Features  
Outline Dimension  
Unit (mm)  
• Optical Output Power: CW 70mW (@Tc=25°C)  
• Peak Wavelength: 370~380nm  
Φ
Φ
• Can Type: φ 5.6 Floating Mounted with Photo Diode and Zener Diode  
(90°)  
Absolute Maximum Ratings  
Emitting Point  
(0.4)  
Absolute  
Maximum Ratings  
Item  
Symbol  
Unit  
1.0±0.1  
Po  
Ir (LD)  
Vr (PD)  
Tstg  
85  
mW  
Optical Output Power (Tc=25°C)*  
Allowable Reverse Current  
PD Reverse Voltage  
Z+  
Φ
Φ
4.2±0.2  
85  
5
mA  
V
3.55±0.1  
Emitting Point  
Reference Plane  
Storage Temperature  
-40 ~ 85  
10 ~ 40  
°C  
°C  
Operating Case Temperature  
Tc  
Φ 0.43±0.08  
Initial Electrical/Optical Characteristics  
(Tc=25°C)  
3
Item  
Condition Symbol Min Typ. Max Unit  
X+  
1
2
Optical Output Power*  
CW  
Po  
-
370  
-
-
70  
380  
75  
mW  
nm  
mA  
mA  
W/A  
V
4
Φ
2.0±0.2  
Peak Wavelength  
Threshold Current  
Operating Current  
Slope Efficiency  
Operating Voltage  
Po=70mW  
CW  
-
λp  
Ith  
Iop  
Y+  
50  
110  
1.2  
5.4  
9.0  
( ) are reference figures  
Po=70mW  
CW  
-
140  
-
Pin Connection  
0.9  
-
η
Po=70mW  
Po=70mW  
Vop  
6.0  
11.0  
Parallel  
Beam  
6.0  
°
θ//  
θ⊥  
Divergence**  
Perpendicular Po=70mW  
Parallel Po=70mW  
Perpendicular Po=70mW  
Po=70mW  
19.0 22.5 26.0  
°
-3.0  
-3.0  
0.05  
-
-
3.0  
3.0  
2.0  
°
∆θ//  
∆θ⊥  
Im  
Beam Pointing  
Accuracy  
°
This model has a Zener Diode built in  
as a protection circuit against static  
electricity.  
Monitor Current***  
0.2  
mA  
* Refer graph of Optical Output Power vs. Case Temperature.  
** Full angle at 50% from peak intensity  
*** Monitor Current is short time power reference purpose only.  
Not guaranteed for accuracy.  
Optical Output Power vs. Case Temperature  
100  
85  
70  
60  
50  
All figures in this specification are measured by Nichia's method and may  
contain measurement deviations.  
0
This model is Engineering Sample for evaluation or design purpose only.  
Life time is not guaranteed.  
10 15 20 25 30 35 40 45 50  
Case Temperature [  
]
The above specifications are for reference purpose only and subjected to change without prior notice.  
HEADQUARTERS  
NICHIA CORPORATION  
http://www.nichia.co.jp  
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN  
PHONE: +81-884-22-2311 FAX: +81-884-21-0148  
CONTACT  
TOKYO SALES OFFICE  
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-Ku, TOKYO 108-0014, JAPAN  
PHONE: +81-3-3456-3108  
FAX: +81-3-5440-7330  
-1-  
[
UTZ-SC0320_2  
2012/10/02  
]
Typical Characteristics  
Optical Output Power vs. Forward Current  
Forward Voltage vs. Forward Current  
90  
7
6
5
4
3
2
1
0
80  
Tc = 20ºC  
70  
Tc = 40ºC  
60  
50  
40  
30  
20  
10  
0
Tc = 20ºC  
Tc = 40ºC  
0
20  
40  
60  
80  
100  
120  
0
20  
40  
60  
80  
100  
120  
Forward Current [mA]  
Forward Current [mA]  
Threshold Current vs. Case Temperature  
Peak Wavelength vs. Case Temperature  
70  
65  
60  
55  
50  
45  
40  
35  
30  
381  
380  
379  
378  
377  
376  
375  
10  
20  
30  
40  
10  
20  
30  
40  
Case Temperature [ºC]  
Case Temperature [ºC]  
Far Field Pattern  
Spectrum  
θ//  
θ
377  
377.5  
378  
378.5  
379  
379.5  
380  
-40 -30 -20 -10  
0
10  
20  
30  
40  
Wavelength [nm]  
Angle [°]  
-2-  
[
UTZ-SC0320_2  
2012/10/02  
]
Cautions  
(1) Safety of Laser light  
Laser beam are extremely dangerous to human eyes. Never look at laser  
beam directly and/or through optical lens. When handling the LDs, wear  
appropriate safety glasses to prevent laser light, even any reflections from  
entering to the eye. Focused laser beam through optical instruments will  
increase the chance of eye hazard.  
Nichia LDs are classified in Class 3B of IEC60825-1 and 21 CFR Part  
1040.10 Safety Standards. It is absolutely necessary to take overall safety  
measures against User's modules, equipment and systems into which Nichia  
LDs are incorporated and/or integrated.  
(2) Operating method  
The LD shall change its forward voltage requirement and optical output power according to temperature change. Also,  
the LD will require more operation current to maintain same output power as it degrades.  
Confirm that the optical output power generated by spike current when switching on and off does not exceed the  
maximum absolute rating.  
the Circuit.  
Also, employ appropriate countermeasures to reduce chattering and/or overshooting in  
(3) Static Electricity  
Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist  
strap or anti-electrostatic glove when handling the Product.  
(4) Absolute Maximum Rating  
Active layer of LDs shall have high current density and generate high electric field during its operation. In order to  
prevent excessive damage, the LD must be operated strictly below Absolute Max Rating.  
(5) Others  
Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office  
equipment, communications equipment, measurement instruments and household appliances). Consult Nichia’s sales  
staff in advance for information on the applications in which exceptional quality and reliability are required,  
particularly when the failure or malfunction of the LDs may directly jeopardize life or health (such as for airplanes,  
aerospace, submersible repeaters, nuclear reactor control systems, automobiles, traffic control equipment, life support  
systems and safety devices).  
The Purchaser must acknowledge that any LD can be failed statically and must design its equipments fail safe design.  
Prior to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy  
needs of, and provides the features required by the Circuit and any related modules, equipment and/or systems.  
Due to its short wavelength and high optical output power, optical depositions on optical path may occur depending on  
surrounding conditions. Appropriate design or countermeasures should be used to avoid optical depositions.  
Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or  
design of the LD.  
The appearance and specifications of the product may be modified for improvement without notice. The formal  
specifications must be exchanged and signed by both parties before large volume purchase begins.  
No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted.  
-3-  

相关型号:

NDU4316E

Ultra Violet Laser Diode
NICHIA

NDU502C1R10

Low cost, solid state temperature sensor
AMPHENOL

NDU502C1R3

Low cost, solid state temperature sensor
AMPHENOL

NDU502C1R5

Low cost, solid state temperature sensor
AMPHENOL

NDU502C2AR10

Low cost, solid state temperature sensor
AMPHENOL

NDU502C2AR3

Low cost, solid state temperature sensor
AMPHENOL

NDU502C2AR5

Low cost, solid state temperature sensor
AMPHENOL

NDU502C2R10

Low cost, solid state temperature sensor
AMPHENOL

NDU502C2R3

Low cost, solid state temperature sensor
AMPHENOL

NDU502C2R5

Low cost, solid state temperature sensor
AMPHENOL

NDU502C3R10

Low cost, solid state temperature sensor
AMPHENOL

NDU502C3R3

Low cost, solid state temperature sensor
AMPHENOL