NTA Series  
Isolated 1W Dual Output SM DC/DC Converters  
SELECTION GUIDE  
Nominal  
Input  
Voltage  
Input  
Current at  
Rated Load  
Output  
Voltage  
Output  
Current  
Isolation  
Capacitance  
Efficiency  
MTTF2  
Order Code1  
V
3.3  
3.3  
3.3  
3.3  
3.3  
5
V
3.3  
5
mA  
152  
100  
55  
mA  
402  
388  
405  
390  
392  
259  
290  
251  
267  
260  
256  
121  
113  
111  
110  
%
75  
78  
75  
77  
77  
77  
69  
80  
75  
77  
78  
69  
74  
75  
76  
pF  
29  
30  
34  
40  
42  
31  
33  
42  
38  
44  
43  
50  
72  
89  
100  
kHrs  
1005  
399  
827  
375  
206  
964  
1697  
367  
682  
343  
188  
559  
375  
243  
154  
NTA0303MC  
NTA0305MC  
NTA0309MC  
NTA0312MC  
NTA0315MC  
NTA0503MC  
NTA0505MC  
NTA0505MEC  
NTA0509MC  
NTA0512MC  
NTA0515MC  
NTA1205MC  
NTA1209MC  
NTA1212MC  
NTA1215MC  
9
12  
15  
3.3  
5
42  
33  
152  
100  
100  
55  
FEATURES  
RoHS compliant  
5
5
5
5
9
Efficiency up to 78%  
5
12  
15  
5
42  
Wide temperature performance at full  
1 Watt load, –40°C to 85°C  
5
33  
12  
12  
12  
12  
100  
55  
9
UL 94V-0 Package material  
Footprint over pins 1.64cm2  
Lead frame technology  
3.3V, 5V & 12V Input  
12  
15  
42  
33  
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external  
capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the  
additional external capacitance for reliable start up.  
3.3V, 5V, 9V, 12V & 15V Output  
Internal SMD construction  
Toroidal magnetics  
INPUT CHARACTERISTICS  
Parameter  
Conditions  
Min.  
2.97  
4.5  
Typ.  
3.3  
5
Max.  
3.63  
5.5  
Units  
V
Continuous operation, 3V input types  
Continuous operation, 5V input types  
Continuous operation, 12V input types  
Voltage range  
1kVDC Isolation  
10.8  
12  
41  
13.2  
50  
Reflected ripple current  
mA p-p  
MTTF up to 2.1 Million hours  
Power density 1.36W/cm3  
No heatsink required  
ISOLATION CHARACTERISTICS  
Parameter  
Conditions  
Min.  
1000  
10  
Typ.  
Max.  
Max.  
Units  
VDC  
GΩ  
Isolation voltage  
Resistance  
Flash tested for 1 second  
Viso= 1000VDC  
Custom solutions available  
Multi-layer ceramic capacitors  
GENERAL CHARACTERISTICS  
Parameter  
Conditions  
Min.  
Typ.  
100  
110  
115  
Units  
kHz  
PRODUCT OVERVIEW  
The NTA series of miniature surface mounted  
DC/DC Converters employ leadframe  
technology and transfer moulding techniques  
to bring all of the benefits of IC style  
packaging to hybrid circuitry. Co-planarity of the  
lead positions is based upon IEC 191-6:1990. The  
devices are suitable for all applications where  
high volume production is envisaged.  
0312MC, 0315MC  
Switching frequency  
0303MC, 0305MC, 0503MC, 0505MEC  
All other variants  
ABSOLUTE MAXIMUM RATINGS  
Short-circuit protection3  
1 second  
300°C  
700mW  
5.5V  
Lead temperature 1.5mm from case for 10 seconds  
Internal power dissipation  
Input voltage VIN, NTA03 types  
Input voltage VIN, NTA05 types  
Input voltage VIN, NTA12 types  
7V  
15V  
1. If components are required in tape and reel format suffix order code code with -R, e.g. NTA0505MC-R.  
2. Calculated using MIL-HDBK-217F with nominal input voltage at full load.  
3. Supply voltage must be disconnected at the end of the short circuit duration.  
All specifications typical at T =25°C, nominal input voltage and rated output current unless otherwise specified.  
A
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com  
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232  
KDC_NTA.G04 Page 1 of 4  
NTA Series  
Isolated 1W Dual Output SM DC/DC Converters  
OUTPUT CHARACTERISTICS  
Parameter  
Rated Power  
Conditions  
TA=-40°C to 85°C  
Min.  
Typ.  
Max.  
1.0  
Units  
W
Voltage Set Point Accuracy  
Line regulation  
See tolerance envelope  
High VIN to low VIN  
1.0  
10  
10  
9.0  
6.5  
11  
6.0  
6.0  
40  
50  
35  
50  
65  
1.2  
15  
%/%  
%
10% load to rated load, 0303MC & 0503MC  
10% load to rated load, 5V output types  
10% load to rated load, 0309MC  
12  
10  
Load Regulation1  
Ripple and Noise  
10% load to rated load, 0509MC & 1209MC  
10% load to rated load, 0312MC & 0315MC  
10% load to rated load, 0512MC & 1212MC  
10% load to rated load, 0515MC & 1215MC  
BW=DC to 20MHz, 3.3V output types, NTA0305MC & NTA0505MEC  
BW=DC to 20MHz, all other 5V output types  
BW=DC to 20MHz, 9V output types  
BW=DC to 20MHz, 12V output types  
BW=DC to 20MHz, 15V output types  
8.0  
14  
8.5  
7.0  
80  
100  
80  
mV p-p  
110  
110  
TEMPERATURE CHARACTERISTICS  
Parameter  
Specification  
Storage  
Conditions  
All output types  
Min.  
-40  
Typ.  
Max.  
85  
Units  
°C  
-55  
125  
0305MC, 0505MEC, 0312MC, 0315MC  
0303MC, 0309MC, 0503MC  
0505MC, 1205MC  
19  
25  
46  
35  
Case temperature rise above  
ambient  
All other variants  
Cooling  
Free air convection  
TECHNICAL NOTES  
ISOLATION VOLTAGE  
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,  
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.  
Murata Power Solutions NTA series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.  
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”  
For a part holding no specific agency approvals, such as the NTA series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or  
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part  
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must  
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to  
safety standard requirements.  
REPEATED HIGH-VOLTAGE ISOLATION TESTING  
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,  
construction and environment. The NTA series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While  
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically  
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We  
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.  
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further  
insulation system of physical spacing or barriers.  
TEMPERATURE DERATING GRAPH  
RoHS COMPLIANCE INFORMATION  
1.5  
This series is compatible with RoHS soldering systems with  
a peak reflow solder temperature of 245ºC and time above  
liquidus of 217ºC for 80 seconds. The pin termination finish  
on this product series is Gold, plating thickness 0.1 microns  
minimum. The series is backward compatible with Sn/Pb  
soldering systems.  
85°C  
1.0  
0.5 Safe Operating Area  
For further information, please visit www.murata-ps.com/rohs  
0
-40  
100  
150  
0
50  
Ambient Temperature (°C)  
1. 12V input types have typically 3% less load regulation change.  
www.murata-ps.com  
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232  
KDC_NTA.G04 Page 2 of 4  
NTA Series  
Isolated 1W Dual Output SM DC/DC Converters  
TOLERANCE ENVELOPES  
Tolerance Envelope - 3.3V output types.  
+9%  
All other types.  
+10%  
+5%  
VNOM  
+2.5%  
-2.5%  
-7.5%  
+1%  
VNOM  
+1%  
-7%  
-7%  
-15%  
100  
75  
Output Load Current (%)  
100  
10 25  
50  
75  
10 25  
50  
Output Load Current (%)  
PACKAGE SPECIFICATIONS  
MECHANICAL DIMENSIONS  
PIN CONNECTIONS  
0.600 (15.24)  
0.400 (10.16)  
Pin  
1
Function  
-VIN  
+VIN  
NA  
18  
16  
10  
14  
12  
3
0.441  
5
0.020(0.5)  
REFERENCE  
PLANE  
0.409 0.303  
(11.20)  
(7.70)  
7
OV  
NTA0505MC  
XYYWW  
(10.40)  
P
9
-VOUT  
NA  
0.059(1.50)  
0.047(1.20)  
10 PINS  
5
1
3
7
9
10  
12  
14  
16  
18  
°
5.00  
+VOUT  
NA  
0.026(0.65)  
0.022(0.55)  
S
0.008(0.2)  
0.100(2.54)  
NA  
0.083  
(2.10)  
NA  
DETAIL A  
0.250 (6.35)  
0.260 (6.6)  
0.234 (5.95) 0.230 (5.85)  
SEATING PLANE  
S
0.010 (0.25)  
0.004 (0.10)  
NA - Not available for electrical connection.  
10 PINS  
0.004 (0.1)  
0.074  
(1.875) MAX  
0.012 (0.30)  
0.008 (0.20)  
0.11 (2.79) MAX  
S
All dimensions in inches 0.01 (mm 0.25mm). All pins on a 0.1 (2.54) pitch.  
Weight: 1.53g  
RECOMMENDED FOOTPRINT DETAILS  
TUBE OUTLINE DIMENSIONS  
ꢌꢀꢁꢀꢄꢉœꢀꢁꢀꢀꢋꢌꢅꢀꢁꢋꢀœꢀꢁꢊꢍꢈ  
ꢀꢁꢀꢃꢂꢌꢅꢄꢁꢊꢀꢈ  
ꢀꢁꢉ  
ꢅꢊꢀꢁꢊꢋꢈ  
ꢀꢁꢀꢇꢆ  
ꢅꢄꢁꢀꢀꢈ  
ꢀꢁꢍꢋꢍꢌꢅꢊꢉꢁꢂꢍꢈ  
ꢀꢁꢂꢇꢀꢌꢅꢆꢁꢉꢀꢈ  
ꢀꢁꢂꢃꢄ  
ꢅꢆꢁꢇꢀꢈ  
ꢀꢁꢄꢋꢉꢌꢅꢋꢁꢇꢀꢈ  
ꢀꢁꢊꢅꢄꢁꢍꢉꢈ  
ꢀꢁꢀꢉꢌꢅꢊꢁꢀꢀꢈꢌ.*/  
Unless otherwise stated all dimensions in inches 0.02 (mm 0.5).  
Tube length : 18.70 0.07 (475 2.0).  
Tube Quantity : 25  
www.murata-ps.com  
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232  
KDC_NTA.G04 Page 3 of 4  
NTA Series  
Isolated 1W Dual Output SM DC/DC Converters  
TAPE & REEL SPECIFICATIONS  
REEL OUTLINE DIMENSIONS  
TAPE OUTLINE DIMENSIONS  
ꢊꢄꢁꢆꢆ  
ꢅꢂꢂꢀꢈꢌ."9  
ꢀꢁꢋꢄ  
ꢅꢊꢍꢁꢇꢍꢈ  
ꢀꢁꢀꢄꢌꢅꢀꢁꢋꢀꢈꢌ."9  
ꢂꢁꢆꢉ  
ꢅꢊꢀꢀꢈꢌ.*/  

ꢏꢀꢁꢀꢀꢉꢌꢅꢏꢀꢁꢊꢀꢈ  
ꢎꢀꢁꢀꢀꢌꢅꢎꢀꢁꢀꢀꢈ  
ꢀꢁꢀꢋꢌꢅꢊꢁꢍꢀꢈ  
ꢀꢁꢋꢂꢌꢅꢊꢋꢁꢀꢀꢈ  
ꢀꢁꢍꢊœꢀꢁꢀꢀꢆ  
ꢅꢊꢂꢁꢀꢀœꢀꢁꢄꢍꢈ  

ꢀꢁꢀꢃꢌ  
ꢅꢄꢁꢀꢀꢈ  
ꢀꢁꢉꢋꢌ  
ꢅꢊꢊꢁꢋꢀꢈ  
ꢀꢁꢊꢋꢌ  
ꢅꢉꢁꢀꢀꢈ  
ꢀꢁꢄꢋ  
ꢅꢋꢁꢋꢀꢈ  
ꢀꢁꢀꢇꢅꢊꢁꢇꢍꢈ  
ꢀꢁꢉꢍꢌ  
ꢅꢊꢊꢁꢍꢀꢈ  
ꢀꢁꢆꢉœꢀꢁꢀꢉ  
ꢅꢄꢉꢁꢀꢀœꢀꢁꢂꢀꢈ  
REEL PACKAGING DETAILS  
CARRIER TAPE START  
3.94 (100) MIN  
TRAILER SECTION  
6.30 (160) MIN  
GOODS ENCLOSURE  
SECTION  
Product Orientation  
Pin 1, located nearest to  
carrier drive sprocket.  
LEADER SECTION  
15.75 (400) MIN  
Reel Quantity : 500  
USA:  
Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com  
UK: Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com  
Tucson (Az), Tel: (800) 547 2537, email: sales@murata-ps.com  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com  
Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com  
Japan: Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com  
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com  
Website: www.murata-ps.jp  
www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
China:  
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com  
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com  
notice.  
© 2008 Murata Power Solutions, Inc.  
www.murata-ps.com  
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232  
KDC_NTA.G04 Page 4 of 4  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY