TF037F-2000-F [NIDEC]
BLOWER OUTLUNE;型号: | TF037F-2000-F |
厂家: | NIDEC COMPONENTS |
描述: | BLOWER OUTLUNE |
文件: | 总9页 (文件大小:252K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
NIDEC COPAL ELECTRONICS CORP.
1
8
/
Model No. TF037F-2000-F
Specifications
Issuing Date
Aug.1, 2017
1.Scope
This document applies to Blower TF037F-2000-F (hereinafter referred to as "PRODUCT"), a
product of NIDEC COPAL ELECTRONICS CORP. (hereinafter referred to as "NCEL").
Reference driving circuit :NCEL's standard driving circuit
2.Specification
(Note1) Unless otherwise specified, the environmental conditions are 23℃±5℃,normal
humidity, and atmospheric pressure range 90 to 106kPa.
(Note2) Measuring conditions :
Driving circuit = NCEL's standard driving circuit,
Supply voltage = DC24V, measurement equipment = NCEL's standard equipment
(Note3) The below specifications specify the characteristics of the Blowers at the time of
shipment.
(Note4) Please contact us if you'd like to operate the PRODUCT outside of specifications.
No.
1
Items
Specification
Remarks
Rated Voltage
DC 12 〜24 Vꢀ
Direction of
Rotation
Looking down from the air
inlet.
2
CCW (Counter-Clockwise)
Air
3
Kind of Gas
Configuration
Type of Motor
Noncorrosive gas
4
Motor with Centrifugal Blade
DC Brushless Motor
Without driving circuit
5
6
Number of Poles 8 Poles (4 pole pairs)
7
Drive System
Bearings
Impeller
3 Phase, Bipolar
8
Aero-Dynamic Bearings
Centrifugal Turbo Blade
Drawing ︓ 6404-00635-00
9
Please refer to attached
drawing.
10
Outline
No vibration, shock, or
gyration is to be applied
during operation.
Mounting
Direction
Shaft vertical to ground, air inlet facing
upwards
11
NIDEC COPAL ELECTRONICS CORP.
Specification
2
8
/
No.
12
Items
Remarks
Max. Input Coil
Current
3.0 A rms
0.67 A
Excluding inrush current.
max.
max.
Rated Power
Supply Current
Rated Power
Consumption
13
14
at 2.0kPa, 100L/min, DC 24V
at 2.0kPa, 100L/min, DC 24V
at 2.0kPa
16.1 W max.
100 L/min
15 Rated Air Flow
16 Minimum Air Flow 10 L/min
17 Rated Pressure 2.0 kPa
Maximum
at 100L/min
18
19
20
4.5 kPa
Absolute maximum pressure.
at 2.0kPa, 100L/min
Pressure
Rated Rotation
Speed
31,000 r/min
10,000 r/min
(reference value)
Min.Rotation
Speed
Pressure-air flow must be
within the "area of use"
specified in "5. Operating
Range" on P.5.
Max.Rotation
Speed
21
45,000 r/min
22 Torque Constant 0.0020〜0.0026 N・m/A (reference value)
at 2.0kPa, 100L/min.
Measured at 1m from air inlet.
Include background noise
15dB(A).
Acoustic Audible
23
65.0 dB(A )max.
0.36〜0.66
Noise
24 Coil Resistance
(reference value)
at 20℃ (Between 2 phase)
ohm
(reference value)
at 20℃, 10kHz
(Between 2 phase)
25 Coil Inductance 17〜23 μH
26 Insulation Class Class E
Insulation
JIS C 4003
DC500V,between terminal
pins and plate
JIS C 4003
ohm min.
27
1M
Resistance
AC600V for 1sec. between
terminal pins and Plate.
JIS C 4003
Dielectric
Strength
28
Leak current to be less than 1mA.
72 g (reference value)
29
30
Weight
19 g・cm2
Rotor Inertia
(reference value)
Max. Axial
Loading
Maximum axial force applying
to the intake (upper housing)
31
3N
max.
NIDEC COPAL ELECTRONICS CORP.
Specification
3
8
/
No.
32
Items
Remarks
Operating
Temperature
Range
0 to 50℃
Operating
Humidity Range
33
34
35
10 to 95%RH
-20 to 60℃
No condensation
Storage
Temperature
Range
Storage
Humidity Range
10 to 95%RH
No condensation
Non-operating
The Blower shall satisfy Specification
No.12 〜 28 after the following test.
Kind of
Vibration
Sweep
@ amplitude
10〜22Hz
Resistance to
Vibration
Frequency
Range
1mm
36
@ acceleration
19.6m/s2 (2G)
22〜50Hz
Sweep
To-and-fro, approx. 5min.
X, Y, Z directions, 60min.
each
Test Time
The Blower shall satisfy Specification
No.12 〜 28 after the following test.
294m/s2(30G)
Acceleration
Resistance to
Shock
37
Pulse Width
Shock Wave
6ms
Non-operating
Semi-sinusoidal wave
Number of
Shock
X, Y, Z, directions, once
per each direction
NIDEC COPAL ELECTRONICS CORP.
4
8
/
3.Interface
Pin No.
1
Symbol
Signal
Air Inlet
Hall Element Power Supply
(+12V)
Vcc
2
3
4
5
6
7
H2-
H2+
H3-
H3+
H1-
H1+
Hall Element 2 Output
Hall Element 3 Output
Hall Element 1 Output
GND
1
12
Manufacturer J.S.T. Mfg. Co. Ltd.
Part No.
ꢀSM12B-PASS
8
GND
TH
V
Thermistor Output
Motor Coil (V)
9
【Mating Connector】
Manufacturer J.S.T. Mfg. Co., Ltd.
10
(insulation displacement
connector)
ꢀ12PAF-6S
Motor Coil (W)
Motor Coil (U)
11
12
W
U
ꢀ(retainer︓PAFS-12V-S)
Part No.
(crimp type)
ꢀPAP-12V-S
(Note5) Parts used for thermistor output;
ꢀ(contact︓SPHD-001T-P0.5)
Manufacturer
Part No.
:
TDK Corp.
: NTCG164BH103JT
(Note4) Either IDC or crimp type can be used as a
mating connector.
(Note6) Parts used for hall element output;
Manufacturer
Part No.
: Asahi Kasei EMD Corp.
: HW-105A
4.Timing Chart
H
H1+
L
H
H1-
L
H
H2+
L
H
H2-
L
H
H3+
L
H
H3-
L
+
U
-
+
V
-
+
W
-
0
0
60 120 180 240 300 360
15 30 45 60 75 90
[deg] Electrical degree
[deg] Mechanical degree
NIDEC COPAL ELECTRONICS CORP.
0
5
8
/
5.Operating Range
The following graph is provided for reference only. Values are not guaranteed.
Conditions: Ambient temperature 23±5℃, normal humidity, atmospheric pressure
(100±2kPa).
Make sure the thermistor temperature does not exceed 80℃ during blower operation.
(Thermistor resistance value R(80 deg C)=1.177kΩ)
Operating Range at DC24V (1atm)
5.0
40,000r/min
4.0
35,000r/min
3.0
Area of use
30,000r/min
2.0
25,000r/min
1.0
0.0
0
20
40
60
80
100
120
140
160
Air Flow [L/min]
Operating Range at DC12V (1atm)
5.0
4.0
35,000r/min
30,000r/min
25,000r/min
3.0
2.0
1.0
0.0
Area of use
0
20
40
60
80
100
120
140
160
Air Flow [L/min]
NIDEC COPAL ELECTRONICS CORP.
6
8
/
6.Manufacturing Code
Control no.
︓
︓
︓
︓
alphabet (A-Z)
Date of manufacture
Month of manufacture
Year of manufacture
refer to Chart 1
refer to Chart 2
last digit of the year (A.D.)
【Chart 1】
Date
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9 10 11 12 13 14 15 16 17 18 19 20
Code
9
A
B
C
D
E
F
G
H
J
K
L
Date
Code
21 22 23 24 25 26 27 28 29 30 31
M
N
P
Q
R
T
U
V
W
X
Y
【Chart 2】
Month
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9 10 11 12
Code
1
9
O
N
D
7.Warranty
ꢀ7-1.Warranty Period
Warranty period of the PRODUCT is 1 year from delivery.
ꢀ7-2.Warranty Scope
(1) In case a defect is found in the PRODUCT during the above warranty period and NCEL is
responsible for the defect, NCEL will either repair or replace the defected PRODUCT
free of charge.
However, in the following cases, the PRODUCT will not be covered by warranty.
Defects caused by inappropriate conditions, environments, handlings, and use which are
not specified in this specification.
●
Defects caused by your equipments and/or software.
●
●
●
Defects caused by modifications and/or repairs which were not done by NCEL.
Defects which could have been avoided if the PRODUCT was used accordingly to this
specification.
Defects which were unpredictable with the scientific or technical level of NCEL at the time
of shipment.
●
●
Defects caused by external factors such as natural hazards (fire, earthquakes, floods) or
electrical surges.
NIDEC COPAL ELECTRONICS CORP.
7
8
/
(2)
NCEL will be responsible for the PRODUCT only in which the coverage will be limited to
Clause 7-2. (1). NCEL shall not be liable for customer's equipment damages, opportunity
losses, or lost earnings caused by defects of the PRODUCTS. The user shall indemnify NCEL
and hold NCEL harmless from any liability or damage whatsoever arising out of any action
not in accordance with this specification.
ꢀ 7-3.Product Application
The PRODUCT is designed and manufactured for general-purposes. Please do not use in
applications such as nuclear power, aviations, railroads, or medical equipment where great
effect to human lives or wealth are expected.
However,if NCEL agree with the customer the usage of the PRODUCT in such applications,
NCEL will warrant the PRODUCT in the same scope described in "7. Warranty" in this
specification.
8.Notes
(1) All values are measured with NCEL's standard equipments unless otherwise specified.
(2) The PRODUCT is compliant with RoHS directives which went into effect July, 2011.
Designated hazardous substances are lead, mercury, cadmium, hexavalent chrome,
brominated flame retardants (PBB, PBDE) and its compounds.
(3)
The PRODUCT is compliant with Directive 2006/122/EC of the European Parliament
(Council Directive 76/769/EEC(30th amendment)) which restricts the use of PFOS.
(4)
Contents of this document may be changed without notice. The production of the PRODUCT
may be discontinued without notice. ꢀPlease confirm with your local contact before ordering.
(5)
Please check if the PRODUCT operates normally at every start-up and during operation.
(6) Please provide safety measures to prevent damages in case of product failures.
(7)
Performance cannot be guaranteed in case the PRODUCT is used beyond the specification or
the PRODUCT is modified.
(8)
Depending on the conditions or the environment, functions or performances of the PRODUCT
may not be satisfied when the PRODUCT is used with other equipments.
(9) Please do not use the PRODUCT in applications to protect the body.
(10) Please protect the PRODUCT from condensation.
(11) Please use the correct supply voltage to operate the PRODUCT.
(12) Do not disassemble or modify the PRODUCT.
(13) Turn off the power immediately and stop using the PRODUCT in the following cases.
●In case water or foreign substances get into the PRODUCT.
●In case the PRODUCT is dropped or the housing is broken.
●In case unusual odor, abnormal noise, or smoke are generated from the PRODUCT.
NIDEC COPAL ELECTRONICS CORP.
8
8
/
(14) Do not use or store in the following conditions;
●Humid, dusty, or poorly-ventilated area.
●Areas where the temperature is expected to rise (direct sunlight, etc.).
●Areas with corrosive gas or flammable gas in the surrounding air.
●Areas where vibration, shock, or rocking motion is applied directly to the PRODUCT.
●Areas where the PRODUCTS may be splashed with water, oil, or chemicals.
●Areas where static electricity can easily be built up.
(15) Make sure the wiring is done properly.
(16) Turn off the power of the PRODUCT and any equipment attached to the PRODUCT when
putting on or taking off the cables.
(17) Install the PRODUCT using cushioning materials such as vibration dampeners. Please contact
us if you have any questions regarding installation.
(18) Do not block the air inlet and outlet (3 places). Please contact us if you have any questions
regarding the air inlet and outlet.
(19) Vibration or audible noise level may change over time due to contamination of the blade.
Please provide dust-proof constructions around the PRODUCT.
(20)
(21)
Please advise us in case the driving circuit will be designed at the customer's side.
Please connect and don't use air inlet of this product (2 places) in series.
相关型号: