PA-960-104P-G3-2 [NIDEC]
THIN-FILM HIGH PRESSURE TRANSDUCER;型号: | PA-960-104P-G3-2 |
厂家: | NIDEC COMPONENTS |
描述: | THIN-FILM HIGH PRESSURE TRANSDUCER 传感器 换能器 |
文件: | 总4页 (文件大小:193K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
受圧部サージ圧防止構造の油圧用高圧センサ
PA-960/PA-968
THIN-FILM HIGH PRESSURE TRANSDUCER.
INTERNAL STRUCTURE
PA-960/PA-968
1
2
3
4
Part name
Material
SUS 304
―
■
FEATURES
Case
1
2
3
4
ꢀꢁCompact and lightweight
Board
ꢀꢁTo support maximum of 50 MPa(s).
ꢀꢁDigital coverage for a high accuracy
ꢀꢁMounting by connector for an easy wiring
ꢀꢁ High water proof structure comply with IP67(when
mounting connector)
17-4PH
(Correspond to SUS630)
17-4PH
(Correspond to SUS630)
Sensor module
Fitting
ꢀꢁCE Marking available
■
MODEL NUMBER DESIGNATION
PA-960 - 104P - R2 - 1
Series name
Cable
PA-960:
Blank(Nothing)
1(M12 connector cable:Straight 1m)
2(M12 connector cable:Angle 1m)
(Voltage output
)
PA-968:
(Current output
)
Pressure range
503P 5MPa)、104P
354P 35MPa)、504P
(
(
(
(
10MPa)、204P
(20MPa)、
50MPa)
Fitting
R2
G3(
(
G3/8
R1/4
)
)
(G3/8、included P14 O-ring)
※Please refer to the LIST OF MODEL NUMBERS when placing orders.
PA-960/PA-968
PRESSURE TRANSDUCERS WITH AMP.
■
LIST OF MODEL NUMBERS
Pressure range
Series name
Fitting
Cable
(Reference)
0 ~ 5MPa
0 ~ 10MPa
0 ~ 20MPa
0 ~ 35MPa
0 ~ 50MPa
Nothing
Straight
Angle
PA-960-503P-R2 PA-960-104P-R2 PA-960-204P-R2 PA-960-354P-R2 PA-960-504P-R2
PA-960-503P-R2-1 PA-960-104P-R2-1 PA-960-204P-R2-1 PA-960-354P-R2-1 PA-960-504P-R2-1
PA-960-503P-R2-2 PA-960-104P-R2-2 PA-960-204P-R2-2 PA-960-354P-R2-2 PA-960-504P-R2-2
PA-960-503P-G3 PA-960-104P-G3 PA-960-204P-G3 PA-960-354P-G3 PA-960-504P-G3
PA-960-503P-G3-1 PA-960-104P-G3-1 PA-960-204P-G3-1 PA-960-354P-G3-1 PA-960-504P-G3-1
PA-960-503P-G3-2 PA-960-104P-G3-2 PA-960-204P-G3-2 PA-960-354P-G3-2 PA-960-504P-G3-2
PA-968-503P-R2 PA-968-104P-R2 PA-968-204P-R2 PA-968-354P-R2 PA-968-504P-R2
PA-968-503P-R2-1 PA-968-104P-R2-1 PA-968-204P-R2-1 PA-968-354P-R2-1 PA-968-504P-R2-1
PA-968-503P-R2-2 PA-968-104P-R2-2 PA-968-204P-R2-2 PA-968-354P-R2-2 PA-968-504P-R2-2
PA-968-503P-G3 PA-968-104P-G3 PA-968-204P-G3 PA-968-354P-G3 PA-968-504P-G3
PA-968-503P-G3-1 PA-968-104P-G3-1 PA-968-204P-G3-1 PA-968-354P-G3-1 PA-968-504P-G3-1
PA-968-503P-G3-2 PA-968-104P-G3-2 PA-968-204P-G3-2 PA-968-354P-G3-2 PA-968-504P-G3-2
R1/4
PA-960
(Voltage
output)
Nothing
Straight
Angle
G3/8,included
P14 O-ring
Nothing
Straight
Angle
R1/4
PA-968
(Current
output)
Nothing
Straight
Angle
G3/8,included
P14 O-ring
※ Verify the above model numbers when placing orders.
■
STANDARD SPECIFICATIONS
ꢀꢁUnless otherwise specified, the specs are defined at an ambient temperature of 25
±
5 °C and excitation voltage of 12 V DC.
PA-960/968
Model
Item
number
ꢀꢀꢀ503Pꢀꢀꢀꢀꢀꢀꢀ104Pꢀꢀꢀꢀꢀ ꢀ204Pꢀꢀꢀꢀꢀꢀ 354Pꢀꢀꢀꢀꢀ ꢀ504P
Pressure reference
Gauge
Rated pressure range
Maximum pressure
Operating temp. range
Compensated temp. range
Operating humidity
Storage temp.
