R8-PC4A [MSYSTEM]

Remote I/O R8 Series PULSE OUTPUT MODULE;
R8-PC4A
型号: R8-PC4A
厂家: M-SYSTEM    M-SYSTEM
描述:

Remote I/O R8 Series PULSE OUTPUT MODULE

输出元件
文件: 总5页 (文件大小:216K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: R8-PC4A  
Remote I/O R8 Series  
GENERAL SPECIFICATIONS  
Connection  
Output: 4-pin e-CON connector  
PULSE OUTPUT MODULE  
(NPN transistor output, 4 points, voltage contact)  
• 4-channel transistor output, compact size remote I/O  
module  
Unit side connector XN2D-1474-S002 (Omron)  
Recommended cable side connector XN2A-1470 (Omron)  
Applicable wire size 0.08 - 0.5 mm (AWG28 - 20)  
2
Outer sheath diameter: max. 1.5 dia  
(The cable connector is not included in the package.  
Refer to the specifications of the product.)  
Excitation supply, internal bus:  
• Configurable with PC configurator (model: R8CFG)  
12 (.47)  
Connected to internal bus connector  
Internal power: Supplied from internal bus connector  
Isolation: Output or exc. supply to internal bus or internal  
power  
115 (4.53)  
ON/OFF pulse width: Set with the side DIP switch  
Module address: With rotary switch  
Terminating resistor: Built-in (DIP Switch, default: disable)  
Configuration mode: With DIP switches on the side panel  
Status indicator: Bi-color (red/green) LED; Refer to the  
instruction manual.  
59 (2.32)  
mm (inch)  
Output status indicators: Green LED; Refer to the instruction  
manual.  
MODEL: R8–PC4A[1]  
ORDERING INFORMATION  
• Code number: R8-PC4A[1]  
Specify a code from below for [1].  
(e.g. R8-PC4A/A/Q)  
OUTPUT SPECIFICATIONS  
Output: NPN transistor 4 points  
Maximum frequency: Approx. 80 Hz (DIP SW selectable)  
Max. ouptut pulse number per setting: 2000  
(The number of pulse output by one writing is up to 2000.  
No output when the setting, in which difference between  
the present value is not less than 2001 pulses, is set.)  
Totalized pulse range: 1 – 10000 (Max. pulse range  
selectable from 1 to 65535 using the PC Configurator  
Software (model: R8CFG). ‘0’ at reset)  
Count at overflow: Reset and restart at ‘1.’  
Isolation: Photo coupler  
• Specify the specification for option code /Q  
(e.g. /C01)  
[1] OPTIONS (multiple selections)  
0V Output for Excitation Supply  
/A: With (must be specified.)  
blank: none  
/Q: With options (specify the specification)  
Rated load voltage: 24 V DC ±10 % (from exc. supply)  
24 V DC (from external power supply*)  
Rated output current: 0.2 A per point (from exc. supply)  
0.2 A per point (from external power  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
supply*)  
/C02: Polyurethane coating  
*A power supply different from exc. supply is required.  
Exc. supply must be used even when using external power  
supply.  
RELATED PRODUCTS  
• PC configurator software (model: R8CFG)  
Downloadable at M-System’s web site.  
A dedicated cable is required to connect the module to the  
PC. Please refer to the internet software download site or  
the users manual for the PC configurator for applicable  
cable types.  
Residual voltage: ≤ 0.5 V  
Leakage current: ≤ 0.1 mA  
Shortcircuit protection: Included  
Overheat Protection Function: Included  
INSTALLATION  
Max. current consumption: 100 mA  
Operating temperature: -10 to +55°C (14 to 131°F)  
R8-PC4A SPECIFICATIONS  
ES-9795 Rev.4 Page 1/5  
http://www.m-system.co.jp/  
MODEL: R8-PC4A  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: DIN rail  
Weight: 60 g (2.12 oz)  
PERFORMANCE  
Data allocation: 2  
Module addresses in use: 2  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500V AC @1 minute  
(output or exc. supply to internal bus or internal power to  
ground)  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
RoHS Directive  
EN 50581  
OPERATING MODES  
When writing the number of output pulse (target value)  
from a host, R8-PC4A outputs the difference from the  
number of pulse outputs until now (present value) as the  
remainder number of pulse.  
The present value of the R8-PC4A is held even with power  
off. If target value is ‘0’ or higher than totalized pulse upper  
limit, it is invalid. When the target value is not less than  
2001 for the present value, the unit does not output the  
pulse and the present value is equal to the target value.  
E.g.1 Present value = 1000 and target value = 1500, it  
outputs 500 pulses.  
E.g.2 Present value = 9000 and target value = 500, it  
outputs 1500 pulses.  
E.g.3 Present value = 1000 and target value = 3001, it  
does not outputs any pulse, present value = 3001.  
(When the totalized pulse upper limit is initial setting,  
10000.)  
R8-PC4A SPECIFICATIONS  
ES-9795 Rev.4 Page 2/5  
http://www.m-system.co.jp/  
MODEL: R8-PC4A  
EXTERNAL VIEW  
FRONT VIEW  
SIDE VIEW  
Module Address Setting  
Rotary SW  
Status Indicator LED  
0
0
SW1  
SW2  
5
5
RUN  
Output Status Indicator LED  
0
0
x10  
CARD ADD. x1  
5
5
Function Setting  
DIP SW  
Internal Bus Connector  
On  
PO1  
PO2  
PO3  
PO4  
SW4  
1 2 3 4 5 6 7 8  
Output Connectors  
On  
Term  
SW3  
Terminator DIP SW  
OPERATING MODE SETTING  
(*) Factory setting  
Module Address  
ON/OFF Pulse Width: (SW4-2, 3, 4, 5, 6, 7)  
Setting for all outputs.  
The left switch determines the tenth place digit, while the  
right one does the ones place digit of the module address.  
Address is selected between 0 to 30.  
(Factory setting: 0)  
Setting for each output can be done with a PC.  
ON  
3
OFF  
6
PULSE WIDTH  
TIME *1  
2
4
5
7
OFF OFF OFF OFF OFF OFF  
ON OFF OFF ON OFF OFF  
OFF ON OFF OFF ON OFF  
5 msec.(*)  
10 msec.  
15 msec.  
100 msec.  
500 msec.  
1 sec.  
0
0
5
5
ON  
ON OFF ON  
ON OFF  
Module Address Setting (x1)  
Module Address Setting (x10)  
OFF OFF ON OFF OFF ON  
ON OFF ON  
OFF ON  
ON ON  
ON OFF ON  
ON  
ON OFF ON  
1.5 sec.  
Counter Reset (SW4-1)  
ON  
ON  
ON  
ON  
2 sec.  
1) Turn the power off.  
*1. Minimum ensured time duration. For example, with 5 msec.  
setting, the minimum pulse width is 5 msec. (Max. value =  
Setting time + 2 msec.)  
2) Turn ON the Counter Reset SW (SW4-1).  
3) Return the module to the base and turn the power supply ON.  
The status indicator LED turns ON in amber.  
4) Wait at least 5 seconds. Turn the power supply OFF.  
5) Turn OFF the Counter Reset SW (SW4-1).  
Configuration Mode  
SW4  
CONFIGURATION MODE  
8
6) Return the module to the base and turn the power supply ON.  
Note: Counter Reset SW must be turned OFF after this procedure  
because the module does not start counting with ON state.  
DIP switch setting (*)  
OFF  
ON  
PC Configurator and communication  
Terminator DIP SW  
TERMINATOR SW  
Without (*)  
With  
SW3  
OFF  
ON  
R8-PC4A SPECIFICATIONS  
ES-9795 Rev.4 Page 3/5  
http://www.m-system.co.jp/  
MODEL: R8-PC4A  
EXTERNAL DIMENSIONS unit: mm (inch)  
12 (.47) [3 (.12)]  
59 (2.32)  
55 (2.17)  
[4 (.16)]  
DIN RAIL  
(35 mm wide)  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
STATUS  
OUTPUT  
LED STATUS LED  
OUTPUT  
CONNECTOR 1  
+24V  
INTERNAL  
BUS  
Comm.  
Circuit  
1
2
3
4
24V  
Control  
Circuit  
NC  
OUTPUT 1  
INTERNAL  
POWER  
0V  
ROTARY SW  
DIP SW  
Po1  
+24V  
0V  
EXC.  
SUPPLY  
0V  
Output  
Circuit  
OUTPUT  
CONNECTOR 4  
1
2
3
4
24V  
NC  
OUTPUT 4  
0V  
Po4  
0V  
Note: Pin 1 of output connector is connected to 24V of the excitation supply.  
Pin 3 of output connector is connected to 0V of the excitation supply.  
Output Connection Examples  
Open Collector  
Wet Contact  
+24V  
+24V  
1
1
24V  
NC  
0V  
24V  
NC  
0V  
2
3
4
2
3
Po  
+
4
Pon  
Pon  
0V  
0V  
R8-PC4A SPECIFICATIONS  
ES-9795 Rev.4 Page 4/5  
http://www.m-system.co.jp/  
MODEL: R8-PC4A  
Specifications are subject to change without notice.  
R8-PC4A SPECIFICATIONS  
ES-9795 Rev.4 Page 5/5  
http://www.m-system.co.jp/  

