NIPXI-PCI8336 [NI]
Multichassis configurations for PXI and CompactPCI; 对于PXI和CompactPCI的多机箱配置型号: | NIPXI-PCI8336 |
厂家: | National Instruments |
描述: | Multichassis configurations for PXI and CompactPCI |
文件: | 总3页 (文件大小:580K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PC Control of PXI (MXI-4)
NEW
NI PXI-PCI8331, NI PCI-8331, NI PXI-8331
NI PXI-PCI8336, NI PCI-8336, NI PXI-8336
• Multichassis configurations for PXI and CompactPCI
• MXI-4 link performance
• 132 Mbytes/s peak
• 78 Mbytes/s sustained
• Fiber-optic or copper cabling
• Low cost with copper
• Electrical isolation and long-range with fiber-optic
• Rugged connectivity
• Error checking and retransmission
• Support for 5 V and 3.3 V PCI
Overview
Multichassis PXI Systems
The National Instruments PXI-PCI833x interface kits give PCs MXI-4 can be used to connect multiple PXI chassis in a star or
direct control of PXI systems using MXI-4 technology. You can daisy-chain configuration within a single system. To connect two
also use NI PXI-8331 and NI PXI-8336 modules for linking PXI chassis together with MXI-4, install a PXI-8331 (copper) or
multiple PXI chassis. MXI-4 is a high-bandwidth link that is PXI-8336 (fiber-optic) module into any peripheral slot of the
transparent to software applications and drivers, therefore master chassis. Connect with the appropriate cable to a second
providing the ability to use high performance desktop computers PXI-8331 or PXI-8336 in slot 1 of the slave chassis. For more
or servers to control PXI systems.
information on the possible star and daisy-chain topologies, please
see the MXI-4 User Manual.
Hardware
PC Control of PXI
MXI-4 Technology
With a MXI-4 link, you can transparently control a PXI system MXI-4 operates as a PCI-to-PCI bridge that achieves software and
from any PCI slot, so high-performance desktop computers or hardware transparency and high performance. MXI-4 builds on
servers can control PXI systems. Because PXI is based on the the standard PCI-to-PCI bridge architecture by splitting the bridge
industry-standard PCI bus, MXI-4 provides a transparent link into two halves connected by a 1.5 Gb/s serial link. Additionally,
where all PXI modules appear to the user as if they were PCI you can create multiple-chassis PXI systems using multiple MXI-4
boards within the computer itself. However, you benefit from the links. The PCI specification allows up to 255 buses to be connected
increased number of slots, power and cooling per slot, module in a system via PCI-PCI bridges such as MXI-4.
selection, and synchronization features provided by PXI.
MXI-4 is an evolution of MXI-3. MXI-4 improves on MXI-3 by
Additionally, with fiber-optic MXI-4 you can electrically isolate supporting both 3.3 V and 5 V PCI signaling environments, error
your PXI measurement hardware from the PC with extended checking and retransmission on the serial link for greater
length cabling up to 200 m.
reliability in electrically noisy or harsh environments, and
The MXI-4 link consists of a PCI-8331 (copper) or PCI-8336 industrially rugged connectors.
(fiber-optic) board in the PC, connected via the appropriate cable
to a PXI-8331 (copper) or PXI-8336 (fiber-optic) module in slot 1
of a PXI chassis. For convenience, you can purchase either a
complete MXI-4 kit with all necessary components, or purchase
the PCI board, PXI module, and cable separately.
PC Control of PXI (MXI-4)
Specifications
Power Requirements
Ordering Information
Current (ADC)
Maximum Typical
PCI-8331, PXI-8331 PCI-8331, PXI-8331 PCI-8336, PXI-8336 PCI-8336, PXI-8336
For online configuration of a complete PXI system, including
chassis, modules, and all accessories, visit ni.com/pxiadvisor.
Volts
Typical
Maximum
+3.3
+5
0.25
1.5
0.30
1.7
0.35
1.5
0.4
1.7
MXI-4 Kits for PXI/CompactPCI
NI PXI-PCI8331 with 3 m copper cable..........................778640-03
NI PXI-PCI8336 with 10 m fiber-optic cable
(isolated)..............................................................................778641-10
(Kit includes one PCI MXI-4 board (PCI-833x), one PXI MXI-4 module (PXI-833x)
module, and one cable).
Physical
Dimensions
PCI-8331/6 ...................................... 10.7 by 17.5 cm (4.2 by 6.9 in.)
PXI-8331/6 ...................................... 3U-size module, 10.0 by 16.0 cm (3.9 by 6.3 in.)
Slot requirements .................................. One 3U PXI system controller slot or peripheral slot
Maximum cable lengths
8331 (copper) .................................. 10 m
8336 (fiber) ...................................... 200 m
PXI MXI-4 Interface Modules
NI PXI-8331 (copper)........................................................778955-01
NI PXI-8336 (fiber-optic)..................................................778957-01
Compatibility .......................................... Fully compatible with PXI Hardware
.................................................... Specification 2.1, and the PCI
.................................................... Specification 2.2
PCI MXI-4 Interface Boards
NI PCI-8331 (copper)........................................................778956-01
NI PCI-8336 (fiber-optic)..................................................778958-01
Operating Environment
Temperature .............................................. 0 to 55 °C (tested in accordance with IEC-60068-2-1
MXI-4 Cables
Copper
and IEC-60068-2-2.)
3 m ..................................................................................190957-03
5 m ..................................................................................190957-05
10 m ................................................................................190957-10
Fiber-optic
Relative humidity .................................... 10 to 90% (tested in accordance with IEC-60068-2-56.)
Storage Environment
Temperature ................................................ –20 to 70 °C (tested in accordance with IEC-60068-2-1
and IEC-60068-2-2.)
10 m ................................................................................778959-10
30 m ................................................................................778959-30
200 m ............................................................................778959-200
Relative humidity .................................... 5 to 95% noncondensing (tested in accordance
with IEC-60068-2-56.)
Shock and Vibration
Operational Shock 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27.
Test profile developed in accordance with MIL-PRF-28800F.)
BUY ONLINE!
Visit ni.com/info and enter pxi-pci833x.
Random Vibration
Operating .............................................. 5 to 500 Hz, 0.3 grms
Nonoperating ........................................ 5 to 500 Hz, 2.4 grms
(Tested in accordance with IEC-60068-2-64. Nonoperating profile exceeds the requirements of
MIL-PRF-28800F, Class 3.)
*Specifications subject to change without notice
Note: For full EMC compliance, you must operate this device with shielded cabling. In addition, all
covers and filler panels must be installed. Refer to the Declaration of Conformity (DoC) for this
product for any additional regulatory compliance information. To obtain the DoC for this product,
click Declaration of Conformity at ni.com/hardref.nsf/. This Web site lists the DoCs by product
family. Select the appropriate product family, followed by your product, and a link to the DoC appears
in Adobe Acrobat format. Click the Acrobat icon to download or read the DoC.
2
National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com
NI Services and Support
NI has the services and support to
meet your needs around the globe
and through the application
lifecycle – from planning and
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you
access to engineers who speak your language. NI delivers industry-
leading technical support through online knowledge bases, our
applications engineers, and access to 14,000 measurement and
automation professionals within NI Developer Exchange forums.
Find immediate answers to your questions at ni.com/support.
We offer service programs which provide automatic upgrades to
your application development environment and higher levels for
technical support. Visit ni.com/ssp
CUSTOMER
NEEDS
development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and Certification
Hardware Services
NI training is the fastest, most certain route to productivity with our NI Factory Installation Services (FIS)
tools. NI training can shorten your learning curve, save NI Factory Installation Services (FIS) is the fastest and easiest way
development time, and reduce maintenance costs over the to use your PXI or PXI/SCXI™ combination systems right out of
application lifecycle. We schedule instructor-led courses in cities the box. Trained NI technicians install the software and hardware
worldwide, or can hold a course at your facility. We also offer a and configure the system to your specifications. NI extends the
professional certification program which identifies individuals who standard warranty by one additional year on hardware components
have a high level of skill and knowledge about using NI products. (controllers, chassis, modules) purchased with FIS. To use FIS,
Visit ni.com/training.
simply configure your system online with ni.com/pxiadvisor.
Professional Services
Calibration Services
Our Professional Services Team is comprised of NI applications NI recognizes the need to maintain properly calibrated devices for
engineers, NI Consulting Services, and a worldwide NI Alliance high-accuracy measurements. We provide manual calibration
Partner Program of more
than more than 600
independent consultants
and integrators. Services
procedures, services to recalibrate your products, and automated,
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
range from start-up assistance to turnkey system integration. Repair and Extended Warranty
Visit ni.com/alliance.
NI provides complete repair services for our products. Express
repair and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle
OEM Support
We offer design-in consulting and product integration assistance if requirements. Visit ni.com/services.
you want to use our products in OEM applications. Visit ni.com/oem.
ni.com • (800) 433-3488
National Instruments • Tel: (512) 683-0100 • Fax: (512) 683-9300 • info@ni.com
© 2004 National Instruments Corporation. All rights reserved. Product and company names listed are trademarks or trade names of their respective companies.
相关型号:
©2020 ICPDF网 联系我们和版权申明