPECIFICATIONS  
Common: Positive common (PNP) per 16 points  
3
4
Number of I/O: Output, 16 points  
Maximum outputs applicable at once: No limit (at 24 V DC)  
Output status indicator: LED turns ON with contact ON  
Isolation: Output to internal circuits  
Rated load voltage: 24 V DC ±10 %  
Rated output current: 0.25 A per point, 2.0 A per common  
Residual voltage: ≤ 1.2 V  
5
6
7
8
Control  
Circuit  
9
Leakage current: ≤ 0.1 mA  
11  
12  
13  
14  
15  
16  
17  
18  
1
ON delay: ≤ 0.5 msec.  
OFF delay: ≤ 1.5 msec.  
(When driving an inductive load, connect a diode in parallel  
with the load.)  
TERMINAL ASSIGNMENTS  
10  
11  
Y1  
12  
Y3  
13  
Y5  
14  
Y7  
15  
Y9  
16  
YB  
17  
YD  
18  
YF  
+24V  
1
2
3
4
5
6
7
8
9
0V  
Y0  
Y2  
Y4  
Y6  
Y8  
YA  
YC  
YE  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
1
2
3
4
5
6
7
8
9
0 V 0 V  
10 +24 V 24 V DC (common)  
Output Circuit  
Y0 Output 0  
Y2 Output 2  
Y4 Output 4  
Y6 Output 6  
Y8 Output 8  
YA Output 10  
YC Output 12  
YE Output 14  
11  
12  
13  
14  
15  
16  
17  
18  
Y1 Output 1  
Y3 Output 3  
Y5 Output 5  
Y7 Output 7  
Y9 Output 9  
YB Output 11  
YD Output 13  
YF Output 15  
10  
+24V  
Y0  
2
18  
1
Control  
Circuit  
YF  
0V  
Output Connection Example  
+
10  
1
+24V  
0V  
2
Y0  
18  
YF  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 44/46  
http://www.m-system.co.jp/  
MODEL: R7C  
RELAY CONTACT OUTPUT EXTENSION MODULE  
CIRCUIT DIAGRAM  
MODEL: R7C-EC8C  
Ry  
11  
12  
13  
14  
2
Y0  
Ry  
Ry  
Ry  
Y1  
SPECIFICATIONS  
Y2  
Common: 1 common per 4 points (4 terminals)  
Common current: Max. 8 A (4 terminals)  
Number of I/O: Relay contact output, 8 points  
Maximum outputs applicable at once: No limit (at 24 V DC)  
Output status indicator: LED turns ON with contact ON  
Isolation: Output to internal circuits  
Y3  
COM0  
COM0  
COM0  
COM0  
Y4  
3
4
Relay driving power: 24 V DC ±10 %, ≥ 60 mA  
Rated load: 250 V AC @2 A (cos ø = 1)  
30 V DC @2 A (resistive load)  
5
Control  
Circuit  
Ry  
Ry  
Ry  
Ry  
15  
16  
17  
18  
6
Y5  
Electrical life 10 cycles (rate 30/min.)  
5
Maximum switching voltage: 250 V AC or 30 V DC  
Maximum switching power: 500 VA or 60 W  
Minimum load: 24 V DC @5 mA  
Y6  
Y7  
COM1  
COM1  
COM1  
COM1  
0V  
Mechanical life: 2 × 10 cycles (rate 300/min.)  
7
When driving an inductive load, external contact protection  
and noise quenching are recommended.  
ON delay: ≤ 10 msec.  
7
8
9
OFF delay: ≤ 10 msec.  
1
10 +24V  
TERMINAL ASSIGNMENTS  
10  
+24 V  
11  
Y0  
12  
Y1  
13  
Y2  
14  
Y3  
15  
Y4  
16  
Y5  
17  
Y6  
18  
Y7  
Output Connection Example  
1
2
3
4
5
6
7
8
9
0 V COM0 COM0 COM0 COM0 COM1 COM1 COM1 COM1  
4 points / common  
8 points / common  
24 V DC  
24 V DC  
+
NO. ID  
FUNCTION  
0 V 0 V  
COM0 Common 0  
NO. ID  
FUNCTION  
+
+
10  
1
10  
1
24V  
0V  
24V  
1
2
3
4
5
6
7
8
9
10 +24 V 24 V DC  
0V  
11  
12  
13  
14  
15  
16  
17  
18  
Y0 Output 0  
Y1 Output 1  
Y2 Output 2  
Y3 Output 3  
Y4 Output 4  
Y5 Output 5  
Y6 Output 6  
Y7 Output 7  
COM0 Common 0  
COM0 Common 0  
COM0 Common 0  
COM1 Common 1  
COM1 Common 1  
COM1 Common 1  
COM1 Common 1  
11  
11  
Y0  
Y0  
Y3 14  
Y3 14  
Y4 15  
Y7 18  
2
5
COM0  
COM0  
+
+
2
5
6
9
COM0  
COM0  
COM1  
COM1  
15  
Y4  
+
+
Y7 18  
6
9
COM1  
COM1  
+
+
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 45/46  
http://www.m-system.co.jp/  
MODEL: R7C  
Specifications are subject to change without notice.  
R7C SPECIFICATIONS  
ES-7801 Rev.26 Page 46/46  
http://www.m-system.co.jp/  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY