VKA100  
100 Watt Adjustable Output DC/DC Converter  
„
Operation to +100
°
C Baseplate  
„ꢀ  
RoHS Compliant  
Temperature  
TARGETED FOR  
„ꢀ  
33 - 75V Input Range  
„
Primary Remote On/Off, Choice of  
Pos/Neg Logic  
„ꢀ  
High Effiiency: 87% Typical at 5V  
OBSOLESCENCE  
„ꢀ  
100mS Tansient Response 50-  
„
Adjustable Output Voltage  
100% Load Step  
„
ꢀ  
Co
nt
in
uo
ut
S
ho
rt
-
C
ir
cu
it P
rotection  
„ꢀ  
420 kHz Fixed-Frequency  
„ꢀ  
Thermal Shutdown  
Operation  
„ꢀ  
Case Ground Pin  
„ꢀ  
Remote Sense  
The VKA100xSC Series DC/DC con-  
verters present an economical and  
practical solution for distributed power  
system architectures which require  
backup applications common in today’s  
telecommunication and electronic data  
processing applications. The output is  
fully isolated from the input, allowing  
The patented fixed frequency  
architecture combined with surface  
mount technology results in a compact,  
efficient and reliable solution to DC/  
DC conversion requirements. Safety Per  
UL1950, EN 60950 and CSA 22.2 #234  
high power density and efficiency while for a variety of polarity and grounding  
maintaining system modularity and  
upgradeability. With the ability to oper-  
ate over a wide input voltage range  
of 18 to 36 and 33 to 75 volts, these  
modules are ideal for use in battery  
configurations.  
The VKA100xSC’s proprietary con-  
trol circuitry responds to 50-100% load  
steps in 100mSeconds to within 1%  
nominal Vout.  
PRODUCT SELECTION CHART  
MODEL  
INPUT  
VOLTAGE  
VOUT  
(VDC)  
IOUT  
(A)  
EFFICIENCY  
TYP  
MIN  
75  
73  
75  
80  
80  
85  
87  
88  
89  
76  
74  
77  
81  
81  
86  
88  
89  
89  
OBSOLETE  
OBSOLETE  
VKA100LS02C  
VKA100LS02FC  
VKA100LS2V5FC  
VKA100LS03C  
VKA100LS03FC  
VKA100LS05C  
VKA100LS12C  
VKA100LS15C  
VKA100LS24C  
VKA100MS02C  
VKA100MS02FC  
VKA100MS2V5FC  
VKA100MS03C  
VKA100MS03FC  
VKA100MS05C  
VKA100MS12C  
VKA100MS15C  
VKA100MS24C  
2.0V  
2.0V  
2.5V  
3.3V  
3.3V  
5.0V  
12.0V  
15.0V  
24.0V  
2.0V  
2.0V  
2.5V  
3.3V  
3.3V  
5.0V  
12.0V  
15.0V  
24.0V  
20.0  
30.0  
30.0  
20.0  
30.0  
20.0  
8.3  
76  
74  
76  
81  
81  
86  
88  
89  
90  
77  
75  
78  
82  
82  
87  
89  
90  
90  
OBSOLETE  
OBSOLETE  
OBSOLETE  
TARGETED FOR OBSOLESCENCE  
TARGETED FOR OBSOLESCENCE  
TARGETED FOR OBSOLESCENCE  
TARGETED FOR OBSOLESCENCE  
24VDC  
(18-36)  
6.7  
4.2  
OBSOLETE  
OBSOLETE  
OBSOLETE  
OBSOLETE  
20.0  
30.0  
30.0  
20.0  
30.0  
20.0  
8.3  
OBSOLETE  
OBSOLETE  
48VDC  
(33-75)  
TARGETED FOR OBSOLESCENCE  
6.7  
OBSOLETE  
OBSOLETE  
4.2  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com  
email: sales@murata-ps.com  
04 May 2011 VKA100C.BO5 Page 1 of 4  
VKA100  
100 Watt Adjustable Output DC/DC Converter  
Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified.  
SPECIFICATIONS, ALL MODELS  
PARAMETER  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
INPUT  
Voltage Range  
VKA100LS  
VKA100MS  
18  
33  
24  
48  
36  
75  
VDC  
VDC  
Maximum Input Current  
VKA100LS  
V
V
IN = 16VDC  
IN = 27VDC  
7.4  
4.4  
A
A
VKA100MS  
Reflected Ripple Current  
Input Ripple Rejection  
No Load Input Current LS/MS  
Peak - Peak  
DC to 1KHz  
20  
60  
140/80  
mA  
dB  
mA  
50  
No Load  
Power Dissipation LS/MS  
3.4/3.8  
W
W
Standby, Primary On/Off  
Disabled LS/MS  
Inrush Charge  
0.12/0.24  
V
IN = VINmax.  
VKA100LS  
VKA100MS  
0.520  
0.360  
mC  
mC  
Quiescent Operating Current  
Primary On/Off Disabled  
5
12  
mA  
PARAMETER  
Rated Power  
Set point Accuracy  
Line Regulation  
Load Regulation  
CONDITIONS  
MIN  
0
TYP  
MAX  
100  
1
0.05  
0.5  
UNITS  
W
%
%
%
High Line to Low Line  
No Load to Rated Load  
0.02  
0.2  
Output Temperature Drift  
Output Ripple, p-p  
Output Current Limit Inception  
Output Short-Circuit Current (2)  
Output Overvoltage Limit  
Transient Response  
Peak Deviation  
.02  
1%  
130%  
120%  
125%  
%/°C  
DC to 20MHz BW  
test  
V
l
l
OUT, Nom  
OUT, Nom  
OUT, Nom  
V
150%  
150%  
135%  
50 to 100% Load Step  
di/dt = 0.1A/μSec  
2%  
V
OUT, Nom  
Settling Time  
VOUT, 1% of Nominal Output  
100  
μSec  
PARAMETER  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
ISOLATION  
Input to Output  
Peak Test for 2 Seconds  
1500  
1500  
500  
10  
VDC  
VDC  
VDC  
MΩ  
Input to Baseplate  
Output to Baseplate  
Resistance  
Capacitance  
Leakage Current  
GENERAL  
2000  
180  
pF  
μA, rms  
V
ISO = 240VAC, 60Hz  
Efficiency, Line, Load, Temp. (3)  
Switching Frequency  
Remote Sense Compensation  
Output Voltage Adjust Range  
Remote On/Off Control Inputs  
Primary  
400  
420  
440  
0.5  
KHz  
V
VOUT, Nom  
12 V & higher(4)  
-50% / +25%  
Open Collector/Drain  
Sink Current-Logic Low  
Vlow  
1.0  
0.4  
mA  
V
Vhigh0  
Turn-on Time  
Open Collector  
12.5  
Within 1% of Rated Output  
10.0  
mSec  
Weight  
85 (3.0)  
g (oz.)  
TEMPERATURE  
Operation/Specification  
Storage  
Shutdown Temperature  
Thermal Impedance, case-ambient  
Lead Solder Temperature  
Case Temperature  
Case Temperature  
Case Temperature  
-40  
-55  
+100  
+25  
+25  
+100  
+125  
+115  
°C  
°C  
°C  
°C/W  
°C  
7.1  
10 Seconds max  
+300  
NOTES: (1) See Typical Performance Curves, page 3  
(2) Continuous Mode  
(3) See graphs for Efficiency vs. Output Load, VIN, TCASE  
(4) 3.3V Models Limited in Trim Down Range  
(5) Consult Factory for Details  
www.murata-ps.com  
email: sales@murata-ps.com  
04 May 2011 VKA100C.BO5 Page 2 of 4  
VKA100  
100 Watt Adjustable Output DC/DC Converter  
Ambient Air Temperature (°C)  
VKA100 xSzz -  
Device Family  
Indicates 100 Watt Regulated Unit  
Model Number  
Selected from Table of Electrical Characteristics  
Where:  
x = Input Voltage (L = 24VDC; M = 48VDC)  