相关型号:

R8-PC4A/A

Remote I/O R8 Series PULSE OUTPUT MODULE
MSYSTEM

R8-PC4A/Q

Remote I/O R8 Series PULSE OUTPUT MODULE
MSYSTEM

R8-PS1

Remote I/O R8 Series EXTENSION POWER SUPPLY MODULE
MSYSTEM

R8-PS1-R

Remote I/O R8 Series EXTENSION POWER SUPPLY MODULE
MSYSTEM

R8-PS1-R/Q

Remote I/O R8 Series EXTENSION POWER SUPPLY MODULE
MSYSTEM

R8-TC2

Remote I/O R8 Series TEMPERATURE CONTROL MODULE
MSYSTEM

R8-TC2A

Remote I/O R8 Series TEMPERATURE CONTROL MODULE
MSYSTEM

R8-TC2A/Q

Remote I/O R8 Series TEMPERATURE CONTROL MODULE
MSYSTEM

R8-TC2P

Remote I/O R8 Series TEMPERATURE CONTROL MODULE
MSYSTEM

R8-TC2P/Q

Remote I/O R8 Series TEMPERATURE CONTROL MODULE
MSYSTEM

R8-TC2V

Remote I/O R8 Series TEMPERATURE CONTROL MODULE
MSYSTEM

R8-TC2V/Q

Remote I/O R8 Series TEMPERATURE CONTROL MODULE
MSYSTEM