TF037F-2000-F [NIDEC]

BLOWER OUTLUNE;
TF037F-2000-F
型号: TF037F-2000-F
厂家: NIDEC COMPONENTS    NIDEC COMPONENTS
描述:

BLOWER OUTLUNE

文件: 总9页 (文件大小:252K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
NIDEC COPAL ELECTRONICS CORP.  
1
8
/
Model No. TF037F-2000-F  
Specifications  
Issuing Date  
Aug.1, 2017  
1.Scope  
This document applies to Blower TF037F-2000-F (hereinafter referred to as "PRODUCT"), a  
product of NIDEC COPAL ELECTRONICS CORP. (hereinafter referred to as "NCEL").  
Reference driving circuit :NCEL's standard driving circuit  
2.Specification  
(Note1) Unless otherwise specified, the environmental conditions are 23℃±5℃,normal  
humidity, and atmospheric pressure range 90 to 106kPa.  
(Note2) Measuring conditions :  
Driving circuit = NCEL's standard driving circuit,  
Supply voltage = DC24V, measurement equipment = NCEL's standard equipment  
(Note3) The below specifications specify the characteristics of the Blowers at the time of  
shipment.  
(Note4) Please contact us if you'd like to operate the PRODUCT outside of specifications.  
No.  
1
Items  
Specification  
Remarks  
Rated Voltage  
DC 12 〜24 Vꢀ  
Direction of  
Rotation  
Looking down from the air  
inlet.  
2
CCW (Counter-Clockwise)  
Air  
3
Kind of Gas  
Configuration  
Type of Motor  
Noncorrosive gas  
4
Motor with Centrifugal Blade  
DC Brushless Motor  
Without driving circuit  
5
6
Number of Poles 8 Poles (4 pole pairs)  
7
Drive System  
Bearings  
Impeller  
3 Phase, Bipolar  
8
Aero-Dynamic Bearings  
Centrifugal Turbo Blade  
Drawing ︓ 6404-00635-00  
9
Please refer to attached  
drawing.  
10  
Outline  
No vibration, shock, or  
gyration is to be applied  
during operation.  
Mounting  
Direction  
Shaft vertical to ground, air inlet facing  
upwards  
11  
NIDEC COPAL ELECTRONICS CORP.  
Specification  
2
8
/
No.  
12  
Items  
Remarks  
Max. Input Coil  
Current  
3.0 A rms  
0.67 A  
Excluding inrush current.  
max.  
max.  
Rated Power  
Supply Current  
Rated Power  
Consumption  
13  
14  
at 2.0kPa, 100L/min, DC 24V  
at 2.0kPa, 100L/min, DC 24V  
at 2.0kPa  
16.1 W max.  
100 L/min  
15 Rated Air Flow  
16 Minimum Air Flow 10 L/min  
17 Rated Pressure 2.0 kPa  
Maximum  
at 100L/min  
18  
19  
20  
4.5 kPa  
Absolute maximum pressure.  
at 2.0kPa, 100L/min  
Pressure  
Rated Rotation  
Speed  
31,000 r/min  
10,000 r/min  
(reference value)  
Min.Rotation  
Speed  
Pressure-air flow must be  
within the "area of use"  
specified in "5. Operating  
Range" on P.5.  
Max.Rotation  
Speed  
21  
45,000 r/min  
22 Torque Constant 0.0020〜0.0026 N・m/A (reference value)  
at 2.0kPa, 100L/min.  
Measured at 1m from air inlet.  
Include background noise  
15dB(A).  
Acoustic Audible  
23  
65.0 dB(A )max.  
0.36〜0.66  
Noise  
24 Coil Resistance  
(reference value)  
at 20℃ (Between 2 phase)  
ohm  
(reference value)  
at 20℃, 10kHz  
(Between 2 phase)  
25 Coil Inductance 17〜23 μH  
26 Insulation Class Class E  
Insulation  
JIS C 4003  
DC500V,between terminal  
pins and plate  
JIS C 4003  
ohm min.  
27  
1M  
Resistance  
AC600V for 1sec. between  
terminal pins and Plate.  
JIS C 4003  
Dielectric  
Strength  
28  
Leak current to be less than 1mA.  
72 g (reference value)  
29  
30  
Weight  
19 g・cm2  
Rotor Inertia  
(reference value)  
Max. Axial  
Loading  
Maximum axial force applying  
to the intake (upper housing)  
31  
3N  
max.  
NIDEC COPAL ELECTRONICS CORP.  
Specification  
3
8
/
No.  
32  
Items  
Remarks  
Operating  
Temperature  
Range  
0 to 50℃  
Operating  
Humidity Range  
33  
34  
35  
10 to 95%RH  
-20 to 60℃  
No condensation  
Storage  
Temperature  
Range  
Storage  
Humidity Range  
10 to 95%RH  
No condensation  
Non-operating  
The Blower shall satisfy Specification  
No.12 〜 28 after the following test.  
Kind of  
Vibration  
Sweep  
@ amplitude  
10〜22Hz  
Resistance to  
Vibration  
Frequency  
Range  
1mm  
36  
@ acceleration  
19.6m/s2 (2G)  
22〜50Hz  
Sweep  
To-and-fro, approx. 5min.  
X, Y, Z directions, 60min.  
each  
Test Time  
The Blower shall satisfy Specification  
No.12 〜 28 after the following test.  
294m/s2(30G)  
Acceleration  
Resistance to  
Shock  
37  
Pulse Width  
Shock Wave  
6ms  
Non-operating  
Semi-sinusoidal wave  
Number of  
Shock  
X, Y, Z, directions, once  
per each direction  
NIDEC COPAL ELECTRONICS CORP.  
4
8
/
3.Interface  
Pin No.  
1
Symbol  
Signal  
Air Inlet  
Hall Element Power Supply  
(+12V)  
Vcc  
2
3
4
5
6
7
H2-  
H2+  
H3-  
H3+  
H1-  
H1+  
Hall Element 2 Output  
Hall Element 3 Output  
Hall Element 1 Output  
GND  
1
12  
Manufacturer J.S.T. Mfg. Co. Ltd.  
Part No.  
ꢀSM12B-PASS  
8
GND  
TH  
V
Thermistor Output  
Motor Coil (V)  
9
【Mating Connector】  
Manufacturer J.S.T. Mfg. Co., Ltd.  
10  
(insulation displacement  
connector)  
ꢀ12PAF-6S  
Motor Coil (W)  
Motor Coil (U)  
11  
12  
W
U
ꢀ(retainer︓PAFS-12V-S)  
Part No.  
(crimp type)  
ꢀPAP-12V-S  
(Note5) Parts used for thermistor output;  
ꢀ(contact︓SPHD-001T-P0.5)  
Manufacturer  
Part No.  
:
TDK Corp.  
: NTCG164BH103JT  
(Note4) Either IDC or crimp type can be used as a  
mating connector.  
(Note6) Parts used for hall element output;  
Manufacturer  
Part No.  
: Asahi Kasei EMD Corp.  
: HW-105A  
4.Timing Chart  
H
H1+  
L
H
H1-  
L
H
H2+  
L
H
H2-  
L
H
H3+  
L
H
H3-  
L
+
U
-
+
V
-
+
W
-
0
0
60 120 180 240 300 360  
15 30 45 60 75 90  
[deg] Electrical degree  
[deg] Mechanical degree  
NIDEC COPAL ELECTRONICS CORP.  
0
5
8
/
5.Operating Range  
The following graph is provided for reference only. Values are not guaranteed.  
Conditions: Ambient temperature 23±5℃, normal humidity, atmospheric pressure  
(100±2kPa).  
Make sure the thermistor temperature does not exceed 80℃ during blower operation.  
(Thermistor resistance value R(80 deg C)=1.177kΩ)  
Operating Range at DC24V (1atm)  
5.0  
40,000r/min  
4.0  
35,000r/min  
3.0  
Area of use  
30,000r/min  
2.0  
25,000r/min  
1.0  
0.0  
0
20  
40  
60  
80  
100  
120  
140  
160  
Air Flow [L/min]  
Operating Range at DC12V (1atm)  
5.0  
4.0  
35,000r/min  
30,000r/min  
25,000r/min  
3.0  
2.0  
1.0  
0.0  
Area of use  
0
20  
40  
60  
80  
100  
120  
140  
160  
Air Flow [L/min]  
NIDEC COPAL ELECTRONICS CORP.  
6
8
/
6.Manufacturing Code  
Control no.  
alphabet (A-Z)  
Date of manufacture  
Month of manufacture  
Year of manufacture  
refer to Chart 1  
refer to Chart 2  
last digit of the year (A.D.)  
【Chart 1】  
Date  
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9 10 11 12 13 14 15 16 17 18 19 20  
Code  
9
A
B
C
D
E
F
G
H
J
K
L
Date  
Code  
21 22 23 24 25 26 27 28 29 30 31  
M
N
P
Q
R
T
U
V
W
X
Y
【Chart 2】  
Month  
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9 10 11 12  
Code  
1
9
O
N
D
7.Warranty  
ꢀ7-1.Warranty Period  
Warranty period of the PRODUCT is 1 year from delivery.  
ꢀ7-2.Warranty Scope  
(1) In case a defect is found in the PRODUCT during the above warranty period and NCEL is  
responsible for the defect, NCEL will either repair or replace the defected PRODUCT  
free of charge.  
However, in the following cases, the PRODUCT will not be covered by warranty.  
Defects caused by inappropriate conditions, environments, handlings, and use which are  
not specified in this specification.  
Defects caused by your equipments and/or software.  
Defects caused by modifications and/or repairs which were not done by NCEL.  
Defects which could have been avoided if the PRODUCT was used accordingly to this  
specification.  
Defects which were unpredictable with the scientific or technical level of NCEL at the time  
of shipment.  
Defects caused by external factors such as natural hazards (fire, earthquakes, floods) or  
electrical surges.  
NIDEC COPAL ELECTRONICS CORP.  
7
8
/
(2)  
NCEL will be responsible for the PRODUCT only in which the coverage will be limited to  
Clause 7-2. (1). NCEL shall not be liable for customer's equipment damages, opportunity  
losses, or lost earnings caused by defects of the PRODUCTS. The user shall indemnify NCEL  
and hold NCEL harmless from any liability or damage whatsoever arising out of any action  
not in accordance with this specification.  
ꢀ 7-3.Product Application  
The PRODUCT is designed and manufactured for general-purposes. Please do not use in  
applications such as nuclear power, aviations, railroads, or medical equipment where great  
effect to human lives or wealth are expected.  
However,if NCEL agree with the customer the usage of the PRODUCT in such applications,  
NCEL will warrant the PRODUCT in the same scope described in "7. Warranty" in this  
specification.  
8.Notes  
(1) All values are measured with NCEL's standard equipments unless otherwise specified.  
(2) The PRODUCT is compliant with RoHS directives which went into effect July, 2011.  
Designated hazardous substances are lead, mercury, cadmium, hexavalent chrome,  
brominated flame retardants (PBB, PBDE) and its compounds.  
(3)  
The PRODUCT is compliant with Directive 2006/122/EC of the European Parliament  
(Council Directive 76/769/EEC(30th amendment)) which restricts the use of PFOS.  
(4)  
Contents of this document may be changed without notice. The production of the PRODUCT  
may be discontinued without notice. ꢀPlease confirm with your local contact before ordering.  
(5)  
Please check if the PRODUCT operates normally at every start-up and during operation.  
(6) Please provide safety measures to prevent damages in case of product failures.  
(7)  
Performance cannot be guaranteed in case the PRODUCT is used beyond the specification or  
the PRODUCT is modified.  
(8)  
Depending on the conditions or the environment, functions or performances of the PRODUCT  
may not be satisfied when the PRODUCT is used with other equipments.  
(9) Please do not use the PRODUCT in applications to protect the body.  
(10) Please protect the PRODUCT from condensation.  
(11) Please use the correct supply voltage to operate the PRODUCT.  
(12) Do not disassemble or modify the PRODUCT.  
(13) Turn off the power immediately and stop using the PRODUCT in the following cases.  
In case water or foreign substances get into the PRODUCT.  
In case the PRODUCT is dropped or the housing is broken.  
In case unusual odor, abnormal noise, or smoke are generated from the PRODUCT.  
NIDEC COPAL ELECTRONICS CORP.  
8
8
/
(14) Do not use or store in the following conditions;  
Humid, dusty, or poorly-ventilated area.  
Areas where the temperature is expected to rise (direct sunlight, etc.).  
Areas with corrosive gas or flammable gas in the surrounding air.  
Areas where vibration, shock, or rocking motion is applied directly to the PRODUCT.  
Areas where the PRODUCTS may be splashed with water, oil, or chemicals.  
Areas where static electricity can easily be built up.  
(15) Make sure the wiring is done properly.  
(16) Turn off the power of the PRODUCT and any equipment attached to the PRODUCT when  
putting on or taking off the cables.  
(17) Install the PRODUCT using cushioning materials such as vibration dampeners. Please contact  
us if you have any questions regarding installation.  
(18) Do not block the air inlet and outlet (3 places). Please contact us if you have any questions  
regarding the air inlet and outlet.  
(19) Vibration or audible noise level may change over time due to contamination of the blade.  
Please provide dust-proof constructions around the PRODUCT.  
(20)  
(21)  
Please advise us in case the driving circuit will be designed at the customer's side.  
Please connect and don't use air inlet of this product (2 places) in series.  

相关型号:

TF037F-2000-P

BLOWER OUTLINE
NIDEC

TF04010100J0G

Barrier Strip Terminal Block
AMPHENOL

TF04014000J0G

Barrier Strip Terminal Block
AMPHENOL

TF04014100J0G

Barrier Strip Terminal Block
AMPHENOL

TF04014200J0G

Barrier Strip Terminal Block
AMPHENOL

TF04015200J0G

Barrier Strip Terminal Block
AMPHENOL

TF04016000J0G

Barrier Strip Terminal Block
AMPHENOL

TF04016100J0G

Barrier Strip Terminal Block
AMPHENOL

TF04019100J0G

Barrier Strip Terminal Block
AMPHENOL

TF0402B-04P-03

Single Phase EMI Filter
TDK

TF0402B-05P-01

Single Phase EMI Filter
TDK

TF0402B-05P-03

Single Phase EMI Filter
TDK