zz = Output Voltage (03=3.3V, 05=5V, etc.)  
Lead Length  
0.200” - No Number  
0.145” - (6)  
0.110” - (8)  
Remote On-Off Logic:  
Positive - No Number  
Negative - (1)  
www.murata-ps.com  
email: sales@murata-ps.com  
04 May 2011 VKA100C.BO5 Page 3 of 4  
VKA100  
100 Watt Adjustable Output DC/DC Converter  
MECHANICAL  
NOTES:  
All dimensions are in inches (millimeters).  
PIN PLACEMENT TOLERANCE: 0.005”  
MECHANICAL TOLERANCE: 0.015”  
0.530 MAX  
[13.46]  
Marked with: specific modeL ordered, date code, job  
code.  
0.20 [5.1]  
.040 [1.02] DIA.  
7 PLACES  
.081 [2.06] DIA.  
2 PLACES  
MATERIAL: Units are encapsulated in  
a low thermal  
resistancemoldingcompoundwhichhasexcellentchemical  
resistance and electrical properties in high humidity  
environments and over  
a wide operating temperature  
range. The encapsulant and outer shell of the unit have  
UL94V-0 ratings. Lead material is solder plated to allow  
ease of solderability.  
0.20 [5.1]  
0.50 [12.7]  
.400 [10.16]  
0.40 [10.16]  
2.000  
[50.80]  
0.700  
[17.78]  
1.000  
[25.40]  
1.000  
[25.40]  
2.40  
[61.0]  
MAX  
1.400  
1.400  
[35.56]  
[35.56]  
MOUNTING INSERTS M3 X 0.5 THRU, 4 PLACES  
MAX. TORQUE, 8 IN/LBS  
1.900  
0.19 [4.8]  
[48.26]  
OUTPUT ADJUST VOLTAGE  
OVP NOTE  
This feature allows the user to accurately adjust the module’s  
output voltage set point to a specified level. This is achieved  
by connecting a resistor or potentiometer from the TRIM  
terminal to either the +Vout terminal (for increased Vout) or  
the -Vout terminal (for decreased Vout). The formulae below  
describe the trim resistor value to obtain a Vout change of  
Δ%. VO is output voltage prior to adjustment (3.3V, 5V, 12V,  
15V, or 24V).  
Special attention should be given to the peak voltage  
deviation during a dynamic load step when trimming the  
output above the original set point to avoid tripping the  
overvoltage protection circuit. Should an OVP condition  
occur, the converter will go into a latch condition and  
must be externally reset before it will return to normal  
operation.  
Vo(100 + Δ%)  
(100 + 2Δ%)  
_
Radj - up =  
(
)
kΩ  
1.225 %  
%
Δ
Δ
100  
Δ
Radj - down =  
(
- 2  
)
kΩ  
%
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
notice.  
© 2011 Murata Power Solutions, Inc.  
www.murata-ps.com/locations  
email: sales@murata-ps.com  
04 May 2011 VKA100C.BO5 Page 4 of 4  

相关型号:

VKA100LS02

100 WATT SINGLE OUTPUT HALF BRICK DC/DC CONVERTER
CANDD

VKA100LS02-1

Analog IC
ETC

VKA100LS02-6

Analog IC
ETC

VKA100LS02-61

Analog IC
ETC

VKA100LS02-8

Analog IC
ETC

VKA100LS02-81

Analog IC
ETC

VKA100LS02C

100 Watt Adjustable Output DC/DC Converter
MURATA

VKA100LS02F

100 WATT SINGLE OUTPUT HALF BRICK DC/DC CONVERTER
CANDD

VKA100LS02F-1

Analog IC
ETC

VKA100LS02F-6

Analog IC
ETC
ETC

VKA100LS02F-8

Analog IC
ETC