LKS1AF-12V [NAIS]

250 mW Slim Power Relay; 250兆瓦的超薄功率继电器
LKS1AF-12V
型号: LKS1AF-12V
厂家: NAIS(MATSUSHITA ELECTRIC WORKS)    NAIS(MATSUSHITA ELECTRIC WORKS)
描述:

250 mW Slim Power Relay
250兆瓦的超薄功率继电器

继电器 功率继电器
文件: 总3页 (文件大小:48K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VDE  
LK-S  
RELAYS  
250 mW Slim Power Relay  
FEATURES  
11.0  
.433  
24.0  
.945  
1. High sensitivity: 250mW  
The power-saving relay is highly sensitive  
at the nominal operating power of 250  
mW (530 mW power consumption on LK  
relays).  
3. High noise immunity realized by the  
card separation structure between  
contact and coil  
25.0  
.984  
4. Popular terminal pitch in AV equip-  
ment field  
2. High insulation resistance between  
contact and coil  
1) Creepage distance and clearances  
between contact and coil: Min. 6 mm .236  
inch (In compliance with IEC65)  
2) Surge withstand voltage between con-  
tact and coil: 10,000 V or more  
5. Space-saving slim type  
Base area: Width 11 × Length 24 mm  
Width .433 × Length .945 inch  
mm inch  
6. Conforms to the various safety stan-  
dards  
UL/CSA, VDE, TÜV and SEMKO SEV  
approved  
SPECIFICATIONS  
Contact  
Characteristics  
Arrangement  
1 Form A  
Max. operating speed  
20 cpm (at rated load)  
Initial contact resistance, max.  
(By voltage drop 6 V DC 1 A)  
Initial insulation resistance*1  
Min. 1,000 M(at 500 V DC)  
Max. 100 mΩ  
Between open  
contacts  
Initial *2  
breakdown  
voltage  
1,000 Vrms for 1 min.  
Contact material  
Silver alloy  
5 A 277 V AC  
1,385 V A  
277 V AC  
5 A (AC)  
Nominal switching capacity  
Between contact and  
coil  
4,000 Vrms for 1 min.  
Max. switching power  
Max. switching voltage  
Max. switching current  
Mechanical (at 180 cpm)  
Rating  
(resistive load)  
Initial surge voltage between contact  
and coil*3  
Operate time*4 (at nominal voltage)  
Release time (without diode)*4  
(at nominal voltage)  
Min. 10,000 V  
Approx. 7 ms (at 20°C 68°F)  
Approx. 2 ms (at 20°C 68°F)  
106  
Expected life  
(min. operations)  
Electrical (at 20 cpm)  
(at rated load)  
105  
Max. 35°C with nominal coil  
voltage and at 5 A contact  
carrying current  
(resistance method)  
Min. 200 m/s2{approx. 20 G}  
Coil  
Temperature rise (at 70°C)  
Nominal operating power  
250 mW  
Remarks  
Functional*5  
Destructive*6 Min. 1,000 m/s2{approx. 100 G}  
* Specifications will vary with foreign standards certification ratings.  
*1 Measurement at same location as "Initial breakdown voltage" section.  
*2 Detection current: 10mA  
Shock resistance  
10 to 55Hz  
Functional*7  
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981  
*4 Excluding contact bounce time.  
at double amplitude of 1.5mm  
Vibration resistance  
*5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs  
*6 Half-wave pulse of sine wave: 6 ms  
10 to 55Hz  
Destructive  
at double amplitude of 1.5mm  
*7 Detection time: 10 µs  
Ambient  
temp.  
–40°C to +70°C  
–40°F to +158°F  
*8 Refer to 5. Conditions for operation, transport and storage mentioned in  
AMBIENT ENVIRONMENT (Page 24).  
Conditions for operation,  
transport and storage*8  
(Not freezing and con-  
densing at low tempera-  
ture)  
Humidity  
5 to 85% R.H.  
Air  
pressure  
86 to 106 kPa  
Unit weight  
Approx. 12 g .42 oz  
TYPICAL  
ORDERING INFORMATION  
APPLICATIONS  
Ex. LKS 1a  
F
12V  
• Audio visual equipment  
• Office equipment  
• Home appliances  
Contact arrangement  
1a: 1 Form A  
Protective construction  
F: Flux-resistant type  
Coil voltage(DC)  
5, 9, 12, 24V  
UL/CSA, TÜV, SEMKO, TV-5 approved type is standard.  
Notes 1. Standard packing Carton: 100 pcs. Case: 500 pcs.  
2. 6 V, 18 V DC types are also available. Please consult us for details.  
53  
LK-S  
TYPES AND COIL DATA (at 20°C 68°F)  
Pick-up  
voltage,  
Drop-out  
voltage,  
Nominal  
operating  
current,  
Maximum  
allowable  
voltage,  
Nominal  
voltage,  
V DC  
Nominal  
operatingpower,  
mW  
Coil resistance,  
Part No.  
V DC (max.)  
(Initial)  
V DC (min.)  
(Initial)  
(±10%)  
mA (±10%)  
V DC (at 20°C 68°F)  
LKS1aF-5V  
LKS1aF-9V  
LKS1aF-12V  
LKS1aF-24V  
5
9
3.5  
6.3  
0.5  
0.9  
1.2  
2.4  
100  
324  
50  
250  
250  
250  
250  
6.5  
27.8  
20.8  
10.4  
11.7  
15.6  
31.2  
12  
24  
8.4  
576  
16.8  
2,304  
mm inch  
DIMENSIONS  
PC board pattern (Bottom view)  
2-0.9 dia  
2-.035 dia  
2-1.3 dia  
2-.051 dia  
16.5  
.650  
Max. 25.0  
.984  
7.5  
.295  
0.5  
.020  
20.0  
.787  
4
.157  
Tolerance: ±0.1 ±.004  
Schematic (Bottom view)  
0.5 dia.  
.020 dia.  
0.3  
.012  
0.4  
.016  
1.65  
.065  
Max. 24.0  
.945  
Max. 11.0  
.433  
16.5  
.650  
1.0  
.039  
Dimension:  
Max. 1mm .039 inch:  
General tolerance  
±0.1 ±.004  
7.5  
.295  
1 to 3mm .039 to .118 inch: ±0.2 ±.008  
Min. 3mm .118 inch: ±0.3 ±.012  
20.0  
.787  
REFERENCE DATA  
1. Max. switching power (AC resistive load)  
2. Coil temperature rise  
3.Ambient temperature characteristics and coil  
applied voltage  
Contact current: 5 A  
Sample: LKS1aF-12V, 6 pcs.  
Point measured: coil inside  
Contact current: 0 A, 5A  
30  
25  
20  
15  
10  
5
500  
100  
20°C 5A  
20°C 0A  
400  
70°C 5A  
70°C 0A  
Allowable ambient temperatures  
against % coil voltages  
(max. inside the coil tem-  
10  
5
300  
perature set as  
115°C 239°F)  
200  
1
Cold start  
100  
Pick-up voltage  
0
0
0
80  
100  
120  
0
10 20 30 40 50 60 70 80  
0
10  
100  
Contact voltage, V  
Coil applied voltage, %V  
Ambient temperature, °C  
4. Life curve  
Operation frequency: 20 times/min.  
(ON/OFF = 1.5s: 1.5s)  
Ambient temperature: Room temperature  
100  
250V AC resistive load  
10  
1
0
1
2
3
4
5
Contact current, A  
54  
LK-S  
5-(1). Electrical life test  
Change of pick-up and drop-out voltage  
Change of contact resistance  
(5 A 277 V AC, resistive load)  
12  
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
Sample: LKS1aF-12V, 6 pcs.  
Operation frequency: 20 times/min.  
(ON/OFF = 1.5s: 1.5s)  
10  
Pick-up voltage  
Ambient temperature: 20°C 68°F  
Max.  
8
6
x
Circuit:  
Min.  
Max.  
x
Contact  
welding  
detection  
and Mis-  
contacting  
detection  
circuit  
Min.  
4
Drop-out voltage  
277V AC  
12V DC  
Max.  
x
Min.  
2
0
0
0
5
10  
0
5
10  
No. of operations, ×104  
No. of operations, ×104  
5-(2). Electrical life test (UL lamp load test TV-5)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Tested sample: LKS1aF-12V, 6 pcs.  
• Overload test  
Load: 7.5 A 120 V AC (60 Hz),  
Inrush: 111 A  
Operation frequency: 10 times/min  
(ON: OFF = 1 s: 5 s)  
No. of operations: 50 ope.  
• Endurance test  
Load: 5A 120 V AC (60 Hz),  
Inrush: 78 A  
Operation frequency: 10 times/min  
(ON: OFF = 1 s: 5 s)  
12  
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
10  
Pick-up voltage  
8
Max.  
x
Min.  
6
4
Max.  
x
Drop-out voltage  
Max.  
No. of operations: 25,000 ope.  
x
2
0
Min.  
Min.  
2.5  
0
0
0
2.5  
No. of operations, ×104  
No. of operations, ×104  
For Cautions for Use, see Relay Technical Information (Page 11 to 39).  
55  

相关型号:

LKS1AF-18V

Power/Signal Relay, SPST, Momentary, 0.014A (Coil), 18VDC (Coil), 250mW (Coil), DC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC

LKS1AF-24V

250 mW Slim Power Relay
NAIS

LKS1AF-5V

250 mW Slim Power Relay
NAIS

LKS1AF-6V

Power/Signal Relay, SPST, Momentary, 0.042A (Coil), 6VDC (Coil), 250mW (Coil), DC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC

LKS1AF-9V

250 mW Slim Power Relay
NAIS

LKS1E103MESA

ALUMINUM ELECTROLYTIC CAPACITORS
NICHICON

LKS1E103MESB

ALUMINUM ELECTROLYTIC CAPACITORS
NICHICON

LKS1E103MESC

ALUMINUM ELECTROLYTIC CAPACITORS
NICHICON

LKS1E103MESY

ALUMINUM ELECTROLYTIC CAPACITORS
NICHICON

LKS1E103MESZ

ALUMINUM ELECTROLYTIC CAPACITORS
NICHICON

LKS1E123MESA

ALUMINUM ELECTROLYTIC CAPACITORS
NICHICON

LKS1E123MESB

ALUMINUM ELECTROLYTIC CAPACITORS
NICHICON