CPCI200A-1C [MURATA]

AC-DC Regulated Power Supply Module, 4 Output, 200W, Hybrid, PACKAGE-47;
CPCI200A-1C
型号: CPCI200A-1C
厂家: muRata    muRata
描述:

AC-DC Regulated Power Supply Module, 4 Output, 200W, Hybrid, PACKAGE-47

输出元件
文件: 总4页 (文件大小:120K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
cPCI200A-1C Series  
200W 3Ux4HP AC/DC CompactPCI™  
NOT RECOMMENDED  
-12V  
For full details go to  
www.murata-ps.com/rohs  
FOR NEW DESIGNS  
1A  
Yes  
Yes  
INPUT CHARACTERISTICS  
Parameter  
Conditions  
Min  
90  
Typ  
Max Units  
Input Operating Voltage  
Input Frequency  
Input Current  
264  
63  
Vac  
Hz  
47  
3.5  
0.99  
35  
Arms  
Power Factor  
0.95  
0.98  
1
FEATURES  
Inrush Current  
240Vac  
Apk  
3Ux4HP package  
Leakage Current  
240VAC, 63Hz  
mA  
200W power at 0-50ºC  
OUTPUT CHARACTERISTICS  
PICMG 2.11 Compliant  
Output Current  
Widerange 90-264VAC Input  
Active power factor correction to EN61000-3-2  
Class A conducted EMI performance  
47-pin I/O Connector  
Output  
Nominal Voltage  
Total Regulation1  
Min  
1A3  
1 A3  
0A  
Max  
25A  
30A  
5A  
V12  
V22  
+5.0Vdc  
+3.3Vdc  
+12Vdc  
-12Vdc  
+4/-2%  
+4/-2%  
4%  
V3  
V4  
0A  
1A  
4%  
80% efficiency  
Parameter  
Temperature Coefficient  
PARD (V1 & V2)  
PARD (V3 & V4)  
Output Power  
Output Power  
Conditions  
Min  
Typ  
Max  
0.02  
Units  
%/ºC  
mVp-p  
mVp-p  
W
Full power with just 250lfm airflow  
Hot-swap capable  
20MHz bandwidth  
20MHz bandwidth  
50  
120  
180  
200  
100  
5
DESCRIPTION  
50ºC, 250lfm airflow  
70ºC, 250lfm airflow  
ΔV, 50% load step  
Settling time  
0
0
The cPCI200A-1C is a high-reliability, 200W, 3Ux4HP  
CompactPCI™ power supply developed for chassis’  
with airflows as low as 250lfm. The use of resonant  
conversion and ORing FETs yields high efficiency which  
consequently permits packaging of this product in a  
compact, single card slot format (4HP).  
W
%Vnom  
μsec  
%Vnom  
A
Transient Response  
500  
135  
Over-Voltage Protection  
Minimum Load4  
V1, V2, & V3  
125  
The ORing FETs, current sharing, and synchronous start  
control allow the cPCI200A-1C to be operated in N+n  
parallel-redundant configurations. The low leakage  
current permits redundant configurations to comply  
with safety standards. The unit is capable of hot-swap  
performance to support high-availability enterprise  
applications.  
V1 or V2  
1
Output Holdup Time  
Remote Sense Compensation5  
Full load, low line  
V1, V2, & V3  
12  
16  
10  
msec  
mV  
250  
Current Share Tolerance  
V1-V3; Io>25%  
Pri-Sec  
%
3
kVac  
kVac  
Vac  
With  
a widerange input of 90-264VAC, safety  
Isolation  
Pri-Chassis  
1.5  
500  
agency approvals to UL60950 and EN60950, EMI  
compliance to Class A FCC and EN55022 standards,  
the cPCI200A-1C was designed with globally-deployed  
systems in mind. Additional features include remote  
sense compensation, unit enable control (EN#), output  
inhibit control (INH#), output fault signal (FAL#), and  
thermal warning signal (DEG#). LEDs are provided for  
visual indication of input power presence and output  
fault condition.  
Sec-Chassis  
Notes:  
1. Total regulation includes line, load, and cross regulation.  
2. Maximum combined power from V1 & V2 not to exceed 125W.  
3. Minimum load requirement of 1A may be fulfilled on either V1 or V2, but need not be applied to both.  
The unit will operate with less than the stated minimum, but full load on V3 & V4 is only achievable with  
the minimum load requirement met on V1 and/or V2.  
4. Minimum load is for a single unit; units operated in parallel may require additional load to achieve full  
power on outputs V3 and V4.  
5. Unit automatically reverts to local sensing if the sense lines are opened. Unit is protected against shorted  
or reversed sense lines.  
www.murata-ps.com  
cPCI200A-1C Series Rev D 02/2008 Page 1 of 4  
cPCI200A-1C Series  
200W 3Ux4HP AC/DC CompactPCI™  
GENERAL CHARACTERISTICS  
Parameter  
Efficiency  
Conditions  
Min  
Typ  
79  
Max Units  
Full load, 240Vac  
81  
%
kHz  
kHz  
khrs  
g
PFC Converter  
100  
130  
Switching Frequency  
Main Converter  
MTBF  
Calculated per Telcordia SR-332, Issue 1, 50ºC, 250lfm, ground benign  
Unpackaged  
200  
Weight  
620  
PROTECTION  
Inception  
Units  
Parameter  
Conditions/Response  
Automatic recovery upon restoration to operational temperatures  
Min  
Typ  
100  
3
Max  
Thermal Shutdown  
Input Current Limit  
Input Protection  
ºC  
Arms  
Internal line fuse; Schurter 0034.6981 or equivalent  
V1, V2, & V3  
4
Arms  
Over-voltage Protection  
Parameter  
125  
135  
%Vnom  
Conditions/Response  
Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the fault condition.  
Overload response for outputs V1-V3 is constant-current mode. Overload response for V4 is foldback; hiccup mode in response to a hard short.  
Output Overload Protection  
Design Verification Testing (DVT) confirms that voltage excursions on the output buses resulting from insertion/extraction events do not exceed  
the specified maximum of 5%. However, routing of power and signal lines in the mating backplane is critical to minimization of such excursions.  
In addition, performance can be critically affected by load characteristics including resistance, negative resistance, and reactive components.  
While the control loop responses have been designed for optimum hot-swap performance over a wide range of load characteristics, there may be in-  
stances where the voltage excursions exceed published specifications. In such cases, the control loop responses can be modified to perform optimally.  
Hot-Swap Capability  
Output Fault Isolation  
Output isolation devises are present in all outputs to isolate faults within a failed power supply.  
STATUS & CONTROL SIGNALS & INDICATORS  
Name  
Description  
Short pin on connector will enable the outputs when the mating pin is grounded. Supply will not power up until this pin is engaged  
to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector.  
Enable (EN#)  
Output Inhibit (INH#)  
Output Fault (FAL#)  
Secondary referenced; active low, TTL compatible. Logic “0” or short circuit to output return inhibits all outputs.  
Secondary referenced; TTL compatible. Logic “0” denotes that one of the output voltages has fallen below the lower regulation limit.  
Connection of the sense leads across the load at the desired point of regulation will compensate for voltage distribution drops up to 250mV  
between the output terminals of the power supply and the point of connection. The output is protected against shorted or open leads. Each  
of the Remote Sense lines must be terminated to the corresponding output and return lines in order guarantee all performance specifications.  
Remote Sense (RS+, RS-)  
Thermal Warning (DEG#)  
Sync Start (Sync)  
Secondary referenced; TTL compatible. Logic “0” denotes a thermal warning; nominally, 10ºC prior to thermal shutdown.  
Interconnection of the sync start leads between cPCI200A-1 units connected in parallel permits synchronous starting to support loads  
that exceed the maximum for a single unit. Pin 35 (V1 Share) is used for the synchronous start function.  
An LED will illuminate red if the output voltages are not within specification, coincident with assertion of the FAL# signal. This LED  
will also illuminate amber if the output is inhibited.  
Fault Indicator LED  
Power Present Indicator LED  
A green LED will be illuminated when the input voltage is present and above the minimum requirement.  
ENVIRONMENTAL CHARACTERISTICS  
Parameter  
Conditions  
Min  
0
Typ  
Max  
50  
Units  
ºC  
ºC  
%
Ambient Operating Temperature  
Ambient Storage Temperature  
Operating Humidity  
-40  
10  
125  
Non-condensing  
90  
Storage Humidity  
Non-condensing  
5
90  
%
Operating. De-rate operating ambient temperature by 2Cº per 1000ft above 5000ft.  
Storage  
-200  
-200  
10000  
50000  
ft  
Altitude  
ft  
www.murata-ps.com  
cPCI200A-1C Series Rev D 02/2008 Page 2 of 4  
cPCI200A-1C Series  
200W 3Ux4HP AC/DC CompactPCI™  
ELECTROMAGNETIC COMPATIBILITY (EMC)  
Characteristic  
Compliance  
Input Current Harmonics  
EN61000-3-2, Class A  
CFR Title 47, Part 15, Sub-part B, Class A  
EN55022, Class A  
Conducted Emissions  
Electrostatic Discharge (ESD)  
Radiated Immunity  
EN61000-4-2, Level 3, Criterion B  
EN61000-4-3, Level 3  
Conducted Immunity  
Line Voltage Surge  
EN61000-4-4, Level 3, Criterion A  
EN61000-4-5, Level 2, Criterion B  
EN61000-4-11  
Line Voltage Interruptions  
CERTIFICATIONS  
Agency/Characteristic  
Standard  
UL  
UL60950-1  
CSA  
CSA60950-1 (per cUL)  
EN60950-1  
VDE  
CE  
LVD Directive; self-certified  
RoHS  
SELV  
Vibration  
Shock  
EN Directive 2002/95/EC; self-certified (see Selection Guide for specific model compliances)  
Certified  
MIL-STD-883F, Method 2007.3, Test Condition A, pending  
MIL-STD-883F, Method 2002.4, Test Condition A, pending  
SAFETY AGENCY RATINGS  
Input Voltage  
Input Current  
Input Power  
120/240Vac  
3A  
270W  
MECHANICAL DIMENSIONS  
www.murata-ps.com  
cPCI200A-1C Series Rev D 02/2008 Page 3 of 4  
cPCI200A-1C Series  
200W 3Ux4HP AC/DC CompactPCI™  
CONNECTOR  
RoHS COMPLIANT INFORMATION  
Pin1  
Staging2  
Signal Name Description  
This series is compatible with RoHS soldering  
systems with a peak wave solder temperature  
of 300ºC for 10 seconds. The pin termination  
finish on this product series is Tin Plate, Hot  
Dipped over Matte Tin with Nickel Preplate.  
The series is backward compatible with Sn/Pb  
soldering systems.  
1-4  
5-12  
13-18  
19  
20  
21  
22  
23  
24  
25  
M
M
M
M
M
M
M
M
M
M
M
S
V1  
RTN  
V2  
V1 Output  
V1 and V2 Return  
V2 Output  
RTN  
V3  
V3 Return  
V3 Output  
V4  
RTN  
V4 Output  
Signal Return  
For further information, please visit www.murata-ps.com/rohs  
RESERVED  
RTN  
GA0  
RESERVED  
EN#  
Reserved  
V4 Return  
Geographic Address Bit 0  
Reserved  
Enable  
26  
27  
28  
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
L
GA1  
Geographic Address Bit 1  
V1 Adjust  
V1 Remote Sense  
Geographic Address Bit 2  
V2 Adjust  
V2 Remote Sense  
Sense Return  
Sync Start  
V3 Remote Sense  
IPMB Serial Clock Line  
Degrade Signal  
Inhibit  
IPMB Serial Data Line  
V2 Current Share  
Fail Signal  
IPMB Power Input  
V3 Current Share  
Chassis Grnd (Safety Grnd)  
AC Input Neutral/+DC Input  
AC Input Line/-DC Input  
293  
30  
V1ADJ  
V1 SENSE  
GA2  
V2ADJ  
V2 SENSE  
S RTN  
V1 SHARE  
V3 SENSE  
IPMB SCL  
DEG#  
31  
323  
33  
34  
35  
36  
373  
38  
39  
INH#  
403  
413  
42  
IPMB SDA  
V2 SHARE  
FAL#  
IPMB PWR  
V3 SHARE  
CGND  
433  
443  
45  
46  
47  
M
M
ACN/+DC IN  
ACL/-DC IN  
Notes:  
1. Pin numbers correspond to the female backpane connector.  
2. “L denotes long pin length (first mate, last break)  
“M” denotes medium pin length  
“S” denotes short pin length (last mate, first break)  
3. This function not used in the CPCI200A-1C Series.  
ISO9001  
CERTIFIED  
USA:  
Tucson (Az), Tel: (800) 547 2537, email: sales@murata-ps.com  
Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com  
UK:  
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com  
Murata Power Solutions, Inc.  
France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com  
Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED  
Japan: Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com  
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com  
Website: www.murata-ps.jp  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
China:  
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com  
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com  
notice.  
© 2008 Murata Power Solutions, Inc.  
www.murata-ps.com  
cPCI200A-1C Series Rev D 02/2008 Page 4 of 4  

相关型号:

CPCI200D-1

180/225 wATT, 3U x 4HP CompactPCI
CANDD

CPCI200D-1

200W 3Ux4HP DC/DC CompactPCI Power Supply
MURATA

CPCI200D-1C

200W 3Ux4HP DC/DC CompactPCI Power Supply
MURATA

CPCI200D-2

180/225 wATT, 3U x 4HP CompactPCI
CANDD

CPCI200D-2

200W 3Ux4HP DC/DC CompactPCI Power Supply
MURATA

CPCI200D-2C

200W 3Ux4HP DC/DC CompactPCI Power Supply
MURATA

CPCI200D-3

180/225 wATT, 3U x 4HP CompactPCI
CANDD

CPCI200D-3

200W 3Ux4HP DC/DC CompactPCI Power Supply
MURATA

CPCI200D-3C

200W 3Ux4HP DC/DC CompactPCI Power Supply
MURATA

CPCI200D-4

180/225 wATT, 3U x 4HP CompactPCI
CANDD

CPCI200D-4

200W 3Ux4HP DC/DC CompactPCI Power Supply
MURATA

CPCI200D-4C

200W 3Ux4HP DC/DC CompactPCI Power Supply
MURATA