MPa
MPa
°C
10
20
20
40
50
65
5
35
50
10
PA - 960:- 20 ~ 85ꢀꢀPA - 968:- 20 ~ 70
°C
−20 ~ 70
%RH
°C
35 ~ 85(No condensation)
- 20 ~ 70(At atmospheric pressure, humidity below 65%RH)
Gases/Liquids compatible with 17-4PH
IP67*
Pressure medium
Protection grade
Net weight
g
Applox.60/Applox.130*
Supply voltage
10.8 ~ 30VDC(include ripple)
10mA Max.(No load)/PA-960
Consumption current
*Including the attached cable
PA-960/PA-968
PRESSURE TRANSDUCERS WITH AMP.
STANDARD SPECIFICATIONS
■
ꢀ
Unless otherwise specified, the specs are defined at an ambient temperature of 25 5 °C, excitation voltage of 12 V DC, and Rated pressure of Pin=0 ~ Pr.
PA-960
1 ~ 5V
PA-968
Item
Model number
Output voltage/Current
Zero voltage/ Current
Span voltage/Current
Linearityꢀ
4 ~ 20mA
4±0.2mA
16±0.2mA
1±0.05V
4±0.05V
%F.S.
%F.S.
±0.5
Hysteresisꢀ
±0.1
±0.2
ZERO
± 0.05
± 0.05
%F.S./°C
Thermal Error
(- 20 ~ 70℃)
SPAN
%F.S./°C
Load resistance
Response
10kΩ 以上
500Ω max.(power supply:24V)**
2ms Max.
** Please refer to the following table or expression to choose load resistance.
■
LOAD RESISTANCE
Please refer to the following table or expression to
choose load resistance of current output type (PA-968).
■ Performance mapping
■ Expression of the load resistance
RL(MAX)
750
Vopr-10.8
RL(MAX)
=
0.026
500
Vopr-10.8
250
RL(MIN)
RL(MIN)
=
-507.7
0.026
0
0
10.8
24
30
Power supply Vop[r VDC]
■
ENVIRONMENTAL CHARACTERISTICS
Test conditions
Test item
Permissible change
(Ta=25 5ꢀCꢁPin=0Mpa)
10 ~ 500 Hz, 1.5 mm P-P,
Vibration
3 directions for 2 hours each
490 m/s2
Shock
3 directions for 3 times each
Analog output (Zero voltage/current, Span voltage/
current:): 2 %F.S., maximum each after test
106 cycles
Pressure cycling
Moisture resistance
0 ~ Rated pressure
40 °C, 90 ~ 95 %RH, 240 hrs.
Analog output (Zero voltage/current, Span voltage/
current:): 5 %F.S., maximum each after test
EMI : EN55011: 2007, A2 : 2007 Group 1, class B
EMS : EN61326-1 : 2006/EN61326-2-3 : 2006 Table 2
EMC
PA-960/PA-968
PRESSURE TRANSDUCERS WITH AMP.
■
ꢀꢁPA-960
INTERNAL CIRCUIT
■
OUTLINE DIMENSIONS
ꢀꢁFittingꢀR2(R 1/4)
48.5
±
1
10
Pressure port
With Snubber
15.5
5.7
6.5 min
Marking
1
2
3
Brown:Power(+)
Black :Analog Output
Pressure
Sensor
Main circuit
-
-
-
PA 96 104P R2
Blue :Common
*
Lot.2Y5
4:F.G.
MADE IN JAPAN
Shield
R1/4
Case
(
22)
(17-4PH
)
(SUS304)
ꢀꢁPA-968
ꢀꢁFittingꢀG3(G 3/8)
1
2
Brown:Power(+)
45±1
5.7
10
Pressure port
Pressure
With Snubber
12
6.5 min
Black:Analog Output
Blue :Calibration
Marking
Sensor
Main circuit
3
4:CAL
Shield
-
-
PA 96 104P-G3
*
Lot.2Y5
MADE IN JAPAN
O-Ring
(Fluororubber)
G3/8
(17-4PH)
Case
SUS304
(22)
(
)
■
M12 ASSEMBLED CABLEꢀ
■
WIRING
(Unit:mm)
Please wire according to the following table for M12 connec-
ꢀꢁStraight
tor cable.
1000±100
M12×1
I/O Connector
(
3.5)
(45)
53
±
5
6±2
2
3
1
M12 Connector Cable
4-pin/3-core×AWG22
4
ꢀꢁAngle
1000±100
Connection
Pin
No.
(
31)
53
±
5
6±2
PA-960
PA-968
Power⊕
1
2
3
4
Power⊕
Analog output
Common
F.G.
Analog output
CAL**
M12 Connector Cable
4-pin/3-core×AWG22
CAL**
F.G:Frame ground
※Do not wire the CAL connection.
ꢀIt may cause malfunction when voltage is applied.
**…Calibration